Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Interference effects of thrust reversing on horizontal tail effectiveness of twin-engine fighter aircraft at Mach numbers from 0.15 to 0.90

An investigation was conducted in the Langley 16 foot Transonic Tunnel to determine the interference effects of thrust reversing on horizontal tail effectiveness of a twin engine, general research fighter model at approach and in-flight speeds. Twin vertical tails at three longitudinal locations were tested at a cant angle of 0 deg. One configuration was also tested at a cant angle of 20 deg. Two nonaxisymmetric nozzle reverser concepts were studied. Test data were obtained at Mach numbers of 0.15, 0.60, and 0.90 and at angles of attack from -3 to 9 deg. Nozzle pressure ratios varied from jet off to 7.0, depending upon Mach number. At landing approach speed (Mach number 0.15), thrust reverser operation usually resulted in large variations (up to 70% increase) in horizontal tail effectiveness as nozzle pressure ratio was varied at zero angle of attack or as angle of attack was varied at constant nozzle pressure ratio. There was always a decrease in effectiveness at Mach numbers of 0.60 and 0.90 as a result of reverser operation.

Capone, F. J.↗

Measurements of Unsteady Wake Interference Between Tandem Cylinders

A multi-phase, experimental study in the Basic Aerodynamics Research Tunnel at the NASA Langley Research Center has provided new insight into the unsteady flow interaction around cylinders in tandem arrangement. Phase 1 of the study characterized the mean and unsteady near-field flow around two cylinders of equal diameter using 2-D Particle Image Velocimetry (PIV) and hot-wire anemometry. These measurements were performed at a Reynolds number of 1.66 x 10(exp 5), based on cylinder diameter, and spacing-to-diameter ratios, L/D, of 1.435 and 3.7. The current phase, Phase 2, augments this dataset by characterizing the surface flow on the same configurations using steady and unsteady pressure measurements and surface flow visualization. Transition strips were applied to the front cylinder during both phases to produce a turbulent boundary layer upstream of the flow separation. For these flow conditions and L/D ratios, surface pressures on both the front and rear cylinders show the effects of L/D on flow symmetry, pressure recovery, and the location of flow separation and attachment. Mean streamlines and instantaneous vorticity obtained from the PIV data are used to explain the flow structure in the gap and near-wake regions and its relationship to the unsteady surface pressures. The combination of off-body and surface measurements provides a comprehensive dataset to develop and validate computational techniques for predicting the unsteady flow field at higher Reynolds numbers.

Jenkins, Luther N.↗

Evaluation of an Interferometric Sensor for In-Space Detection of Gas Leaks

Space mission planning often involves long-term storage of volatile liquids or high-pressure gases. These may include cryogenic fuels and oxidizers, high-pressure gases, and life-support-critical consumables. The risk associated with the storage of fluids and gases in space systems has long been an issue and the ability to retain these fluids is often tied to mission success. A leak in the storage or distribution system can cause many different problems, including a simple, but mission endangering, loss of inventory or, in severe cases, unbalanced thrust loads on a flight vehicle. Cryogenic propellants are especially difficult to store, especially over a long duration. The propellant can boil off and be lost through the insulating walls of the tank or simple thermal cycling of the fittings, valves, and propellant feed lines may unseat seals allowing the fluid to escape. Current NASA missions call for long-duration in-space storage of propellants, oxidizers, and life support supplies. Leaks of a scale detectable through a pressure drop in the storage tank are often catastrophic and have long been the focus of ground-based mitigation efforts where redundant systems are often employed. However, there is presently no technology available for detecting and monitoring low-level, but still mission-endangering, gas leaks in space. Standard in-space gas detection methods either have a very limited pressure range over which they operate effectively or are limited to certain gases. Mass spectrometer systems are able to perform the detection tasks, but their size, mass and use of high voltage, which could potentially lead to an arc that ignites a combustible propellent, severely limit their usefulness in a space system. In this paper, we present results from testing of the light-based interferometric gas monitoring and leak detection sensor shown in Fig. 1. The output of the sensor is an interference fringe pattern that is a function of the gas density, and commensurate index of refraction, in the sample region. Changes in the density of gas cause the interference fringes to move across a photodiode detector, providing a temporal history of the leak. The sensor is fiber coupled and constructed from solid optics, allowing for placement almost anywhere on the spacecraft. It is also advantageous in that it consumes very little power and does not introduce an ignition source. Data are presented demonstrating the capability of the sensor to measure density variations in different gas species. In addition, the transient response of the sensor in vacuum is demonstrated. These data extend and improve upon the results previously presented by the authors in Ref. [1].

Polzin, Kurt A.↗

Employing Automated Experimental Evolution to Understand Survival Strategies of Lab-Grown Extremophiles

Experimental evolution (EE) exposes microbes to intentional stressors to improve resistance through artificial mutation. The resulting changes to metabolic pathways, protein structure, and genetic sequences, along with traditional genetic engineering tools, to can help understand the mechanisms of improved tolerance. An automated experimental set-up -- the Automated Adaptive Directed Evolution Chamber (AADEC) -- with minimal scope for human interference was developed at NASA Ames. A second- generation device integrating more real-time biochemical sensors has been developed recently. Added sensors include pH for indicating metabolic products, oxidation-reduction potential (ORP) for indicating available/consumed metabolic energy, dissolved oxygen (DO) for indicating aerobic/anaerobic growth cycles, and electrical conductivity (EC) as an additional indicator of metabolic products. With four additional sensors, the system is biochemically more informative in real-time. More importantly, each sensor parameter can be used as a selection pressure, individually or in combination with others, to artificially create and control inhospitable environments analogous to extremophile habitats for microbial growth in the lab. Potential stressors to be added in the future include thermal, reactive oxygen species, metal-ion concentrations, and varying nutrient availability.

Automated↗

Electromagnetic scattering from a spherical polydispersion of coated spheres

The volume averaged cross sections for extinction, scattering, absorption, and radiation pressure along with the elements of the phase matrix were computed for a spherical polydispersion of water coated carbon particles. The wavelength used was 4910 A. The thickness of the water coating was held constant over the polydispersion, while the ratio of core radius to total radius was varied, or the ratio was held constant over the polydispersion, while the thickness of the coating varied. The results show large differences in both the intensity and degree of polarization between dry and wet aerosols. Also interference phenomena can occur, which demonstrate that the assignment of an average refractive index to aerosols can be misleading and can lead to erroneous results.

Kattawar, G. W.↗

Thrust reversing effects on horizontal tail effectiveness of twin-engine fighter aircraft

The Langley Research Center has conducted an experimental program to determine the interference effects of thrust reversing on horizontal tail effectiveness of a twin engine, general research fighter model at approach (Mach number 0.15) and in-flight (Mach number 0.60 and 0.90) speeds. Twin vertical tails were tested at three longitudinal locations. Two nonaxisymmetric nozzle reverser concepts were studied. The effects of thrust reversing on horizontal tail effectiveness were found to be very dependent upon vertical tail locations. At approach speeds thrust reverser operation usually resulted in large variations in horizontal tail effectiveness as either nozzle pressure ratio or model angle of attack was varied. Either increases or decreases in tail effectiveness ocurred due to reverse operation depending upon tail location. At in-flight conditions there were always decreases in tail effectiveness due to reverser operation regardless of vertical tail location.

Capone, F. J.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

It is essential to provide adequate carbon dioxide (CO2) washout in a space suit to reduce the risks associated with manned operations in space suits. Symptoms of elevated CO2 levels range from reduced cognitive performance and headache to unconsciousness and death at high levels of CO2. Because of this, NASA imposes limits on inspired CO2 levels for space suits when they are used in space and for ground testing. Testing and/or analysis must be performed to verify that a space suit meets CO2 washout requirements. Testing for developmental space suits has traditionally used an oronasal mask that collects CO2 samples at the left and rights sides of the mouth. Testing with this mask resulted in artificially elevated CO2 concentration measurements, which is most likely due to the dead space volume at the front of the mask. The mask also extends outward and into the supply gas stream, which may disrupt the washout effect of the suit supply gas. To mitigate these problems, a nasal cannula was investigated as a method for measuring inspired CO2 based on the assumptions that it is low profile and would not interfere with the designed suit gas flow path, and it has reduced dead space. This test series compared the performance of a nasal cannula to the oronasal mask in the Mark III space suit. Inspired CO2 levels were measured with subjects at rest and at metabolic workloads of 1000, 2000, and 3000 BTU/hr. Workloads were achieved by use of an arm ergometer or treadmill. Test points were conducted at air flow rates of 2, 4, and 6 actual cubic feet per minute, with a suit pressure of 4.3 psid. Results from this test series will evaluate the accuracy and repeatability across subjects of the nasal cannula collection method, which will provide rationale for using a nasal cannula as the new method for measuring inspired CO2 in a space suit. Proper characterization of sampling methods and of suit CO2 washout capability will better inform requirements definition and verification techniques for future CO2 washout limits in space suits

Meginnis, I↗

Computational and experimental studies of light twin aerodynamic interference

The results of an analytical and experimental study of aerodynamic interference effects for a light twin aircraft are presented. Both the influence of a body (either fuselage or nacelle) on a wing and the influence of a wing on a body are studied. The wing studied uses a new natural laminar flow airfoil with variable camber movable trailing edge. A three-dimensional panel method program utilizing surface source and surface doublet singularities was used to design wing-nacelle and wing-fuselage fairings. Experiments were conducted using a 1/6 scale reflection plane model. Forces, pressures, and surface flow visualization results are presented. Results indicate that potential flow analysis is useful to guide the design of intersection fairings, but experimental tuning is still required. While the study specifically addressed a light twin aircraft, the methods are applicable to a wide variety of aircraft.

Thomson, W. G.↗

Chemical kinetic studies of atmospheric reactions using tunable diode laser spectroscopy

IR absorption using tunable diode laser spectroscopy provides a sensitive and quantitative detection method for laboratory kinetic studies of atmospheric trace gases. Improvements in multipass cell design, real time signal processing, and computer controlled data acquisition and analysis have extended the applicability of the technique. We have developed several optical systems using off-axis resonator mirror designs which maximize path length while minimizing both the sample volume and the interference fringes inherent in conventional 'White' cells. Computerized signal processing using rapid scan (300 kHz), sweep integration with 100 percent duty cycle allows substantial noise reduction while retaining the advantages of using direct absorption for absolute absorbance measurements and simultaneous detection of multiple species. Peak heights and areas are determined by curve fitting using nonlinear least square methods. We have applied these techniques to measurements of: (1) heterogeneous uptake chemistry of atmospheric trace gases (HCl, H2O2, and N2O5) on aqueous and sulfuric acid droplets; (2) vapor pressure measurements of nitric acid and water over prototypical stratospheric aerosol (nitric acid trihydrate) surfaces; and (3) discharge flow tube kinetic studies of the HO2 radical using isotopic labeling for product channel and mechanistic analysis. Results from each of these areas demonstrate the versatility of TDL absorption spectroscopy for atmospheric chemistry applications.

Worsnop, Douglas R.↗

Study of Buoyancy Effects in Diffusion Flames Using Rainbow Schlieren Deflectometry

Diffusion flames are extensively encountered in many domestic and industrial processes. Even after many decades of research, a complete understanding of the diffusion flame structure is not available. The structure and properties of the flames are governed by the mixing (laminar or turbulent), chemical kinetics, radiation and soot processes. Another important phenomenon that affects flame structure in normal gravity is buoyancy. The presence of buoyancy has long hindered the rational understanding of many combustion processes. In gas jet diffusion flames, buoyancy affects the structure of the shear layer, the development of fluid instabilities, and formation of the coherent structures in the near nozzle region of the gas jets. The buoyancy driven instabilities generate vorticial structures outside the flame resulting in flame flicker. The vortices also strongly interact with the small-scale structures in the jet shear layer. This affects the transitional and turbulence characteristics of the flame. For a fundamental understanding of diffusion flames it is essential to isolate the effects of buoyancy. This is the primary goal of the experiments conducted in microgravity. Previous investigations, have shown dramatic differences between the jet flames in microgravity and normal gravity. It has been observed that flames in microgravity are taller and more sooty than in normal gravity. The fuels used in these experiments were primarily hydrocarbons. In the absence of buoyancy the soot resides near the flame region, which adversely affects the entrainment of reactants. It is very important to eliminate the interference of soot on flame characteristics in microgravity. The present work, therefore, focuses on the changes in the flame structure due to buoyancy without the added complexities of heterogeneous reactions. Clean burning hydrogen is used as the fuel to avoid soot formation and minimize radiative losses. Because of the low luminosity of hydrogen flames, we use rainbow schlieren deflectometry for visualization. The visualized images are digitized for quantification.The work reported here is divided into three sections; rainbow schlieren deflectometry (RSD), microgravity experiments and sub-atmospheric pressure experiments. The first section demonstrates the application of RSD for quantitative measurements in non-reacting and reacting flow systems. A computational effort to complement the experimental work is also included. In the second section, the experiments conducted at the 2.2s NASA Lewis Drop tower facility are described. The experiments were conducted to study the behavior of laminar, transitional and turbulent hydrogen flames in microgravity. The ability of RSD technique to provide quantitative data is highlighted. The final section deals with the sub-atmospheric pressure tests, which demonstrate that buoyancy in hydrogen diffusion flames can be scaled with pressure at normal gravity.

Agrawal, Ajay K.↗

Model of a Piezoelectric Transducer

It's difficult to control liquid and gas in propellant tanks in zero gravity. A possible a design would utilize acoustic liquid manipulation (ALM) technology which uses ultrasonic beams conducted through a liquid and solid media, to push gas bubbles in the liquid to desirable locations. We can propel and control the bubble with acoustic radiation pressure by aiming the acoustic waves on the bubble s surface. This allows us to design a so called smart tank in which the ALM devices transfer the gas to the outer wall of the tank and isolating the liquid in the center. Because the heat transfer rate of a gas is lower of that of the liquid it would substantially decrease boil off and provide of for a longer storage life. The ALM beam is composed of little wavelets which are individual waves that constructively interfere with each other to produce a single, combined acoustic wave front. This is accomplished by using a set of synchronized ultrasound transducers arranged in an array. A slight phase offset of these elements allows us to focus and steer the beam. The device that we are using to produce the acoustic beam is called the piezoelectric transducer. This device converts electrical energy to mechanical energy, which appears in the form of acoustic energy. Therefore the behavior of the device is dependent on both the mechanical characteristics, such as its density, cross-sectional area, and its electrical characteristics, such as, electric flux permittivity and coupling factor. These devices can also be set up in a number of modes which are determined by the way the piezoelectric device is arranged, and the shape of the transducer. For this application we are using the longitudinal or thickness mode for our operation. The transducer also vibrates in the lateral mode, and one of the goals of my project is to decrease the amount of energy lost to the lateral mode. To model the behavior of the transducers I will be using Pspice, electric circuit modeling tool, to determine the transducer's electrical characteristics at the frequency of interest. This will also help me determine the characteristics of an impedance matching network to operate the transducer at its optimum efficiency. For this I will use ABMs (analog behavioral modeling) to model dependent current and voltage sources that represent the transducer. I have also been working on the Labview control software for the phased array used to control the bubbles, and will begin testing on that before the end of my internship.

Goodenow, Debra↗

Assessment of Upper Body Posture and Shape with Garment-Embedded Flexible Strain Sensors

Spacesuits are critical to performing spacewalks or EVA, however can increase injury risks due to - Spacesuit Fit Concerns: Astronauts come from a diverse population; Improper suit fit will result in persistent contact and mechanical pressure on the body. - Altered Biomechanics: Mechanical constraints and pressurization can make it difficult due to - Reduced range of motion, Reduced strength capability. To improve suit design and mitigate injuries, kinematic and geometric measurements are required during EVA evaluations - Human motions inside a spacesuit may not coincide with the suit motions: Spacesuit configurations do not exactly match with human anatomical joints; Gaps/paddings inside the suit induce lags between human motion and suit motion - Conventional motion capture or 3-D scanning techniques are difficult to use to measure internal motion: Optical occlusions; Volume restrictions; Ferrous magnetic interference.

Vu, Linh↗

Metal-embedded fiber optic sensor packaging and signal demodulation scheme towards high-frequency dynamic measurements in harsh environments

Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.

47 OTHER INSTRUMENTATION↗

Drag measurements on a laminar flow body of revolution in Langley's 13 inch magnetic suspension and balance system

Low-speed wind tunnel drag force measurements were taken on a laminar flow body of revolution free of support interference. This body was tested at zero incidence in the NASA Langley 13 inch Magnetic Suspension and Balance System (MSBS). The primary objective of these tests was to substantiate the drag force measuring capabilities of the 13 inch MSBS. A secondary objective was to obtain support interference free drag measurements on an axisymmetric body of interest. Both objectives were met. The drag force calibrations and wind-on repeatability data provide a means of assessing the drag force measuring capabilities of the 13 inch MSBS. The measured drag coefficients for this body are of interest to researchers actively involved in designing minimum drag fuselage shapes. Additional investigations included: the effects of fixing transition; the effects of fins installed in the tail; surface flow visualizations using both liquid crystals and oil flow; and base pressure measurements using a one-channel telemetry system. Two drag prediction codes were used to assess their usefulness in estimating overall body drag. These theoretical results did not compare well with the measured values because of the following: incorrect or non-existent modeling of a laminar separation bubble on the body and incorrect of non-existent estimates of base pressure drag.

Dress, David A.↗

Catecholaminergic effects of prolonged head-down bed rest

Prolonged head-down bed rest (HDBR) provides a model for examining responses to chronic weightlessness in humans. Eight healthy volunteers underwent HDBR for 2 wk. Antecubital venous blood was sampled for plasma levels of catechols [norepinephrine (NE), epinephrine, dopamine, dihydroxyphenylalanine, dihydroxyphenylglycol, and dihydroxyphenylacetic acid] after supine rest on a control (C) day and after 4 h and 7 and 14 days of HDBR. Urine was collected after 2 h of supine rest during day C, 2 h before HDBR, and during the intervals 1-4, 4-24, 144-168 (day 7), and 312-336 h (day 14) of HDBR. All subjects had decreased plasma and blood volumes (mean 16%), atriopeptin levels (31%), and peripheral venous pressure (26%) after HDBR. NE excretion on day 14 of HDBR was decreased by 35% from that on day C, without further trends as HDBR continued, whereas plasma levels were only variably and nonsignificantly decreased. Excretion rates of dihydroxyphenylglycol and dihydroxyphenylalanine decreased slightly during HDBR; excretion rates of epinephrine, dopamine, and dihydroxyphenylacetic acid and plasma levels of catechols were unchanged. The results suggest that HDBR produces sustained inhibition of sympathoneural release, turnover, and synthesis of NE without affecting adrenomedullary secretion or renal dopamine production. Concurrent hypovolemia probably interferes with detection of sympathoinhibition by plasma levels of NE and other catechols in this setting. Sympathoinhibition, despite decreased blood volume, may help to explain orthostatic intolerance in astronauts returning from spaceflights.

Non-NASA Center↗

Flow Over Swept Flaps and Flap Tips

Preliminary measurements have been made of the flow over the tip of an unswept wing flap. To achieve an acceptable Reynolds number based on flap chord, the flap chord was chosen equal to the chord of the main airfoil (c = 19 in. approx. 0.48 m). The model was mounted in a 30 in. x 30 in. wind tunnel running at up to 100 ft/sec. (30 m/s): severe wind-tunnel interference was accepted, and any computations would be done using the tunnel walls as the boundaries of the computational domain. Maximum Reynolds number based on flap chord and tunnel speed was about 1.O x lO(exp 6). The grant ended before a full set of measurements could be made, but the work done so far yields a useful picture of the flow. The vortex originates at about mid-chord on the flap and rises rapidly above the chord line. It has a concentrated core, with total pressure lower than the ambient static pressure, and there is no evidence of large-scale wandering. A simple method of model construction, giving light weight and excellent surface finish, was developed.

Bradshaw, Peter↗

Atmospheric pressure flow reactor: Gas phase chemical kinetics under tropospheric conditions without wall effects

A flow reactor for simulating the interaction in the troposphere is set forth. A first reactant mixed with a carrier gas is delivered from a pump and flows through a duct having louvers therein. The louvers straighten out the flow, reduce turbulence and provide laminar flow discharge from the duct. A second reactant delivered from a source through a pump is input into the flowing stream, the second reactant being diffused through a plurality of small diffusion tubes to avoid disturbing the laminar flow. The commingled first and second reactants in the carrier gas are then directed along an elongated duct where the walls are spaced away from the flow of reactants to avoid wall interference, disturbance or turbulence arising from the walls. A probe connected with a measuring device can be inserted through various sampling ports in the second duct to complete measurements of the first and second reactants and the product of their reaction at selected XYZ locations relative to the flowing system.

Koontz, Steven L.↗

Orbital flight test shuttle external tank aerothermal flight evaluation, volume 1

This 3-volume report discusses the evaluation of aerothermal flight measurements made on the orbital flight test Space Shuttle External Tanks (ETs). Six ETs were instrumented to measure various quantities during flight; including heat transfer, pressure, and structural temperature. The flight data was reduced and analyzed against math models established from an extensive wind tunnel data base and empirical heat-transfer relationships. This analysis has supported the validity of the current aeroheating methodology and existing data base; and, has also identified some problem areas which require methodology modifications. This is Volume 1, an Executive Summary. Volume 2 contains Appendices A (Aerothermal Comparisons) and B (Flight Derived h sub 1/h sub u vs. M sub inf. Plots), and Volume 3 contains Appendix C (Comparison of Interference Factors among OFT Flight, Prediction and 1H-97A Data), Appendix D (Freestream Stanton Number and Reynolds Number Correlation for Flight and Tunnel Data), and Appendix E (Flight-Derived h sub i/h sub u Tables).

Praharaj, Sarat C.↗