Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOLDERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Contactless Electroluminescence Imaging for Cell and Module Characterization

Module performance can be characterized by imaging using baseline and periodic images to track defects and degradation. Both thermal images, which can be acquired during sunny operating conditions, and photoluminescence images, which could be acquired at night, can be collected without electrical connection. Electroluminescence (EL) images, which are useful to detect many types of defects such as cracks, interconnect and solder faults, and resistances, have typically required electrical connection to drive current in the cells and modules. Here, a contactless EL imaging technique is proposed, which provides an EL image without the need for electrical connection to drive current through the module. Such EL imaging has the capability to be collected at night without disruption to daytime power generation.

14 SOLAR ENERGY↗

Development of Testing Methods to Predict Cracking in Photovoltaic Backsheets

In recent years there have been some significant failures of photovoltaic backsheets resulting from inadequacies of design that are not detected in current versions of the qualification standards. In some cases, this has resulted in catastrophic failure in less than 5 y of deployment. In this work, we develop a test sample construction and evaluate accelerated exposure conditions necessary to duplicate the cracking field failure of backsheets using a small and manageable coupon. This sample uses a piece of solder wire to put some controlled topology and stress into the backsheet. Through exposure to different environmental stressors it was found that the application of thermal cycling stresses, after ultraviolet radiation exposure, is of primary importance to duplicate field failures.

14 SOLAR ENERGY↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Conductive Adhesives for Metallization of Interdigitated Back Contact Solar Cells

The metallization and interconnection of Si solar cells to form a module is usually a multi-step process: cells are metallized individually, soldered into strings, and subsequently assembled into a module. Furthermore, the metallization process for individual cells must be compatible with the doped surfaces being contacted, which creates additional challenges when moving from diffused junctions to heterojunctions and/or passivated contact structures. To mitigate these problems and streamline module manufacturing for the case of interdigitated back contact (IBC) cell modules, we developed an approach wherein unmetallized IBC cells are bonded directly to a circuitized backsheet using a conductive adhesive (CA) that only conducts out-of-plane. The metal/CA/silicon stack is bonded by hot-pressing at 100-200 degrees C.For a CA consisting of ethylene vinyl acetate (EVA) filled with Ag-coated spheres or indium powder we find that contact resistivities in the range of 1-10 Wcm 2 are obtained, regardless of which conductive filler and which hot pressing parameters are used. XPS revealed that about 1-2 nm EVA residue bonds to the Si in these samples, suggesting the formation of an insulating barrier that is responsible for the high contact resistance. Using indium powder alone, improved contact resistivities <0.6 Wcm 2 , high shunt resistances, and an implied open-circuit voltage loss below 10 mV were obtained. Furthermore, a cost estimate is presented, indicating that substantial cost savings of up to $10/m 2 , or about $0.05/W DC , are possible through CA-based IBC module manufacturing.

14 SOLAR ENERGY↗

Employing Fracture Statistics to Track Cell Reliability Through Module Fabrication

In this work we demonstrate how fracture statistics may be employed to track cell reliability through module fabrication steps. We were able to detect how cell cutting equipment could reduce cell fracture strain by 25 % as well as increase its variability. A smaller reduction was found to result from the ribbon soldering operation, and all cells measured were weaker when strained in an orientation perpendicular to the gridlines. Cell fracture measurements were found to be consistent with the number of cracked cells experienced in full sized modules exposed to mechanical loading. A structural mechanics model was created to elucidate how the requisite fracture strain is developed in a cell encapsulated within a PV module and demonstrates that this strain decreases more than 50 % from its center to edge when placed within the inner loading span of four-point flexure. The associated implications on the apparent cell strength is examined with an effective volume treatment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Effect of Barrel Material on Critical Current Measurements of High-Jc RRP Nb3Sn Wires

Nb{sub 3}Sn strands extracted from a 20-strand rectangular Rutherford cable were reacted on either stainless steel or Ti-alloy barrels and the critical current, I{sub c}, in the field range of 8-11.5 T was measured on ITER-type barrels made from Ti-6Al-4V alloy, 304 stainless steel and G-10. Measurements on the 'standard' Ti-alloy barrel using the test procedure employed at BNL are shown to reproduce I{sub c} for extracted strands to {+-}2%. The I{sub c} data for the sample mounted on the 'standard' Ti-alloy are fit to the deviatoric strain scaling model developed for Nb{sub 3}Sn by the University of Twente group using an arbitrary pre-strain. Using the parameters for this fit, the I{sub c} data for the other barrels are fitted by only adjusting the strain. Using this procedure, the strain difference due to the barrel material is determined. Assuming a thermal pre-strain of -0.2% for the sample measured on the Ti-alloy barrel, the use of stainless steel barrel increases the compressive strain by -0.07%, that of G-10 by -0.10%. With the wire soldered to the stainless steel barrel, the strain increases to -0.15%. Details of this study are presented.

36 MATERIALS SCIENCE↗

Preliminary Design of JLAB Clas12 Large Superconducting Torus Magnet

Hall B at Jefferson Laboratory (JLAB) will need a 6-coil Torus producing a required integral of B-dl for an upgrade 12 GeV beam. In Sept. 2009, Wang NMR was awarded a contract to design, fabricate, assemble, deliver, and test at JLAB this ex citing magnet. The preliminary design review was completed by Dec. 2009 and intermediate design review will be completed by July 2010. Proto type coil construction, production of soldered conductor with SSC cable and final design review will be completed in 2010. We shall describe preliminary design and intermediate design for coil/cryostat, Torus central cylinder (hub), 48 cold mass suspensions, two intercoil support rings, cryocontrol tower, and adapter to Torus coil, magnet quench protection, and charge/ discharge con trol, and the two parallel path cooling design using supercritical helium. Because of coil in-plane and out-of-plane EM forces over these huge thin coils in addition to vacuum load, gravity load, and cool down thermal stress, we shall present the finite element analyses (FEA) on coil structure, 48 cold mass supports, intercoil cold rings, coil/ cryostat vacuum vessel, cryotower cryostat, and Torus hub. Finally, we shall shows that all pressure/ vacuum vessels and its weldment has satisfied ASME code.

43 PARTICLE ACCELERATORS↗

FMEA on the superconducting torus for the Jefferson Lab 12 GeV accelerator upgrade

As part of the Jefferson Lab 12GeV accelerator upgrade project, Hall B requires two conduction cooled superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. Both magnets are to be wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. This paper describes the various failure modes in torus magnet along with the failure modes that could be experienced by the torus and its interaction with the solenoid which is located in close proximity.

43 PARTICLE ACCELERATORS↗

Present Status and Recent Developments of the Twisted Stacked-Tape Cable Conductor

Here we discuss how the high magnetic field performance of a 40-tape twisted stacked-tape cable (TSTC) conductor made of 4-mm-width 0.1-mm-thick REBCO tapes was successfully tested. The critical current was 6.0 kA, with the n-value of 35, at 4.2 K with a background field of 17 T. No cyclic load effect was observed between 10 and 17 T with the maximum Lorentz load of 102 kN/m. Various issues, such as sample length, nonuniformity of termination resistances, and soldered joint of a coated tape cable, with regard to a TSTC conductor are discussed. Large-scale conductor designs of various scalable TSTC conductors are discussed, taking into account current densities and stabilizers.

2G cable↗

Minimum Quench Energy of Nb 3 Sn Wires With High Specific Heat Tape

A major problem of state-of-the-art Nb3Snaccelerator magnets is their long training due to thermo-mechanical perturbations. Increasing the specific heat, Cp, of the Rutherford cable would reduce and/or eliminate training by limiting the coils temperature rise. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using thin composite Cu/Gd 2 O 3 and Cu/Gd 2 O 2 S tapes produced by HyperTech Research, Inc. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. Wire samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for their Minimum Quench Energy (MQE). At 90%Ic and 15 T, the average gain of MQE of the Nb 3 Sn wire soldered to the Cu/Gd 2 O 2 S 55 μm thick ribbon was 2.5, and further increased at larger transport currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

Assembly of the MOLLER Toroidal Magnets at Jefferson Lab

The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. Here, this paper presents the assembly process for these five toroidal magnets, detailing critical steps including epoxy application, pin insertion, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.

Lamont, Joseph [Thomas Jefferson National Accelera↗

A Combined Computational and Mathematical Analysis of Interconnect Fatigue Potential in Photovoltaic Modules

A finite element model of a 60-cell monocrystalline silicon glass-polymer photovoltaic module was simulated with ±1.0 kPa and ±2.4 kPa loads applied to the glass to calculate the deformation under load. Cell-to-cell displacements were used to approximate interconnect strain and stress. A mathematical fatigue cycle life relation was fitted to data for the interconnect material (copper), to generate a life prediction at each interconnect location based on the local stress means, reversal extents, and amplitudes. Interconnect stress was found to be significantly asymmetric about zero despite symmetric positive and negative module loads due to laminate thickness offsets about the neutral plane and the effects of module framing. Cycle life results indicated that interconnect fatigue failure was unlikely to occur over a 30-year lifetime of conservative wind and snow load cycles since the typical cell design feature of leaving some unconstrained length between the cell edge and first solder pad increases the effective gauge length and decreases the stress levels below the material endurance limit. Follow-up analyses found that 3.6 mm and 6.4 mm were the minimum unconstrained lengths required to survive the assumed lifetime of wind and snow cycles, respectively, confirming that typical industrial module constructions with 8–15 mm unconstrained lengths should survive conservatively. Notably, large magnitude, low-cycle snow loading was consistently the limiting factor requiring a longer unconstrained interconnect length. Finally, insights and workflows from this study inform module interconnection design limits for survival against mechanical fatigue in deployment environments.

14 SOLAR ENERGY↗

Thermal Optimization of a Silicon Carbide, Half-Bridge Power Module

This project describes the modeling process to design the packaging and heat exchanger for a half-bridge wide-bandgap (WBG) power semiconductor module. The module uses two silicon carbide, metal-oxide-semiconductor field-effect transistor (MOSFET) devices per switch position that are soldered to an aluminum nitride, direct-bond copper (DBC) substrate. A baseplate cooling configuration (e.g., no thermal grease) is used along with a water-ethylene glycol, jet-impingement-style heat exchanger. The heat exchanger was designed to be fabricated using prototyping equipment from the National Renewable Energy Laboratory, complies with automotive standards (for minimal channel sizes, flow rates, and coolant), and considers reliability aspects (i.e., erosion/corrosion). Device-scale computational fluid dynamics (CFD) is used first to design the slot jet impingement cooling configuration and compute the effective heat transfer coefficient (HTC) of the concept. The computed HTCs are then used as boundary conditions for a finite element study to optimize the package geometry (e.g., device layout and baseplate thickness) to minimize thermal resistance and minimize temperature variation between the module's four devices. Finally, a fluid manifold is designed to generate the slot jets and cool the devices. Module-scale CFD predicts a relatively low junction-to-fluid thermal resistance of 16.7 mm2 K/W, a 1.4 degrees C temperature variation between devices, and a total pressure drop of 5,860 Pa (0.85 psi) for the design. The thermal resistance of the module design is about 67% lower than the 2015 BMW i3 power electronics/modules thermal resistance.

DIRECT ENERGY CONVERSION↗

WE-G-16A-01: Evolution of Radiation Treatment Planning

Welcome and Introduction - Lawrence N. Rothenberg This symposium is one a continuing series of presentations at AAPM Annual Meetings on the historical aspects of medical physics, radiology, and radiation oncology that have been organized by the AAPM History Committee. Information on previous presentations including “Early Developments in Teletherapy” (Indianapolis 2013), “Historical Aspects of Cross-Sectional Imaging” (Charlotte 2012), “Historical Aspects of Brachytherapy” (Vancouver 2011), “50 Years of Women in Medical Physics” (Houston 2008), and “Roentgen's Early Investigations” (Minneapolis 2007) can be found in the Education Section of the AAPM Website. The Austin 2014 History Symposium will be on “Evolution of Radiation Treatment Planning.” Overview - Radhe Mohan Treatment planning is one of the most critical components in the chain of radiation therapy of cancers. Treatment plans of today contain a wide variety of sophisticated information conveying the potential clinical effectiveness of the designed treatment to practitioners. Examples of such information include dose distributions superimposed on three- or even four-dimensional anatomic images; dose volume histograms, dose, dose-volume and dose-response indices for anatomic structures of interest; etc. These data are used for evaluating treatment plans and for making treatment decisions. The current state-of-the-art has evolved from the 1940s era when the dose to the tumor and normal tissues was estimated approximately by manual means. However, the symposium will cover the history of the field from the late-1950's, when computers were first introduced for treatment planning, to the present state involving the use of high performance computing and advanced multi-dimensional anatomic, functional and biological imaging, focusing only on external beam treatment planning. The symposium will start with a general overview of the treatment planning process including imaging, structure delineation, assignment of dose requirements, consideration of uncertainties, selection of beam configurations and shaping of beams, and calculations, optimization and evaluation of dose distributions. This will be followed by three presentations covering the evolution of treatment planning, which parallels the evolution of computers, availability of advanced volumetric imaging and the development of novel technologies such as dynamic multi-leaf collimators and online image guidance. This evolution will be divided over three distinct periods - prior to 1970's, the 2D era; from 1980 to the mid-1990's, the 3D era; and from the mid 1990's to today, the IMRT era. When the World was Flat: The Two-Dimensional Radiation Therapy Era” - Jacob Van Dyk In the 2D era, anatomy was defined with the aid of solder wires, special contouring devices and projection x-rays. Dose distributions were calculated manually from single field, flat surface isodoses on transparencies. Precalculated atlases of generic dose distributions were produced by the International Atomic Energy Agency. Massive time-shared main frames and mini-computers were used to compute doses at individual points or dose distributions in a single plane. Beam shapes were generally rectangular, with wedges, missing tissue compensators and occasional blocks to shield critical structures. Dose calculations were measurement-based or they used primary and scatter calculations based on scatter-air ratio methodologies. Dose distributions were displayed on line printers as alpha-numeric character maps or isodose patterns made with pen plotters. More than Pretty Pictures: 3D Treatment Planning and Conformal Therapy - Benedick A. Fraass The introduction of computed tomography allowed the delineation of anatomy three-dimensionally and, supported partly by contracts from the National Cancer Institute, made possible the introduction and clinical use of 3D treatment planning, leading to development and use of 3D conformal therapy in the 1980's. 3D computer graphics and 3D anatomical structure definitions made possible Beam's Eye View (BEV) displays, making conformal beam shaping and much more sophisticated beam arrangements possible. These conformal plans significantly improved target dose coverage as well as normal tissue sparing. The use of dose volume histograms, gross/clinical/planning target volumes, MRI and PET imaging, multileaf collimators, and computer-controlled treatment delivery made sophisticated planning approaches practical. The significant improvements in dose distributions and analysis achievable with 3D conformal therapy made possible formal dose escalation and normal tissue tolerance clinical studies that set new and improved expectations for improved local control and decreasing complications in many clinical sites. From the Art to the State of the Art: Inverse Planning and IMRT - Thomas R. Bortfeld While the potential of intensity modulation was recognized in the mid- 1980's, intensity-modulated radiotherapy (IMRT) did not become a reality until the mid-1990's. Broad beams of photons could be sub-divided into narrow beamlets whose intensities could be determined using sophisticated optimization algorithms to appropriately balance tumor dose with normal tissue sparing. The development of dynamic multi-leaf collimators (on conventional linear accelerators as well as in helical delivery devices) enabled the efficient delivery of IMRT. The evolution of IMRT planning is continuing in the form of Volumetric Modulated Arc Therapy (VMAT) and through advanced optimization tools, such as multi-criteria optimization, automated IMRT planning, and robust optimization to protect dose distributions against uncertainties. IMRT also facilitates “dose painting” in which different sub-volumes of the target are prescribed different doses. Clearly, these advancements are being made possible by the increasing power and lower cost of computers and developments in other fields such as imaging and operations research. Summary - Radhe Mohan The history does not end here. The advancement of treatment planning is expected to continue, leading to further automation and improvements in conformality and robustness of dose distributions, particularly in the area of particle therapy. Radiobiological modeling will gain emphasis as part of the planning process. Learning Objectives: The scope of changes in technology and the capabilities of radiation treatment planning The impact of these changes in the quality of treatment plans and optimality of dose distributions The impact of development in other fields (imaging, computers, operations research, etc.) on the evolution of radiation treatment planning.

60 APPLIED LIFE SCIENCES↗

TTW (Transition to Wire Device) [SWR-25-02]

The Transition to Wire (TTW) hardware project is a method for connecting solar research samples with fragile interconnects to robust, weatherproof and consistent commercial connectors. The Transition to Wire device is a printed circuit board designed to facilitate the transition from tab ribbon or other unsecured electrical contacts on research samples to either wires or a connector. The four pin connector provides a kelvin (4 wire) connection at the solder pad where the sample connects.

McDanold, Byron↗

Laser-induced breakdown spectroscopy in industrial and security applications

Laser-induced breakdown spectroscopy (LIBS) offers rapid, localized chemical analysis of solid or liquid materials with high spatial resolution in lateral and depth profiling, without the need for sample preparation. Principal component analysis and partial least squares algorithms were applied to identify a variety of complex organic and inorganic samples. This work illustrates how LIBS analyzers can answer a multitude of real-world needs for rapid analysis, such as determination of lead in paint and children's toys, analysis of electronic and solder materials, quality control of fiberglass panels, discrimination of coffee beans from different vendors, and identification of generic versus brand-name drugs. Lateral and depth profiling was performed on children's toys and paint layers. Traditional one-element calibration or multivariate chemometric procedures were applied for elemental quantification, from single laser shot determination of metal traces at {approx}10 {mu}g/g to determination of halogens at 90 {mu}g/g using 50-shot spectral accumulation. The effectiveness of LIBS for security applications was demonstrated in the field by testing the 50-m standoff LIBS rasterizing detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments and modelling of adhesive failure initiation of an epoxy underfill: a study of electronic packaging survivability

Epoxy underfills can be implemented in electronic packaging to enhance solder joint reliability of surface mounted components. However, it is important for an engineer to have a failure criterion that can be used for failure predictions and redesign of electronic assemblies. For this study, data from epoxy bond failure in mock electronic part assemblies were correlated to finite element analyses to predict adhesive failure initiation. Experiments were performed to determine failure loads for various loading locations and nonlinear viscoelastic analyses were performed for the same loading locations to determine a maximum principal strain failure parameter. Predictions showed that a maximum principal strain failure parameter defined from one test could be used as an indicator of adhesive failure of an epoxy bond undergoing other modes of loading. Failure initiation predictions matched experimental data using a maximum principal strain failure parameter for an epoxy bond undergoing mixed modes of loading for both unfilled and alumina oxide filled 828DEA epoxy. Such experimental setup is deemed appropriate for future epoxy testing.

42 ENGINEERING↗