Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I{sup 125} implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of {<=}10 ng/ml; and a Gleason score of {<=}6. All patients underwent transrectal ultrasound-guided radioactive I{sup 125} seed implantation into the prostate. The prescribed dose was 145 Gy to the prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable generalizability of the outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of iron phosphate ceramic waste form to immobilize radioactive waste solution

The objective of this research was to develop an iron phosphate ceramic (IPC) waste form using converter slag obtained as a by-product of the steel industry as a source of iron instead of conventional iron oxide. Both synthetic off-gas scrubber solution containing technetium-99 (or Re as a surrogate) and LiCl-KCl eutectic salt, a final waste solution from pyrochemical processing of spent nuclear fuel, were used as radioactive waste streams. The IPC waste form was characterized for compressive strength, reduction capacity, chemical durability, and contaminant leachability. Compressive strengths of the IPC waste form prepared with different types of waste solutions were 16 MPa and 19 MPa for LiCl-KCl eutectic salt and the off-gas scrubber simulant, respectively, which meet the minimum compressive strength of 3.45 MPa (500 psi) for waste forms to be accepted into the radioactive waste repository. The reduction capacity of converter slag, a main dry ingredient used to prepare the IPC waste form, was 4,136 meq/kg by the Ce(IV) method, which is much higher than those of the conventional Fe oxides used for the IPC waste form and the blast furnace slag materials. Average leachability indexes of Tc, Li, and K for the IPC waste form were higher than 6.0, and the IPC waste form demonstrated stable durability even after 63-day leaching. In addition, the Toxicity Characteristic Leach Procedure measurements of converter slag and the IPC waste form with LiCl-KCl eutectic salt met the universal treatment standard of the leachability limit for metals regulated by the Resource Conservation and Recovery Act. This study confirms the possibility of development of the IPC waste form using converter slag, showing its immobilization capability for radionuclides in both LiCl-KCl eutectic salt and off-gas scrubber solutions with significant cost savings.

converter slag↗

A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.

42 ENGINEERING↗

Chalcogenide Aerogels as Sorbents for Radioactive Iodine

Iodine ( 129 I and 131 I) is one of the radionuclides released in nuclear fuel reprocessing and poses a risk to public safety due to its involvement in human metabolic processes. In order to prevent the release of hazardous radioactive iodine into the environment, its effective capture and sequestration is pivotal. In the context of finding a suitable matrix for capturing radioactive iodine, several sulfidic chalcogels were explored as iodine sorbents including NiMoS 4 , CoMoS 4 , Sb 4 Sn 3 S 12 , Zn 2 Sn 2 S 6 , and K 0.16 CoS x (x = 4–5). All of the chalcogels showed high uptake, reaching up to 225 mass % (2.25 g/g) of the final mass owing to strong chemical and physical iodine–sulfide interactions. Analysis of the iodine-loaded specimens revealed that the iodine chemically reacted with Sb 4 Sn 3 S 12 , Zn 2 Sn 2 S 6 , and K 0.16 CoS x to form the metal complexes SbI 3 , SnI 4 , and, KI, respectively. In this study, the NiMoS 4 and CoMoS 4 chalcogels did not appear to undergo a chemical reaction with iodine since iodide complexes were not observed with these samples. Once heated, the iodine-loaded chalcogels released iodine in the temperature range of 75 to 220 °C, depending on the nature of iodine speciation. In the case of Sb 4 Sn 3 S 12 and Zn 2 Sn 2 S 6 , iodine release was observed around 150 °C mainly in the form of SnI 4 and SbI 3 , respectively. The NiMoS 4 , CoMoS 4 , and K 0.16 CoS x released elemental iodine at ~75 °C, which is consistent with physisorption. Preliminary investigations on consolidation of iodine-loaded Zn 2 Sn 2 S 6 chalcogel with Sb 2 S 3 as a glass forming additive produced glassy material whose iodine content was around 25 mass %.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of machine learning methods to classify radioactive elements using prompt-gamma-ray neutron activation data

The detection of illicit radiological materials is critical to establishing a robust second line of defence in nuclear security. Neutron-capture prompt-gamma activation analysis (PGAA) can be used to detect multiple radioactive materials across the entire Periodic Table. However, long detection times and a high rate of false positives pose a significant hindrance in the deployment of PGAA-based systems to identify the presence of illicit substances in nuclear forensics. In the present work, six different machine-learning algorithms were developed to classify radioactive elements based on the PGAA energy spectra. The model performance was evaluated using standard classification metrics and trend curves with an emphasis on comparing the effectiveness of algorithms that are best suited for classifying imbalanced datasets. We analyse the classification performance based on Precision, Recall, F1-score, Specificity, Confusion matrix, ROC-AUC curves, and Geometric Mean Score (GMS) measures. The tree-based algorithms (Decision Trees, Random Forest and AdaBoost) have consistently outperformed Support Vector Machine and K-Nearest Neighbours. Based on the results presented, AdaBoost is the preferred classifier to analyse data containing PGAA spectral information due to the high recall and minimal false negatives reported in the minority class.

97 MATHEMATICS AND COMPUTING↗

Simulated Performance of Algorithms for the Localization of Radioactive Sources from a Position Sensitive Radiation Detecting System (COCAE)

Simulation studies are presented regarding the performance of algorithms that localize point-like radioactive sources detected by a position sensitive portable radiation instrument (COCAE). The source direction is estimated by using the List Mode Maximum Likelihood Expectation Maximization (LM-ML-EM) imaging algorithm. Furthermore, the source-to-detector distance is evaluated by three different algorithms based on the photo-peak count information of each detecting layer, the quality of the reconstructed source image, and the triangulation method. These algorithms have been tested on a large number of simulated photons over a wide energy range (from 200 keV to 2 MeV) emitted by point-like radioactive sources located at different orientations and source-to-detector distances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New laser setup for the selective isotope production and investigation in a laser ion source at the IRIS (Investigation of Radioactive Isotopes on Synchrocyclotron) facility

New laser installation for the resonance ionization spectroscopy in a laser ion source and for rare isotope production has been recently put into operation at the IRIS (Investigation of Radioactive Isotopes on Synchrocyclotron) facility (Petersburg Nuclear Physics Institute, Gatchina). This is a significant improvement of a previous target-laser ion source device of the IRIS mass-separator, working on-line with 1 GeV proton beam of PNPI (Petersburg Nuclear Physics Institute) synchrocyclotron. It makes possible for us to get the isobarically clean radioactive isotope beams of a great number of chemical elements. New laser setup provides the two- or three-resonance step ionization in the range of wavelength of 265-850 nm. The first results obtained at the laser setup for Tl isotopes are presented.

07 ISOTOPE AND RADIATION SOURCES↗

Cosmic radioactivity and INTEGRAL results

Gamma-ray lines from radioactive decay of unstable isotopes co-produced by nucleosynthesis in massive stars and supernova have been measured since more than thirty years. Over the past ten years, INTEGRAL complemented the first sky survey made by COMPTEL. The {sup 26}A1 isotope with 1 My decay time had been first direct proof of currently-ongoing nucleosynthesis in our Galaxy. This has now become a tool to study the ∼My history of specific source regions, such as massive-star groups and associations in nearby regions which can be discriminated from the galactic-plane background, and the inner Galaxy, where Doppler shifted lines add to the astronomical information about bar and spiral structure. Recent findings suggest that superbubbles show a remarkable asymmetry, on average, in the spiral arms of our galaxy. {sup 60}Fe is co-produced by the sources of {sup 26}A1, and the isotopic ratio from their nucleosynthesis encodes stellar-structure information. Annihilation gamma-rays from positrons in interstellar space show a puzzling bright and extended source region central to our Galaxy, but also may be partly related to nucleosynthesis. {sup 56}Ni and {sup 44}Ti isotope gamma-rays have been used to constrain supernova explosion mechanisms. Here we report latest results using the accumulated multi-year database of INTEGRAL observations, and discuss their astrophysical interpretations, connecting to other traces of cosmic radioactivity and to other cosmic messengers.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated management of radioactive sources in Saudi Arabia

For usage of radioactive substances, any facility has to register and take license from relevant authority of the country in which such facility is operating. In the Kingdom of Saudi Arabia (KSA), the authority for managing radioactive sources and providing licenses to organizations for its usage is the National Center of Radiation Protection (NCRP). This paper describes the system that automates registration and licensing process of the National Center of Radiation Protection. To provide 24×7 accesses to all the customers of NCRP, system is developed as web-based application that provide facility to online register, request license, renew license, check request status, view historical data and reports etc. and other features are provided as Electronic Services that would be accessible to users via internet. The system also was designed to streamline and optimize internal operations of NCRP besides providing ease of access to its customers by implementing a defined workflow through which every registration and license request will be routed. In addition to manual payment option, the system would also be integrated with SADAD (online payment system) that will avoid lengthy and cumbersome procedures associated with manual payment mechanism. Using SADAD payment option license fee could be paid through internet/ATM machine or branch of any designated bank, Payment will be instantly notified to NCRP hence delay in funds transfer and verification of invoice could be avoided, SADAD integration is discussed later in the document.

07 ISOTOPE AND RADIATION SOURCES↗

Effect of geometrical configuration of radioactive sources on radiation intensity in beta-voltaic nuclear battery system: A preliminary result

It is known that one main problem in the application of beta-voltaic nuclear battery system is its low efficiency. The efficiency of the beta-voltaic nuclear battery system mainly depends on three aspects: source of radioactive radiation, interface between materials in the system and process of converting electron-hole pair to electric current in the semiconductor material. In this work, we show the effect of geometrical configuration of radioactive sources on radiation intensity of beta-voltaic nuclear battery system.

07 ISOTOPE AND RADIATION SOURCES↗

Fast pulsed operation of a small non-radioactive electron source with continuous emission current control

Non-radioactive electron sources are of great interest in any application requiring the emission of electrons at atmospheric pressure, as they offer better control over emission parameters than radioactive electron sources and are not subject to legal restrictions. Recently, we published a simple electron source consisting only of a vacuum housing, a filament, and a single control grid. In this paper, we present improved control electronics that utilize this control grid in order to focus and defocus the electron beam, thus pulsing the electron emission at atmospheric pressure. This allows short emission pulses and excellent stability of the emitted electron current due to continuous control, both during pulsed and continuous operations. As an application example, this electron source is coupled to an ion mobility spectrometer. Here, the pulsed electron source allows experiments on gas phase ion chemistry (e.g., ion generation and recombination kinetics) and can even remove the need for a traditional ion shutter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic molecular separation system for radioactive {sup 11}C ion acceleration

A {sup 11}C molecular production/separation system (CMPS) has been developed as part of an isotope separation on line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive {sup 11}C ion beams. In the ISOL system, {sup 11}CH{sub 4} molecules will be produced by proton irradiation and separated from residual air impurities and impurities produced during the irradiation. The CMPS includes two cryogenic traps to separate specific molecules selectively from impurities by using vapor pressure differences among the molecular species. To investigate the fundamental performance of the CMPS, we performed separation experiments with non-radioactive {sup 12}CH{sub 4} gases, which can simulate the chemical characteristics of {sup 11}CH{sub 4} gases. We investigated the separation of CH{sub 4} molecules from impurities, which will be present as residual gases and are expected to be difficult to separate because the vapor pressure of air molecules is close to that of CH{sub 4}. We determined the collection/separation efficiencies of the CMPS for various amounts of air impurities and found desirable operating conditions for the CMPS to be used as a molecular separation device in our ISOL system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a containment apparatus for synchrotron XAS measurements of radioactive fluid samples under high temperatures and pressures

The simple working principles and versatility of the hydrothermal diamond-anvil cell (HDAC) make it signifcantly useful for synchrotron x-ray studies of aqueous and fluid samples at high pressure-temperature (P-T) conditions. Yet, safety concerns need to be overcome in order to use the HDAC for synchrotron studies of aqueous radioactive samples at high temperatures and pressures. For accomplishment of such hydrothermal experiments of radioactive materials at synchrotron beamlines, the samples are required to be enclosed in a containment system employing three independent layers of airtight sealing at some synchrotron facilities while enabling access to the sample using several experimental probes, including incoming and outgoing x-rays. In this article, we report the design and implementation of a complete radiological safety enclosure system for an HDAC specialized for high P-T x-ray absorption spectroscopy (XAS) measurements of aqueous solutions containing the actinides at synchrotron beamlines. The enclosure system was successfully tested for XAS experiments using the HDAC with aqueous samples containing depleted uranium at temperatures ranging from 25 to 500 °C and pressures ranging from vapor pressure to 350 MPa.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributions of short-lived radioactive nuclei produced by young embedded star clusters

Most star formation in the Galaxy takes place in clusters, where the most massive members can affect the properties of other constituent solar systems. This paper considers how clusters influence star formation and forming planetary systems through nuclear enrichment from supernova explosions, where massive stars deliver short-lived radioactive nuclei (SLRs) to their local environment. The decay of these nuclei leads to both heating and ionization, and thereby affects disk evolution, disk chemistry, and the accompanying process of planet formation. Nuclear enrichment can take place on two spatial scales: (1) within the cluster itself (ℓ ∼ 1 pc), the SLRs are delivered to the circumstellar disks associated with other cluster members. (2) On the next larger scale (ℓ ∼ 2-10 pc), SLRs are injected into the background molecular cloud; these nuclei provide heating and ionization to nearby star-forming regions and to the next generation of disks. For the first scenario, we construct the expected distributions of radioactive enrichment levels provided by embedded clusters. Clusters can account for the SLR mass fractions inferred for the early Solar Nebula, but typical SLR abundances are lower by a factor of ∼10. For the second scenario, we find that distributed enrichment of SLRs in molecular clouds leads to comparable abundances. For both the direct and distributed enrichment processes, the masses of {sup 26}Al and {sup 60}Fe delivered to individual circumstellar disks typically fall in the range 10-100 pM {sub ☉} (where 1 pM {sub ☉} = 10{sup –12} M {sub ☉}). The corresponding ionization rate due to SLRs typically falls in the range ζ{sub SLR} ∼ 1-5 × 10{sup –19} s{sup –1}. This ionization rate is smaller than that due to cosmic rays, ζ{sub CR} ∼ 10{sup –17} s{sup –1}, but will be important in regions where cosmic rays are attenuated (e.g., disk mid-planes).

79 ASTRONOMY AND ASTROPHYSICS↗

Transfer reaction experiments with radioactive beams: from halos to the r-process

Transfer reactions are a powerful probe of the properties of atomic nuclei. When used in inverse kinematics with radioactive ion beams they can provide detailed information on the structure of exotic nuclei and can inform nucleosynthesis calculations. There are a number of groups around the world who use these reactions, usually with particle detection in large silicon arrays. Sometimes these arrays are coupled to gamma-ray detectors, and occasionally smaller arrays of silicon detectors are mounted within a solenoid magnet. Modern techniques using transfer reactions in inverse kinematics are covered, with specific examples, many from measurements made with beams from the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory.

Jones, K. L.↗

Methods to Account for CAP-88 PC-Omitted Nuclides in Radioactive Air Emissions From DOE Facilities

Routine research and development activities at US Department of Energy facilities can result in the release of radioactive emissions, potentially exposing the public and the environment. Such emissions are subject to certain Clean Air Act regulations, specifically those outlined in 40 CFR Part 61, Subpart H, which are enforced by the US Environmental Protection Agency. Compliance is determined in part with a dose standard. Doses to members of the public from most US Department of Energy facility airborne emissions are modeled using CAP-88 PC software, the latest version of which contains more than 1,200 radionuclides. Radioactive effluents from US Department of Energy facilities may contain radioisotopes that are not available in CAP-88 PC, and those radioisotopes must still be evaluated to determine whether doses to members of the public are below established limits. CAP-88 PC-omitted radionuclides can be accounted for using alternate methods, including the use of surrogate radionuclides. Here, this paper elucidates the process of accounting for CAP-88 PC-omitted radionuclides by providing criteria and rationale for surrogate selection, a compilation of surrogate radionuclides used in the past by US Department of Energy facilities, a discussion of alternate methods used to account for CAP-88 PC-omitted radionuclides and a comparison of methods and impacts on receptor doses. Ultimately, this paper aims to aid in the process of surrogate selection and consequently to simplify and expedite compliance with Clean Air Act regulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Superradiant Neutrino Lasers from Radioactive Condensates

Superradiance emerges from collective spontaneous emission in optically pumped gases, and is characterized by photon emission enhancements of up to $\frac{1}{4}$⁢𝑁 2 in an 𝑁 atom system. The gain mechanism derives from correlations developed within the decay medium rather than from stimulated emission as in lasing, so an analog of this process should be possible for fermionic final states. We introduce here the concept of superradiant neutrino emission from a radioactive Bose Einstein condensate, which can form the basis for a superradiant neutrino laser. A plausible experimental realization based on a condensate of electron-capture isotope 83 Rb could exhibit effective radioactive decay rates accelerated from 86.2 days to minutes in viably sized rubidium condensates of 10 6 atoms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cluster radioactivity of Og 176 118 294

According to theory, cluster radioactivity becomes an important decay mode in superheavy nuclei. We suggest that the strongly asymmetric fission, or cluster emission, is in fact the dominant fission channel for Og 176 118 294 , which is currently the heaviest synthetic isotope known. Our theoretical approach incorporates critical features of fission dynamics, including quantum tunneling and stochastic dynamics up to scission. We show that despite appreciable differences in static fission properties such as fission barriers and spontaneous fission lifetimes, the prediction of cluster radioactivity in Og 176 118 294 is robust with respect to the details of calculations, including the choice of energy density functional, collective inertia, and strength of the dissipation term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗