Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA ELECTRODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Operation and upgrade of diagnostic neutral beam injector RUDI at TEXTOR tokamak

The status and the executing modernization of RUssian Diagnostic Injector (RUDI) are described. The ion source consists of arc plasma emitter and multiaperture four-electrode ion optical system. The present ion optical system with round beamlets is to be replaced by new slit apertures system for the reducing beam angular divergence in one direction. Due to enlarged dimensions and transparency of new ion optical system the extracted ion beam current will be by 50% increased. For the extension of beam pulse duration from 4 s to 8-10 s an optimized metal-ceramic arc-discharge channel is introduced. In the paper, the optical measurements results of beam parameters, including the profile of species distribution, scanned by custom-built multichannel spectroscope, are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equilibrium and Stability of Partial Toroidal Plasma Discharges

The equilibrium and stability of partial toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous loop structures on the solar surface. The flux ropes studied here are magnetized arc discharges formed in the Magnetic Reconnection Experiment (MRX). It is found that these loops robustly maintain their equilibrium on time scales much longer than the Alfven time over a wide range of plasma current, guide eld strength, and angle between electrodes, even in the absence of a strapping fi eld. Additionally, the external kink stability of these flux ropes is found to be governed by the Kruskal-Shafranov limit for a flux rope with line-tied boundary conditions at both ends (q > 1).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the gas-flow Reynolds number on a plasma column in a glass tube

Atmospheric-plasma generation inside a glass tube is influenced by gas stream behavior as described by the Reynolds number (Rn). In experiments with He, Ne, and Ar, the plasma column length increases with an increase in the gas flow rate under laminar flow characterized by Rn < 2000. The length of the plasma column decreases as the flow rate increases in the transition region of 2000 < Rn < 4000. For a turbulent flow beyond Rn > 4000, the length of the plasma column is short in front of the electrode, eventually leading to a shutdown.

42 ENGINEERING↗

Influence of inhomogeneous magnetic field on the characteristics of very high frequency capacitively coupled plasmas

The effect of inhomogeneous magnetic field on the spatial structure of very high frequency (VHF) plasmas is investigated for different coil configurations, gas pressures, high frequency bias powers, and degrees of electronegativity. The simulation results show that the electron density peaks in the center of the chamber for VHF plasmas due to the standing electromagnetic wave effect. On application of a magnetic field, the density increases near the wafer edge and decreases at the chamber center. The radial magnetic field component is found to limit electron loss to the electrodes and locally enhance the electron density. The axial magnetic field component limits plasma diffusion in the radial direction helping preserve the effect of improved electron confinement by the radial magnetic field. The peak electron density decreases with increasing magnetic field as the plasma moves toward the electrode edge occupying a larger volume. The effect of magnetic field becomes weaker at higher pressure due to the increased electron-neutral collisions which reduce the effectiveness of electron confinement around the magnetic field lines. The impact of magnetic field on plasma profile is somewhat weaker in an electronegative Ar/CF{sub 4} plasma because of the presence of less mobile and unmagnetized negative ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a dielectric barrier discharge enhanced plasma jet in atmospheric pressure air

A plasma jet equipped with dielectric barrier discharge (DBD) is developed to generate diffuse air plasma with fairly large gap and cross sectional area. The diffuse air plasma has two discharge modes under different gap widths from the nozzle to the ground plate electrode. For large gap width, a diffuse plume fills the whole space between the nozzle and the plate electrode after coaxial DBD is ignited when the applied voltage reaches a certain value. Rather than diffuse plasma plume, a bright plasma column bridges the nozzle and the plate electrode with further increasing the applied voltage under small gap width. By optical and electrical measurement, results show that the macroscopically diffuse discharge in air is obtained by the superimposition of radially distributed streamers that appear at different cycles of the applied voltage, and the bright plasma column belongs to atmospheric pressure glow discharge. The molecular vibrational temperature and the gas temperature are given as functions of the peak value of the applied voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dense plasma ultraviolet source

The intense ultraviolet emission from the NASA Hypocycloidal-Pinch (HCP) plasma is investigated. The HCP consists of three disk electrodes whose cross section has a configuration similar to the cross section of a Mather-type plasma focus. Plasma foci were produced in deuterium, helium, xenon, and krypton gases in order to compare their emission characteristics. Time-integrated spectra in the wavelength range from 200 nm to 350 nm and temporal variations of the uv emission were obtained with a uv spectrometer and a photomultiplier system. Modifications to enhance uv emission in the iodine-laser pump band (250 to 290 nm) and preliminary results produced by these modifications are presented. Finally, the advantages of the HCP as a uv over use of conventional xenon lamps with respect to power output limit, spectral range, and lifetime are discussed.

Lee, J. H.↗

Mitigation of breathing oscillations and focusing of the plume in a segmented electrode wall-less Hall thruster

We report in the absence of the channel walls bounding the plasma, a wall-less Hall thruster is a promising configuration with a potentially longer lifetime and easier scalability than conventional Hall thrusters. Because the ion acceleration takes place in the fringing magnetic field with a strong axial component, the operation of a typical wall-less thruster is characterized by a large beam divergence of the plasma flow, which reduces the thrust. In this work, the addition of a biased segmented electrode to the wall-less thruster is shown to significantly narrow the plasma plume and suppress large amplitude breathing oscillations of the discharge current commonly associated with ionization instability. Both effects result in improvements to the thruster performance. Physical mechanisms responsible for these effects are unclear, but they are apparently associated with the reduction of the electron cross field transport to the anode and a transition in the breathing mode frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thrust Stand Measurements Using Alternative Propellants in the Microwave Assisted Discharge Inductive Plasma Accelerator

Storable propellants (for example water, ammonia, and hydrazine) are attractive for deep space propulsion due to their naturally high density at ambient interplanetary conditions, which obviates the need for a cryogenic/venting system. Water in particular is attractive due to its ease of handling and availability both terrestrially and extra-terrestrially. While many storable propellants are reactive and corrosive, a propulsion scheme where the propellant is insulated from vulnerable (e.g. metallic) sections of the assembly would be well-suited to process these otherwise incompatible propellants. Pulsed inductive plasma thrusters meet this criterion because they can be operated without direct propellant-electrode interaction. During operation of these devices, electrical energy is capacitively stored and then discharged through an inductive coil creating a time-varying current in the coil that interacts with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, many pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Discharge Inductive Plasma Accelerator (MAD-IPA) is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil before the main current pulse via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and a static magnetic field from a set of permanent magnets arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the theta-pinch coil is high. The use of a conical theta-pinch coil also serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT). In this paper, we describe thrust stand measurements performed to evaluate the specific impulse and thrust efficiency of the MAD-IPA for a variety of propellants. Propellants tested include both widely-used, non-reactive noble gases like argon, and rarely-used propellants such as water, hydrazine and ammonia. Dependencies of impulse data on propellant species are discussed in the context of the current sheet formation and electromagnetic plasma acceleration processes.

Hallock, Ashley K.↗

X-ray and EUV Emission Studies of Copper Vacuum Spark Plasma

A vacuum spark system with a copper anode and electrode of gap 1.5 mm is investigated for the purpose of developing it as a possible radiation source for Next Generation Lithography (NGL). At discharge voltage in the range of 10 to 15 kV and an ambient pressure of about 10{sup -3} mbar, both X-ray (measured by PIN diode) and extreme ultraviolet, EUV (measured by SXUV5A with integrated filter) can be measured simultaneously when good pinching discharge as indicated by sharp dip in the waveform of the rate of current is achieved. For discharge with mild pinching, only EUV emission is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of oxidant gas for atomic layer deposition on crystal structure and fatigue of ferroelectric Hf x Zr 1-x O 2 thin films

TiN/Hf x Zr 1-x O 2 (HZO)/TiN capacitors were prepared using two types of HZO films fabricated by atomic layer deposition using H 2 O or O 2 plasma as an oxidant gas, and post-deposition annealing at 400 °C was performed before the TiN top-electrode fabrication. The ferroelectric orthorhombic phase was dominantly formed for the O 2 plasma-based capacitor due to the strongly oxidizing source of O 2 plasma, resulted in higher remanent polarization (2P r = 20 µC/cm 2 ) than that (13 µC/cm 2 ) of the H 2 O-based capacitor. The fatigue properties for the O 2 plasma-based capacitor were improved by 14 % after 106 cycles compared to the H 2 O-based capacitor. This could be attributed to an oxygen-rich interface reaction layer (IRL) including TiO x between the HZO film and TiN bottom-electrode for the O 2 plasma-based capacitor. In conclusion, based on these results, superior 2P r and fatigue properties can be obtained using O 2 plasma-based HZO films.

36 MATERIALS SCIENCE↗

Multi-scale dynamics of atmospheric-pressure discharges ignited over liquid electrodes

A multiphase computational model of atmospheric-pressure gas discharges ignited over liquid electrodes is developed. The model takes into account both the liquid electrode motion under applied electric fields and plasma generation in the gas phase. The influence of the applied voltage and liquid properties (density, viscosity, and surface tension) on the liquid surface deformation is analyzed. It is shown that the shape of dynamic cones formed on the liquid surface differs from the static Taylor's cones. The influence of the liquid surface protrusions on gas breakdown dynamics is demonstrated. It is shown that the breakdown develops in two stages: first, a fast ionization wave propagates from the cathode to the anode, and then the cathode sheath collapses due to secondary electron emission from the liquid surface. It is shown that dynamics of the multiphase system containing gas, plasma, and liquid states is characterized by three disparate time scales: the fast electron time scale, the intermediate ion time scale, and the slow liquid dynamics time scale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Means to remove electrode contamination effect of Langmuir probe measurement in space

Precaution to remove the serious effect of electrode contamination in Langmuir probe experiments has not been taken in many space measurements because the effect is either not understood or ignored. We stress here that one should pay extra attention to the electrode contamination effect to get accurate and reliable plasma measurements so that the long time effort for sounding rocket/satellite missions does not end in vain or becomes less fruitful. In this paper, we describe two main features of voltage-current characteristic curves associated with the contaminated Langmuir probe, which are predicted from the equivalent circuit model, which we proposed in 1970's. We then show that fast sweeping dc Langmuir probes can give reliable results in the steady state regime. The fast sweeping probe can also give reliable results in transient situations such as satellite moves through plasma bubble in the ionosphere where the electron density drastically changes. This fact was first confirmed in our laboratory experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of resonance in external radio-frequency circuit on very high frequency plasma discharge

A fully electromagnetic plasma model for an asymmetric capacitively coupled plasma discharge is used to understand the interaction between the external radio-frequency (rf) distributed circuit and the plasma. The plasma is excited using a 150 MHz rf source connected to the top electrode, the bottom electrode is connected to a shorted transmission line, and the electrodes are separated from the chamber walls through dielectric rings. Under typical conditions, the electron density peaks in the center of the plasma chamber due to the standing electromagnetic wave and the rf current from the top electrode primarily returns through the bottom electrode. When the electrical length of the bottom transmission line is adjusted such that it presents a large (open-circuit) impedance at the plasma chamber interface, the rf return current shifts from the bottom electrode to the chamber wall. As a consequence, the peak in electron density also moves from the center of the chamber toward its outer periphery.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Area influences and floating potentials in Langmuir probe measurements.

Analysis of the influence of a relatively small reference electrode on a Langmuir probe measurement of plasma density and temperature. The analysis employs the collisionless theory of Laframboise for spherical and cylindrical probes and in a completely general way includes a broad range of electron densities and temperatures, as well as all possible values of ion mass and multiplicity of ionization. It is shown that a ratio alpha of reference-electrode area to probe area of 10,000 will guarantee no distortion of the measurement as a result of a shifting reference-electrode potential. It is further shown that the constraint on alpha can be relaxed by approximately two orders of magnitude when the charge-normalized ion mass is decreased from 200 to 1 amu and the ratio of reference-electrode radius to Debye length is decreased from 100 to 0. An additional result of the analysis is the dependence of a probe's floating potential on its geometry and radius, as well as on the properties of the plasma. A discussion of the latter result reveals in a striking manner the significant differences between the ion-current responses of spherical and cylindrical probes.

Szuszczewicz, E. P.↗

Active electrochemical interfaces stabilized through self-organized potential oscillations

Some electrochemical systems are known to have higher average efficiency when operated under an oscillatory regime. Given the compromise between activity and stability, the stability of electrochemical interfaces in a self-organized, oscillatory state must be taken into account. Here we evaluate the electro-oxidation of methanol and formic acid on platinum under regular and oscillatory conditions, and study the stability by following the Pt dissolution rates in situ with a stationary probe rotating disk electrode (SPRDE) coupled to an inductively coupled plasma mass spectrometer (ICP-MS). Generally speaking, as the electro-oxidation reaction proceeds, the platinum dissolution rate increases considerably. To guarantee Pt stability, the potential must be kept below 1.0 V vs. RHE. Interestingly, no dissolution is detectable when the electrode potential undergoes temporary self-organization, ensuring a stable and active interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of electrochemical Pt dissolution at atomic and molecular levels

Understanding and controlling electrochemical interfaces at atomic and molecular levels have transformed electrochemistry into a science with clearly defined fundamental principles leading to significant impact on various electrochemical systems and devices. Although the principles guiding the activity of electrochemical reactions are quite well established, the driving forces that control stability are still poorly understood. Here we utilize in situ monitoring of the early stages of Pt dissolution using the stationary probe rotating disk electrode technique coupled to inductively coupled plasma mass spectrometry (SPRDE-ICPMS). Our unique SPRDE-ICPMS method provides picogram sensitivity levels that, in combination with STM, provide otherwise inaccessible information about the dissolution and redeposition of Pt(111) in acidic environments. We propose two distinct dissolution mechanisms that are active during oxide formation and subsequent oxide reduction. Whereas an electrochemical dissolution mechanism is observed during anodic Pt dissolution (Pt→Pt 2+ +2e - ), a combination of electrochemical (PtO*+2H + +2e - →Pt 0 +H 2 O) and chemical (PtO*+2H + →Pt 2+ +H 2 O) steps control the dissolution of Pt during the cathodic scan. The redeposition of Pt (Pt 2+ +2e - →Pt) observed on the cathodic scan is controlled by a delicate balance between the diffusion of Pt 2+ from the double layer and redeposition of Pt 2+ on Pt oxide-free sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability limits and defect dynamics in Ag nanoparticles probed by Bragg coherent diffractive imaging

Dissolution is critical to nanomaterial stability, especially for partially dealloyed nanoparticle catalysts. Unfortunately, highly active catalysts are often not stable in their reactive environments, preventing widespread application. Thus, focusing on the structure–stability relationship at the nanoscale is crucial and will likely play an important role in meeting grand challenges. Recent advances in imaging capability have come from electron, X-ray, and other techniques but tend to be limited to specific sample environments and/or two-dimensional images. Here, we report investigations into the defect-stability relationship of silver nanoparticles to voltage-induced electrochemical dissolution imaged in situ in three dimensional detail by Bragg coherent diffractive imaging. We first determine the average dissolution kinetics by stationary probe rotating disk electrode in combination with inductively coupled plasma mass spectrometry, which allows in situ measurement of Ag+ ion formation. We then observe the dissolution and redeposition processes in single nanocrystals, providing unique insight about the role of surface strain, defects, and their coupling to the dissolution chemistry. Finally, the methods developed and the knowledge gained go well beyond a “simple” silver electrochemistry and are applicable to all electrocatalytic reactions where functional links between activity and stability are controlled by structure and defect dynamics.

36 MATERIALS SCIENCE↗