Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Soil Samplers: New Techniques for Subsurface Sampling for Volatile Organic Compounds

Soil sampling techniques for volatile organic analysis must be designed to minimize loss of volatile organic compounds (VOCs) from the soil that is being sampled. Preventing VOC loss from soil cores that are collected from the subsurface and brought to the surface for subsampling is often difficult. Subsurface bulk sample retrieval systems are designed to obtain intact cylindrical cores of soil ranging anywhere from one to four inches in diameter, and one to several feet in length. The current technique that is used to subsample these soil cores for VOC analysis is to expose a horizontal section of the soil core to the atmosphere; screen the exposed soil using a photoionization detector (PID) or other appropriate device to locate contamination in the soil core; and use a hand-operated coring tool to collect samples from the exposed soil for analysis. Because the soil core can be exposed to the atmosphere for a considerable length of time during screening and sample collection, the current sub-sampling technique provides opportunity for VOCs to be lost from the soil. This report describes three alternative techniques from the current technique for screening and collecting soil samples from subsurface soil cores for VOC analysis and field testing that has been done to evaluate the techniques. Based on the results of the field testing, ASTM D4547, Standard Guide for Sampling Waste and Soils for Volatile Organic Compounds, was revised to include information about the new techniques.

54 ENVIRONMENTAL SCIENCES↗

Graph Sampling for Visual Analytics

Effectively visualizing large graphs and capturing the statistical properties are two challenging tasks. To aid in these two tasks, many sampling approaches for graph simplification have been proposed, falling into three categories: node sampling, edge sampling, and traversal-based sampling. It is still unknown which approach is the best. We evaluate commonly used graph sampling methods through a combined visual and statistical comparison of graphs sampled at various rates. We conduct our evaluation on three graph models: random graphs, small-world graphs, and scale-free graphs. Initial results indicate that the effectiveness of a sampling method is dependent on the graph model, the size of the graph, and the desired statistical property. This benchmark study can be used as a guideline in choosing the appropriate method for a particular graph sampling task, and the results presented can be incorporated into graph visualization and analysis tools.

97 MATHEMATICS AND COMPUTING↗

Ultra-Fast Sample Preparation for High-Throughput Proteomics

Sample preparation oftentimes can be the Achilles Heel of any analytical process and in the field of proteomics, preparing samples for mass spectrometric analysis is no exception. Current goals, concerning proteomic sample preparation on a large scale, include efforts toward improving reproducibility, reducing the time of processing and ultimately the automation of the entire workflow. This chapter reviews an array of recent approaches applied to bottom-up proteomics sample preparation to reduce the processing time down from hours to minutes. The current state-of-the-art in the field uses different energy inputs like microwave, ultrasound or pressure to perform the four basic steps in sample preparation: protein extraction, denaturation, reduction and alkylation, and digestion. No single energy input for enhancement of proteome sample preparation has become the universal gold standard. Instead, a combination of different energy inputs tend to produce the best results. This chapter further describes the future trends in the field such as the hyphenation of sample preparation with downstream detection and analysis systems. Finally, a detailed protocol describing the combined use of both pressure cycling technology and ultrasonic energy inputs to hasten proteomic sample preparation is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic-Based Robotic Sampling System for Radioactive Solutions

A novel microfluidic based robotic sampling system has been developed for sampling and analysis of liquid solutions in nuclear processes. This system couples the use of a microfluidic sample chip with a robotic system designed to allow remote, automated sampling of process solutions in-cell and facilitates direct coupling of the microfluidic sample chip with analytical instrumentation. This system provides the capability for near real time analysis, reduces analytical waste, and minimizes the potential for personnel exposure associated with traditional sampling methods. A prototype sampling system was designed, built and tested. System testing demonstrated operability of the microfluidic based sample system and identified system modifications to optimize performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards a Robust Sampling Approach: A Computational Review and Design

As pointed out in several other works, the estimation of the reliability of the electrical grid can not be conducted without the estimation of the stochastic phenomena of electicity demand and electricity production by variable renewable sources. Therefore, sampling procedures have become integral in the design of engineering structures and analysis. Commonly referred to as Monte Carlo uncertainty analysis or integration, the general objective of these procedures is to establish specifics about the uncertainty of an output characteristic of such an engineering system, given uncertainty about its input characteristics. These sampling procedures are applied in a context in which establishing such specifics cannot be performed through other means. Variance-reduction techniques are designed to lessen the variability among estimators to estimate statistics of those output uncertainties. Importance-sampling techniques, on the other hand, are designed to reduce the number of samples needed to estimate a particular statistic—e.g., a tail probability. The combination of these approaches can reduce the computational burden considerably for a particular estimator and statistic. Importance sampling—geared and designed as it is toward improving a particular estimator—suffers, unfortunately, from the unintended consequence of reducing the performance of other estimators in terms of their variance. The objective of this paper is to offer an alternative sampling procedure where this variance does not grow unacceptably large for a suite of estimators. Moreover, it is anticipated that, with additional knowledge of how an engineering output characteristic responds to its input characteristics, tuning parameters of the input’s sampling procedure can be set to improve the output characteristic’s estimation. This work proves the effectiveness of the suggested alternative approach. Such positive outcome will lead to a decrease of the computational burden of performing stochastic optimization of integrated energy systems (e.g., components dispatch, and portfolio composition). In particular, capturing the contribution to the overall system cost of rare and unlikely events and patterns of the electricity demand and production will become less computationally expensive. This is due to the fact that the approach demonstrated here will allow the sampling of those rare occurrences more frequently without misrepresenting their probabilistic impacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Expediting Groundwater Sampling at Hanford and Making It Safer - 13158

The CH2M HILL Plateau Remediation Company (CHPRC) manages the groundwater monitoring programs at the Department of Energy's 586-square-mile Hanford site in southeastern Washington state. These programs are regulated by the Resource Conservation and Recovery Act (RCRA), the Comprehensive Environmental Response Compensation and Liability Act (CERCLA), and the Atomic Energy Act (AEA). The purpose of monitoring is to track existing groundwater contamination from past practices, as well as other potential contamination that might originate from RCRA treatment, storage, and disposal (TSD) facilities. An integral part of the groundwater-monitoring program involves taking samples of the groundwater and measuring the water levels in wells scattered across the site. Each year, more than 1,500 wells are accessed for a variety of reasons. Historically, the monitoring activities have been very 'people intensive'. Field personnel or 'samplers' have been issued pre-printed forms showing information about the well(s) for a particular sampling evolution. This information is taken from two official electronic databases: the Hanford Well Information System (HWIS) and the Hanford Environmental Information System (HEIS). The samplers traditionally used these hardcopy forms to document the groundwater samples and well water-levels. After recording the entries in the field, the samplers turned the forms in at the end of the day and other personnel posted the collected information. In Automating Groundwater Sampling at Hanford (HNF-38542-FP Revision 0, Presented at Waste Management 2009 Conference, March 1 - March 5, 2009, Phoenix, AZ), we described the methods, tools, and techniques that would be used in automating the activities associated with measuring water levels. The Field Logging and Electronic Data Gathering (FLEDG) application/database that automates collecting the water-level measurement data has now been implemented at Hanford. In addition to eliminating the need to print out documents, the system saves three-to-four man days each month for the field personnel taking the measurements and the scientists and administrators managing the data and the documentation. After the information has received technical review, FLEDG automatically updates the database for water-level measurements and loads the document management system with the completed sampling report. Due to safety considerations, access to wells is conditional. A spreadsheet with appropriate data not only lists the wells that are cleared for work, but also the safety personnel who must be present before work can start. This spreadsheet is used in planning daily activities. Daily plans are structured to ensure that the wells to be sampled are cleared for work and the appropriate safety personnel have been assigned and are present before the work starts. Historically, the spreadsheets have been prepared manually, and as a result, are potentially subject to human error. However, a companion database application has been developed to work with FLEDG - making the entire sampling process more efficient and safer for personnel. The Well Access List - Electronic, WAL-E, is a database that contains much the same information that was previously manually loaded into the spread sheet. In addition, WAL-E contains a managed work-flow application that shows the access requirements and allows for appropriate reviews of the compiled well. Various CHPRC organizations, including Industrial Hygiene, RADCON, and Well Maintenance and Sample Administration are able to enter and review the wells added or deleted from the WAL-E database. The FLEDG system then accesses this database information to identify appropriate support personnel and provide safety requirements to field personnel. In addition, WAL-E offers the assurance that wells have appropriate locks and are correctly labeled and electrically grounded as required, before well activities begin. This feature is an extremely important aspect of the FLEDG/WAL-E system because it adds another safety check to the work evolution and reduces the potential for unsafe conditions to exist that would lead to a stop-work situation. This paper will further describe the technical aspects of both electronic programs/databases and their successful application at Hanford. (authors)

54 ENVIRONMENTAL SCIENCES↗

Small Scale Mixing Demonstration Batch Transfer and Sampling Performance of Simulated HLW - 12307

The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste treatment Plant (WTP) has been recognized as a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. At the end of 2009 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to EnergySolutions to design, fabricate and operate a demonstration platform called the Small Scale Mixing Demonstration (SSMD) to establish pre-transfer sampling capacity, and batch transfer performance data at two different scales. This data will be used to examine the baseline capacity for a tank mixed via rotational jet mixers to transfer consistent or bounding batches, and provide scale up information to predict full scale operational performance. This information will then in turn be used to define the baseline capacity of such a system to transfer and sample batches sent to WTP. The Small Scale Mixing Demonstration (SSMD) platform consists of 43'' and 120'' diameter clear acrylic test vessels, each equipped with two scaled jet mixer pump assemblies, and all supporting vessels, controls, services, and simulant make up facilities. All tank internals have been modeled including the air lift circulators (ALCs), the steam heating coil, and the radius between the wall and floor. The test vessels are set up to simulate the transfer of HLW out of a mixed tank, and collect a pre-transfer sample in a manner similar to the proposed baseline configuration. The collected material is submitted to an NQA-1 laboratory for chemical analysis. Previous work has been done to assess tank mixing performance at both scales. This work involved a combination of unique instruments to understand the three dimensional distribution of solids using a combination of Coriolis meter measurements, in situ chord length distribution measurements, and electro-resistive tomography. This current work utilized the same instruments to monitor simulated waste transfers. This paper will discuss some of the scaling compromises when it came to the scaled sampling system design, handling of large quantities of material for sampling, and present data for the discuss of likely behavior of the full scale DST based on scaling correlations using a scale ratio exponent (SRE) from 0.25 to 0.45 and the behavior observed in the SSMD platform. This does not establish a scaling factor for DST mixing using paired jet mixers but is an attempt to envelope the likely performance ranges in terms of certification sampling bias, certification sample root-mean-square-deviation, and bath to batch relative standard deviation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Delayed-Gamma Energy Biasing with Exact Energy Sampling in MCNP 6.2.0

Characterization of delayed-particle signatures is of the utmost importance for detecting, identifying, and quantifying special nuclear material (SNM). Various non-destructive assay (NDA) techniques used in nuclear material safeguards rely on characteristic gamma-ray or neutron emissions to infer properties of a material. The all-particle, all-energy Monte-Carlo radiation transport code MCNP6 is capable of simulating delayed-particle signatures from SNM in addition to modeling the transport of emitted particles to a detector or other instrument. In some cases, NDA techniques require the measurement of low probability emissions from a given material. In physical scenarios, this problem can be bypassed by longer count-times or may be simply irrelevant due to the mass, and therefore the total activity, of the material being measured. However, when applying the Monte-Carlo method to such scenarios, sampling of low probability emissions requires a large number of histories to converge to a statistically acceptable solution. To address this issue, the delayed-neutron and gamma energy biasing feature was introduced in MCNP6 by H. Armstrong et al. in 2013 which allows the user to set up energy windows in which delayed-particle emission sampling can be adjusted. For delayed-gamma sampling, this biasing method was based on the bin-wise structure of gamma emission data for both the multi-bin gamma and line-emission sampling modes. Recent improvements have been made to the line-emission sampling algorithm which upgrade the previous mini-bin sampling treatment to an exact energy-line treatment. This upgrade was not compatible with the biasing method implemented by H. Armstrong et al. due to the sampled data no longer having a bin-wise structure in line-emission mode. For this reason the delayed-gamma energy biasing feature has been rewritten to support the exact line-sampling treatment. This paper provides a description of the delayed-gamma energy biasing (DGEB) feature in MCNP6 as well as results and discussion for a gamma-ray spectroscopy example used to demonstrate the biasing utility. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The U-tube sampling methodology and real-time analysis of geofluids

The U-tube geochemical sampling methodology, an extension of the porous cup technique proposed by Wood [1973], provides minimally contaminated aliquots of multiphase fluids from deep reservoirs and allows for accurate determination of dissolved gas composition. The initial deployment of the U-tube during the Frio Brine Pilot CO{sub 2} storage experiment, Liberty County, Texas, obtained representative samples of brine and supercritical CO{sub 2} from a depth of 1.5 km. A quadrupole mass spectrometer provided real-time analysis of dissolved gas composition. Since the initial demonstration, the U-tube has been deployed for (1) sampling of fluids down gradient of the proposed Yucca Mountain High-Level Waste Repository, Armagosa Valley, Nevada (2) acquiring fluid samples beneath permafrost in Nunuvut Territory, Canada, and (3) at a CO{sub 2} storage demonstration project within a depleted gas reservoir, Otway Basin, Victoria, Australia. The addition of in-line high-pressure pH and EC sensors allows for continuous monitoring of fluid during sample collection. Difficulties have arisen during U-tube sampling, such as blockage of sample lines from naturally occurring waxes or from freezing conditions; however, workarounds such as solvent flushing or heating have been used to address these problems. The U-tube methodology has proven to be robust, and with careful consideration of the constraints and limitations, can provide high quality geochemical samples.

54 ENVIRONMENTAL SCIENCES↗

Application of a Liquid Extraction Based Sealing Surface Sampling Probe for Mass Spectrometric Analysis of Dried Blood Spots and Mouse Whole-Body Thin Tissue Sections

The utility of a liquid extraction based sealing surface sampling probe (SSSP) for the direct mass spectrometric analysis of targeted drugs and metabolites in dried blood spots (DBSs) and whole mouse thin tissue sections was demonstrated. The accuracy and precision for the quantitative analysis of a minimum of 50 ng/mL sitamaquine or acetaminophen in DBSs on paper were well within the required 15% dictated by internationally recognized acceptance criteria for assay validations. Analysis of whole-body mouse thin tissue sections from animals dosed with propranolol, adhered to an adhesive tape substrate, provided semi-quantitative information for propranolol and its hydroxyproranolol glucuronide metabolite within specific organs of the tissue. The relative abundances recorded for the two compounds in the brain, lung, kidney and liver were in nominal agreement with previously reported amounts based on analysis using a liquid microjunction surface sampling probe (LMJ-SSP), and whole-body autoradiography (WBA) and HPLC-MS analysis. The ability to sample and analyze from tape-adhered tissue samples, which are generally employed in WBA analysis, presents the possibility of consecutive WBA and SSSP-MS analysis of the same tissue section. This would facilitate assignment, and possibly quantitation, of the different molecular forms of total drug related material detected in the WBA analysis. The flexibility to sample larger or smaller spot sizes, alternative probe sealing mechanisms, and a reduction in internal volumes and associated sample carryover issues will be among the first simple improvements necessary to make the SSSP-MS method a practical DBS and/or thin tissue section analysis tool or to expand its use to other surface sampling applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Manual Sampling Locations for Regulatory and Emergency Response

Drinking water systems commonly use manual or grab sampling to monitor water quality, identify or confirm issues, and verify that corrective or emergency response actions have been effective. In this paper, the effectiveness of regulatory sampling locations for emergency response is explored. An optimization formulation based on the literature was used to identify manual sampling locations to maximize overall nodal coverage of the system. Results showed that sampling locations could be effective in confirming incidents for which they were not designed. When evaluating sampling locations optimized for emergency response against regulatory scenarios, the average performance was reduced by 3%–4%, while using optimized regulatory sampling locations for emergency response reduced performance by 7%–10%. Secondary constraints were also included in the formulation to ensure geographical and water age diversity with minimal impact on the performance. This work highlighted that regulatory sampling locations provide value in responding to an emergency for these networks.

54 ENVIRONMENTAL SCIENCES↗

Internet of Samples

Abstract Material samples are indispensable data sources in many natural science, social science, and humanity disciplines. More and more researchers recognize that samples collected in one discipline can be of great value for another. This has motivated organizations that manage a large number of samples to make their holdings accessible to the world. Currently, multiple projects are working to connect natural history and other samples managed by individual institutions or individuals into a universe of samples that follow FAIR principles. This poster reports the progress of the US NSF‐funded iSamples project, in the context of other efforts initiated by US DOE, DiSCCo, BCoN, and GBIF. By October 2021, we will also be able to present an iSamples prototype. We encourage individual organizations that hold material samples to get to know these projects and help shape these projects to realize the goal of a global linked sample cloud that connects all material samples and is accessible to all.

Richard, Stephen M.↗

Role of Ti Content on the Occurrence of the 3309-cm{sup –1} Peak in FTIR Absorption Spectra of Ruby Samples

The study is based on the determination of trace elements in ruby samples, Ti in particular, using laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS). The samples were then divided into three groups: high (≥ 200 ppma), moderate (100–200 ppma), and low (≤ 50 ppma) Ti content. In addition, X-ray absorption spectroscopy (XAS) was employed to confirm that the Ti oxidation state was Ti{sup 4+}. The heat experiment conditions were set at 800, 1200, and 1650°C to investigate the transformation of the –OH vibration in the FTIR spectra of ruby samples. The FTIR spectra showed that samples containing a low Ti concentration did not show the 3309-cm{sup –1} absorption peak either before or after heating at any of the designed temperatures. An obvious 3309-cm{sup –1} peak appeared only in samples with a moderate to high Ti content after heating at ≥ 1200°C. The results also suggest that, in addition of Ti{sup 4+}, the occurrence of the 3309-cm{sup –1} peak in the FTIR spectra is strongly affected by the charge compensation of –OH in Al sites, i.e., the structural –OH; thus, the structural –Ti–OH stretching in the ruby samples. Hence, for gemological identification, the 3309-cm{sup –1} peak can be applied to indicate whether a ruby has undergone heat treatment if those samples contain enough Ti ions in their structure, i.e., Ti ≥ 100 ppma. This condition is usually found in ruby samples from major deposits such as Mong Hsu and Mogok, Myanmar; Luc Yen, Vietnam; and Montopuez, Mozambique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production Procedure and Characterization of Zn-Doped Y-123 Superconducting Samples Prepared by Sol-Gel Method

The superconducting YBa{sub 2}Cu{sub 3−x}Zn{sub x}O{sub 7} (Y-123) bulk materials have been synthesized by using the sol-gel method. Samples are produced as undoped Y-123 and transition metal (Zn)-doped Y-123. Before the final heat treatment, the samples are calcined at 850 °C for 24 h. This process is repeated three times. Then, samples are sintered at 950 °C for 24 h in an air environment and at 500 °C for 5 h in an oxygen atmosphere. The synthesized products are characterized by XRD, R-T, and Vickers microhardness tester. The XRD investigation revealed that the prepared sample has an orthorhombic structure. According to XRD measurements, an orthorhombic structure has not changed with Zn doping. It was observed that undoped and Zn-doped samples have superconductivity properties by electrical measurements. T{sub c}{sup onset} is 89 K for undoped Y-123 sample, and the T{sub c}{sup onset} value decreases monotically with Zn addition. All samples show metallic behavior above T{sub c}{sup onset} temperature. As a result of Vickers microhardness measurements, it is observed that all samples have reverse indentation size effect (RISE) behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid determination of 226Ra in environmental samples

A new rapid method for the determination of {sup 228}Ra in natural water samples has been developed at the SRNL/EBL (Savannah River National Lab/ Environmental Bioassay Laboratory) that can be used for emergency response or routine samples. While gamma spectrometry can be employed with sufficient detection limits to determine {sup 228}Ra in solid samples (via {sup 228}Ac) , radiochemical methods that employ gas flow proportional counting techniques typically provide lower MDA (Minimal Detectable Activity) levels for the determination of {sup 228}Ra in water samples. Most radiochemical methods for {sup 228}Ra collect and purify {sup 228}Ra and allow for {sup 228}Ac daughter ingrowth for ~36 hours. In this new SRNL/EBL approach, {sup 228}Ac is collected and purified from the water sample without waiting to eliminate this delay. The sample preparation requires only about 4 hours so that {sup 228}Ra assay results on water samples can be achieved in < 6 hours. The method uses a rapid calcium carbonate precipitation enhanced with a small amount of phosphate added to enhance chemical yields (typically >90%), followed by rapid cation exchange removal of calcium. Lead, bismuth, uranium, thorium and protactinium isotopes are also removed by the cation exchange separation. {sup 228}Ac is eluted from the cation resin directly onto a DGA Resin cartridge attached to the bottom of the cation column to purify {sup 228}Ac. DGA Resin also removes lead and bismuth isotopes, along with Sr isotopes and {sup 90}Y. La is used to determine {sup 228}Ac chemical yield via ICP-MS, but {sup 133}Ba can also be used instead if ICP-MS assay is not available. Unlike some older methods, no lead or strontium holdback carriers or continual readjustment of sample pH is required.

54 ENVIRONMENTAL SCIENCES↗

Rapid determination of radiostrontium in seawater samples

A new method for the determination of radiostrontium in seawater samples has been developed at the Savannah River National Laboratory (SRNL) that allows rapid preconcentration and separation of strontium and yttrium isotopes in seawater samples for measurement. The new SRNL method employs a novel and effective pre-concentration step that utilizes a blend of calcium phosphate with iron hydroxide to collect both strontium and yttrium rapidly from the seawater matrix with enhanced chemical yields. The pre-concentration steps, in combination with rapid Sr Resin and DGA Resin cartridge separation options using vacuum box technology, allow seawater samples up to 10 liters to be analyzed. The total 89 Sr + 90 Sr activity may be determined by gas flow proportional counting and recounted after ingrowth of 90 Y to differentiate 89 Sr from 90 Sr. Gas flow proportional counting provides a lower method detection limit than liquid scintillation or Cerenkov counting and allows simultaneous counting of samples. Simultaneous counting allows for longer count times and lower method detection limits without handling very large aliquots of seawater. Seawater samples up to 6 liters may be analyzed using Sr Resin for 89 Sr and 90 Sr with a Minimum Detectable Activity (MDA) of 1-10 mBq/L, depending on count times. Seawater samples up to 10 liters may be analyzed for 90 Sr using a DGA Resin method via collection and purification of 90 Y only. If 89 Sr and other fission products are present, then 91 Y (beta energy 1.55 MeV, 58.5 day half-life) is also likely to be present. 91 Y interferes with attempts to collect 90 Y directly from the seawater sample without initial purification of Sr isotopes first and 90 Y ingrowth. The DGA Resin option can be used to determine 90 Sr, and if 91 Y is also present, an ingrowth option with using DGA Resin again to collect 90 Y can be performed. An MDA for 90 Sr of <1 mBq/L for an 8 hour count may be obtained using 10 liter seawater sample aliquots.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Efficient Surrogate Model Development: Impact of Sample Size and Underlying Model Dimensions

This study compares eight surrogate-model construction approaches using computational experiments. Here, the construction approaches considered include: Artificial Neural Networks (ANNs), Automated Learning of Algebraic Models using Optimization (ALAMO), Radial Basis Networks (RBNs), Extreme Learning Machines (ELMs), Gaussian Progress Regression (GPR), Random Forests (RFs), Support Vector Regression (SVR), and Multivariate Adaptive Regression Splines. Each approach is used to construct surrogate models for predicting the outputs of thirty-four test functions. The data used to construct surrogate models were generated using Latin Hypercube Sampling (LHS), Halton and Sobol sampling methods. We studied the impact of sampling method, sample size, and challenge function characteristics on the accuracy of surrogate model predictions. Our results revealed that for smaller sample sizes, on average, surrogate models trained using the data points generated by Sobol sequences provided the best estimation for all surrogate model construction approaches. As the sample size increased, the impact of sampling methods diminished. The comparison of surrogate-modeling construction approaches at large sample sizes revealed that surrogate models trained using ANN, ALAMO, and ELM yielded smaller root mean squared error and higher adjusted R-squared values than the models trained using the rest of the approaches.

42 ENGINEERING↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗