Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Jet production rates in association with W and Z bosons in pp collisions at $ \sqrt {s} = 7 {\text{TeV}} $

Measurements of jet production rates in association with W and Z bosons for jet transverse momenta above 30 GeV are reported, using a sample of proton-proton collision events recorded by CMS at sqrt(s) = 7 TeV, corresponding to an integrated luminosity of 36 inverse picobarns. The study includes the measurement of the normalized inclusive rates of jets sigma(V + >= n jets)/sigma(V), where V represents either a W or a Z. In addition, the ratio of W to Z cross sections and the W charge asymmetry as a function of the number of associated jets are measured. A test of Berends--Giele scaling at sqrt(s) = 7 TeV is also presented. The measurements provide a stringent test of perturbative-QCD calculations and are sensitive to the possible presence of new physics. The results are in agreement with the predictions of a simulation that uses explicit matrix element calculations for final states with jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid measurements of 235 U fission product isotope ratios using an online, high-pressure ion chromatography inductively coupled plasma mass spectrometry protocol with comparison to isotopic depletion models

An automated online separation–direct analysis method, RAPID (rapid analysis of post-irradiation debris), has been developed for the measurement of the concentration and isotopic composition of over 40 elements down to the low-picogram level. Here we discuss the application of RAPID to irradiated highly-enriched uranium, demonstrating that it has the sensitivity required to achieve precise, low-level analyses of non-natural isotopes, even in the presence of a bulk uranium matrix. As a result, isotopic ratios have been successfully measured at the low-picogram level, and the accuracy of these ratios was confirmed using an isotopic depletion and decay modeling software to within 1–2%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of Genes Associated With Progression and Metastasis of Advanced Cervical Cancers After Radiotherapy by cDNA Microarray Analysis

Purpose: To identify a set of genes related to the progression and metastasis of advanced cervical cancer after radiotherapy and to establish a predictive method. Methods and Materials: A total of 28 patients with cervical cancer (15 stage IIIB, 13 stage IVA patients) who underwent definitive radiotherapy between May 1995 and April 2001 were included in this study. All patients were positive for human papillomavirus infection and harbored the wild-type p53 gene. The expression profiles of 14 tumors with local failure and multiple distant metastasis and 14 tumors without metastasis (cancer free) obtained by punch biopsy were compared before treatment, using a cDNA microarray consisting of 23,040 human genes. Results: Sixty-three genes were selected on the basis of a clustering analysis, and the validity of these genes was confirmed using a cross-validation test. The most accurate prediction was achieved for 63 genes (sensitivity, 78.8%; specificity, 38.1%). Some of these genes were already known to be associated with metastasis via chromosomal instability (TTK, BUB1B), extracellular matrix components (matrix metalloproteinase 1 [MMP-1]), and carcinogenesis (protein phosphatase 1 regulatory subunit 7 [PPP1R7]). A 'predictive score' system was developed that could predict the probability for development of metastases using leave-one-out cross-validation methods. Conclusions: The present results may provide valuable information for identified predictive markers and novel therapeutic target molecules for progression and metastasis of advanced cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear state feedback, quadratic weights, and closed loop eigenstructures

Results are given on the relationships between closed loop eigenstructures, state feedback gain matrices of the linear state feedback problem, and quadratic weights of the linear quadratic regulator. Equations are derived for the angles of general multivariable root loci and linear quadratic optimal root loci, including angles of departure and approach. The generalized eigenvalue problem is used for the first time to compute angles of approach. Equations are also derived to find the sensitivity of closed loop eigenvalues and the directional derivatives of closed loop eigenvectors (with respect to a scalar multiplying the feedback gain matrix or the quadratic control weight). An equivalence class of quadratic weights that produce the same asymptotic eigenstructure is defined, sufficient conditions to be in it are given, a canonical element is defined, and an algorithm to find it is given. The behavior of the optimal root locus in the nonasymptotic region is shown to be different for quadratic weights with the same asymptotic properties.

Thompson, P. M.↗

Comparisons of one- and two- interface methods for tunnel wall interference calculation

Tunnel wall interference in two-dimensional subsonic flow can be analytically calculated on the basis of the one- or two-interface method. The application of numerical integration by means of matrix multiplication to both methods has been found to significantly reduce CPU time in on-line operation. An investigation of the sensitivity of these methods to random velocity-measurement disturbances shows the one-interface method to be less sensitive to measurement errors, and therefore to be preferable for practical applications.

Lo, C. F.↗

Probabilistic simulation of multi-scale composite behavior

A methodology is developed to computationally assess the probabilistic composite material properties at all composite scale levels due to the uncertainties in the constituent (fiber and matrix) properties and in the fabrication process variables. The methodology is computationally efficient for simulating the probability distributions of material properties. The sensitivity of the probabilistic composite material property to each random variable is determined. This information can be used to reduce undesirable uncertainties in material properties at the macro scale of the composite by reducing the uncertainties in the most influential random variables at the micro scale. This methodology was implemented into the computer code PICAN (Probabilistic Integrated Composite ANalyzer). The accuracy and efficiency of this methodology are demonstrated by simulating the uncertainties in the material properties of a typical laminate and comparing the results with the Monte Carlo simulation method. The experimental data of composite material properties at all scales fall within the scatters predicted by PICAN.

Liaw, D. G.↗

Perceptual Image Compression in Telemedicine

The next era of space exploration, especially the "Mission to Planet Earth" will generate immense quantities of image data. For example, the Earth Observing System (EOS) is expected to generate in excess of one terabyte/day. NASA confronts a major technical challenge in managing this great flow of imagery: in collection, pre-processing, transmission to earth, archiving, and distribution to scientists at remote locations. Expected requirements in most of these areas clearly exceed current technology. Part of the solution to this problem lies in efficient image compression techniques. For much of this imagery, the ultimate consumer is the human eye. In this case image compression should be designed to match the visual capacities of the human observer. We have developed three techniques for optimizing image compression for the human viewer. The first consists of a formula, developed jointly with IBM and based on psychophysical measurements, that computes a DCT quantization matrix for any specified combination of viewing distance, display resolution, and display brightness. This DCT quantization matrix is used in most recent standards for digital image compression (JPEG, MPEG, CCITT H.261). The second technique optimizes the DCT quantization matrix for each individual image, based on the contents of the image. This is accomplished by means of a model of visual sensitivity to compression artifacts. The third technique extends the first two techniques to the realm of wavelet compression. Together these two techniques will allow systematic perceptual optimization of image compression in NASA imaging systems. Many of the image management challenges faced by NASA are mirrored in the field of telemedicine. Here too there are severe demands for transmission and archiving of large image databases, and the imagery is ultimately used primarily by human observers, such as radiologists. In this presentation I will describe some of our preliminary explorations of the applications of our technology to the special problems of telemedicine.

Watson, Andrew B.↗

Observation of Electroweak Single Top Quark Production at the Tevatron

We report the first observation of single top quark production using ppbar collision data with sqrt{s}=1.96 TeV collected by the CDF II and D0 detectors at Fermilab. The significance of both the observed CDF and D0 data is 5.0 standard deviations, and the expected sensitivity is in excess of 5.9 and equal to 4.5 standard deviations, respectively. The single top production cross section and the CKM matrix element value |V_{tb}| have been measured.

Palencia, Enrique↗

Laser Desorption Postionization Mass Spectrometry of Antibiotic-Treated Bacterial Biofilms using Tunable Vacuum Ultraviolet Radiation

Laser desorption postionization mass spectrometry (LDPI-MS) with 8.0 ? 12.5 eV vacuum ultraviolet synchrotron radiation is used to single photon ionize antibiotics andextracellular neutrals that are laser desorbed both neat and from intact bacterial biofilms. Neat antibiotics are optimally detected using 10.5 eV LDPI-MS, but can be ionized using 8.0 eV radiation, in agreement with prior work using 7.87 eV LDPI-MS. Tunable vacuum ultraviolet radiation also postionizes laser desorbed neutrals of antibiotics and extracellular material from within intact bacterial biofilms. Different extracellular material is observed by LDPI-MS in response to rifampicin or trimethoprim antibiotic treatment. Once again, 10.5 eV LDPI-MS displays the optimum trade-off between improved sensitivity and minimum fragmentation. Higher energy photons at 12.5 eV produce significant parent ion signal, but fragment intensity and other low mass ions are also enhanced. No matrix is added to enhance desorption, which is performed at peak power densities insufficient to directly produce ions, thus allowing observation of true VUV postionization mass spectra of antibiotic treated biofilms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection sensitivity of laser-induced breakdown spectroscopy for Cr II in liquid samples

The performance of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of toxic metals such as Cr in water. Pure aqueous solutions (unitary matrix) with variable Cr concentration were used to construct calibration curves and to estimate the LIBS limit of detection (LOD). The calibration curves for Cr in a binary matrix (Cr plus Cd) and a tertiary matrix (Cr plus Cd and Co) were used to evaluate the matrix effect on the LOD. The LOD for Cr was found to be 1.1, 1.5, and 2.0 ppm (parts in 10{sup 6}) in a unitary, binary, and tertiary matrix, respectively. Once calibrated, the system was utilized for the detection and quantification of the Cr in tannery wastewater collected from different locations in the industrial area of Kanpur, India, where Cr concentrations were determined to be far higher than the U.S. Environmental Protection Agency safe drinking water limit of 0.05 ppm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature-sensitive photoluminescent CdSe-ZnS polymer composite film for lock-in photothermal characterization

The temperature dependence of the fluorescence spectrum of CdSe−ZnS core–shell quantum dots embedded in a polystyrene matrix is characterized between 30 °C and 60 °C. The spectrally integrated photoluminescence intensity is found to linearly decrease with −1.3%/ °C. This feature is exploited in a dual coating-substrate-configuration, consisting of a layer of this nanocomposite material, acting as a temperature sensor with optical readout, on top of an optically absorbing and opaque layer, acting as a photothermal excitation source, and covering a substrate material or structure of interest. From the frequency dependence of the optically detected photothermal signal in the frequency range between 5 Hz and 150 Hz, different thermal parameters of the constituent layers are determined. The fitted values of thermal properties of the different layers, determined in different scenarios in terms of the used a priori information about the layers, are found to be internally consistent, and consistent with literature values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

A Numerical Combination of Extended Boundary Condition Method and Invariant Imbedding Method Applied to Light Scattering by Large Spheroids and Cylinders

The extended boundary condition method (EBCM) and invariant imbedding method (IIM) are two fundamentally different T-matrix methods for the solution of light scattering by nonspherical particles. The standard EBCM is very efficient but encounters a loss of precision when the particle size is large, the maximum size being sensitive to the particle aspect ratio. The IIM can be applied to particles in a relatively large size parameter range but requires extensive computational time due to the number of spherical layers in the particle volume discretization. A numerical combination of the EBCM and the IIM (hereafter, the EBCM+IIM) is proposed to overcome the aforementioned disadvantages of each method. Even though the EBCM can fail to obtain the T-matrix of a considered particle, it is valuable for decreasing the computational domain (i.e., the number of spherical layers) of the IIM by providing the initial T-matrix associated with an iterative procedure in the IIM. The EBCM+IIM is demonstrated to be more efficient than the IIM in obtaining the optical properties of large size parameter particles beyond the convergence limit of the EBCM. The numerical performance of the EBCM+IIM is illustrated through representative calculations in spheroidal and cylindrical particle cases.

invariant imbeddings↗

Regulon inference without arbitrary thresholds: three levels of sensitivity

Reconstruction of transcriptional regulatory networks is one of the major challenges facing the bioinformatics community in view of constantly growing number of complete genomes. The comparative genomics approach has been successfully used for the analysis of the transcriptional regulation of many metabolic systems in various bacteria taxa. The key step in this approach is given a position weight matrix, find an optimal threshold for the search of potential binding sites in genomes. In our previous work we proposed an approach for automatic selection of TFBS score threshold coupled with inference of regulon content. In this study we developed two modifications of this approach providing two additional levels of sensitivity.

99 GENERAL AND MISCELLANEOUS↗

Analytic Sensitivities for Shape Optimization in Equivalent Plate Structural Wing Models

Equivalent plate modeling techniques based on Ritz analysis with simple polynomials prove to be efficient tools for structural modeling of wings in the preliminary design stage. Accuracy problems are encountered, however, when these models are used to obtain finite difference behavior sensitivities with respect to planform shape. The accuracy problems are associated with the poor numerical conditioning of static and eigenvalue equations. As higher-order polynomials are being used to Improve the analysis itself, the more sensitive is the finite difference derivative to the step size used. This article describes a formulation of wing equivalent plate modeling in which it is simple to obtain analytic, explicit expressions for stiffness and mass matrix elements without the need to perform numerical integration. This formulation leads naturally to analytic expressions for the derivatives of displacements, stresses, and natural frequencies with respect to shape design variables. This article examines the accuracy of finite difference derivatives compared with the analytic derivatives, and shows that In some cases it is impossible to obtain any information of value by finite differences. Analytic sensitivities, in this case, are still sufficiently accurate for design optimization.

Livne, Eli↗

Disentangling magnification in combined shear-clustering analyses

ABSTRACT We investigate the sensitivity to the effects of lensing magnification on large-scale structure analyses combining photometric cosmic shear and galaxy clustering data (i.e. the now commonly called ‘3 × 2-point’ analysis). Using a Fisher matrix bias formalism, we disentangle the contribution to the bias on cosmological parameters caused by ignoring the effects of magnification in a theory fit from individual elements in the data vector, for Stage-III and Stage-IV surveys. We show that the removal of elements of the data vectors that are dominated by magnification does not guarantee a reduction in the cosmological bias due to the magnification signal, but can instead increase the sensitivity to magnification. We find that the most sensitive elements of the data vector come from the shear-clustering cross-correlations, particularly between the highest redshift shear bin and any lower redshift lens sample, and that the parameters ΩM, $S_8=\sigma _8\sqrt{\Omega _\mathrm{ M}/0.3}$, and w0 show the most significant biases for both survey models. Our forecasts predict that current analyses are not significantly biased by magnification, but this bias will become highly significant with the continued increase of statistical power in the near future. We therefore conclude that future surveys should measure and model the magnification as part of their flagship ‘3 × 2-point’ analysis.

Thiele, Leander↗

Nanostructured materials for selective collection of trace-level metals from aqueous systems.

Nanostructured materials for selective collection of trace-level metals from aqueous systems A critical ability for responding to situations involving environmental contaminants is the ability to quickly identify the contaminant(s) involved and the scope of the contamination. Simple field-screening methods are needed to enable on-site, information allocation and decision making. Currently, analytical technology does not exist to allow quick, accurate, and efficient analysis. Existing field-screening methods lack the selectivity and sensitivity needed to provide key information. A large leap in performance is needed and is very unlikely to be achieved with incremental improvements in procedure, instrument design, or improved electronics. A new analytical approach is required. Deficiencies in selectivity and sensitivity can be addressed with high-performance sorbent materials capable of selectively concentrating the target analytes and removing them from the sample matrix. By concentrating and removing the target analyte, these sorbent materials provide a well-defined matrix for analysis. This chapter examines the use of nanostructured materials for the selective collection of trace-level metals from aqueous systems. The focus lies on thiol-functionalized materials. Focusing on thiol surface chemistry allows comparison of mesoporous silica, activated carbon, and superparamagnetic nanoparticles. The chapter also discusses zeolites, imprinted polymer materials, and activated carbon in general. The materials reviewed here are evaluated based on capacity, selectivity, and affinity for target analytes. Research presented here shows that correctly constructed nanostructured materials are superior to conventional sorbents.

nanomaterials, nanostructures, SAMMS, trace level ↗