Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability & operability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Scale-Up of the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) System

The Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) system is designed for efficient, safe and reliable carbon dioxide (CO2) removal from cabin air on long-duration missions to the Moon, deep space, and Mars. CDRILS integrates an ionic liquid sorbent with hollow fiber membrane contactors for rapid CO2 removal and recovery. The liquid-based system provides continuous CO2 delivery, which avoids complicated valve networks to switch between absorbing and desorbing beds and enables simpler integration to the Sabatier without the need for the CO2 Management System (CMS). Ionic liquids are particularly desirable as liquid absorbents for space applications since they are non-volatile, non-odorous, and have high oxidative stability. The hollow fiber membrane contactors offer both high contact area and rigorous containment between the gas and liquid phases in a microgravity environment. Scale-up of the CDRILS technology has presented a series of fascinating challenges, since the interaction between hollow fiber properties, ionic liquid properties and performance is complex. Properties measured with lab-scale hollow fiber contactors are used to estimate the performance of contactors that are similar in scale to flight-scale demonstrations. To accomplish this, component and system models have been built to relate the key scrubber and stripper design and operating variables with performance, and experiments directed to validate the models have been performed. System size, weight and power are determined by component selection, arrangement, and operating conditions. Reliability will be extremely important for any long-range mission and depends on the stability of the ionic liquids and hollow fiber contactors. We report on our continuing long term stability experiments for the ionic liquid and contactor materials and our investigation of the physical properties of additional ionic liquids.

Yates, Stephen F.↗

Multi-Timescale Optimal Operation Framework for Integrated Economic and Reliability Analysis of Hybrid Power Plants

This paper introduces a hierarchical modeling framework for hybrid power plants (HPP) to facilitate the operation of HPP in power systems similar to conventional generators (Congens) in the integrated multi-timescale optimal operation framework. To consider the uncertainties of HPP renewable power in the day-ahead scheduling, distributionally robust optimization (DRO) is used. To ensure that the state-of-charge (SOC) of energy storage systems in HPPs aligns closely with the planned value for long-term reliability, real-time SOC management is incorporated. In addition, an adjustable real-time control is designed for the robust delivery of HPP real-time services. Case studies performed on a revised IEEE 39-bus system demonstrate the effectiveness of the proposed framework for HPP operation. Simulation results highlight that the proposed framework not only can help operators schedule HPP similar to Congens in varying weather conditions but can also maintain the frequency reliability of the system.

frequency stability↗

Harnessing Virtual Power Plants Reliably: Enabling tools for increased observability, controllability, operation, and aggregation of distributed energy resources

Harnessing virtual power plants enhances the integration of distributed energy resources into utility grids for a sustainable energy future. Virtual power plants (VPPs) aggregate DERs to enhance resource adequacy and reduce emissions. U.S. utilities are exploring various technologies to manage DERs effectively. FERC Order 2222 allows DERs to participate in both wholesale and retail markets. Enhancing observability and controllability of behind-the-meter (BTM) DERs is essential for reliable grid operations. A hierarchical control architecture can improve coordination among residential energy resources. Field tests showed nearly 20% energy savings and 30% peak power reduction during grid events. Effective management of DERs requires enhanced situational awareness to prevent grid congestion. Integrating DER management systems (DERMS) with existing planning tools can improve operational security. Near-real-time grid models can validate optimal resource set points against resource uncertainty. Traditional uninterruptible power supplies (UPS) can be upgraded to support grid services and become part of VPPs. Upgrading UPS systems can reduce costs by 75% and unlock significant battery capacity. New battery management systems and grid-aware controllers are essential for optimizing UPS performance. Continued research and development are necessary to address challenges in integrating DERs into utility grids. Encouraging customer participation in pilot programs is vital for the evolution of VPPs. Here, the shift towards price-responsive DERs and VPPs is expected to enhance energy distribution efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comprehensive assessment of deep reinforcement learning approaches for economic dispatch in nuclear-driven microgrids

As the electrical grid integrates more variable renewable energy sources such as wind and solar, the demand for distributed and flexible systems to address this increased variability becomes critical. Nuclear-driven microgrids provide a promising solution by offering stable generation to complement intermittent renewables, ensuring grid reliability and operating efficiency. This paper proposes a recurrent deep reinforcement learning framework for optimal economic dispatch in a nuclear-powered microgrid integrating renewable energy sources, small modular reactors, battery storage systems, and balance-of-plant dynamics. A three-agent control architecture is developed, where demand and renewable energy agents act as forecasters, and a reinforcement learning-based dispatch agent performs real-time energy allocation. A nonlinear programming formulation is first used to generate an optimal baseline for benchmarking. The proposed dispatch controller, based on Proximal Policy Optimization enhanced with Long Short-Term Memory networks, exploits temporal correlations in system dynamics by taking advantage of the time series used as inputs to improve policy robustness under uncertainty. Comparative analysis against established deep reinforcement learning methods, including Proximal Policy Optimization with a feedforward architecture, Soft Actor-Critic, and Twin Delayed Deep Deterministic Policy Gradient, demonstrates superior performance. Numerical results indicate that the proposed controller achieves a 0.39% cost reduction relative to the nonlinear programming benchmark and outperforms other learning-based methods by generating additional revenue of up to 0.35%. All reinforcement learning controllers compute dispatch actions in less than 0.3 s, resulting in a computational speedup of more than three orders of magnitude over the nonlinear programming baseline. The findings of this paper highlight their applicability for real-time operation and control in nuclear-integrated microgrids under volatile operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accurate and rapid acoustic damage characterization in complex structures using sparse sensor networks and deep learning models

Damage diagnosis in critical components is essential for ensuring the safety and reliability of operations across industries, spanning manufacturing, aerospace, and energy. Traditional acoustic nondestructive testing methods primarily focus on detecting defects through the direct scattering of single-mode incident waves from the damage, which limit their applicability to simple structures and small inspection areas. Our earlier research demonstrated that machine learning algorithms combined with sparse sensor networks can identify critical defect signatures even from multiply scattered, multi-mode acoustic signals, indicating the potential for improved defect inspection in complex, real-world structures. In this work, we demonstrate the successful implementation of this approach in a fixed sensor configuration to rapidly and accurately detect simulated defects in a geometrically complex, real-world structure, a brake rotor hub. Three different types of defects were physically simulated on the surface of the hub, and the collected data were used to train an autoencoder-based deep learning model. Two models were tested, one using single measurements and the other using multiple measurements taking advantage of the spatial distribution of the sensor network. After training, the multi-measurement model achieved 100 % accuracy in identifying, classifying, and locating unseen, unique damages. This work illustrates the potential of the proposed method for a wide range of industrial applications.

36 MATERIALS SCIENCE↗

Hydroclimate-coupled framework for assessing power system resilience under summer drought and climate change

Extreme drought, exacerbated by climate change, increasingly threatens power system resilience, and a systematic assessment of such impacts is challenging due to the unpredictability of drought and their associated modeling complexity. Here, to address the challenge, this research develops a hydroclimate-coupled power system resilience assessment framework that enables systematic modeling of drought and climate change impacts on generation, transmission, and demand sectors. Applying the framework to the 2025 Eastern U.S. power grid — comprising 6,055 at-risk generators — under climate-induced summer drought scenarios (including SSP126, SSP245, SSP370, and SSP585) from 2023 to 2100, the study finds that climate-induced droughts could jeopardize the power system’s reliability to a greater extent than historical events, potentially leading to widespread load shedding. More specifically, the study reveals that under the twenty-one representative drought scenarios, the loss of load expectation (LOLE) of the grid could range from 34.77 to 91.48 days per summer. The simulations indicate that implementing resilience enhancement strategies is crucial to ensure reliable system operation, which encompasses initiatives such as demand response, upgrading open cooling systems, and transmission expansion. In all, these findings underscore the urgent need for proactive planning and investment in resilient U.S. power systems to mitigate the impacts of extreme drought events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-overhead transversal fault tolerance for universal quantum computation

Fast, reliable logical operations are essential for realizing useful quantum computers. By redundantly encoding logical qubits into many physical qubits and using syndrome measurements to detect and correct errors, we can achieve low logical error rates. However, for many practical quantum error correction codes such as the surface code, owing to syndrome measurement errors, standard constructions require multiple extraction rounds—of the order of the code distance d—for fault-tolerant computation, particularly considering fault-tolerant state preparation. Here we show that logical operations can be performed fault-tolerantly with only a constant number of extraction rounds for a broad class of quantum error correction codes, including the surface code with magic state inputs and feedforward, to achieve ‘transversal algorithmic fault tolerance’. Through the combination of transversal operations7 and new strategies for correlated decoding, despite only having access to partial syndrome information, we prove that the deviation from the ideal logical measurement distribution can be made exponentially small in the distance, even if the instantaneous quantum state cannot be made close to a logical codeword because of measurement errors. We supplement this proof with circuit-level simulations in a range of relevant settings, demonstrating the fault tolerance and competitive performance of our approach. Furthermore, our work sheds new light on the theory of quantum fault tolerance and has the potential to reduce the space–time cost of practical fault-tolerant quantum computation by over an order of magnitude.

Zhou, Hengyun [QuEra Computing, Boston, MA (United↗

Enhanced plasma performance in C-2W advanced beam-driven field-reversed configuration experiments

TAE Technologies’ fifth-generation fusion device, C-2W (also called ‘Norman’), is the world’s largest compact-toroid device and has made significant progress in field-reversed configuration (FRC) plasma performance. C-2W produces record breaking, macroscopically stable, high-temperature advanced beam-driven FRC plasmas, dominated by injected fast particles and sustained in steady state, which is primarily limited by neutral-beam (NB) pulse duration. The NB power supply system has recently been upgraded to extend the pulse length from 30 ms to 40 ms, which allows for a longer plasma lifetime and thus better characterization and further enhancement of FRC performance. An active plasma control system is routinely used in C-2W to produce consistent FRC performance as well as for reliable machine operations using magnet coils, edge-biasing electrodes, gas injection and tunable-energy NBs. Google’s machine learning framework for experimental optimization has also been routinely used to enhance plasma performance. D

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Divertor Plasma Detachment Control Neural Network

DivControlNN is a state-of-the-art software tool that leverages advanced machine learning techniques to predict and control divertor plasma behavior in fusion reactors. Plasma, a highly energetic and electrically charged gas, requires meticulous management to protect reactor components and maintain optimal energy production. Conventional simulation methods, although extremely detailed, typically demand extensive computational time-making them unsuitable for real-time control scenarios. DivControlNN addresses this challenge by learning from tens of thousands of high-fidelity simulations, thereby creating a rapid surrogate model that can deliver near-instantaneous predictions. At the core of its functionality is a sophisticated technique known as latent space mapping, which condenses complex, high-dimensional plasma data into a compact, lower-dimensional representation. This streamlined representation enables the system to quickly forecast essential plasma properties and determine the precise conditions required for effective detachment. Detachment is a crucial process in which the plasma is cooled before reaching the divertor plates, thereby reducing heat loads and mitigating material erosion. In recent experiments conducted on the KSTAR tokamak in South Korea, DivControlNN successfully guided the detachment process without any fine-tuning-even when applied to a new tungsten divertor configuration. By achieving a computational speed-up of over one hundred million times compared to traditional simulation methods while maintaining low prediction errors, DivControlNN stands to significantly enhance real-time control and diagnostic capabilities in future fusion reactors. This breakthrough paves the way for safer, more reliable reactor operation and represents a major advancement toward realizing fusion energy as a practical, sustainable, and clean power source.

Xu, Xueqiao [Lawrence Livermore National Laborator↗

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are essential for detecting muons and neutrinos by capturing electrons released during particle collisions, which drift toward wire planes under an electric field and induce currents measured to reconstruct particle paths. However, LArTPCs face challenges from effects such as electron-ion recombination, electron diffusion, and electron attenuation, complicating data simulation. The Short Baseline Neutrino (SNB) detector aims to measure neutrinos before oscillation occurs. To bridge the gap between simulation and actual data, we propose modifying the amplitude and width of signals on the TPC wires, addressing uncertainties by adjusting signal characteristics to better match observed data. A Gaussian fit to current waveforms produces hits with associated charge and width, and by comparing data and simulated values, discrepancies highlight areas where the model fails. Initial results indicate the current modification algorithm may increase divergence between simulation and data, necessitating further refinement. A discovered bug in the WireModMakeHist_plug.cpp file, which incorrectly computed simulation and data ratios, underscores the need for precise algorithm adjustments. Future work involves correcting code errors, fine-tuning the model, and conducting multiple simulation runs to enhance statistical confidence and reduce uncertainties, ultimately aiming for accurate LArTPC operation and reliable neutrino detection.

Mkrtchyan, Ka'ren↗

Model Formulations: Integrating Distributed Energy Resources (DER) using Advanced Unit Commitment Models and DER Aggregation Methodologies

A distribution energy resource aggregator (DERA) constitutes a group of distribution energy resources with small generation capacities which meet the threshold to participate in the electricity wholesale market. This document provides the proposed DERA model formulation that will be implemented in the SCUC simulation’s architecture for the SCUC-DER project. Different economical assessment methodologies have been developed to incorporated bids for individual distributed resources, which include solar cost dispatch and cost model, BESS opportunity cost offer algorithm, and price sensitive demand response model. Detailed methods are proposed to aggregate individual cost offers to a DERA cost curve to bid in SCUC market while three methods are proposed to simulate DER actual dispatch. Based on the DERA models in this document, the SCUC-DER project will be able to assess the impacts of DERA on the distribution system’s operation and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modeling and Analysis for Large-Scale Renewable Energy Integration

Lina He will present dynamic modeling techniques for the integration of large-scale renewable energy systems. The presentation will address the challenges associated with high renewable penetration and provide frameworks for ensuring smooth and reliable grid operations.

Dynamic modeling, large-scale renewable integratio↗

High y + Shear-Stress Turbulence Implementation for High Flux Isotope Reactor Narrow Channel Flows

The research objective of this work was to improve the engineering predictions of the turbulence characteristics of flows in curved narrow channels. Such channel flows are commonly encountered in nuclear research and test reactors, with one of them being the high-flux isotope reactor (HFIR). Research reactors bear high heat fluxes, and the proper computing of turbulence is paramount for safe and reliable reactor operation. The study builds on the results of a previous direct numerical simulation of turbulence to inform a well-known Reynolds-averaged Navier–Stokes shear-stress turbulence model and improves its accuracy in simulating parallel channel flows. A new formulation of the loss term in the dissipation conservation equation is suggested. Combined with high wall distance computational grids, the new implementation provides a fast-running flow solution, suitable for engineering purposes. Model generalization for parallel channel flows, in a broader range of frictional Reynolds numbers, is suggested by introducing a new form of the model constants.

CFD↗

Automatic channel switching device

Automatic channel switching device operates with all three triple modular redundant channels when there are no errors. When a failure occurs, channel and module switching isolate the failure to a specific channel. Since only one must operate correctly, reliability is increased.

Ball, M.↗

Continuous analysis of nitrogen dioxide in gas streams of plants

Analyzer and sampling system continuously monitors nitrogen dioxide concentrations in the feed and tail gas streams of a facility recovering nitric acid. The system, using a direct calorimetric approach, makes use of readily available equipment and is flexible and reliable in operation.

Durkin, W. T.↗