Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Omics-Lethal Human Viruses, Influenza A Experiment ICL104

The purpose of this experiment was to evaluate the host response to Influenza A pandemic wild-type H1N1 (A/California/04/2009), natural isolate virus. Sample data was obtained from human lung adenocarcinoma cells (Calu-3) with wild-type H1N1 virus (A/California/04/2009) and processed for mRNA, miRNA, proteomics, metabolomics, and lipidomics expression analysis. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Leveraging unique high-resolution Omics capabilities for proteomics, metabolomics, lipidomics, and transcriptomics dataset download each have a direct relationship to a primary sample submission corresponding to a specific Influenza A virus infection.

59 BASIC BIOLOGICAL SCIENCES↗

Material Interactions in Severe Accidents – Benchmarking the MELCOR V2.2 Eutectics Model for a BWR-3 Mark-I Station Blackout: Part II – Uncertainty Analysis

Single case comparisons between severe accident simulations can provide detailed insights into severe accident model behavior, however, they cannot offer insights into model uncertainty, sensitivity to uncertain parameters, or underlying model biases.Here in this analysis, the single case benchmark comparison of the MELCOR material interaction models for a station blackout (SBO) scenario of a boiling water reactor (BWR) using representative Fukushima Daiichi Unit 1 boundary conditions is expanded to include an uncertainty analysis. As part of this uncertainty analysis, 1200 simulations are performed for each material interaction model (2400 total), with random sampling of 14 uncertain MELCOR input parameters. Input parameters are selected for their impact on models representing core degradation processes. These include candling, fuel rod failure, debris quenching and dryout. The analysis performed here is not a traditional “best-estimate” uncertainty analysis that uses best-estimate parameters or identifies best-estimate figure of merit distributions. Instead, it is an exploratory uncertainty analysis that identifies and interrogates underlying model form biases of the two material interaction models (eutectics and interactive materials models). Uniform distributions are applied to all uncertain parameters to ensure coverage of the model parameter uncertainty space. Key findings from this study include underlying model form biases exhibited by material interaction models, and notable differences in accident progression outcomes between the material interaction models. This uncertainty study extends and confirms the conclusions from the first part of this study, which compared the impact of material interaction modeling on simulation of a short-term station blackout scenario with representative Fukushima Daiichi Unit I boundary conditions. In particular, this study confirms that the eutectics model generally exhibits accelerated degradation and failure of fuel components, the core plate, and the lower head. The eutectics model also has a tendency to exhibit a greater degree of core degradation, greater debris mass formation, and larger debris mass ejection. Finally, the eutectics model exhibits higher maximum temperatures for fuel, cladding, particulate debris, oxidic molten pool, and metallic molten pool components than the interactive materials model; interactive materials model simulations exhibit a soft “limitation” on maximum temperatures that is related to the temperature at which material relocation occurs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NASA EVM Overview and Case Study

The presentation gives an overview of the National Aeronautics and Space Administration (NASA) Earned Value Management (EVM) structure. We briefly talk about the current EVM high-level policies within NASA and the EVM governing structure. It touches on the roles and responsibilities of EVM Focal Points within the Agency. We will also discuss the approach that MSFC followed in implementing EVM and better data analysis within the Habitat Holding Racks (HHR) Project. We will address the approach used at the Marshall Space Flight Center (MSFC) to effectively equip and support MSFC projects in applying a sound EVM and data analysis process. In addition, we will show metrics associated with the HHR project before and after the implementation of EVM on the project. We will discuss the monthly report, using sample data, that the project manager used each month to assess the performance of the project. The data received from EVM helped create a solid method for assessing the project s performance. The use of EVM data analysis can be an effective and efficient tool in today s environment with increasing workloads and downsizing workforces. EVM provides project managers with information that can be used in the decision making process.

Kerby, Jerald G.↗

Omics-Lethal Human Viruses, MERS-CoV Experiment MM001

The purpose of this experiment was to evaluate the host response to wild-type Middle Eastern Respiratory Syndrome coronavirus (MERS-CoV) virus infection. Sample data was obtained from primary mouse lung for mRNA, proteomics, lipidomics, and metabolomics expression analysis. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Leveraging unique high-resolution Omics capabilities for proteomics, metabolomics, lipidomics, and transcriptomics dataset downloads each have a direct relationship to a primary sample submission corresponding to a specific MERS-CoV virus infection.

59 BASIC BIOLOGICAL SCIENCES↗

Functionalized mesoporous silica materials for molsidomine adsorption: Thermodynamic study

A series of unmodified and organically modified mesoporous silica materials was prepared. The unmodified mesoporous silica was synthesized via sol–gel synthesis in the presence of D-glucose as pore-forming agent. The functionalized by phenyl, aminopropyl and mercaptopropyl groups silica materials were prepared via grafting. The fabricated adsorbent materials were characterized by Fourier transform infrared spectroscopy (FTIR) analysis, N{sub 2} adsorption/desorption and elemental analysis methods. Then their adsorption properties for mesoionic dug molsidomine were investigated at 290–313 K and physiological pH value. Thermodynamic parameters of molsidomine adsorption on the synthesized materials have been calculated. The obtained results showed that the adsorption process of molsidomine on the phenyl modified silica is the most quantitatively and energetically favorable. The unmodified and mercaptopropyl modified silica materials exhibit significantly higher adsorption capacities and energies for molsidomine than the aminopropyl modified sample. The effects are discussed from the viewpoint of nature of specific interactions responsible for the adsorption. - Graphical abstract: Comparative analysis of the thermodynamic characteristics of molsidomine adsorption showed that the adsorption process on mesoporous silica materials is controlled by chemical nature of surface functional groups. Molsidomine adsorption on the phenyl modified silica is the most quantitatively and energetically favorable. Taking into account ambiguous nature of mesoionic compounds, it was found that molsidomine is rather aromatic than dipolar. Display Omitted - Highlights: • Unmodified and organically modified mesoporous silica materials were prepared. • Molsidomine adsorption on the silica materials was studied. • Phenyl modified silica shows the highest adsorption capacity and favorable energy. • Molsidomine exhibits the lowest affinity to aminopropyl modified silica.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification Of the Defense Waste Processing Facility's (DWPF) Process Digestion Methods for the Sludge Batch 8 Qualification Sample

This report contains the results and comparison of data generated from inductively coupled plasma – atomic emission spectroscopy (ICP-AES) analysis of Aqua Regia (AR), Sodium Peroxide/Sodium Hydroxide Fusion Dissolution (PF) and Cold Chem (CC) method digestions and Cold Vapor Atomic Absorption analysis of Hg digestions from the DWPF Hg digestion method of Sludge Batch 8 (SB8) Sludge Receipt and Adjustment Tank (SRAT) Receipt and SB8 SRAT Product samples. The SB8 SRAT Receipt and SB8 SRAT Product samples were prepared in the SRNL Shielded Cells, and the SRAT Receipt material is representative of the sludge that constitutes the SB8 Batch or qualification composition. This is the sludge in Tank 51 that is to be transferred into Tank 40, which will contain the heel of Sludge Batch 7b (SB7b), to form the SB8 Blend composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated processing of environmental transmission electron microscopy images for quantification of thin film dewetting and carbon nanotube nucleation dynamics

We report scalable production of carbon nanotubes (CNTs) requires catalysts and reaction conditions that provide high nucleation efficiency. In situ characterization methods such as environmental transmission electron microscopy (ETEM) can reveal fundamental mechanisms of synthesis, but to date have primarily provided qualitative observations on small sample sizes. Here, quantitative analysis is performed using high-resolution, high-rate video capture of ETEM experimentation coupled with automated image processing, involving computer vision algorithms and convolutional neural networks. By this approach, we detect distinct nanoparticle formation from an alumina-supported iron thin film and subsequent CNT nucleation from the nanoparticles. The statistical summary of particles in each video shows that, compared to a H 2 -only atmosphere, pretreatment of the catalyst with carbon added to the H 2 atmosphere results in a smaller average particle diameter, a 2-fold increase in particle density (to 5300 particles/μm 2 ), a 3-fold increase in CNT nucleation efficiency (to 92%), and more than a 5-fold increase in CNT density (to 4800/μm 2 ). Addition of carbon during exposure to H 2 is also more effective than NH 3 at dewetting the catalyst film and increasing the CNT nucleation efficiency, in spite of NH 3 being a stronger reducing agent for iron. Insights from this study are applicable to improving CNT yield and productivity in both batch-style and continuous processes.

25 ENERGY STORAGE↗

Analysis of Waste Material Feedstocks Using Laser-Induced Breakdown Spectroscopy and Machine Learning

Predicting properties such as heating value, ash fusion temperature, and mineral ash composition from Laser-Induced Breakdown Spectroscopy (LIBS) data can make gasifiers more flexible to different feedstocks. Understanding these feedstock properties in-situ improves feedstock conversion modelling methods that allow for consistent operation, higher carbon conversion, and reduced fouling and erosion rates. The purpose of this study is to demonstrate methods for model creation that take LIBS data as predictor features and estimate higher order material properties as a function of feedstock material properties. Six samples were chosen to represent a mixture of abundant and carbon rich waste materials. LIBS measurements were performed on these samples for elemental wavelengths and intensity values. Laboratory analytical results were obtained for each sample’s heating value, proximate and ultimate analysis, mineral ash composition, ash fusion temperatures, and viscosity temperatures. Thermal conductivity was measured using a HotDisk TPS 2500S. LIBS measurements were processed and used as predictor features for machine learning (ML) models to predict the sample’s material properties. Predictor feature selection algorithms, particularly minimum redundancy maximum relevance (mRMR), reduced the dimensionality of ML models. Many modelling methods such as Gaussian process regression (GPR), regression tree, neural networks (NN), and support vector machines (SVM) were demonstrated to be effective at predicting higher order properties; however, mRMR with GPR stood out as a clear winning combination.

01 COAL, LIGNITE, AND PEAT↗

Omics-Lethal Human Viruses, Interferon-Stimulated Response Experiment IFNaCL001

The purpose of this experiment was to evaluate the host interferon-stimulated cellular response to interferon alpha (IFNα) treatment. Sample data was obtained from human lung adenocarcinoma cells (Calu-3) treated with or without IFNα for mRNA and miRNA transcriptome expression analysis. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Transcriptomics dataset download have a direct relationship to a primary sample submission corresponding to a specific interferon response to viral infection.

59 BASIC BIOLOGICAL SCIENCES↗

2023 Cleanroom Monitoring for OSIRIS-REx

OSIRIS-REx is an asteroid sample return mission that delivered asteroid regolith from Bennu to Earth on 9/24/2023 [1]. Cleanroom monitoring of OSIRIS-REx Curation facilities has been ongoing since 2021 when construction of the OSIRIS-REx lab at Johnson Space Center (JSC) was completed [2]. The monitoring continues inside of the OSIRIS-REx lab in Houston. Monitoring was also conducted on a temporary cleanroom constructed inside a hangar at the Utah Test and Training Range (UTTR) to initially receive the Sample Return Capsule (SRC) upon its landing there. The following reports on cleanroom monitoring that has taken place in the months leading up to as well as after OSIRIS-REx return. Monitoring techniques used include particle counts, deployment of Si wafer witness plates (Balazs, Inc.) and Al foil witness plates, gas sampling (Balazs, Inc.) and microbiological monitoring. We collected particle counts at both the lab at JSC as well as the temporary cleanroom at UTTR. Particle counts were taken monthly from six locations in the lab at JSC. Particle counts were taken from seven locations at UTTR in July, August, and September. The UTTR cleanroom particle counts were taken daily in the five days leading to OSIRIS-REx return as well as consistently the day of return (every 2 minutes and 15 seconds 7:21 am- 6:27 pm) from one location inside the cleanroom. The particle counts at UTTR consistently stayed well within the ranges of its required ISO 7 equivalent classification (352,000 maximum particles/ m3 ≥ 0.5 μm). Most analysis showed that the particle counts were far below ISO 7 requirements (highest measured count was 61,484 particles/ m3 ≥ 0.5 um). but the elevated instances correlated to exterior hangar doors being open. Particle counts were reduced when keeping exterior hangar doors closed. The particle counts at JSC have stayed consistently within their ISO 5 equivalent classification (3,520 maximum particles/ m3 ≥ 0.5 um). In most instances, the counts are much better except in one instance where the count measured 13,381 particles/ m3 ≥ 0.5 um. The high spike in particle counts in the JSC lab correlated with the air handlers being shut down temporarily the previous day. The particle counts taken in the same location quickly reduced and measured 0 when taken a month later with the air handlers on. We deployed 8-inch semiconductor polished Si wafer witness plates for 24-hour periods inside of the OSIRIS-REx Curation lab at JSC (in July, August, September, and November 2023) and the cleanroom at UTTR (July and September 2023) to test for possible organic and inorganic contaminants. We also deployed these wafers inside of the OSIRIS-REx Touch-and-Go sample Acquisition Mechanism (TAGSAM) glovebox (where Bennu sample processing occurs) and desiccator (Bennu sample storage) at JSC in August 2023. These samples were all sent to Balazs for analysis via Thermal Desorption Gas Chromatography Mass Spectroscopy (TD-GC-MS) to quantify organic compounds and vapor phase decomposition inductively coupled plasma mass spectrometry (VPD-ICP-MS) to quantify inorganic contaminants. We collected air samples using an adsorbent tube connected to a pump for six hours (100 mL/minute) inside of both the JSC lab and the UTTR cleanroom. These samples were taken at JSC in July, August, September, November, and December and at UTTR in July and September. Additionally, a sample was taken just outside of the TAGSAM glovebox airlock door in July. These samples were sent to Balazs for analysis of volatile organics in air. Overall, the OSIRIS-REx lab at JSC and cleanroom at UTTR yielded very low organic and inorganic contaminants (similar results to Genesis lab at JSC which is ISO 4 equivalent) except for boron, which is attributed to the borosilicate glass in the fan filter units. We collected monthly surface and air samples inside the JSC lab to monitor potential microbial contamination. We report the recovery rate for each sampling event, which is defined as the number of samples exhibiting bacterial or fungal growth divided by the total number of samples collected. Since the lab was commissioned in 2021 the median recovery rate is 29%. This recovery rate is consistent with other ISO 5 equivalent labs used to curate astromaterials collections. Increases in recovery rate correspond to construction and/or extra activity in the lab. However, increases in recovery rate do not reliably correlate to increases in particle counts, which highlights the need for a dedicated microbial monitoring program for biologically sensitive collections. We sampled the temporary clean room at UTTR in July, August, and September of 2023 to monitor potential microbial contamination. The recovery rate decreased from 80% in August to 29% in September. However, in all instances, the diversity of bacteria and fungi was higher in the UTTR cleanroom than in the JSC lab. We routinely collected more than twenty different organisms from the UTTR cleanroom. In the JSC lab the median diversity is 2 organisms. Based on these results we hypothesize that microbes from UTTR could be transported back to JSC with the Bennu samples. To mitigate this risk, in September of 2023, we implemented additional cleaning procedures in the JSC lab to reduce the bioburden on surfaces that could come into direct contact with hardware used to process Bennu samples. Since adopting these additional cleaning measures, the median recovery rate has decreased to 14%. We did not observe an increase in fungal or bacterial diversity in the lab in the October sampling. We will continue to monitor this trend closely for the next several months. Supported by NASA under Award NNH09ZDA007O and Contract NNM10AA11C.

Rachel Comstock Funk↗

Aerosol Synthesis of Highly Dispersed Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+} Phosphor with Intense Photoluminescence

A simple method of pyrolysis of an aerosol solution of yttrium, aluminum, and cerium nitrates with the addition of urea or citric acid, followed by brief annealing, is developed to obtain a highly dispersed aluminum–yttrium garnet powder that demonstrates intense photoluminescence in the visible light region. Characterization of the synthesized samples (photoluminescence spectra, X-ray diffraction analysis, Raman spectra) showed that intense photoluminescence is achieved only in a narrow window of process conditions, namely, the concentration of nitrate solution and the concentration of citric acid or urea. The photoluminescence intensity increases upon annealing synchronously with an increase in the crystallite size, which, along with the optimal cerium concentration (~0.5 at %), is a determining factor for obtaining high-quality samples. The synthesized powders had intense photoluminescence and high optical perfection, as evidenced by the observation of whispering gallery modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Metabolite, Protein, and Lipid Extraction (MPLEx): a method that simultaneously inactivates Middle East respiratory syndrome coronavirus and allows analysis of multiple host cell components following infection

Mass spectrometry (MS)-based, integrated proteomics, metabolomics, and lipidomics (collectively, multi-omics) studies provide a very detailed snap shot of virus-induced changes to the host following infection and can lead to the identification of novel prophylactic and therapeutic targets for preventing or lessening disease severity. Multi-omics studies with Middle East respiratory syndrome coronavirus (MERS-CoV) are challenging as the requirements of Biosafety Level 3 containment limit the numbers of samples that can be safely managed. To address these issues, the multi-omics sample preparation technique MPLEx (metabolite, protein, and lipid extraction) was developed to partition a single sample into three distinct parts (metabolites, proteins and lipids) for multi-omics analysis, while simultaneously inactivating MERS-CoV by solubilizing and disrupting the viral envelope and denaturing viral proteins. Here we describe the MPLEx protocol, highlight the step of inactivation, and describe the details of downstream processing, instrumental analysis of studies with Middle East respiratory syndrome coronavirus (MERS-CoV) are challenging as the requirements of Biosafety Level 3 containment limit the numbers of samples that can be safely managed. To address these issues, the multi-omics sample preparation technique MPLEx (metabolite, protein, and lipid extraction) was developed to partition a single sample into three distinct parts (metabolites, proteins and lipids) for multi-omics analysis, while simultaneously inactivating MERS-CoV by solubilizing and disrupting the viral envelope and denaturing viral proteins. Here we describe the MPLEx protocol, highlight the step of inactivation, and describe the details of downstream processing, instrumental analysis of the three separate analytes and their subsequent informatics pipelines.

Nicora, Carrie D.↗

Omics-Lethal Human Viruses, Interferon-Stimulated Response Experiment IFNMVE001

The purpose of this experiment was to evaluate the human host interferon-stimulated cellular response to interferon alpha/beta (IFNα/β) or gamma (INFγ) treatment. Sample data was obtained from primary lung microvascular endothelial cells (MVE) treated with or without human IFNαβ or INFγ for mRNA transcriptome expression analysis. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Transcriptomics dataset download have a direct relationship to a primary sample submission corresponding to a specific interferon response to viral infection.

59 BASIC BIOLOGICAL SCIENCES↗

Fluid Phase Separation (FPS) experiment for flight on the shuttle in a Get Away Special (GAS) canister: Design and fabrication

The separation of fluid phases in microgravity environments is of importance to environmental control and life support systems (ECLSS) and materials processing in space. A successful fluid phase separation experiment will demonstrate a proof of concept for the separation technique and add to the knowledge base of material behavior. The phase separation experiment will contain a premixed fluid that will be exposed to a microgravity environment. After the phase separation of the compound has occurred, small samples of each of the species will be taken for analysis on Earth. By correlating the time of separation and the temperature history of the fluid, it will be possible to characterize the process. The phase separation experiment is totally self-contained, with three levels of containment on all fluids, and provides all necessary electrical power and control. The controller regulates the temperature of the fluid and controls data logging and sampling. An astronaut-activated switch will initiate the experiment and an unmaskable interrupt is provided for shutdown. The experiment has been integrated into space available on a manifested Get Away Special (GAS) experiment, CONCAP 2, part of the Consortium for Materials Complex Autonomous Payload (CAP) Program, scheduled for STS 42 in April 1991. Presented here are the design and the production of a fluid phase separation experiment for rapid implementation at low cost.

Source record↗

Investigation of Process Emissions during Thermal Cutting of Clad Metals from the Nuclear Sector - 20183

Typically, reactor pressure vessels as well as steam generators comprising low alloyed steel with a cladding of stainless steel. Recently the permissible values for Cr (VI) in the air of the working areas have been reduced in Germany from 100 μg/m{sup 3} to 1 μg/m{sup 3} air. This results in the danger that even with low-alloy steel with claddings these limit values would be exceeded when using flame cutting technologies. In order to ensure compliance with the permissible limit values, exhaust gas systems with gas cleaning measures are provided. The process emission test shall replace the assumptions required for the design of these systems with measured values. NUKEM Technologies Engineering Services GmbH (NUKEM) has chosen autogenous flame cutting as an example of a thermal cutting system for process emission testing, as there are no proven values in the literature for the Cr (VI) and NiOx emissions produced. The autogenous flame cutting can be used for a variety of cutting tasks within decommissioning projects. In order to simulate the material to be cut, mock ups were generated and cut from information about the material specification for the reactor pressure vessel from existing nuclear power plants including possible claddings. The cutting length needed for analysis in the test will be maximum 100 mm. The airborne emissions from the thermal cutting process will be captured and analyzed as follows: - Dust emission: The generated particles will be collected by a hood equipped with strong suction device and suitable filter elements. The resulting filter is gravimetrically measured before and after the tests. - Particle Size Distribution: The airborne particle size distribution measurement will result in figures for the size and number of particles arising from the thermal cutting process. - Gas Analysis: The gas analysis enables the determination of e.g. CO{sub 2}, CO, O{sub 3}, NO, NO{sub 2}. - Cr (VI) and NiOx Analysis: For the Cr (VI) and NiOx analysis, samples of the filter residue will be taken. As a result Cr (VI) in relation to total Cr as well as the Ni content will be determined by ICP-optically emission spectroscopy and put in relation to the total dust amount. The process emissions test itself as well as the necessary gas analyses and spectroscopic analyses were carried out at the Institute of Materials Science (IW) of Leibniz Universitaet Hannover (LUH). The results of the process emission tests are used to confirm the design of the gas cleaning systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compilation of PRF Canyon Floor Pan Sample Analysis Results

On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showed some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of common anions, gamma spectrometry, metals, corrosivity, organics and alpha spectrometry (note: alpha spectrometry was cancelled during the performance of this work with concurrence from CHPRC). Results may help elucidate the components that led to the unexpected reaction in the canyon as well as inform the radiological and hazardous characteristics. The specific anions, gamma emitters, organics and metals requested by CHPRC are provided in the analytical reports sections. The individual analyses were conducted under the Plutonium Finishing Plant (PFP) Floor Pan Evaluation Project Quality Assurance Project Plan (PFP Floor Pan Evaluation QAPP, Revision 0.) developed by PNNL specifically for this project. The final reports for each analysis set are included in this compilation of the results. Each package was reviewed under the PFP Floor Pan Evaluation Project Quality Assurance Project Plan so no additional reviews were conducted in this compilation task. The Gas Generation Rates in Appendix G were conducted under the PNNL “How Do I…” quality assurance program and were NOT conducted under the Plutonium Finishing Plant (PFP) Floor Pan Evaluation Project Quality Assurance Project Plan (PFP Floor Pan Evaluation QAPP, Revision 0.).

36 MATERIALS SCIENCE↗

Probabilistic Predictions for Fastener Failure in the Sandia Mechanics Challenge Using the Discrete-Direct Uncertainty Quantification Approach

This paper documents the blind and post-blind analysis predictions for the 2023 Sandia Mechanics Challenge (SMC), which involved predicting the behavior of a threaded fastener joint structure subjected to shock loading. Utilizing repeat sets of fastener calibration data from various experimental configurations including tension, double shear, and joint tension, we developed a library of calibrated models which were propagated through the application model using the Discrete-Direct (DD) uncertainty quantification (UQ) approach. Although the initial blind predictions did not incorporate spare-sample processing to quantify fastener failure probabilities, the analyses yielded reasonable conclusions aligned with experimental results. In the post-blind analysis phase, we focused on enhancing the fidelity of the aluminum constitutive model and innovating the DD approach to obtain probabilistic predictions for fastener failure, particularly when quantities of interest (QoIs) approach their bounds. The improved aluminum model captures the behavior of the cantilever under shock loading more accurately, predicting both partial and complete cracks, although it tends to underpredict failure propagation. The enhanced DD approach facilitates probabilistic predictions that reflect the interdependent failure mechanisms of the fasteners and the cantilever, revealing that while certain fasteners are more likely to fail, the failure does not necessarily follow a progressive pattern. Overall, the post-blind analyses significantly improved the predictive capabilities of the model, providing valuable insights into the SMC application and establishing a robust foundation for informed engineering decisions. The methodology demonstrates a cost-effective and extensible approach suitable for a wide range of applications, highlighting the importance of uncertainty quantification to provide context for engineering decision making.

42 ENGINEERING↗