Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resonance techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Resonant ultrasound spectroscopy for crystalline samples containing initial strain

Resonant ultrasound spectroscopy (RUS) is a mature and robust technique for the nondestructive characterization of the elastic properties of solids capable of providing the elastic constants of anisotropic crystalline solids. The traditional method is based on assuming that the solid is linear elastic and, therefore, obeys a linearized Hookean constitutive relationship (Hooke’s law). In this work, an alternative constitutive law is provided that allows for an initial strain or prestrain to be present stemming from residual stress. Then, the constitutive relationship is integrated into the RUS framework. The model is demonstrated using a realistic prestrain field obtained by simulating shot-peening processing of a polycrystalline Cu sample. The sensitivity of the resonances to the developed prestrain is established and discussed. This work allows researchers to consider the influence of initial strain or residual stress in their samples and the potential influence on accurate elastic constant estimates. The model also supports the potential of RUS for the nondestructive characterization of prestrain in materials.

42 ENGINEERING↗

Search for resonances in positron-atom systems

No one likes to see a scattering cross section curve that is too smooth; it is much more interesting to find bumps and wiggles and most interesting if it is possible to understand their cause. Several types of resonances were clearly established in positron-containing systems: those lying just below a degenerate threshold (like 2s-2p in hydrogenic atoms or ions) and those representing Coulomb bound states in a rearranged channel (like Ps + H reversing positron +H(-)). Recently, two new sorts of resonances have been reported for which the resonant mechanism is not clear. The first is a very low lying resonance in the e-Ps system (obtained by an adiabatic expansion method), and the second is a similarly low lying two channel resonance in the positron -H system (obtained by a close-coupling technique.) These developments encouraged the examination of such systems using the standard methods of stabilization and complex rotation. Most of the results are negative; the low lying resonances in either system are verified. Some indication of new resonances in the e(+)-He(+) system is found; this may be caused by the attraction between Ps in the n=2 state and the He(++) nucleus.

Bhatia, A. K.↗

Physical patterning of high-Q superconducting niobium resonators via ion beam etching

The development of superconducting quantum circuits increasingly involves the exploration of chemically distinct materials and complex multilayered structures. Accelerating this trend may benefit from low-damage, materials-agnostic patterning techniques that are compatible with a broad range of materials. Here, in this work, we investigate the utility of low-energy ion beam etching (IBE), a physical patterning technique, as an alternative to reactive ion etching for fabricating low-loss superconducting resonators. We use niobium (Nb) resonators as a test platform, leveraging their well-characterized performance metrics for benchmarking. To address IBE-induced surface redeposition, we introduce an in situ aluminum capping layer combined with targeted post-fabrication chemical treatment. This strategy yields resonators with internal quality factors as high as 6 × 10 5 in the single-photon regime at 50 mK. These results establish low-energy IBE as a promising patterning technique for superconducting devices, with the potential to accelerate development across chemically diverse and multilayered material platforms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Search for New Phenomena in Two-Body Invariant Mass Distributions Using Unsupervised Machine Learning for Anomaly Detection at s = 13 TeV with the ATLAS Detector

Searches for new resonances are performed using an unsupervised anomaly-detection technique. Events with at least one electron or muon are selected from 140 fb − 1 of p p collisions at s = 13 TeV recorded by ATLAS at the Large Hadron Collider. The approach involves training an autoencoder on data, and subsequently defining anomalous regions based on the reconstruction loss of the decoder. Studies focus on nine invariant mass spectra that contain pairs of objects consisting of one light jet or b jet and either one lepton ( e , μ ) , photon, or second light jet or b jet in the anomalous regions. No significant deviations from the background hypotheses are observed. Limits on contributions from generic Gaussian signals with various widths of the resonance mass are obtained for nine invariant masses in the anomalous regions. © 2024 CERN, for the ATLAS Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact Micromachined Infrared Bandpass Filters for Planetary Spectroscopy

The future needs of space based observational planetary and astronomy missions include low mass and small volume radiometric instruments that can operate in high radiation and low temperature environments. Here we focus on a central spectroscopic component, the bandpass filter. We model the bandpass response of the filters to target the wavelength of the resonance peaks at 20, 40, and 60 micrometers and report good agreement between the modeled and measured response. We present a technique of using common micromachining processes for semiconductor fabrication to make compact, free standing resonant metal mesh filter arrays with silicon support frames. The process can accommodate multiple detector array architectures and the silicon frame provides lightweight mechanical support with low form factor. We also present a conceptual hybridization of the filters with a detector array.

Merrell, Willie C., II↗

Selective Two-Photon Absorptive Resonance Femtosecond-Laser Electronic-Excitation Tagging (STARFLEET) Velocimetry in Flow and Combustion Diagnostics

Selective Two-Photon Absorptive Resonance Femtosecond-Laser Electronic-Excitation Tagging (STARFLEET), a non-seeded ultrafast-laser-based velocimetry technique, is demonstrated in reactive and non-reactive flows. STARFLEET is pumped via a two-photon resonance in N2 using 202.25-nm 100-fs light. STARFLEET greatly reduces the per-pulse energy required (30 μJ/pulse) to generate the signature FLEET emission compared to the conventional FLEET technique (1.1 mJ/pulse). This reduction in laser energy results in less energy deposited in the flow, which allows for reduced flow perturbations (reactive and non-reactive), increased thermometric accuracy, and less severe damage to materials. Velocity measurements conducted in a free jet of N2 and in a premixed flame show good agreement with theoretical velocities and further demonstrate the significantly less-intrusive nature of STARFLEET.

Jiang, Naibo↗

Resonant Doppler velocimetry in supersonic nitrogen flow

The development of the Resonant Doppler Velocimeter (RDV) is discussed. It is a new nonintrusive laser technique for flow diagnosis. The RDV technique is applied to supersonic nitrogen flow with sodium atoms as tracer particles. The measurements are achieved by shining a tunable single frequency laser beam into the flow. The resonant absorption spectrum of the seeded species is determined by observing the fluorescence signal intensity as a function of excitation wavelength. By comparing the peak absorption wavelength with a reference frequency marker, the flow velocity along the excitation beam can be obtained through the Doppler shift relation. By fitting the spectrum with a theoretical line profile, the static temperature and pressure of the flow an be determined.

Cheng, S. W. S.↗

Overview of the Magnetic Resonance Capabilities at INL

The aim of this presentation is to give a broad overview of the magnetic resonance capabilities at Idaho National Laboratory and how the technique is implemented within the different directorates at the lab. Historically, the high-field NMR instrumentation has been used by our Energy & Environment Science and Technology (EES&T) directorate primarily as a characterization tool for synthetic chemistry work, but we have been actively trying to expand the use of the instrumentation into our Nuclear Science and Technology (NS&T) and National and Homeland Security (NHS) directorates. The expanded scope of work has ranged from solid-state characterization of biomass, analysis of electrolyte materials from lithium ion batteries, quantification of extracted critical materials, and measurement of metal-ligand complexes using ligands proposed for use in the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Controllable surface-plasmon resonance in engineered nanometer epitaxial silicide particles embedded in silicon

Epitaxial CoSi2 particles in a single-crystal silicon matrix are grown by molecular-beam epitaxy using a technique that allows nanometer control over particle size in three dimensions. These composite layers exhibit resonant absorption predicted by effective-medium theory. Selection of the height and diameter of disklike particles through a choice of growth conditions allows tailoring of the depolarization factor and hence of the surface-plasmon resonance energy. Resonant absorption from 0.49 to 1.04 eV (2.5 to 1.2 micron) is demonstrated and shown to agree well with values predicted by the Garnett (1904, 1906) theory using the bulk dielectric constants for CoSi2 and Si.

Fathauer, R. W.↗

Frequency-Tunable Pre-stabilized lasers for LISA via Stabilized Lasers for LISA via Sideband Locking

This viewgraph presentation discusses a major potential source of noise for the Laser Interferometer Space Antenna (LISA) that is the laser frequency noise and the proposed mechanism to suppress the unstabilized frequency fluctuations. These fluctuations must be suppresed by about 12 orders of magnitude to achieve a stability that is sufficient for the detection of gravitational waves. This presentation reviews present a modification to the traditional cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This presentation also discusses measurements of the system stability, demonstrating that the pre-stabilization level satisfies LISA requirements and a demonstration of a phase-lock loop which utilizes the tunable sideband locking technique as a pre-stabilization stage.

Livas, Jeffrey↗

Characterization of Nanoscale Pores in Tight Gas Sandstones Using Complex Techniques: A Case Study of a Linxing Tight Gas Sandstone Reservoir

Pore structures with rich nanopores and permeability in tight gas reservoirs are poorly understood up to date. Advanced techniques are needed to be employed to accurately characterize pore structures, especially tiny pores which include micron and nanopores. In this study, various experimental techniques such as scanning electron microscopy (SEM), nuclear magnetic resonance (NMR) T 2 , nitrogen adsorption method, and NMR cryoporometry (NMRC) are combined to interrogate the complex pore systems of the tight gas reservoir in the Linxing formation, Ordos Basin, China. Results show that tight gas sandstones are primarily comprised of residual interparticle and clay-dominated pores. Clay and quartz are two dominate minerals while pyrite occupies a nontrivial amount as well. The permeability of tight gas sandstones is very low, exhibiting an extremely poor positive correlation with porosity. While pore types and relative pore contents are more influential factors on the permeability, accurate characterization of pore size distribution is critical for the permeability of tight gas sandstones. Therefore, complementary characterization methods are carried out, indicating that neither small pores with radii < 100 nm (around peak 1 in NMR T 2 distribution) nor large pores with radii > 5 μ m (around peak 3 in NMR T 2 distribution) control the permeability by analyzing the connectivity of the pores in various size ranges, but rather pores averaging approximately 350 ± X nm (around peak 2 in NMR T 2 distribution) have sufficient connectivity to host and transmit hydrocarbons. The pore size of tight gas sandstones is dominated by the clay-rich mineral assemblage. The study shows that the NMRC technique can be a very promising method, especially when referred to as a promising “roadmap” on how to interrogate tight formations such as the tight gas sands or even shale especially for the nanopore characterization.

15 GEOTHERMAL ENERGY↗

Combined Impedance Probe and Langmuir Probe Studies of the Low-Latitude E Region

The EQUIS-2 sounding rocket and radar campaign, launched from Kwajalein Atoll in 2004, included a mission to study low-latitude irregularities and electrodynamics, led by NASA GSFC. This mission included two instrumented rockets launched into the nighttime E region (apogee near 120 km), which included comprehensive electrodynamics and neutral density instrumentation. These rockets carried the first of a new generation of impedance probes, that utilize a wide-band drive signal to simultaneously measure the impedance of an antenna in a plasma as a function of frequency from 7 kEIz to 4 MHz. at a rapid cadence. This technique promises to permit true plasma spectroscopy, and resulted in the identification of multiple plasma resonances and accurate measurements of the plasma density, even in the low density nighttime E region. We present analyses of the technique and resulting spectra, and show how these data may be combined with fixed-bias Langmuir Probe data to infer the temperature structure of the E region as well as providing accurate absolute calibrations for the very high time resolution fixed-bias probe data. The data is shown to agree well with data from ionosonde, the ALTAIR radar, and the Peruvian beacon experiment.

Rowland, D. E.↗

O 2 based resonantly ionized photoemission thermometry analysis of supersonic flows

Characterization of the thermal gradients within supersonic and hypersonic flows is essential for understanding transition, turbulence, and aerodynamic heating. Developments in novel, impactful non-intrusive techniques are key for enabling flow characterizations of sufficient detail that provide experimental validation datasets for computational simulations. In this work, Resonantly Ionized Photoemission Thermometry (RIPT) signals are directly imaged using an ICCD camera to realize the techniques 1D measurement capability for the first time. The direct imaging scheme presented for oxygen-based RIPT (O 2 RIPT) uses the previously established calibration data to direct excite various resonant rotational peaks within the S-branch of the C 3 Π, ( v = 2) ← X 3 Σ( v ′ = 0) absorption band of O 2 . The efficient ionization of O 2 liberates electrons that induce electron avalanche ionization of local N 2 molecules generating N 2 + , which primarily deexcites via photoemissions of the first negative band of N 2 + ( B 2 Σ <#comment/> u + − <#comment/> X 2 Σ <#comment/> g + ) . When sufficient lasing energy is used, the ionization region and subsequent photoemission signal is achieved along a 1D line thus, if directly imaged can allow for gas temperature assignments along said line; demonstrated here of up to five centimeters in length. The temperature gradients present within the ensuing shock train of a supersonic under expanded free jet serves as a basis of characterization for this new RIPT imaging scheme. The O 2 RIPT results are extensively compared and validated against well-known and established techniques (i.e., CARS and CFD). The direct imaging capability fully realizes the technique’s fundamental potential and is expected to be the standard of implementation going forward. The direct imaging capability can play instrumental roles in future scientific studies that rely upon acute characterization of thermal gradients within a medium that cannot be easily resolved by a point. Furthermore, the removal of the spectrometer greatly reduces the cost, complexity, and optical alignment associated with prior RIPT measurements.

42 ENGINEERING↗

High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

NASA Discipline Number 26-10↗

Complex scaling in finite volume

Quantum resonances, i.e., metastable states with a finite lifetime, play an important role in nuclear physics and other domains. Describing this phenomenon theoretically is generally a challenging task. In this work, we combine two established techniques to address this challenge. Complex scaling makes it possible to calculate resonances with bound-state-like methods. Finite-volume simulations exploit the fact that the infinite-volume properties of quantum systems are encoded in how discrete energy levels change as one varies the size of the volume. Herein we apply complex scaling to systems in finite periodic boxes and derive the volume dependence of states in this scenario, demonstrating with explicit examples how one can use these relations to infer infinite-volume resonance energies and lifetimes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ab Initio Quantum Information Processor Design with Single-Molecule Magnets: A Multiscale Modeling Approach (Final Report)

This final report summarizes the team's efforts to develop a multiscale modeling approach that ranges from different levels of ab-initio quantum chemistry simulations to effective models and time-dependent external control, and to use this approach to systematically design quantum information processors with TbPc 2 single-molecule magnets. The impact of the work is two-fold: (i) New quantum chemistry simulation techniques capable of treating complex, multiscale problems such as the TbPc 2 molecule were developed, and (ii) the prospects for building quantum processors based on single-molecule magnets coupled by superconducting transmission line resonators were analyzed. The outcomes of this project revealed that current technology is at the cusp of being able to realize the main components of such a processor, and they highlighted the need to achieve stronger molecule-resonator interactions to enhance the viability of this approach. The multiscale modeling techniques developed during this project are general and transferable to other molecules and will thus have a broad impact on the field of quantum chemistry. Methods for controlling and simulating many coupled qubits developed here will also impact other quantum information technologies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved acoustic viscosimeter technique

An improved technique has been developed for studies of the shear viscosity of fluids. It utilizes an acoustic resonator as a four-terminal electrical device; the resonator's amplitude response may be determined directly and simply related to the fluid's viscosity. The use of this technique is discussed briefly and data obtained in several fluids is presented.

Fisch, M. R.↗

Resonance Scattering Treatment with the Windowed Multipole Formalism

A new method for directly sampling the resonance upscattering effect is presented. Alternatives have relied on inefficient rejection sampling techniques or large tabular storage of relative velocities. None of these approaches, which require pointwise energy data, are particularly well suited to the windowed multipole cross-section representation. The new method, called multipole analytic resonance scattering, overcomes these limitations by inverse transform sampling from the target relative velocity distribution where the cross section is expressed in the multipole formalism. The closed-form relative speed distribution contains a novel special function we deem the incomplete Faddeeva function, and we present the first results on its efficient numerical evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗