Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Spectro-Microscopy Studies of Atmospheric Particles

Our project investigated composition and physical properties of individual atmospheric particles collected in field campaigns organized by the DOE Atmospheric Systems Research and Atmospheric Radiation Measurement (ASR/ARM) programs, such as the Green Ocean Amazon (GoAmazon, 2014/5), the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems (HI-SCALE, 2016/7), the Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA, 2017/8), the Aerosol–Ice Formation Closure Pilot Study (AEROICESTUDY, 2019) and in additional small-scale supporting field experiments focused on the investigation of the light-absorbing (aka brown carbon) atmospheric particles. In these studies, we investigated the contribution of natural and anthropogenic sources to populations of atmospheric particles during representative atmospheric conditions; characterized particle composition and evaluated their hygroscopic properties and propensity to act as cloud condensation nuclei (CCN) and ice nuclei (IN); correlated typical particle-type and mixing state characteristics with real-time measurements in the areas of studies. We used multi-modal spectro-microscopy techniques to examine elemental and molecular composition, mixing state, size, and higher order morphology for individual particles. Specifically, we used computer-controlled scanning electron microscopy and X-ray microanalysis for quantitative analysis of particle elemental composition, and we used transmission electron microscopy to provide additional information on the distribution of different components within individual particles (particle heterogeneity). We used synchrotron-based scanning transmission X-ray microscopy for quantitative description of the mixing state and molecular bonding of carbon in particles. The particle composition, mixing state, and morphology from analyzed periods was then combined with the real-time ARM measurements of aerosol size distribution, CCN concentration, hygroscopicity, and aerosol bulk composition. Combined together, results of our studies allowed us to assess the major particle sources (biogenic vs. anthropogenic, primary vs secondary) and gain insight into the atmospheric processing of aerosol particles resulting from condensation, coagulation, oxidative aging, and cloud processing. In collaboration with other scientists involved in field campaigns, we carried out statistical analysis of particle properties and their source-specific contributions to regional aerosol loading under representative air mass, meteorological, and cloud conditions.

scanning transmission X-ray microscopy↗

Remote Raman - laser induced breakdown spectroscopy (LIBS) geochemical investigation under Venus atmospheric conditions

The extreme Venus surface temperatures ({approx}740 K) and atmospheric pressures ({approx}93 atm) create a challenging environment for surface missions. Scientific investigations capable of Venus geochemical observations must be completed within hours of landing before the lander will be overcome by the harsh atmosphere. A combined remote Raman - LIBS (Laser Induced Breakdown Spectroscopy) instrument is capable of accomplishing the geochemical science goals without the risks associated with collecting samples and bringing them into the lander. Wiens et al. and Sharma et al. demonstrated that both analytical techniques can be integrated into a single instrument capable of planetary missions. The focus of this paper is to explore the capability to probe geologic samples with Raman - LIBS and demonstrate quantitative analysis under Venus surface conditions. Raman and LIBS are highly complementary analytical techniques capable of detecting both the mineralogical and geochemical composition of Venus surface materials. These techniques have the potential to profoundly increase our knowledge of the Venus surface composition, which is currently limited to geochemical data from Soviet Venera and VEGA landers that collectively suggest a surface composition that is primarily tholeiitic basaltic with some potentially more evolved compositions and, in some locations, K-rich trachyandesite. These landers were not equipped to probe the surface mineralogy as can be accomplished with Raman spectroscopy. Based on the observed compositional differences and recognizing the imprecise nature of the existing data, 15 samples were chosen to constitute a Venus-analog suite for this study, including five basalts, two each of andesites, dacites, and sulfates, and single samples of a foidite, trachyandesite, rhyolite, and basaltic trachyandesite under Venus conditions. LIBS data reduction involved generating a partial least squares (PLS) model with a subset of the rock powder standards to quantitatively determine the major elemental abundance of the remaining samples. PLS analysis suggests that the major element compositions can be determined with root mean square errors ca. 5% (absolute) for SiO{sub 2}, Al{sub 2}O{sub 3}, Fe{sub 2}O{sub 3}(total), MgO, and CaO, and ca. 2% or less for TiO{sub 2}, Cr{sub 2}O{sub 3}, MnO, K{sub 2}O, and Na{sub 2}O. Finally, the Raman experiments have been conducted under supercritical CO{sub 2} involving single-mineral and mixed-mineral samples containing talc, olivine, pyroxenes, feldspars, anhydrite, barite, and siderite. The Raman data have shown that the individual minerals can easily be identified individually or in mixtures.

36 MATERIALS SCIENCE↗

Epidermal growth factor receptor cascade prioritizes the maximization of signal transduction

Many studies have been performed to quantify cell signaling. Cell signaling molecules are phosphorylated in response to extracellular stimuli, with the phosphorylation sequence forming a signal cascade. The information gain during a signal event is given by the logarithm of the phosphorylation molecule ratio. The average information gain can be regarded as the signal transduction quantity (ST), which is identical to the Kullback–Leibler divergence (KLD), a relative entropy. We previously reported that if the total ST value in a given signal cascade is maximized, the ST rate (STR) of each signaling molecule per signal duration (min) approaches a constant value. To experimentally verify this theoretical conclusion, we measured the STR of the epidermal growth factor (EGF)-related cascade in A431 skin cancer cells following stimulation with EGF using antibody microarrays against phosphorylated signal molecules. The results were consistent with those from the theoretical analysis. Thus, signaling transduction systems may adopt a strategy that prioritizes the maximization of ST. Furthermore, signal molecules with similar STRs may form a signal cascade. In conclusion, ST and STR are promising properties for quantitative analysis of signal transduction.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular dynamics simulation of radiation damage cascades in diamond

Radiation damage cascades in diamond are studied by molecular dynamics simulations employing the Environment Dependent Interaction Potential for carbon. Primary knock-on atom (PKA) energies up to 2.5 keV are considered and a uniformly distributed set of 25 initial PKA directions provide robust statistics. The simulations reveal the atomistic origins of radiation-resistance in diamond and provide a comprehensive computational analysis of cascade evolution and dynamics. As for the case of graphite, the atomic trajectories are found to have a fractal-like character, thermal spikes are absent and only isolated point defects are generated. Quantitative analysis shows that the instantaneous maximum kinetic energy decays exponentially with time, and that the timescale of the ballistic phase has a power-law dependence on PKA energy. Defect recombination is efficient and independent of PKA energy, with only 50% of displacements resulting in defects, superior to graphite where the same quantity is nearly 75%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

edxia: Microstructure characterisation from quantified SEM-EDS hypermaps

The characterisation of cement paste microstructure is an important step towards understanding durability mechanisms in cementitious materials. Scanning electron microscopy (SEM) coupled with energy dispersive spectroscopy (EDS) is a widely used technique to analyse the microstructure at the micron-scale. However, it is challenging, notably because the characteristic size of many phases is found on a scale smaller than the EDS interaction volume. This work presents a new image analysis framework to identify phases and quantify the microstructure of cementitious materials from SEM-EDS hypermaps. By leveraging domain knowledge, representative points are attributed to phases and mixtures of phases based on ratio plots. Then, quantitative analysis of the microstructure can be carried out (chemical composition, particle size distributions, volume fractions, …). We demonstrate the abilities of the framework, and we present possible applications and extensions of the method. The framework is available as both a graphical interface and a Python code.

36 MATERIALS SCIENCE↗

Using Clinical Data, Hypothesis Generation Tools and PubMed Trends to Discover the Association between Diabetic Retinopathy and Antihypertensive Drugs

Diabetic retinopathy (DR) is a leading cause of blindness and common complication of diabetes. Many diabetic patients take antihypertensive drugs to prevent cardiovascular problems, but these drugs may have unintended consequences on eyesight. Six common classes of antihypertensive drug are angiotensin converting enzyme (ACE) inhibitors, alpha blockers, angiotensin receptor blockers (ARBs), -blockers, calcium channel blockers, and diuretics. Analysis of medical history data might indicate which of these drugs provide safe blood pressure control, and a literature review is often used to guide such analyses. Beyond manual reading of relevant publications, we sought to identify quantitative trends in literature from the biomedical database PubMed to compare with quantitative trends in the clinical data. By recording and analyzing PubMed search results, we found wide variation in the prevalence of each antihypertensive drug in DR literature. Drug classes developed more recently such as ACE inhibitors and ARBs were most prevalent. We also identified instances of change-over-time in publication patterns. We then compared these literature trends to a dataset of 500 diabetic patients from the UT Hamilton Eye Institute. Data for each patient included class of antihypertensive drug, presence and severity of DR. Graphical comparison revealed that older drug classes such as diuretics, calcium channel blockers, and -blockers were much more prevalent in the clinical data than in the DR and antihypertensive literature. Finally, quantitative analysis of the dataset revealed that patients taking -blockers were statistically more likely to have DR than patients taking other medications, controlling for presence of hypertension and year of diabetes onset. This finding was concerning given the prevalence of -blockers in the clinical data. We determined that clinical use of -blockers should be minimized in diabetic patients to prevent retinal damage.

Big data↗

Alternative Analysis and Prioritization of Department of Energy “TBD” Materials with No Identified Disposition Pathway

The Department of Energy (DOE) complex manages a significant inventory of excess nuclear materials for which disposition pathways have not been identified, commonly referred to as "To Be Determined" (TBD) items. The Disposition Pathways Program, initiated in FY2018, provides a standardized framework for identifying viable disposition pathways for these materials. In 2023, the program undertook a comprehensive review and systematic analysis of the remaining TBD material groups, updating the assessment from the 2020 TBD Study using the 2022 fiscal year-end Nuclear Material Inventory Assessment (NMIA) as the primary data source. This effort aimed to utilize quantitative analysis to down-select from a wide range of potential disposition options and prioritize the remaining pathways to facilitate informed, risk-based decision-making for future programmatic funding and execution. This paper details the alternative analysis methodology used for screening and prioritization, highlighting the key criteria, ranking process, and resultant recommendations. The study successfully narrowed fifty-two potential disposition options down to nineteen, providing a focused path forward for addressing a longstanding challenge within the DOE complex.

Ramsey, Catherine [Savannah River National Laborat↗

Maximizing selectivity: An analysis of isoporous membranes

Membranes are compelling candidates for many separation-based industrial processes. However, all synthetic membranes are subject to well-recognized permeability-selectivity trade-offs that hinder their use in advanced applications. Having uniform nanoscale pore size, isoporous nanofiltration and ultrafiltration membranes have attracted wide research interest. However, quantitative analysis of isoporous membrane performance is lacking - particularly at module and system-level scales. In this study, an analytical model is built to investigate how membrane pore-size distribution affects the solute separation efficiency (i.e., rejection and selectivity). The model accounts for convective hindrance as well as concentration polarization and explores effects on separation from the solute-to-pore-size ratio and percent recovery (i.e., fraction of feed flow that passes through the membrane). At the module level, our analysis suggests that a notably sharper rejection vs. solute size curve can be obtained as the pore-size distribution becomes narrower. Additionally, as the recovery increases, the rejection of a solute is maintained at a high level using isoporous membranes while the rejection drops rapidly for membranes that possess a disperse pore-size distribution. Furthermore, in the separation of mixed solutes, isoporous membranes achieve a large selectivity with a modest loss of permeability. Overall, this study elaborates the unique role that isoporous membranes play within the permeability-selectivity trade-off relations and identifies the most exciting opportunities for their future applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent JET experiments on Alfven eigenmodes with intermediate toroidal mode numbers: measurements and modelling of n=3 toroidal Alfven eigenmodes with the TAEFL code

This paper reports the results of recent experiments performed on the JET tokamak on Alfven eigenmodes (AEs) with toroidal mode number (n) in the range n = 3-15. The stability properties of these medium-n AEs are investigated experimentally using a new set of compact in-vessel antennas, providing a direct and real-time measurement of the frequency, damping rate and amplitude for each individual toroidal mode number. We report here the quantitative analysis of the measurements of the damping rate for stable n = 3 toroidal AEs as a function of the edge plasma elongation, and the theoretical analysis of these data with the TAEFL code. The TAEFL results are in excellent qualitative agreement with the measurements, reproducing well the experimental scaling of increasing damping rate versus increasing edge elongation, and in many cases are also quantitatively correct, with a difference with respect to the measurements below 30%, particularly for magnetic configurations that have a larger edge magnetic shear.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Risk analysis of an RTG on the Space Shuttle

As part of the effort to review the Ulysses Final Safety Analysis Report and to understand the risk of plutonium release from the Ulysses spacecraft General Purpose Heat Source-Radioisotope Thermal Generator (GPHS-RTG), the Interagency Nuclear Safety Review Panel (INSRP) and the author performed an integrated, quantitative analysis of the uncertainties of the calculated risk of plutonium release from Ulysses. Using state-of-the-art probabilistic risk assessment technology, the uncertainty analysis accounted for both variability and uncertainty of the key parameters of the risk analysis. The results show tht INSRP had high confidence that risk of fatal cancers from potential plutonium release associated with calculated launch and deployment accident scenarios is low.

Frank, Michael V.↗

Single Variable and Multivariate Analysis of Remote Laser-Induced Breakdown Spectra for Prediction of Rb, Sr, Cr, Ba, and V in Igneous Rocks

Laser-induced breakdown spectroscopy (LIBS) will be employed by the ChemCam instrument on the Mars Science Laboratory rover Curiosity to obtain UV, VIS, and VNIR atomic emission spectra of surface rocks and soils. LIBS quantitative analysis is complicated by chemical matrix effects related to abundances of neutral and ionized species in the resultant plasma, collisional interactions within plasma, laser-to-sample coupling efficiency, and self-absorption. Atmospheric composition and pressure also influence the intensity of LIBS plasma. These chemical matrix effects influence the ratio of intensity or area of a given emission line to the abundance of the element producing that line. To compensate for these complications, multivariate techniques, specifically partial least-squares regression (PLS), have been utilized to predict major element compositions (>1 wt.% oxide) of rocks, PLS methods regress one or multiple response variables (elemental concentrations) against multiple explanatory variables (intensity at each pixel of the spectrometers). Because PLS utilizes all available explanatory variable and eliminates multicollinearity, it generally performs better than univariate methods for prediction of major elements. However, peaks arising from emissions from trace elements may be masked by peaks of higher intensities from major elements. Thus in PLS regression, wherein a correlation coefficient is determined for each elemental concentration at each spectrometer pixel, trace elements may show high correlation with more intense lines resulting from optical emissions of other elements. This could result in error in predictions of trace element concentrations. Here, results of simple linear regression (SLR) and multivariate PLS-2 regression for determination of trace Rb, Sr, Cr, Ba, and V in igneous rock samples are compared. This study focuses on comparisons using only line intensities rather than peak areas to highlight differences between SLR and PLS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomistic Simulation of Water Percolation and Proton Hopping in Nafion Fuel Cell Membrane

We have performed a detailed analysis of water clustering and percolation in hydrated Nafion configurations generated by classical molecular dynamics simulations. Our results show that at low hydration levels H2O molecules are isolated and a continuous hydrogen-bonded network forms as the hydration level is increased. Our quantitative analysis has established a hydration level (λ) between 5 and 6 H2O/SO3- as the percolation threshold of Nafion. We have also examined the effect of such a network on proton transport by studying the structural diffusion of protons using the quantum hopping molecular dynamics method. The mean residence time of the proton on a water molecule decreases by two orders of magnitude when the λ value is increased from 5 to 15. The proton diffusion coefficient in Nafion at a λ value of 15 is about 1.1x10-5 cm2/s in agreement with experiment. The results provide quantitative atomic-level evidence of water network percolation in Nafion and its effect on proton conductivity.

30 DIRECT ENERGY CONVERSION↗

Nondirect product discrete variable representation in multidimensional quantum problems

We have developed a method for treating different quantum few-body dynamics without traditional partial-wave analysis. The key element of the method is a nondirect product discrete variable representation (npDVR) we have suggested and developed in application to the time-dependent mutidimensional Schroedinger equations. It happened that this approach was very efficient in quantitative analysis of low-dimensional ultracold few-body systems arising in confined geometry of atomic traps. As an example, we consider the numerical analysis of the four-dimensional Schroedinger equation describing the resonant molecule formation in confined two-component atomic mixture with transferring the energy release to the center-ofmass excitation of forming molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface analysis insight note: X‐ray photoelectron spectroscopy analysis of battery electrodes—Challenges with nickel–manganese–cobalt and Li examples using an Al Kα x‐ray source

X‐ray photoelectron spectroscopy (XPS) has become a highly important tool for the analysis of battery materials and components. However, both anecdotal and detailed analysis of selected parts of the literature indicate that many reports of XPS on battery electrodes have significant analysis or data flaws. In this paper, we highlight several of the common challenges that analysts face when using XPS for battery materials, pointing to recent literature that addresses many of the critical issues associated with sample preparation as well as data collection and analysis. A common error for battery materials (and other materials) involves ignoring peak overlaps and interferences. Specifically, when a “minor” peak associated with a component in relatively high concentration overlaps or contributes to the primary peak (or one recommended for quantitative analysis) from a different element in the material. Overlap issues apply to many battery electrodes composed of many elements with complex photoelectron peak structures, as well as those involving peaks with seemingly simpler spectral envelopes such as Li and F. Examples of issues associated with battery systems are highlighted by a discussion of challenges associated with XPS analysis of Li and nickel–manganese–cobalt (NMC) electrodes in battery systems. Lithium analysis has challenges associated with the preparation and an often‐unrecognized peak overlap with F. In our laboratory and in the literature, NMC electrodes are often examined and new XPS users do not always recognize interference of the Auger signal from F KLL (in or on the electrode) with Ni 2p photoelectron spectrum when generated with Al Kα X‐rays. The use of simulated spectra involving both F and NiO demonstrates the extent of F Auger contributions to the Ni 2p signal strength as a function of the F/Ni atom ratio in the material and suggests spectra information that can be used to identify how significant effects will be on the resultant spectra. Our analysis demonstrates that in many cases overlap issues are significant for real electrode materials.

25 ENERGY STORAGE↗

Quantitatively Probing the Al Distribution in Zeolites

The degree of substitution of Si4+ by Al3+ in the oxygen-terminated tetrahedra (Al T-sites) of zeolites determines the concentration of ion-exchange and Brønsted acid sites. As the location of the tetrahedra and the associated subtle variations in bond angles influence the acid strength, quantitative information about Al T-sites in the framework is critical to rationalize catalytic properties and to design new catalysts. A quantitative analysis is reported that uses a combination of extended X-ray absorption fine structure (EXAFS) analysis and 27Al MAS NMR spectroscopy supported by DFT-based molecular dynamics simulations. To discriminate individual Al atoms, sets of ab initio EXAFS spectra for various T-sites are generated from DFT-based molecular dynamics simulations allowing quantitative treatment of the EXAFS single- and multiple-photoelectron scattering processes out to 3-4 atom shells surrounding the Al absorption center. It is observed that identical zeolite types show dramatically different Al-distributions. A preference of Al for T-sites that are part of one or more 4-member rings in the framework over those T-sites that are part of only 5- and 6-member rings in the HBEA150 sample has been determined from a combination of these methods. This work was supported by the U. S. Department of Energy (DOE), Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences.

aluminum↗

A Quantitative Study of Deep Learning Training on Heterogeneous Supercomputers

Deep learning (DL) has become a key technique for solving complex problems in scientific research and discovery. DL training for science is substantially challenging because it has to deal with massive quantities of multi-dimensional data. High- performance computing (HPC) supercomputers are increasingly being employed for meeting the exponentially growing demand for DL. Multiple GPUs and high-speed interconnect network are needed for supporting DL on HPC systems. However, the excessive use of GPUs without considering effective benefits leads to inefficient resource utilization of these expensive setups. In this paper, we conduct a quantitative analysis to gauge the efficacy of DL workloads on the latest HPC system and identify viability of next-generation DL-optimized heterogeneous supercomputers for enabling researchers to develop more efficient resource management and distributed DL middleware. We evaluate well- known DL models with large-scale datasets using the popular TensorFlow framework, and provide a thorough evaluation in- cluding scalability, accuracy, variability, storage resource, GPU- GPU/GPU-CPU data transfer, and GPU utilization. Our analysis reveals that the latest heterogeneous supercomputing cluster shows varying performance trend as compared to the existing literature for single- and multi-node training. To the best of our knowledge, this is the first work to conduct such a quantitative and comprehensive study of DL training on a supercomputing system with multiple GPUs.

Han, Jingoo↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗