Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Dynamic Data-Driven Multiscale Modeling for Predicting Microstructure and Mechanical Properties of 316L Stainless Steel

We have developed a long short-term memory stacked ensemble (LSTM-SE) surrogate modeling approach that can provide rapid predictions of microstructural evolution and the resultant mechanical properties of American Iron and Steel Institute (AISI) 316L series stainless steel (316LSS) fuel cladding under conditions of varying temperature and radiation dose rate. To acquire training data, we developed and implemented a kinetic Monte Carlo (KMC) model to simulate precipitation kinetics of M 23 C 6 , γ', and G phases within SS316L cladding. Experimentally reported precipitation kinetics of SS316L in literature were linked to the kinetic parameters of the simulated precipitation in our KMC model. The model was then used to simulate microstructure evolution under synthetically generated treatments of varying temperature and radiation dose rate, for periods of up to 3000 hours. Changes in volume fraction, number density, and particle size of precipitates were recorded, and particle area fractions were correlated using statistical methods to develop the surrogate model. Simultaneously, the mechanical properties of the simulated microstructures were evaluated using microstructure-based finite element method (FEM) analysis to determine the elastic modulus, yield stress, ultimate tensile strength, and elongation to failure of the aged microstructures. Using this approach, our surrogate model can predict precipitation behavior within 0.25% volume fraction and mechanical properties within 6% relative error from the values predicted by the KMC and FEM models using 50 training simulations as input. The trained recurrent neural network-based model can return estimations of precipitation kinetics and mechanical properties ~1000 times faster than the physics-based codes. This work demonstrates, as a proof of concept, that reactor material service lifetimes under variable service conditions can be predicted for a statistics-based model from a practicably obtainable dataset.

36 MATERIALS SCIENCE↗

Reevaluating linear accelerator shielding for 320 µA of proton beam

The collider-accelerator facilities at Brookhaven National Laboratory (BNL) have been developing since the completion of the experiments they were originally built for, and their uses for research have evolved over the years with a variety of users. With these changes, we must be careful to avoid potential radiation hazards of worst-case scenarios, although these faults are unlikely. One of these changes in the Collider-Accelerator Department (C-AD) is the replacement of power supplies and upgrading the linear accelerator (Linac) radiofrequency system to allow the Brookhaven Linac Isotope Producer (BLIP) to use a 320 μA average current. This current of 320 μA is greater than any current that the Linac shielding has withstood before, and thus this project in reevaluating the Linac shielding is necessary to ensure all future Linac research is conducted safely. Particularly, this project aims to estimate the radiation doses in the Alternating Gradient Synchrotron (AGS) tunnel near the Linac tunnel and in the equipment bay room near the gate valve of the last tank (tank 9) of Linac. To do this, we used the particle transport code, Monte Carlo N-Particle 6.2 (MCNP6.2), to perform the simulation and model the facilities of Linac and AGS at BNL. This simulation allowed us to investigate the extent of radiation dose rates in various areas of the facilities by placing detectors in specific locations. We could therefore determine whether the dose rates due to these faults is acceptable for limits set by the Department of Energy (DOE) and BNL, and if the shielding is sufficient.

43 PARTICLE ACCELERATORS↗

Effect of X-ray flux on polytetrafluoroethylene in X-ray photoelectron spectroscopy

The effect of the X-ray flux in X-ray photoelectron spectroscopy (STAT) on the constitution of the polytetrafluoroethylene (PTFE) surface has been examined. The radiation dose rate for our specimen was about 10 to the 7th rad/s. The structure, magnitude and binding energy of the C(1s) and F(1s) features of the XPS spectrum and the mass spectrum of gaseous species evolved during irradiation are observed. The strong time dependence of these signals over a period of several hours indicated that the surface constitution of PTFE is greatly affected by this level of radiation dose. The results are consistent with the development of a heavily cross-linked or branched structure in the PTFE surface region and the evolution of short chain fragments into the gas phase.

Wheeler, D. R.↗

SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of Dentistry S. Wah Leung Endowment Fund.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic data-driven multiscale modeling for predicting the degradation of a 316L stainless steel nuclear cladding material

Here, we have developed a long short-term memory stacked ensemble (LSTM-SE) surrogate modeling approach that can provide rapid predictions of microstructural evolution and the resultant mechanical properties of American Iron and Steel Institute (AISI) 316L series stainless steel (316LSS) fuel cladding under conditions of varying temperature and radiation dose rate. To acquire training data, we developed and implemented a kinetic Monte Carlo (KMC) model to simulate precipitation kinetics of M 23 C 6 , γ', and G phases within SS316L cladding. Experimentally reported precipitation kinetics of SS316L in literature were linked to the kinetic parameters of the simulated precipitation in our KMC model. The model was then used to simulate microstructure evolution under synthetically generated treatments of varying temperature and radiation dose rate, for periods of up to 3000 hours. Changes in volume fraction, number density, and particle size of precipitates were recorded, and particle area fractions were correlated using statistical methods to develop the surrogate model. Simultaneously, the mechanical properties of the simulated microstructures were evaluated using microstructure-based finite element method (FEM) analysis to determine the elastic modulus, yield stress, ultimate tensile strength, and elongation to failure of the aged microstructures. Using this approach, our surrogate model can predict precipitation behavior within 0.25% volume fraction and mechanical properties within 6% relative error from the values predicted by the KMC and FEM models using 50 training simulations as input. The trained recurrent neural network-based model can return estimations of precipitation kinetics and mechanical properties ~1000 times faster than the physics-based codes. This work demonstrates, as a proof of concept, that reactor material service lifetimes under variable service conditions can be predicted for a statistics-based model from a practicably obtainable dataset.

36 MATERIALS SCIENCE↗

SU-C-12A-04: Diagnostic Imaging Research Using Decedents as a Proxy for the Living: Are Radiation Dosimetry and Tissue Property Measurements Affected by Post-Mortem Changes?

Purpose: Radiation dose (RD) from diagnostic imaging is a growing public health concern. Implanting dosimeters is a more accurate way to assess organ dose, relative to commonly used mathematical estimations. However, performing accurate dosimetry using live subjects is hindered by patient motion and safety considerations, which limit the RD and placement of implanted dosimeters. Performing multiple scans on the same subject would be the ideal way to assess the impact of dose reduction on image quality; however, performing multiple non-standard-of-care scans on live subjects for dosimetry and image quality measurements is generally prohibited by IRB committees. Our objective is to assess whether RD and tissue property (TP) measurements in post-mortem (PM) subjects are sufficiently similar to those in live subjects to justify the use of deceased subjects in future dosimetry and image quality studies. Methods: 4 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the RD at 4 levels (carina, lung, heart, and liver) during CT scanning. The CT protocol was performed ante-mortem (AM) and 2 and 3 hours PM. For TP analysis, additional scans were taken at 24 hours PM. To compare AM and PM TP, regions-of-interest were drawn on selected organs and the average CT density with standard deviation (in units of HU) were taken; additionally, visual comparisons of images were made at each PM interval. Results: No significant difference was observed in 8 of 9 measurements comparing AM and PM RD. Only one measurement (liver of the first subject) showed a significant difference (7% lower on PM measurement), possibly due to subject re-positioning. Initial TP visual and quantitative analyses show little to no change PM. Conclusion: Our results suggest that realistic radiation dosimetry and image quality measurements based on tissue properties can be performed reliably on recently deceased subjects.

60 APPLIED LIFE SCIENCES↗

Gamma-Ray-Induced Formation of Uranyl Peroxide Cage Clusters

Aqueous solutions of lithium uranyl triperoxide, Li 4 [UO 2 (O 2 ) 3 ] (LiUT), were irradiated with gamma rays at room temperature and found to form the uranyl peroxide cage cluster, Li 24 [(UO 2 )(O 2 )(OH)] 24 (Li–U 24 ). Raman spectroscopy and 18 O labeling were used to identify the Raman-active vibrations of LiUT. With these assignments, the concentration of LiUT was tracked as a function of radiation dose. A discrepancy between monomer removal and cluster formation suggests that the reaction proceeds by the assembly of an intermediate. Non-negative matrix factorization was used to separate Raman spectra into components and resulted in the identification of a unique intermediate species. Much of the conversion appears to be driven by water radiolysis products, particularly the hydroxyl radical. Furthermore, this differs from the 18 O-labeled copper-catalyzed formation of U 24 , which progresses at a steady rate with no observation of intermediates. Li–U 24 in solution decomposes at high radiation doses resulting in a solid insoluble product similar to Na-compreignacite, Na 2 (UO 2 ) 6 O 4 (OH) 6 ·7H 2 O, which contains uranyl oxyhydroxy sheets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The measurement of radiation exposure of astronauts by radiochemical techniques

The principal gamma-ray emitting radioisotopes, produced in the body of astronauts by cosmic-ray bombardment, which have half-lives long enough to be useful for radiation dose evaluation, are Be-7, Na-22, and Na-24. The sodium isotopes were measured in the preflight and postflight urine and feces, and those feces specimens collected during the manned Apollo missions, by analysis of the urine salts and the raw feces in large crystal multidimensional gamma-ray spectrometers. The Be-7 was chemically separated, and its concentration measured in an all NaI (TL), anticoincidence shielded, scintillation well crystal. The astronaut radiation dose in millirads, as determined for the Apollo 7, 8, 9, 10, 11, 12, and 13 missions, was 330, 160, smaller than 315, 870 plus or minus 550, 31, 110, and smaller than 250, respectively.

Brodzinski, R. L.↗

On a fundamental problem in radiation biology

Experimental evidence indicates that the radiation dose required to reduce a surviving population to a certain fraction of its original population is lower for vertebrate cells than for viruses. On the other hand, the number of ionizations per cell required to inactivate that cell is greater for vertebrate cells than for viruses. The apparent conflict between these two findings is investigated. It is found that the apparent contradiction is probably a result of the fractional power dependence of the radiation-dose value on the nucleic acid weight.

Dugan, V.↗

SU-D-304-03: Small Field Proton Dosimetry Using MicroDiamond and Gafchromic Film

Purpose: Certain dosimetric characteristics continue to make proton beam therapy an appealing modality for cancer treatment. The proton Bragg peak allows for conformal radiation dose delivery to the target while reducing dose to normal tissue and organs. As field sizes become very small the benefit of the Bragg peak is diminished due to loss of transverse equilibrium along the central beam axis. Furthermore, aperture scattering contributes additional dose along the central axis. These factors warrant the need for accurate small field dosimetry. In this study small field dosimetry was performed using two different methods. Methods: Small field dosimetry measurements were performed using a PTW microdiamond detector and Gafchromic EBT2 film for aperture sizes ranging from 0.5cm to 10cm and a proton range in water of 10cm to 27cm. The measurements were analyzed and then compared to each other and to reference dosimetry data acquired with a Markus chamber. Results: A decrease in normalized output is observed at small field sizes and at larger ranges in water using both measurement methods. Also, a large variation is observed between the output measurements by microdiamond and film at very small field sizes. At the smallest aperture, normalized output ranged from 0.16 to 0.72 and the percent difference between both measurement methods ranged from 36% to 70% depending on proton range. At field sizes above 5cm the film and microdiamond agree within 3%. Conclusion: Although both measurement methods exhibit a general decrease in output factor at small field sizes, dosimetric measurements for small fields using these two methods can vary significantly. Dosimetry under standard conditions is not sufficient to correctly model the dose distributions and outputs factors for small field sizes, additional small field measurements should be performed.

60 APPLIED LIFE SCIENCES↗

Assessment on Transport of Radioactive Species from Nuclear Facilities - 17079

It is generally recognized that radioactive nuclides are most hazardous fission products that could be released in the event of reactor accidents. The reactor coolant system of a pressurized water reactor (PWR) nuclear plant exhibits radioactivity from various sources. These radiation sources consist of the fission products from fuel element and activated products from corrosion products. The complex infrastructure of the processes does not allow detailed measurement of activity until after the reactor is shutdown. All of the components that require dismantling will be radioactive which was caused by neutron activation during operation, contamination by corrosion products, contamination by damaged by fuel rods and leaks by equipment. Due mainly to the various operation modes and their aging, there are the increasing needs to carry out repair works that are not sufficiently provided for by the original design. Many difficulties are involved in these tasks, namely, high radiation doses, cramped areas, hard to reach components, coupled with stringent quality conditions. The need to simulate the behavior of corrosion products in a nuclear power plant environment has attracted many researchers' attention. It has performed the in-depth reviews of the various theories and physics associated with the corrosion products transportation, the laboratory loop testing, and the field measurements in operating plants. Before we start the decommissioning of nuclear power plants, workers, the public and the environment shall be properly protected from radiation hazards. For this purpose, a safety assessment should be carried out relating to the potential hazards that may occur during the decommissioning. The radiological hazards involved in the decommissioning activities also should be identified, and be taken into account in the safety assessment. The radiation conditions of the primary circuit are determined by the activity of corrosion and fission products that have accumulated on the internal surfaces of the components. Therefore the estimation of contamination on the components is very important and, may be the first step in the reactor operation and decommissioning of components. The predominant radionuclide in the PWR primary coolant is Co-60, although Co-58 contributes significantly to radioactivity level at the early stage of a reactor operation. Since Co-60 is produced from the in-core Co-58, which is the source of cobalt in a reactor coolant system, many researchers have investigated its transmutation in the core, its transport around the system, and its subsequent deposition on surfaces. The major parameter influencing the behavior of radioactivity, such as Co-60 in the coolant, is the corrosion product oxides. The objective of this work is to analyze the corrosion product activity transported in the primary circuit by using a multi-region model. This model, which is incorporated with the mass and activity transport between the dissolved corrosion products in the coolant and the surface, describes the specific activity of corrosion products in coolant and on the surfaces according to the operation modes as well as decommissioning stage. In order to evaluate the analysis of the corrosion products in an integral type reactor, a multi-region mass balance model is applied. The specific activities of the various species on the surface of core and steam generator throughout the effective full power hours, 15,000 hours, are simulated for the various modes of operations. As a result, the specific activities of corrosion products from the surface of primary circuit were shown as very low compared to those of other commercial nuclear power plants. In this simulated reactor, a significant reduction of specific activities from the activated corrosion products is obtained due to the introduction of titanium alloy to the steam generator tube and the avoidance of boric acid induced corrosion. From this result we conclude that we are able to predict the level of radioactive nuclides generated by corrosion products in a primary circuit according to the various modes of operations by using multi-region model. In this point of view it is concluded that this multi-region model can be used as an engineering tool for analysis of the corrosion products within the primary coolant for the nuclear power plants. It is also considered that it is possible to extend to a calculation tool for estimating the radiological hazards involved in the decommissioning activities in terms of safety assessment. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Molecular analysis and comparison of radiation-induced large deletions of the HPRT locus in primary human skin fibroblasts

Genetic alterations in gamma-ray- and alpha-particle-induced HPRT mutants were examined by multiplex polymerase chain reaction (PCR) analysis. A total of 39-63% of gamma-ray-induced and 31-57% of alpha-particle-induced mutants had partial or total deletions of the HPRT gene. The proportion of these deletion events was dependent on radiation dose, and at the resolution limits employed there were no significant differences between the spectra induced by equitoxic doses of alpha particles (0.2-0.4 Gy) and gamma rays (3 Gy). The molecular nature of the deletions was analyzed by the use of sequence tagged site (STS) primers and PCR amplification as a "probe" for specific regions of the human X chromosome within the Xq26 region. These STSs were closely linked and spanned regions approximately 1.7 Mbp from the telomeric side and 1.7 Mbp from the centromeric side of the HPRT gene. These markers include: DXS53, 299R, DXS79, yH3L, 3/19, PR1, PR25, H2, yH3R, 1/44, 1/67, 1/1, DXS86, D8C6, DXS10 and DXS144. STS analyses indicated that the maximum size of total deletions in radiation-induced HPRT mutants can be greater than 2.7 Mbp and deletion size appears to be dependent on radiation dose. There were no apparent differences in the sizes of the deletions induced by alpha particles or gamma rays. On the other hand, deletions containing portions of the HPRT gene were observed to be 800 kbp or less, and the pattern of the partial deletion induced by alpha particles appeared to be different from that induced by gamma rays.

NASA Discipline Radiation Health↗

Extension of lymphocyte viability for radiation biodosimetry: Potential implications for radiological/nuclear mass casualty incidents

Abstract Dicentric chromosome assay (DCA) is routinely used for estimating the absorbed radiation dose in exposed humans. Optimal lymphocyte viability is crucial for reliable dose estimation and most cytogenetic laboratories prefer the receipt of blood samples within 24 to 36 hours after collection. Delays in the shipment/receipt of samples can occur sometimes under certain unforeseen circumstances: (1) Adverse weather conditions, (2) distant location of blood collection sites, and (3) shipping and handling of a large number of samples after radiological/nuclear mass casualty incident(s). To circumvent some of these limitations, we evaluated the suitability of ex vivo irradiated blood samples stored in the presence of phytohemagglutinin (PHA) for 7 days at ambient temperature (22‐24°C) for radiation biodosimetry. Blood samples stored in the presence of PHA for up to 7 days showed a higher mitotic index than blood samples stored without PHA. To verify the use of stored blood samples for DCA, frequencies of X‐rays induced dicentric chromosomes were analyzed in the blood samples that were cultured either 24 hours after exposure or 7 days later after storage. Our results indicate that storage of ex vivo irradiated blood samples in the presence of PHA at ambient temperature was found optimal for DCA and that the radiation doses estimated by dicentric chromosome frequencies were grossly similar between the fresh and stored blood samples. Our study suggests that reliable and accurate biodosimetry results can be obtained for triage using blood samples stored for up to a week at ambient temperature in the presence of PHA.

Smith, Tammy↗

Naturally induced secondary radiation in interplanetary space: Preliminary analyses for gamma radiation and radioisotope production from thermal neutron activation

Thermal neutron activation analyses were carried out for various space systems components to determine gamma radiation dose rates and food radiation contamination levels. The space systems components selected were those for which previous radiation studies existed. These include manned space vehicle radiation shielding, liquid hydrogen propellant tanks for a Mars mission, and a food supply used as space vehicle radiation shielding. The computational method used is based on the fast neutron distribution generated by the BRYNTRN and HZETRN transport codes for Galactic Cosmic Rays (GCR) at solar minimum conditions and intense solar flares in space systems components. The gamma dose rates for soft tissue are calculated for water and aluminum space vehicle slab shields considering volumetric source self-attenuation and exponential buildup factors. In the case of the lunar habitat with regolith shielding, a completely exposed spherical habitat was assumed for mathematical convenience and conservative calculations. Activation analysis of the food supply used as radiation shielding is presented for four selected nutrients: potassium, calcium, sodium, and phosphorus. Radioactive isotopes that could represent a health hazard if ingested are identified and their concentrations are identified. For nutrients soluble in water, it was found that all induced radioactivity was below the accepted maximum permissible concentrations.

Plaza-Rosado, Heriberto↗

The Measurement of Radiation Exposure of Astronauts by Radiochemical Techniques

The principal gamma-ray-omitting radioisotopes produced in the body of astronauts by cosmic-ray bombardment which have half-lives long enough to be useful for radiation dose evaluation are Be-7, Na-22, and Na-24. The sodium isotopes were measured in the preflight and postflight urine and feces, and those feces specimens collected during the manned Apollo missions, by analysis of the urine salts and the raw feces in large crystal multidimensional gamma-ray spectrometers. The Be-7 was chemically separated, and its concentration measured in an all Na(T1), anticoincidence shielded, scintillation well crystal. The overall sensitivity of the experiment was reduced by almost all variables such as low concentrations of excreted cosmogenic radionuclides, high concentrations of injected radionuclides, low sample sizes, long delay periods before analysis, and uncertain excretion rates. The astronaut radiation dose in millirads, as determined by this technique, for the Apollo 7, 8, 9, 10, 11, 12, and 13 missions was 330, 160, 315, 870 ? 550, 31, 110, and 250 respectively. In view of these limitations this technique would be best applied to cases of unusually high exposures, such as that encountered from solar flares.

R L Brodzinski↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Regulatory Considerations for Domestic Reprocessing Facility Physical Security

U.S. advanced non-light-water reactor vendors may pursue collocated on-site reprocessing activities. Therefore, these facilities are likely to possess formula quantities, or Category I quantities, of special nuclear material (SNM) during normal operations. The U.S. Nuclear Regulatory Commission (U.S. NRC) has yet to formally establish a regulatory framework for commercial reprocessing. While Category I requirements would explicitly not apply in this circumstance under current regulatory requirements, regulatory certainty does not exist. A novel framework should be developed to ensure public health and safety while also risk-informing the physical security requirements. This report reviews the relevant background of related rulemaking activities and proposes risk-informed physical protection requirements to satisfy these objectives. Insights from NRC security-related rulemaking activities provide a substantial technical basis to approach potential establishment of physical security requirements for reprocessing facilities. If a licensee can provide justification that the material satisfies a sufficient self-protecting radiation dose threshold, the material may not be subject to theft or diversion requirements and only potential sabotage requirements would apply. Furthermore, if the material can be justified to be moderately dilute, a set of risk-informed requirements could provide adequate protection of public health and safety. A revised performance objective for prevention of theft of moderately dilute Category I SNM may be detection to allow prompt recovery by a local law enforcement agency. However, a significant caveat to the proposed categorization scheme is the unknown integration of radiological sabotage with requirements for the protection against theft. Future licensees should consult with the NRC regarding treatment of this regulatory topic. Additionally, the self-protecting radiation dose threshold (either the existing or a proposed future threshold) would need to be considered. An integrated approach may apply graded potential requirements for protection against the design basis threat of radiological sabotage currently applicable to commercial nuclear power plants and Category I SNM facilities defined within 10 CFR 73.1(a).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

What happens when spins meet for ionizing radiation dosimetry?

Electron spin resonance (ESR) and magnetic resonance imaging (MRI) can be used to measure radiation dose deposited in different milieu through its effects. Radiation can break chemical bonds and if they produce stable free radicals, ESR can measure their concentration through their spins and a dose can be inferred. Ionizing radiation can also promote polymerization and in this case proton relaxation times can be measured and an image weighed by T2 can be produced giving spatial information about dose. A review of the basics of these applications is presented concluding with an end-to-end test using a composite Gel-Alanine phantom to validate 3-dimensionally dose distribution delivered in a simulation of Volume Modulated Arch Therapy on the simultaneous treatment of multiple brain metastases. The results obtained with the gel and alanine dosimeters are consistent with the expected by the treatment planning system, showing the potential of this multidosimetric approach and validating dosimetrically the multiple brain metastases treatment using VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗