Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A COMPARISON OF SPECTROSCOPIC VERSUS IMAGING TECHNIQUES FOR DETECTING CLOSE COMPANIONS TO KEPLER OBJECTS OF INTEREST

Kepler planet candidates require both spectroscopic and imaging follow-up observations to rule out false positives and detect blended stars. Traditionally, spectroscopy and high-resolution imaging have probed different host star companion parameter spaces, the former detecting tight binaries and the latter detecting wider bound companions as well as chance background stars. In this paper, we examine a sample of 11 Kepler host stars with companions detected by two techniques—near-infrared adaptive optics and/or optical speckle interferometry imaging, and a new spectroscopic deblending method. We compare the companion effective temperatures (T{sub eff}) and flux ratios (F{sub B}/F{sub A}, where A is the primary and B is the companion) derived from each technique and find no cases where both companion parameters agree within 1σ errors. In 3/11 cases the companion T{sub eff} values agree within 1σ errors, and in 2/11 cases the companion F{sub B}/F{sub A} values agree within 1σ errors. Examining each Kepler system individually considering multiple avenues (isochrone mapping, contrast curves, probability of being bound), we suggest two cases for which the techniques most likely agree in their companion detections (detect the same companion star). Overall, our results support the advantage that the spectroscopic deblending technique has for finding very close-in companions (θ ≲ 0.″02–0.″05) that are not easily detectable with imaging. However, we also specifically show how high-contrast AO and speckle imaging observations detect companions at larger separations (θ ≥ 0.″02–0.″05) that are missed by the spectroscopic technique, provide additional information for characterizing the companion and its potential contamination (e.g., position angle, separation, magnitude differences), and cover a wider range of primary star effective temperatures. The investigation presented here illustrates the utility of combining the two techniques to reveal higher-order multiples in known planet-hosting systems.

79 ASTRONOMY AND ASTROPHYSICS↗

STAR Vertex Detector Upgrade-HFT Pixel Development

Development and prototyping efforts directed towards construction of a new vertex detector for the STAR experiment at the RHIC accelerator at BNL are presented. This new detector will extend the physics range of STAR by allowing for precision measurements of yields and spectra of particles containing heavy quarks. The innermost central part of the new detector is a high resolution pixel-type detector (PIXEL). PIXEL requirements are discussed as well as a conceptual mechanical design, a sensor development path, and a detector readout architecture. Selected progress with sensor prototypes dedicated to the PIXEL detector is summarized and the approach chosen for the readout system architecture validated in tests of hardware prototypes is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The essential genome of a bacterium

Caulobacter crescentus is a model organism for the integrated circuitry that runs a bacterial cell cycle. Full discovery of its essential genome, including non-coding, regulatory and coding elements, is a prerequisite for understanding the complete regulatory network of a bacterial cell. Using hypersaturated transposon mutagenesis coupled with high-throughput sequencing, we determined the essential Caulobacter genome at 8 bp resolution, including 1012 essential genome features: 480 ORFs, 402 regulatory sequences and 130 non-coding elements, including 90 intergenic segments of unknown function. The essential transcriptional circuitry for growth on rich media includes 10 transcription factors, 2 RNA polymerase sigma factors and 1 anti-sigma factor. We identified all essential promoter elements for the cell cycle-regulated genes. The essential elements are preferentially positioned near the origin and terminus of the chromosome. The high resolution strategy used here is applicable to high-throughput, full genome essentiality studies and large-scale genetic perturbation experiments in a broad class of bacterial species.

59 BASIC BIOLOGICAL SCIENCES↗

Three-dimensional scanning transmission electron microscopy of biological specimens

A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2 - 3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original data set. The precision of the height determination was 0.2 nm. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy (TEM). However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved data set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal structure of a novel non-Pfam protein PF2046 solved using low resolution B-factor sharpening and multi-crystal averaging methods

Sometimes crystals cannot diffract X-rays beyond 3.0 {angstrom} resolution due to the intrinsic flexibility associated with the protein. Low resolution diffraction data not only pose a challenge to structure determination, but also hamper interpretation of mechanistic details. Crystals of a 25.6 kDa non-Pfam, hypothetical protein, PF2046, diffracted X-rays to 3.38 {angstrom} resolution. A combination of Se-Met derived heavy atom positions with multiple cycles of B-factor sharpening, multi-crystal averaging, restrained refinement followed by manual inspection of electron density and model building resulted in a final model with a R value of 23.5 (R{sub free} = 24.7). The asymmetric unit was large and consisted of six molecules arranged as a homodimer of trimers. Analysis of the structure revealed the presence of a RNA binding domain suggesting a role for PF2046 in the processing of nucleic acids.

59 BASIC BIOLOGICAL SCIENCES↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

License Structure for Multi-Module Facilities

The Next Generation Nuclear Plant (NGNP) Project is intended to be the prototype for multi-module commercial high temperature gas reactors (HTGRs) for process heat and/or electricity generation. Part of the objectives of the project are to establish the conditions that would govern or enhance the design, licensing, construction and operation of numerous, modular nuclear plants, particularly suited for industrial applications or that could reduce the risk of such projects. A determination is desired regarding whether a multi-module reactor plant can be licensed with a single Nuclear Regulatory Commission (NRC) review, hearing, and safety evaluation report. If it is determined that a multi-modular reactor plant can be licensed under a single review/hearing process, the structure and the duration of the license for each module will also need to be determined. The purpose of this paper is to describe for the NRC the NGNP position on these two issues and obtain either NRC general concurrence or comments on the approach to these issues. While the current NGNP planning provides for only a single reactor module, the project is intended to provide the basis and establish a licensing framework that can be used by future commercial HTGRs and other reactor designs, including a variety of small modular reactor technologies, with configurations reflecting design standardization of multi-module plants. Therefore, it is important to identify a path for addressing these modular reactor plant issues so that the resolution can be factored into the NGNP Project planning. The NGNP position is that a single combined license (COL) application can be submitted for a multi-modular reactor facility, the COL application can undergo a single NRC review/hearing process, and each module should be issued a separate license.

99 GENERAL AND MISCELLANEOUS↗

An Asymmetric Dust Ring around a Very Low Mass Star ZZ Tau IRS

We present Atacama Large Millimeter/submillimeter Array (ALMA) gas and dust observations at band 7 (339 GHz: 0.89 mm) of the protoplanetary disk around a very low mass star ZZ Tau IRS with a spatial resolution of 025. The {sup 12}CO J = 3 → 2 position–velocity diagram suggests a dynamical mass of ZZ Tau IRS of ∼0.1–0.3 M {sub ☉}. The disk has a total flux density of 273.9 mJy, corresponding to an estimated mass of 24–50 M {sub ⊕} in dust. The dust emission map shows a ring at r = 58 au and an azimuthal asymmetry at r = 45 au with a position angle of 135°. The properties of the asymmetry, including radial width, aspect ratio, contrast, and contribution to the total flux, were found to be similar to the asymmetries around intermediate mass stars (∼2 M {sub ☉}) such as MWC 758 and IRS 48. This implies that the asymmetry in the ZZ Tau IRS disk shares a similar origin with others, despite the star being ∼10 times less massive. Our observations also suggest that the inner and outer parts of the disk may be misaligned. Overall, the ZZ Tau IRS disk shows evidence of giant planet formation on a ∼10 au scale at a few megayears. If confirmed, it will challenge existing core accretion models in which such planets have been predicted to be extremely hard to form around very low mass stars.

74 ATOMIC AND MOLECULAR PHYSICS↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution Structures of HIV-1 Reverse Transcriptase/TMC278 Complexes: Strategic Flexibility Explains Potency Against Resistance Mutations

TMC278 is a diarylpyrimidine (DAPY) nonnucleoside reverse transcriptase inhibitor (NNRTI) that is highly effective in treating wild-type and drug-resistant HIV-1 infections in clinical trials at relatively low doses ({approx}25-75 mg/day). We have determined the structure of wild-type HIV-1 RT complexed with TMC278 at 1.8 Angstroms resolution, using an RT crystal form engineered by systematic RT mutagenesis. This high-resolution structure reveals that the cyanovinyl group of TMC278 is positioned in a hydrophobic tunnel connecting the NNRTI-binding pocket to the nucleic acid-binding cleft. The crystal structures of TMC278 in complexes with the double mutant K103N/Y181C (2.1 Angstroms ) and L100I/K103N HIV-1 RTs (2.9 Angstroms ) demonstrated that TMC278 adapts to bind mutant RTs. In the K103N/Y181C RT/TMC278 structure, loss of the aromatic ring interaction caused by the Y181C mutation is counterbalanced by interactions between the cyanovinyl group of TMC278 and the aromatic side chain of Y183, which is facilitated by an {approx}1.5 Angstroms shift of the conserved Y183MDD motif. In the L100I/K103N RT/TMC278 structure, the binding mode of TMC278 is significantly altered so that the drug conforms to changes in the binding pocket primarily caused by the L100I mutation. The flexible binding pocket acts as a molecular 'shrink wrap' that makes a shape complementary to the optimized TMC278 in wild-type and drug-resistant forms of HIV-1 RT. The crystal structures provide a better understanding of how the flexibility of an inhibitor can compensate for drug-resistance mutations.

36 MATERIALS SCIENCE↗

Development of large area, pico-second resolution photo-detectors and associated readout electronics

The Large Area Pico-second Photo-detectors described in this contribution incorporate a photo-cathode and a borosilicate glass capillary Micro-Channel Plate (MCP) pair functionalized by atomic layer deposition (ALD) of separate resistive and electron secondary emitters materials. They may be used for biomedical imaging purposes, a remarkable opportunity to apply technologies developed in HEP having the potential to make major advances in the medical world, in particular for Positron Emission Tomography (PET). If daisy-chained and coupled to fast transmission lines read at both ends, they could be implemented in very large dimensions. Initial testing with matched pairs of small glass capillary test has demonstrated gains of the order of 105 to 106. Compared to other fast imaging devices, these photo-detectors are expected to provide timing resolutions in the 10-100 ps range, and two-dimension position in the sub-millimeter range. A 6-channel readout ASIC has been designed in 130 nm CMOS technology and tested. As a result, fast analog sampling up to 17 GS/s has been obtained, the intrinsic analog bandwidth being presently under evaluation. The digitization in parallel of several cells in two microseconds allows getting off-chip digital data read at a maximum rate of 40 MHz. Digital Signal Processing of the sampled waveforms is expected achieving the timing and space resolutions obtained with digital oscilloscopes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital tomosynthesis (DTS) for verification of target position in early stage lung cancer patients

Purpose: The ability to verify intrafraction tumor position is clinically useful for hypofractionated treatments. Short arc kV digital tomosynthesis (DTS) could facilitate more frequent target verification. The authors used DTS combined with triangulation to determine the mean temporal position of small-volume lung tumor targets treated with stereotactic radiotherapy. DTS registration results were benchmarked against online clinical localization using registration between free-breathing cone-beam computed tomography (CBCT) and the average intensity projection (AvIP) of the planning 4DCT.Methods: In this retrospective study, 76 sets of kV-projection images from online CBCT scans of 13 patients were used to generate DTS image slices (CB-DTS) with nonclinical research software (DTS Toolkit, Varian Medical Systems). Three-dimensional tumor motion was 1.3–4 mm in six patients and 6.1–25.4 mm in seven patients on 4DCT (significant difference in the mean of the groups, P < 0.01). The 4DCT AvIP was used to digitally reconstruct the Reference-DTS. DTS registration and DTS registration combined with triangulation were investigated. Progressive shortening of total DTS arc lengths from 95° to 35° around 0° gantry position was evaluated for different scenarios: DTS registration using the entire arc; DTS registration plus triangulation using two nonoverlapping arcs; and for 55° and 45° total gantry rotation, DTS registration plus triangulation using two overlapping arcs. Finally, DTS registration plus triangulation performed at eight gantry angles, each separated by 45° was evaluated using full fan kV projection data for one patient with an immobile tumor and five patients with mobile tumors.Results: For DTS registration alone, shortening arc length did not influence accuracy in X- and Y-directions, but in Z-direction, mean deviations from online CBCT localization systematically increased for shorter arc length (P < 0.05). For example, using a 95° arc mean DTS-CBCT difference was 0.8 mm (1 SD = 0.6 mm) and for a 35° arc the mean was 2.4 mm (1 SD = 1.7 mm). DTS plus triangulation using nonoverlapping-arcs increased accuracy in Z-direction for tested arc lengths ≤55° (P < 0.01). Overlapping arcs increased accuracy in Y-direction for tumors with motion >4 mm (P < 0.02) but increased Z-direction accuracy was only observed with 55° total gantry rotation. The 95th percentile deviations with this overlapping technique in X-, Y-, and Z-directions were 1.3, 2.0, and 2.5 mm, respectively. For the five patients with mobile tumors where DTS + triangulation was performed with 45° intervals, the pooled deviation from online CBCT correction showed, for X-, Y-, and Z-directions, mean of 1.1 mm, standard deviations (SD) of 0.9, 1.0, and 0.9 mm, respectively. The mean + 2 SD was <3 mm for each direction.Conclusions: Short-arc DTS verification of time averaged lung tumor position is feasible using free-breathing kV projection data and the AvIP of the 4DCT as a reference. Observed differences between DTS and online CBCT registration with AvIP were ≤3 mm (mean + 2 SD), however, the increased temporal resolution of DTS + triangulation also identified short period deviations from the average target position on the CBCT. Short-arc DTS appears promising for intrafraction tumor position monitoring during stereotactic lung radiotherapy delivered with a rotational technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Timing Jitter Characterization at the NSLS SDL

Two novel timing jitter measurement techniques with a 100 fs resolution are presented in this paper. The first technique based on the Schottky effect, is used to measure the timing jitter between the photoinjector drive laser and the RF system; and it was employed to characterize the environment effects on the timing jitter. The I/Q beam monitor based on a stripline beam position monitor (BPM) is used to characterize the electron beam arrival time jitter.

43 PARTICLE ACCELERATORS↗

DIURNAL CYCLE OF PRECIPITABLE WATER VAPOR OVER SPAIN

Despite the importance of the diurnal cycle of precipitable water vapor (PWV), its knowledge is very limited due to the lack of data with sufficient temporal resolution. Currently, from GPS receivers, PWV can be obtained with high temporal resolution in all weather conditions for all hours of the day. In this study we have calculated the diurnal cycle of PWV for ten GPS stations over Spain. The minimum value is reached approximately at the same time at all the stations, ~0400-0500 UTC, whereas the maximum is reached in the second half of the day, but with a larger dispersion of its occurrence between stations. The amplitude of the cycle ranges between 0.72 mm and 1.78 mm. The highest values are recorded at the stations on the Mediterranean coast, with a doubling of the values of the stations on the Atlantic coast or inland. The amplitude of the PWV cycle, relative to the annual mean value, ranges between 8.8 % on the Mediterranean coast and 3.6 % on the Atlantic coast. Two distinctly different seasonal diurnal cycles have been identified, one in winter and other in summer, with spring and autumn being only transition states. The winter cycle is quite similar at all locations, whereas in summer, local effects are felt strongly, making the diurnal cycle quite different between stations. The amplitude of the summer cycle is 1.69 mm, it is almost double the winter one (0.93 mm). Analogous to the annual cycles, the seasonal cycles of the different stations are more similar during the night and early morning hours than during the afternoon. The observed features of the PWV diurnal cycle are explained in a qualitative way on the basis of the air temperature, the transport of moisture by local winds, and the turbulent vertical mixing.

54 ENVIRONMENTAL SCIENCES↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

Laser Doppler field sensor for high resolution flow velocity imaging without camera

In this paper we present a laser sensor for highly spatially resolved flow imaging without using a camera. The sensor is an extension of the principle of laser Doppler anemometry (LDA). Instead of a parallel fringe system, diverging and converging fringes are employed. This method facilitates the determination of the tracer particle position within the measurement volume and leads to an increased spatial and velocity resolution compared to conventional LDA. Using a total number of four fringe systems the flow is resolved in two spatial dimensions and the orthogonal velocity component. Since no camera is used, the resolution of the sensor is not influenced by pixel size effects. A spatial resolution of 4 {mu}m in the x direction and 16 {mu}m in the y direction and a relative velocity resolution of 1x10{sup -3} have been demonstrated up to now. As a first application we present the velocity measurement of an injection nozzle flow. The sensor is also highly suitable for applications in nano- and microfluidics, e.g., for the measurement of flow rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

What are the current limits on determination of protonation state using neutron macromolecular crystallography?

The rate of deposition of models determined by neutron diffraction, or a hybrid approach that combines X-ray and neutron diffraction, has increased in recent years. The benefit of neutron diffraction is that hydrogen atom (H) positions are detectable, allowing for the determination of protonation state and water molecule orientation. This study analyses all neutron models deposited in the Protein Data Bank to date, focusing on protonation state and properties of H (or deuterium, D) atoms as well as the details of water molecules. In particular, clashes and hydrogen bonds involving H or D atoms are investigated. As water molecules are typically the least reproducible part of a structural model, their positions in neutron models were compared to those in homologous high-resolution X-ray structures. For models determined by joint refinement against X-ray and neutron data, the water structure comparison was also carried out for models re-refined against the X-ray data alone. The homologues have generally fewer conserved water molecules where X-ray only was used and the positions of equivalent waters vary more than in the case of the hybrid X-ray model. As neutron diffraction data are generally less complete than X-ray data, the influence of neutron data completeness on nuclear density maps was also analyzed. Here, we observe and discuss systematic map quality deterioration as result of data incompleteness.

Hydrogen bond↗

Multiresolution Localization with Temporal Scanning for Super-Resolution Diffuse Optical Imaging of Fluorescence

A super-resolution optical imaging method is introduced that relies on the distinct temporal information associated with each fluorescent optical reporter to determine its spatial position to high precision with measurements of heavily scattered light. This multiple-emitter localization approach uses a diffusion equation forward model in a cost function, and has the potential to achieve micron-scale spatial resolution through centimeters of tissue. Utilizing some degree of temporal separation for the reporter emissions, position and emission strength are determined using a computationally efficient time stripping multiresolution algorithm. The method circumvents the spatial resolution challenges faced by earlier optical imaging approaches using a diffusion equation forward model, and is promising for in vivo applications. For example, in principle, the approach could be used to localize individual neurons firing throughout a rodent brain, enabling direct imaging of neural network activity.

42 ENGINEERING↗