Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixel Array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A Near-Infrared Mapping Spectrometer for investigation of Jupiter and its satellites

The Near-Infrared-Mapping Spectrometer (NIMS) is one of the science instruments in the Galileo mission, which will explore Jupiter and its satellites in the mid-1990's. The NIMS experiment will map geological units on the surfaces of the Jovian satellites and characterize their mineral content; and, for the atmosphere of Jupiter, investigate cloud properties and the spatial and temporal variability of molecular abundances. The optics are gold-coated reflective and consist of a telescope and a grating spectrometer. The balance of the instrument includes a 17-detector (silicon and indium antimonide) focal plane array, a tuning fork chopper, microprocessor-controlled electronics, and a passive radiative cooler. A wobbling secondary mirror in the telescope provides 20 pixels in one dimension of spatial scanning in a pushbroom mode with 0.5 mr x 0.5 mr instantaneous field of view. The spectral range is 0.7-5.2 microns; resolution is 0.025 micron. NIMS is the first infrared experiment to combine both spatial and spectral mapping capability in one instrument.

Aptaker, Irving M.↗

Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

Bloser, P. F.↗

Update on Linear Mode Photon Counting with the HgCdTe Linear Mode Avalanche Photodiode

The behavior of the gain-voltage characteristic of the mid-wavelength infrared cutoff HgCdTe linear mode avalanche photodiode (e-APD) is discussed both experimentally and theoretically as a function of the width of the multiplication region. Data are shown that demonstrate a strong dependence of the gain at a given bias voltage on the width of the n− gain region. Geometrical and fundamental theoretical models are examined to explain this behavior. The geometrical model takes into account the gain-dependent optical fill factor of the cylindrical APD. The theoretical model is based on the ballistic ionization model being developed for the HgCdTe APD. It is concluded that the fundamental theoretical explanation is the dominant effect. A model is developed that combines both the geometrical and fundamental effects. The model also takes into account the effect of the varying multiplication width in the low bias region of the gain-voltage curve. It is concluded that the lower than expected gain seen in the first 2 × 8 HgCdTe linear mode photon counting APD arrays, and higher excess noise factor, was very likely due to the larger than typical multiplication region length in the photon counting APD pixel design. The implications of these effects on device photon counting performance are discussed.

HgCdTe↗

Spectral Analysis of the Primary Flight Focal Plane Arrays for the Thermal Infrared Sensor

Thermal Infrared Sensor (TIRS) is a (1) New longwave infrared (10 - 12 micron) sensor for the Landsat Data Continuity Mission, (2) 185 km ground swath; 100 meter pixel size on ground, (3) Pushbroom sensor configuration. Issue of Calibration are: (1) Single detector -- only one calibration, (2) Multiple detectors - unique calibration for each detector -- leads to pixel-to-pixel artifacts. Objectives are: (1) Predict extent of residual striping when viewing a uniform blackbody target through various atmospheres, (2) Determine how different spectral shapes affect the derived surface temperature in a realistic synthetic scene.

Montanaro, Matthew↗

Astronomical applications of the new Goddard Si:Bi 16 x 16 array camera system

An improved 4-18 micron array camera system has been developed at NASA Goddard Space Flight Center for astronomical protometry, using 16 x 16 Si:Bi (bismuth dope silicon) accumulation mode charge injection device (AMCID) with 256 active pixels. An astronomical observing program using this device has been carried out. The 16 x 16 device had sufficiently good sensitivity, uniformity and noise characteristics to be used for successful observations at the Steward Observatory Mt. Lemmon 60 and 61-inch telescopes in May 1983, and at the NASA Infrared Telescope Facility (IRTF) at Mauna Kea in August 1983. Initial results indicate that this detector has sensitivity and noise characteristics comparable to other devices from the same generation of Aerojet arrays.

Lamb, G.↗

Testing and characterization of an IR CBIRD FPA

High performance IR cameras are in great demand for a variety of applications, including defense (e.g. night vision, missile detection) and space (e.g. imaging at IR wavelengths). IR focal plane arrays (FPAs) are an essential component of IR cameras. An FPA is a collection of detectors at the focal plane of an imaging device, where each detector can be thought of a pixel in the image it is detecting. The FPA in this study is based on Complimentary Barrier Infrared Detectors (CBIRDs). The CBIRD FPA was tested by imaging flat black body targets at three different temperatures, 20ºC, 25ºC, and 30ºC, with images captured using SEIR software. The important figures of merit for an IR FPA, Noise Equivalent Difference Temperature (NEDT), Noise Equivalent Irradiance (NEI), detectivity (D*), responsivity, and quantum Efficiency (QE), were extracted from the image data for each individual detector using a MATLAB program, as was the array Modulation Transfer Function MTF. The test results show a mean NEDT of 16.98mK and an MTF of about 0.34 at the Nyquist frequency. Overall, the array performs well in the MWIR range and takes quality IR images.

Das, Tanya↗

Microcalorimeters for High Resolution X-Ray Spectroscopy of Laboratory and Astrophysical Plasmas

The proposal has three major objectives. The first focuses on advanced neutron-transmutation-doped (NTD)-based microcalorimeter development. Our goal is to develop an array of microcalorimeters with sub- 5 eV energy resolution that can operate with pile-up-free throughput of at least 100 Hz per pixel. The second objective is to establish our microcalorimeter as an essential x-ray diagnostic for laboratory astrophysics studies. We propose to develop a dedicated microcalorimeter spectrometer for the EBIT (electron beam ion trap). This instrument will incorporate the latest detector and cryogenic technology that we have available. The third objective is to investigate innovative ideas related to possible flight opportunities. These include compact, long lived cryo-systems, ultra-low temperature cold stages, low mass and low power electronics, and novel assemblies of thin windows with high x-ray transmission.

Silver, E.↗

Infrared astronomical imaging using a microcomputer data system

A small, portable data-acquisition and display system with a unique coprocessor was designed and built to collect data from infrared array detectors for astronomical and laboratory use. The system consists of a microcomputer board, two 12-bit analog-to-digital data-acquisition boards, a color-graphics driver board, and two coprocessor boards. The coprocessors are arithmetic logic units designed to achieve the high computation rates necessary for real-time infrared background cancellation. The system can collect data from infrared detectors of 1 to 256 pixel elements with a computation rate of 768 kHz. The software for the system was designed to collect data in the system's background, while performing other tasks in the system's foreground. The data for the detector arrays is stored in block fashion to facilitate variable image size.

Stafford, P. S.↗

Evaluation and characterization of hybrid arrays

An Infrared Camera was built for astronomical observations and for testing arrays for satellite based work. The detectors are sensitive to mid infrared wavelengths. The camera was tested at the University of Arizona 61 and 90 inch telescopes and the NASA IRTF. These tests have demonstrated a sensitivity consistent with photon shot noise with an approximately 10% quantum efficiency for each pixel when the camera was used with a 1.6% spectral filter or when used with a Fabry-Perot having a resolving power of 2000. Initial measurements of read out noise, dark current, cross talk, and hysteresis were made. The detector chip in current use is a hybrid array manufactured by the Hughes Aircraft Company. Because part of the goal was to develop and advance technology, it was decided to work with a switched MOSFET array. This architecture is very promising, and the detector parameters will be quantified carefully.

Arens, J. F.↗

(55)Fe X-ray Response of HgCdTe NIR Detector Arrays

Conversion gain is a fundamental parameter in detector characteristics that is used to measure many identifying detector properties, including read noise, dark current, and quantum efficiency (QE). Charge coupling effects, such as inter-pixel capacitance, attenuate photon shot noise and result in an overestimation of of conversion gain when implementing the photon transfer technique. The (55)Fe X-ray technique is a direct and simple method by which to measure the conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by a single X-ray photon. Here we present the calibrated pair production energy for 1.7 micron HgCdTe infrared detectors.

Fox, Ori↗

The Transition-Edge-Sensor Array for the Micro-X Sounding Rocket

The Micro-X sounding rocket program will fly a 128-element array of transition-edge-sensor microcalorimeters to enable high-resolution X-ray imaging spectroscopy of the Puppis-A supernova remnant. To match the angular resolution of the optics while maximizing the field-of-view and retaining a high energy resolution (< 4 eV at 1 keV), we have designed the pixels using 600 x 600 sq. micron Au/Bi absorbers, which overhang 140 x 140 sq. micron Mo/Au sensors. The data-rate capabilities of the rocket telemetry system require the pulse decay to be approximately 2 ms to allow a significant portion of the data to be telemetered during flight. Here we report experimental results from the flight array, including measurements of energy resolution, uniformity, and absorber thermalization. In addition, we present studies of test devices that have a variety of absorber contact geometries, as well as a variety of membrane-perforation schemes designed to slow the pulse decay time to match the telemetry requirements. Finally, we describe the reduction in pixel-to-pixel crosstalk afforded by an angle-evaporated Cu backside heatsinking layer, which provides Cu coverage on the four sidewalls of the silicon wells beneath each pixel.

Eckart, M. E.↗

Autonomous earth feature classification - Shuttle and aircraft flight test results

The Feature Identification and Location Experiment (FILE) flown on the Shuttle STS-2 mission November 12-14, 1981, tested a technique for autonomous real-time classification of selected earth features, i.e., water; bare land; vegetation; and clouds, snow, and ice. A second instrument, designed for aircraft flights, flew over regions of the west and east coasts of the United States and across the country. In each instrument, two bore-sighted CCD cameras image earth scenes in two spectral bands. Each camera includes a 100-element by 100-element detector array, and classification circuits. A simple algorithm and logic circuit provides classification decisions within a few microseconds. The experiment records the number of picture elements (pixels) representing each feature and the reflected solar radiation for each band. After flight, pixel-by-pixel classification images are constructed and compared with 70-mm color photographs taken simultaneously with the CCD-camera data.

Sivertson, W. E., Jr.↗

Near-infrared mapping of spiral barred galaxies

In external galaxies, near-infrared emission originates from stellar populations, hot dust, free-free emission from H+ regions, gaseous emission, non-thermal nucleus if any. Because of the low extinction compared to the visible, infrared wavelengths are useful to probe regions obscured by dust such as central parts where starburst phenomena can occur because of the large quantity of matter. The results presented were obtained with a 32 x 32 InSb charge injection device (CID) array cooled at 4K, at the f/36 cassegrain focus of the 3m60 Canada-France-Hawaii telescope with a spatial resolution of 0.5 inches per pixel. The objects presented are spiral barred galaxies mapped at J(1.25 microns), H(1.65 microns) and K(2.2 microns). The non-axisymetric potential due to the presence of a bar induces dynamical processes leading to the confinement of matter and peculiar morphologies. Infrared imaging is used to study the link between various components. Correlations with other wavelengths ranges and 2-colors diagrams ((J-H), (H-K)) lead to the identification of star forming regions, nucleus. Maps show structures connected to the central core. The question is, are they flowing away or toward the nucleus. Observations of M83 lead to several conclusions. The star forming region, detected in the visible and the infrared cannot be very compact and must extend to the edge of the matter concentration. The general shape of the near-infrared emission and the location of radio and 10 micron peaks suggest the confinement of matter between the inner Linblad resonances localized from CO measurements about 100 and 400 pc. The distribution of color indices in the arc from southern part to the star forming region suggests an increasing amount of gas and a time evolution eventually triggered by supernova explosions. Close to the direction of the bar, a bridge-like structure connects the arc to the nucleus with peculiar color indices. Perhaps, this structure can be linked to a height velocity component seen in UV and we can attribute it to a jet and/or a matter flow along the bar toward the nucleus, fuelling it. NGC 1068 is the nearest Seyfert 2 galaxy. It has been a subject of many studies at all wavelengths. This object was mapped at J, H, K, L and M, and in polaro-imagery. Results are given.

Gallais, P.↗

Supercomputing 2002: NAS Demo Abstracts

The hyperwall is a new concept in visual supercomputing, conceived and developed by the NAS Exploratory Computing Group. The hyperwall will allow simultaneous and coordinated visualization and interaction of an array of processes, such as a the computations of a parameter study or the parallel evolutions of a genetic algorithm population. Making over 65 million pixels available to the user, the hyperwall will enable and elicit qualitatively new ways of leveraging computers to accomplish science. It is currently still unclear whether we will be able to transport the hyperwall to SC02. The crucial display frame still has not been completed by the metal fabrication shop, although they promised an August delivery. Also, we are still working the fragile node issue, which may require transplantation of the compute nodes from the present 2U cases into 3U cases. This modification will increase the present 3-rack configuration to 5 racks.

Parks, John↗

Integrated sensor with frame memory and programmable resolution for light adaptive imaging

An image sensor operable to vary the output spatial resolution according to a received light level while maintaining a desired signal-to-noise ratio. Signals from neighboring pixels in a pixel patch with an adjustable size are added to increase both the image brightness and signal-to-noise ratio. One embodiment comprises a sensor array for receiving input signals, a frame memory array for temporarily storing a full frame, and an array of self-calibration column integrators for uniform column-parallel signal summation. The column integrators are capable of substantially canceling fixed pattern noise.

Zhou, Zhimin↗

Flight Qualified Micro Sun Sensor

A prototype small, lightweight micro Sun sensor (MSS) has been flight qualified as part of the attitude-determination system of a spacecraft or for Mars surface operations. The MSS has previously been reported at a very early stage of development in NASA Tech Briefs, Vol. 28, No. 1 (January 2004). An MSS is essentially a miniature multiple-pinhole electronic camera combined with digital processing electronics that functions analogously to a sundial. A micromachined mask containing a number of microscopic pinholes is mounted in front of an active-pixel sensor (APS). Electronic circuits for controlling the operation of the APS, readout from the pixel photodetectors, and analog-to-digital conversion are all integrated onto the same chip along with the APS. The digital processing includes computation of the centroids of the pinhole Sun images on the APS. The spacecraft computer has the task of converting the Sun centroids into Sun angles utilizing a calibration polynomial. The micromachined mask comprises a 500-micron-thick silicon wafer, onto which is deposited a 57-nm-thick chromium adhesion- promotion layer followed by a 200-nm-thick gold light-absorption layer. The pinholes, 50 microns in diameter, are formed in the gold layer by photolithography. The chromium layer is thin enough to be penetrable by an amount of Sunlight adequate to form measurable pinhole images. A spacer frame between the mask and the APS maintains a gap of .1 mm between the pinhole plane and the photodetector plane of the APS. To minimize data volume, mass, and power consumption, the digital processing of the APS readouts takes place in a single field-programmable gate array (FPGA). The particular FPGA is a radiation- tolerant unit that contains .32,000 gates. No external memory is used so the FPGA calculates the centroids in real time as pixels are read off the APS with minimal internal memory. To enable the MSS to fit into a small package, the APS, the FPGA, and other components are mounted on a single two-sided board following chip-on-board design practices

Liebe, Carl Christian↗

Electromagnetic Considerations for Planar Bolometer Arrays in the Single Mode Limit

Filled arrays of planar bolometers are finding astronomical applications at wavelengths as long as several millimeters. In an effort to keep focal planes to a reasonable size while maintaining large numbers of detectors, a common strategy is to push these arrays to operate close to or at the single mode limit. Doing so introduces several new challenges that are not experienced in the multi-mode case of far-infrared detectors having similar pixel sizes. First, diffractive effects of the pixels themselves are no longer insignificant and will ultimately contribute to the resolution limit of the optical system in which they reside. We use the method of Withlngton et al. (2003) to model the polarized diffraction in this limit. Second, it is necessary to re-examine the coupling between the radiation and the absorbing element that is thermally connected to the bolometers. The small f-numbers that are often employed to make use of large focal planes makes backshort construction problematic. We introduce a new strategy to increase detector efficiency that uses an antireflective layer on the front side of the detector array. In addition, typical methods for stray light control that rely on multiple reflections in a lossy medium fail due to physical size constraints. For this application, we find that resonant absorbers are a more effective strategy that can be implemented in the space available.

Wollack, Edward J.↗

Diagnostic and quality-assurance tools for low-contrast images obtained from array detectors

We investigate methods of estimating a background image frame for subtraction from a data frame for use when a more suitable measured background frame is not available. We define background as any signal component that is not attributable to the phenomenon currently under investigation. We describe a technique that is based on pixel-by-pixel least-squares regression of images for computing a background frame from available data. We argue that the same technique can be a useful quality-assurance tool for evaluating instrument performance. For example, it can help to separate image structure resulting from the reading process from structure resulting from the characteristics of the detector itself. We demonstrate that background estimation can be nontrivial by comparing the results of different background estimation procedures by using data obtained from a CCD array detector. We investigate the temperature-dependent contributions of the detector and readout electronics to the total signal as a demonstration of the diagnostic capabilities of least-squares image regression.

Hatfield, D. B.↗