Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

MO-E-17A-06: Organ Dose in Abdomen-Pelvis CT: Does TG 111 Equilibrium Dose Concept Better Accounts for KVp Dependence Than Conventional CTDI?

Purpose: In CT imaging, a desirable quality assurance (QA) dose quantity should account for the dose variability across scan parameters and scanner models. Recently, AAPM TG 111 proposed to use equilibrium dose-pitch product, in place of CT dose index (CTDI100), for scan modes involving table translation. The purpose of this work is to investigate whether this new concept better accounts for the kVp dependence of organ dose than the conventional CTDI concept. Methods: The adult reference female extended cardiac-torso (XCAT) phantom was used for this study. A Monte Carlo program developed and validated for a 128-slice CT system (Definition Flash, Siemens Healthcare) was used to simulate organ dose for abdomenpelvis scans at five tube voltages (70, 80, 100, 120, 140 kVp) with a pitch of 0.8 and a detector configuration of 2x64x0.6 mm. The same Monte Carlo program was used to simulate CTDI100 and equilibrium dose-pitch product. For both metrics, the central and peripheral values were used together with helical pitch to calculate a volume-weighted average, i.e., CTDIvol and (Deq)vol, respectively. Results: While other scan parameters were kept constant, organ dose depended strongly on kVp; the coefficient of variation (COV) across the five kVp values ranged between 70–75% for liver, spleen, stomach, pancreas, kidneys, colon, small intestine, bladder, and ovaries, all of which were inside the primary radiation beam. One-way analysis of variance (ANOVA) for the effect of kVp was highly significant (p=3e−30). When organ dose was normalized by CTDIvol, the COV across the five kVp values reduced to 7–16%. The effect of kVp was still highly significant (p=4e−4). When organ dose was normalized by (Deq)vol, the COV further reduced to 4−12%. The effect of kVp was borderline significant (p=0.04). Conclusion: In abdomen-pelvis CT, TG 111 equilibrium dose concept better accounts for kVp dependence than the conventional CTDI. This work is supported by a faculty startup fund from the Cleveland State University.

60 APPLIED LIFE SCIENCES↗

Impact of particle loading and phase coupling on gas–solid flow dynamics: A case study of a two-phase, gas–solid flow in an annular pipe

The present study is devoted to a two-phase, gas–solid flow in an annular pipe (hollow cylinder) at an elevated pressure of 15 bars and moderate Reynolds number of circa 6000. The influence of the particle loading, the interaction between the phases, and turbulence dispersion on the flow dynamics is systematically studied by means of computational fluid dynamics simulations, employing the Ansys FLUENT commercial package. The cases with a particle volumetric fraction of 1.2% are referred to as “high particle loading,” and those with 0.13% are denoted as “low particle loading.” The following cases are investigated: (1) pure gas flow; (2) low particle loading two-phase flow with one-way coupling and with turbulence dispersion; (3) low particle loading two-phase flow with two-way coupling but without turbulence dispersion; (4) low particle loading two-phase flow with two-way coupling and with turbulence dispersion; (5) high particle loading two-phase flow with one-way coupling and with turbulence dispersion; (6) high particle loading two-phase flow with two-way coupling but without turbulence dispersion; and (7) high particle loading two-phase flow with two-way coupling and with turbulence dispersion. Additionally, the boundary layer is found to grow without fluctuations of the turbulent kinetic energy (TKE) for cases 1, 2, and 5. For case 4, the TKE fluctuations have been identified, although they appear to be less substantial than those in cases 6 and 7. The authors attribute the semi-chaotic nature of the TKE fluctuations to the particle loading and two-way coupling. In addition, the onset and development of the flow instability have been observed at a random axial distance in cases 4, 6, and 7. Such instability is also attributed to the two-way coupling with turbulence dispersion in the flow. It is concluded that the particle loading, one-way, or two-way coupling between the phases, and the turbulence dispersion models significantly influence the development of the flow dynamics with the same inlet and boundary conditions. Consequently, it is not a trivial question, which result a user should trust. The present computational results inspire to perform verification as well as experimental validation of the simulations, so the simulation results can subsequently be used with confidence for design analysis.

42 ENGINEERING↗

Integration of the Mini-Sulfide Sulfite Anthraquinone (MSS-AQ) Pulping Process and Black Liquor Gasification in a Pulp Mill

As many of the recovery boilers and other pieces of large capital equipment of U.S. pulp mills are nearing the end of their useful life, the pulp and paper industry will soon need to make long-term investments in new technologies. The ability to install integrated, complete systems that are highly efficient will impact the industry’s energy use for decades to come. Developing a process for these new systems is key to the adoption of state-of-the-art technologies in the Forest Products industry. This project defined an integrated process model that combines mini-sulfide sulfite anthraquinone (MSS-AQ) pulping and black liquor gasification with a proprietary desulfurization process developed by the Research Triangle Institute. Black liquor gasification is an emerging technology that enables the use of MSS-AQ pulping, which results in higher yield, lower bleaching cost, lower sulfur emissions, and the elimination of causticization requirements. The recently developed gas cleanup/absorber technology can clean the product gas to a state suitable for use in a gas turbine and also regenerate the pulping chemicals needed to for the MSS-AQ pulping process. The combination of three advanced technologies into an integrated design will enable the pulping industry to achieve a new level of efficiency, environmental performance, and cost savings. Because the three technologies are complimentary, their adoption as a streamlined package will ensure their ability to deliver maximum energy and cost savings benefits. The process models developed by this project will enable the successful integration of new technologies into the next generation of chemical pulping mills. When compared to the Kraft reference pulp, the MSS-AQ procedures produced pulps with a 10-15 % yield benefit and the ISO brightness was 1.5-2 times greater. The pulp refined little easier and had a slightly lower apparent sheet density (In both the cases). At similar levels of tear index the MSS-AQ pulps also produced a comparable tensile and burst index pulps. Product gas composition determined using computer simulations The results demonstrate that RVS-1 can effectively remove > 99.8% of the H2S present in simulated synthesis gas generated from the gasification of black liquor. This level of sulfur removal was consistent over simulated synthesis gas mixtures that contained from 6 to 9.5 vol % H2S.A significant amount of the sulfur in the simulated syngas was recovered as SO2 during regeneration. The average recovery of sulfur as SO2 was about 75%. Because these are first cycle results, this sulfur recovery is expected to improve. Developed WINGems model of the process.The total decrease in variable operating costs for the BLG process compared to the HERB was in excess of $6,200,000 per year for a mill producing 350,000 tons of pulp per year. This represents a decrease in operating cost of about $17.7/ton of oven dry pulp produced. There will be additional savings in labor and maintenance cost that has not been taken into account. The capital cost for the MSSAQ based gasifier system was estimated at $164,000,000, which is comparable to a High Efficiency Recovery Boiler. The return on investment was estimated at 4%. A gasifier replacement cannot be justified on its own, however if the recovery boiler needs to be replaced the MSSAQ gasifier system shows significantly higher savings. Before black liquor based gasifer technology can be commercialized more work is necessary. The recovery of the absorbed sulfur in the absorbent as sulfur dioxide is only 75%. This needs to be greater than 90% for economical operation. It has been suggested that as the number of cycles is increased the sulfur dioxide recovery might improve. Further research is necessary. Even though a significant amount of work has been done on a pilot scale gasifiers using liquors containing sulfur, both at low and high temperatures the lack of a commercial unit is an impediment to the implementation of the MSSAQ technology. The implementation of a commercial unit needs to be facilated before the benefits of the MSSAQ technology with ZnO absorbtion will become acceptable to the paper industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EnergyFit Nevada (formerly known as the Nevada Retrofit Initiative) final report and technical evaluation

The EnergyFit Nevada (EFN) Better Buildings Neighborhood Program (BBNP, and referred to in this document as the EFN program) currently encourages Nevada residents to make whole-house energy-efficient improvements by providing rebates, financing, and access to a network of qualified home improvement contractors. The BBNP funding, consisting of 34 Energy Efficiency Conservation Block Grants (EECBG) and seven State Energy Program (SEP) grants, was awarded for a three-year period to the State of Nevada in 2010 and used for initial program design and implementation. By the end of first quarter in 2014, the program had achieved upgrades in 553 homes, with an average energy reduction of 32% per home. Other achievements included: Completed 893 residential energy audits and installed upgrades in 0.05% of all Nevada single-family homes1 Achieved an overall conversation rate of 38.1%2 7,089,089 kWh of modeled energy savings3 Total annual homeowner energy savings of approximately $525,7523 Efficiency upgrades completed on 1,100,484 square feet of homes3 $139,992 granted in loans to homeowners for energy-efficiency upgrades 29,285 hours of labor and $3,864,272 worth of work conducted by Nevada auditors and contractors4 40 contractors trained in Nevada 37 contractors with Building Performance Institute (BPI) certification in Nevada 19 contractors actively participating in the EFN program in Nevada 1 Calculated using 2012 U.S. Census data reporting 1,182,870 homes in Nevada. 2 Conversion rate through March 31, 2014, for all Nevada Retrofit Initiative (NRI)-funded projects, calculated using the EFN tracking database. 3 OptiMiser energy modeling, based on current utility rates. 4 This is the sum of $3,596,561 in retrofit invoice value and $247,711 in audit invoice value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recovery Act: Oxy-Combustion Technology Development for Industrial-Scale Boiler Applications. Task 4 - Testing in Alstom's 15 MW th Boiler Simulation Facility

Alstom Power Inc. (Alstom), under U.S. DOE/NETL Cooperative Agreement No. DE-NT0005290, is conducting a development program to generate detailed technical information needed for application of oxy-combustion technology. The program is designed to provide the necessary information and understanding for the next step of large-scale commercial demonstration of oxy combustion in tangentially fired boilers and to accelerate the commercialization of this technology. The main project objectives include: Design and develop an innovative oxyfuel system for existing tangentially-fired boiler units that minimizes overall capital investment and operating costs; Evaluate performance of oxyfuel tangentially fired boiler systems in pilot scale tests at Alstom’s 15 MWth tangentially fired Boiler Simulation Facility (BSF); Address technical gaps for the design of oxyfuel commercial utility boilers by focused testing and improvement of engineering and simulation tools; Develop the design, performance and costs for a demonstration scale oxyfuel boiler and auxiliary systems; Develop the design and costs for both industrial and utility commercial scale reference oxyfuel boilers and auxiliary systems that are optimized for overall plant performance and cost; and, Define key design considerations and develop general guidelines for application of results to utility and different industrial applications. The project was initiated in October 2008 and the scope extended in 2010 under an ARRA award. The project is scheduled for completion by April 30, 2014. Central to the project is 15 MWth testing in the BSF, which provided in-depth understanding of oxy-combustion under boiler conditions, detailed data for improvement of design tools, and key information for application to commercial scale oxy-fired boiler design. Eight comprehensive 15 MWth oxy-fired test campaigns were performed with different coals, providing detailed data on combustion, emissions, and thermal behavior over a matrix of fuels, oxy-process variables and boiler design parameters. Significant improvement of CFD modeling tools and validation against 15 MWth experimental data has been completed. Oxy-boiler demonstration and large reference designs have been developed, supported with the information and knowledge gained from the 15 MWth testing. This report addresses the results from the 15 MWth testing in the BSF.

01 COAL, LIGNITE, AND PEAT↗

Investigation of enhanced CO 2 storage in deep saline aquifers by WAG and brine extraction in the Minnelusa sandstone, Wyoming

Geological CO 2 sequestration in deep saline aquifers has been extendedly investigated to reach the goal of carbon neutral as large amount of CO 2 can be reduced in a short time. Here, this study investigates the feasibility of water-alternating-gas (WAG) injection and brine extraction on enhancing CO 2 storage in a target deep saline aquifer, Minnelusa Sandstone in the Powder River Basin (PRB) of Wyoming. An integrated numerical model is developed to account for four scenarios: (1) CO 2 continuous injection (CI) through one injection well, (2) WAG injection through one injection well, (3) CO 2 CI through one injection well and brine extraction through one producer, (4) WAG injection through one injection well and brine extraction through one producer. Simulation results suggest that WAG injection and brine extraction corporately make it possible to enhance CO 2 injectivity while securing CO 2 storage safety. For instance, WAG injection considerably reduces structural trapping contribution while enhances dissolved and residual trapping contributions. As for brine extraction, it can decrease the maximum averaged reservoir pressure by 37% and 22% for CI and WAG injection, respectively. Besides, sensitive analyses of the operational parameters for the fourth scenarios are performed. Results reveal that, when the amount of total CO 2 injection has been predetermined, CO 2 injection time and rate within each period of WAG should be small whereas it is preferable to have large water injection time and rate. This is to secure desirable dissolved and residual trapping contributions (store CO 2 with safety). Sensitive degree results confirm that CO 2 injection rate, water injection time, and CO 2 injection time of WAG injection exhibit significant effects on CO 2 storage whereas the impacts of producer bottom-hole pressure (BHP), water injection rate, and CO 2 -water injection time are relatively weaker. This study not only sheds light on achieving double-win goal: enhance CO 2 injectivity and store CO 2 with safety, but also can be a critical reference for other CO 2 storage in deep saline aquifers.

58 GEOSCIENCES↗

NGEE Arctic Leaf Spectral Reflectance and Transmittance, Barrow, Alaska, 2014-2016

Data were collected to characterize the leaf-level optical properties and albedo of dominant Arctic tundra species in the Barrow, AK area and to enable trait scaling. Measurements of full-spectrum (i.e. 350-2500nm) leaf spectral reflectance of Arctic plant species. Data were collected in Barrow, Alaska during the 2014-2016 period. This dataset contains 5 zipped folders, 4 csv, 4 xlsx, 1 txt, and 1 pdf files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Technical Report on Waveform Fit Metrics for Global Models

The new WAVEFORMS Initiative in the Ground-based Nuclear Detonation Detection (GNDD) program includes an increased emphasis on the development of Earth models and methods to predict entire seismic and acoustic waveforms more accurately. In general, this increased emphasis is predicated on the need to better characterize seismic events and provide improved model-based discrimination between event types including earthquakes and explosions. More specifically, while current moment tensor inversion methods tend to work well for larger events (M>~4) using tuned 1-D Earth models, the development of state-of-the-art 3-D models and methods is required for the prediction of shorter period waves over large areas for discrimination of smaller events. There is no standard metric for model-based waveform prediction accuracy used in the waveform modeling/inversion community. However, there are several popular waveform misfit definitions; and minimizing the corresponding objective functions is the goal of waveform inversion. Some example misfit definitions employed for adjoint waveform tomography include measures of simple travel time differences (e.g. Tape et al., 2010), cross-correlation travel time differences (e.g. Luo and Schuster, 1991), multi-taper frequency dependent methods (e.g. Lei et al., 2020), time-frequency phase misfit functions (e.g. Fichtner 2010; Rodgers et al., 2022), normalized cross-correlation methods (e.g. Tao et al., 2018), and others. In some cases, these misfit definitions also involve complicated weighting schemes and summations over multiple frequency bands making it difficult to duplicate the misfit measurement with alternative models and datasets. Although each of the misfit definitions mentioned above are useful for developing waveform models, the actual misfit values are not usually meaningful outside of a given project, model, and/or dataset. Therefore, it is difficult to understand and communicate model performance for predicting waveforms and comparing to other models and/or new model iterations with a different dataset. Therefore, there is a need for a generalized method for evaluating overall model performance that is independent from the specific misfit chosen to develop the waveform models that is also intuitive and meaningful. In this report, we describe a new metric we refer to as ‘Percent of Correlated Signal’. The following sections describe and demonstrate the metric with a case study event and a more rigorous test using a random selection of globally distributed events. While the focus here is on global tomography models, the metric is meant to applicable to regional ‘wiggle-for-wiggle’ waveform models/studies as well.

58 GEOSCIENCES↗

ARM data-oriented metrics and diagnostics package for climate model evaluation (ARM-DIAGS-V3) version 3

A Python-based metrics and diagnostics package is currently being developed by the ARM Infrastructure Team at Lawrence Livermore National Laboratory to facilitate the use of long-term high frequency measurements from the ARM program in evaluating the regional climate simulation of clouds, radiation, precipitation, and aerosols. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The CMIP model data sets are also included in the package to enable model inter-comparison as demonstrated in Zhang et al. (2018) and Zhang et al. (2020). The mean of the CMIP model can be served as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, aerosol optical depth, and radiative fluxes, with plan to extend to more fields, such as the evaluation of model simulated aerosol physicochemical properties and cloud microphysics properties. Process-oriented diagnostics focusing on aerosol, cloud, and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. In addition to the Southern Great Plains (SGP), North Slope of Alaska (NSA) and Tropical Western Pacific (TWP) atmospheric observatories in the ARMDIAGS version 2.0, the version 3.0 package have extended to the data collected at the ARM Eastern North Atlantic (ENA) atmospheric observatory and the Observation and Modeling of the Green Ocean Amazon (GOAMAZON) field campaign. The metrics and diagnostics package are currently built upon standard Python libraries and additional Python packages developed by DOE (CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first provide an overview of major metrics in section 2. The input data, which constitutes the core content of the metrics and diagnostics package, is summarized in section 3. A user's guide documenting the workflow/structure of the version 3.0 codes and including step-by-step instruction for running the package is described in section 4.

54 ENVIRONMENTAL SCIENCES↗

Digital Architecture Planning Model

As part of the U.S. Department of Energy’s Light Water Reactor Sustainability Program, the Digital Architecture (DA) Project focuses on providing a model that nuclear utilities can refer to when planning deployment of advanced technologies. The digital architecture planning model (DAPM) is the methodology for mapping power plant operational and support activities into a DA that unifies all data sources needed by the utilities to operate their plants. The DA is defined as a collection of information technology capabilities needed to support and integrate a wide spectrum of real-time digital capabilities for performance improvements of nuclear power plants. DA can be thought of as integration of the separate instrumentation and control and information systems already in place in nuclear power plants, which are brought together for the purpose of creating new levels of automation in plant work activities. A major objective in DAPM development was to survey all key areas that needed to be reviewed in order for a utility to make knowledgeable decisions regarding needs and plans to implement a DA at the plant. The development was done in two steps. First, researchers surveyed the nuclear industry in order to learn their near-term plans for adopting new advanced capabilities and implementing a network (i.e., wireless and wire) infrastructure throughout the plant, including the power block. Secondly, a literature review covering regulatory documents, industry standards, and technical research reports and articles was conducted. The objective of the review was to identify key areas to be covered by the DAPM, which included the following: 1. The need for a DA and its benefits to the plant 2. Resources required to implement the DA 3. Challenges that need to be addressed and resolved to implement the DA 4. Roles and responsibilities of the DA implementation plan. The DAPM was developed based on results from the survey and the literature review. Model development, including the survey results and conclusions made about the key areas during the literature review, are described in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Parallel beamlet dose calculation via beamlet contexts in a distributed multi‐GPU framework

Purpose Dose calculation is one of the most computationally intensive, yet essential tasks in the treatment planning process. With the recent interest in automatic beam orientation and arc trajectory optimization techniques, there is a great need for more efficient model‐based dose calculation algorithms that can accommodate hundreds to thousands of beam candidates at once. Foundational work has shown the translation of dose calculation algorithms to graphical processing units ( GPU s), lending to remarkable gains in processing efficiency. But these methods provide parallelization of dose for only a single beamlet, serializing the calculation of multiple beamlets and under‐utilizing the potential of modern GPU s. In this paper, the authors propose a framework enabling parallel computation of many beamlet doses using a novel beamlet context transformation and further embed this approach in a scalable network of multi‐ GPU computational nodes. Methods The proposed context‐based transformation separates beamlet‐local density and TERMA into distinct beamlet contexts that independently provide sufficient data for beamlet dose calculation. Beamlet contexts are arranged in a composite context array with dosimetric isolation, and the context array is subjected to a GPU collapsed‐cone convolution superposition procedure, producing the set of beamlet‐specific dose distributions in a single pass. Dose from each context is converted to a sparse representation for efficient storage and retrieval during treatment plan optimization. The context radius is a new parameter permitting flexibility between the speed and fidelity of the dose calculation process. A distributed manager‐worker architecture is constructed around the context‐based GPU dose calculation approach supporting an arbitrary number of worker nodes and resident GPU s. Phantom experiments were executed to verify the accuracy of the context‐based approach compared to Monte Carlo and a reference CPU ‐ CCCS implementation for single beamlets and broad beams composed by addition of beamlets. Dose for representative 4 π beam sets was calculated in lung and prostate cases to compare its efficiency with that of an existing beamlet‐sequential GPU ‐ CCCS implementation. Code profiling was also performed to evaluate the scalability of the framework across many networked GPU s. Results The dosimetric accuracy of the context‐based method displays <1.35% and 2.35% average error from the existing serialized CPU ‐ CCCS algorithm and Monte Carlo simulation for beamlet‐specific PDD s in water and slab phantoms, respectively. The context‐based method demonstrates substantial speedup of up to two orders of magnitude over the beamlet‐sequential GPU ‐ CCCS method in the tested configurations. The context‐based framework demonstrates near linear scaling in the number of distributed compute nodes and GPU s employed, indicating that it is flexible enough to meet the performance requirements of most users by simply increasing the hardware utilization. Conclusions The context‐based approach demonstrates a new expectation of performance for beamlet‐based dose calculation methods. This approach has been successful in accelerating the dose calculation process for very large‐scale treatment planning problems ‐ such as automatic 4 π IMRT beam orientation and VMAT arc trajectory selection, with hundreds of thousands of beamlets ‐ in clinically feasible timeframes. The flexibility of this framework makes it as a strong candidate for use in a variety of other very large‐scale treatment planning tasks and clinical workflows.

Neph, Ryan↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of further calibration factors to be applied. The final accuracy of implantable MOSFETs when used for such kind of treatments was estimated to be within {+-}4%. Additional investigations using dose/fraction higher than 12 Gy, different beam configurations, and tracking systems could extend the present findings to other kind of treatments. MOSFET technology was proven to have high versatility in fast adaptation of existing detectors to new applications. It is plausible to expect a general feasibility of implantable MOSFET technology for in vivo dosimetry of the extracranial-targets treatments using the Cyberknife, provided each particular application will be validated by suitable both physical and clinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Notice of Submittal – 2023 Radionuclide Air Emissions Report for Los Alamos National Laboratory

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2023 and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s Rad NESHAP compliance program, which is part of the Environmental Protection and Compliance (EPC) Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Headquarters and EPA Region 6. The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL’s EDE was 0.43 for 2023. The annual limit is 10 millirem per year, established by the EPA in 40 CFR 61 Subpart H. All measured air emissions are modeled to a single location, known as the Maximally Exposed Individual (MEI). During calendar year 2023, LANL continuously monitored radionuclide emissions at 28 “major” release points, or stacks. The Laboratory estimates emissions from an additional 59 “minor” release points using radionuclide usage source terms in lieu of stack monitoring. Also, LANL uses an EPA approved network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates several meteorological monitoring towers. From these various systems, a comprehensive evaluation is conducted to calculate the MEI dose for the Laboratory. The MEI can be any member of the public at any off-site location where there is a residence, school, business, or office. In 2023, this MEI location was a business at 129 New Mexico State Road 4 (NM-4), located in the northern end of White Rock. The primary contributors to the off-site dose at this location are the ambient air data at that location combined with the collected potential emissions from unmonitored (minor) sources. Overall, the MEI dose in 2023 is similar to that which has been observed in recent years, and it remains well below the EPA’s 10 millirem per year limit. Doses reported to the EPA for the past 10 years are shown in Table E1.

54 ENVIRONMENTAL SCIENCES↗

Exploring the impacts of physics and resolution on aqua-planet simulations from a nonhydrostatic global variable-resolution modeling framework

Advances in computing resources are gradually moving regional and global numerical forecasting simulations towards sub-10 km resolution, but global high resolution climate simulations remain a challenge. The non-hydrostatic Model for Prediction Across Scales (MPAS) provides a global framework to achieve very high resolution using regional mesh refinement. Previous studies using the hydrostatic version of MPAS (H-MPAS) with the physics parameterizations of Community Atmosphere Model version 4 (CAM4) found notable resolution dependent behaviors. This study revisits the resolution sensitivity using the non-hydrostatic version of MPAS (NH-MPAS) with both CAM4 and CAM5 physics. A series of aqua-planet simulations at global quasi-uniform resolutions ranging from 240 km to 30 km and global variable resolution simulations with a regional mesh refinement of 30 km resolution over the tropics are analyzed, with a primary focus on the distinct characteristics of NH-MPAS in simulating precipitation, clouds, and large-scale circulation features compared to H-MPAS-CAM4. The resolution sensitivity of total precipitation and column integrated moisture in NH-MPAS is smaller than that in H-MPAS-CAM4. This contributes importantly to the reduced resolution sensitivity of large-scale circulation features such as the inter-tropical convergence zone and Hadley circulation in NH-MPAS compared to H-MPAS. In addition, NH-MPAS shows almost no resolution sensitivity in the simulated westerly jet, in contrast to the obvious poleward shift in H-MPAS with increasing resolution, which is partly explained by differences in the hyperdiffusion coefficients used in the two models that influence wave activity. With the reduced resolution sensitivity, simulations in the refined region of the NH-MPAS global variable resolution configuration exhibit zonally symmetric features that are more comparable to the quasi-uniform high-resolution simulations than those from H-MPAS that displays zonal asymmetry in simulations inside the refined region. Overall, NH-MPAS with CAM5 physics shows less resolution sensitivity compared to CAM4. These results provide a reference for future studies to further explore the use of NH-MPAS for high-resolution climate simulations in idealized and realistic configurations.

54 ENVIRONMENTAL SCIENCES↗

NbTa_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys niobium-tantalum (Nb-Ta). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach \cite{PAW}. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Nb. For Ta, p semi-core states as valence were chosen. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for ternary alloys is AXBYCZ, where A, B, and C refer to the constituents, and X, Y, and Z are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name case-N where N ranges between 11 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. Subdirectories with name case-N, where N ranges between 1 and 10 (extremes included) contain all the files listed above except 'vaspout.h5'. Subdirectories with name case-N, where N ranges between 41 and 60 (extremes included), contain a duplicate copy of the files listed above except for KPOINTS. The names of the duplicate files end with -bis, and correspond to a second VASP calculation that has converged to a different optimized geometry. This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. and Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. and Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal-amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. and Furthmüller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15-50 (1996) (4) Kresse, G. and Furthmüller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. and Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

TaV_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys tantalum-vanadium (Tanu-V). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the element V. For Ta, p semi-core states as valence were chosen. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter and OLCF-Summit using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for binary alloys is AXBY, where A and B refer to the constituents, whereas X and Y are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name case-N where N ranges between 11 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. Subdirectories with name case-N, where N ranges between 1 and 10 (extremes included) contain all the files listed above except 'vaspout.h5'. Subdirectories with name case-N, where N ranges between 41 and 60 (extremes included), contain a duplicate copy of the files listed above except for KPOINTS. The names of the duplicate files end with -bis, and correspond to a second VASP calculation that has converged to a different optimized geometry. This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. and Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. and Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal-amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. and Furthmuller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15-50 (1996) (4) Kresse, G. and Furthmuller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. and Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗