Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Dark nuclei. I. Cosmology and indirect detection

In a companion paper Detmold et al. [Phys. Rev. D 90, 114506 (2014)], lattice field theory methods are used to show that in two-color, two-flavor QCD there are stable nuclear states in the spectrum. As a commonly studied theory of composite dark matter, this motivates the consideration of possible nuclear physics in this and other composite dark sectors. Here in this paper, early Universe cosmology and indirect detection signatures are explored for both symmetric and asymmetric dark matter, highlighting the unique features that arise from considerations of dark nuclei and associated dark nuclear processes. The present day dark matter abundance may be composed of dark nucleons and/or dark nuclei, where the latter are generated through dark nucleosynthesis. For symmetric dark matter, indirect detection signatures are possible from annihilation, dark nucleosynthesis, and dark nuclear capture and we present a novel explanation of the Galactic center gamma ray excess based on the latter. For asymmetric dark matter, dark nucleosynthesis may alter the capture of dark matter in stars, allowing for captured particles to be processed into nuclei and ejected from the star through dark nucleosynthesis in the core. Notably, dark nucleosynthesis realizes a novel mechanism for indirect detection signals of asymmetric dark matter from regions such as the Galactic center, without having to rely on a symmetric dark matter component.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axion Induced Oscillating Electric Dipole Moment of the Electron

A cosmic axion, via the electromagnetic anomaly, induces an oscillating electric dipole for the electron of frequency ma and strength ~(few) x 10 -32 e-cm, two orders of magnitude above the nucleon, and within a few orders of magnitude of the present standard model constant limit. We give a detailed study of this phenomenon via the interaction of the cosmic axion, through the electromagnetic anomaly, with particular emphasis on the decoupling limit of the axion, ∂ t a(t) ∝ m α → 0. The analysis is subtle, and we find the general form of the action involves a local contact interaction and a nonlocal contribution, analogous to the “transverse current” in QED, that enforces the decoupling limit. We carefully derive the effective action in the Pauli-Schroedinger non-relativistic formalism, and in Georgi’s heavy quark formalism adapted to the “heavy electron” (m e >> m a ). We compute the electric dipole radiation emitted by free electrons, magnets and currents, immersed in the cosmic axion field, and discuss experimental configurations that may yield a detectable signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin-to-Charge Conversion in Bi Films and Bi / Ag Bilayers

Thermally injected pure spin current phenomena have been explored in Bi / Y 3 Fe 5 O 12 and Bi / Ag / Y 3 Fe 5 O 12 structures at room temperature. We illustrate that although pure spin current has been injected into the Bi layer and the Bi / Ag bilayer, there is little detectable signal of spin-to-charge conversion, except the distinctive Nernst signal from the Bi layer, in sharp contrast to the inverse Rashba-Edelstein effect claimed in these systems.

36 MATERIALS SCIENCE↗

Limits on Stellar-Mass Compact Objects as Dark Matter from Gravitational Lensing of Type Ia Supernovae

We present that the nature of dark matter (DM) remains unknown despite very precise knowledge of its abundance in the Universe. An alternative to new elementary particles postulates DM as made of macroscopic compact halo objects (MACHO) such as black holes formed in the very early Universe. Stellar-mass primordial black holes (PBHs) are subject to less robust constraints than other mass ranges and might be connected to gravitational-wave signals detected by the Laser Interferometer Gravitational-Wave Observatory (LIGO). New methods are therefore necessary to constrain the viability of compact objects as a DM candidate. Here we report bounds on the abundance of compact objects from gravitational lensing of type Ia supernovae (SNe). Current SNe data sets constrain compact objects to represent less than 35.2% (Joint Lightcurve Analysis) and 37.2% (Union 2.1) of the total matter content in the Universe, at 95% confidence level. The results are valid for masses larger than ~ 0.01 M ⊙ (solar masses), limited by the size SNe relative to the lens Einstein radius. We demonstrate the mass range of the constraints by computing magnification probabilities for realistic SNe sizes and different values of the PBH mass. Our bounds are sensitive to the total abundance of compact objects with M ≳ 0.01 M ⊙ and complementary to other observational tests. These results are robust against cosmological parameters, outlier rejection, correlated noise, and selection bias. PBHs and other MACHOs are therefore ruled out as the dominant form of DM for objects associated to LIGO gravitational wave detections. Lastly, these bounds constrain early-Universe models that predict stellar-mass PBH production and strengthen the case for lighter forms of DM, including new elementary particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the Quark Orbital Angular Momentum at Electron-Ion Colliders Using Exclusive π 0 Production

We propose to detect signals from quark orbital angular momentum (OAM) through exclusive π 0 production in electron- (longitudinally polarized) proton collisions. Our analysis demonstrates that the sin 2 ϕ azimuthal angular correlation between the transverse momentum of the scattered electron and the recoil proton serves as a sensitive probe of quark OAM. Additionally, we present a numerical estimate of the asymmetry associated with this correlation for the kinematics accessible at the Electron-Ion Colliders in the U.S. and China. This study aims to pave the way for the first experimental study of quark OAM in relation to the Jaffe-Manohar spin sum rule. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Evidence of Radiation Reaction in the Collision of a High-Intensity Laser Pulse with a Laser-Wakefield Accelerated Electron Beam

The dynamics of energetic particles in strong electromagnetic fields can be heavily influenced by the energy loss arising from the emission of radiation during acceleration, known as radiation reaction. When interacting with a high-energy electron beam, today’s lasers are sufficiently intense to explore the transition between the classical and quantum radiation reaction regimes. We present evidence of radiation reaction in the collision of an ultrarelativistic electron beam generated by laser-wakefield acceleration ( ϵ > 500 MeV ) with an intense laser pulse (a 0 > 10). We measure an energy loss in the postcollision electron spectrum that is correlated with the detected signal of hard photons (γ rays), consistent with a quantum description of radiation reaction. The generated γ rays have the highest energies yet reported from an all-optical inverse Compton scattering scheme, with critical energy ϵ crit > 30 MeV.

43 PARTICLE ACCELERATORS↗

Graviton mass bounds

Recently, aLIGO announced the first direct detections of gravitational waves, a direct manifestation of the propagating degrees of freedom of gravity. The detected signals GW150914 and GW151226 have been used to examine the basic properties of these gravitational degrees of freedom, particularly setting an upper bound on their mass. It is timely to review what the mass of these gravitational degrees of freedom means from the theoretical point of view, particularly taking into account the recent developments in constructing consistent massive gravity theories. Apart from the GW150914 mass bound, a few other observational bounds have been established from the effects of the Yukawa potential, modified dispersion relation, and fifth force that are all induced when the fundamental gravitational degrees of freedom are massive. These different mass bounds are reviewed, how they stand in the wake of recent theoretical developments and how they compare to the bound from GW150914 are examined.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray nanoprobes and diffraction-limited storage rings: opportunities and challenges of fluorescence tomography of biological specimens

X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer.

de Jonge, Martin D.↗

Simulations of radiation damage as a function of the temporal pulse profile in femtosecond X-ray protein crystallography

Serial femtosecond X-ray crystallography of protein nanocrystals using ultrashort and intense pulses from an X-ray free-electron laser has proved to be a successful method for structural determination. However, due to significant variations in diffraction pattern quality from pulse to pulse only a fraction of the collected frames can be used. Experimentally, the X-ray temporal pulse profile is not known and can vary with every shot. This simulation study describes how the pulse shape affects the damage dynamics, which ultimately affects the biological interpretation of electron density. The instantaneously detected signal varies during the pulse exposure due to the pulse properties, as well as the structural and electronic changes in the sample. Here ionization and atomic motion are simulated using a radiation transfer plasma code. Pulses with parameters typical for X-ray free-electron lasers are considered: pulse energies ranging from 10 4 to 10 7 J cm -2 with photon energies from 2 to 12 keV, up to 100 fs long. Radiation damage in the form of sample heating that will lead to a loss of crystalline periodicity and changes in scattering factor due to electronic reconfigurations of ionized atoms are considered here. The simulations show differences in the dynamics of the radiation damage processes for different temporal pulse profiles and intensities, where ionization or atomic motion could be predominant. Overall, the different dynamics influence the recorded diffracted signal in any given resolution and will affect the subsequent structure determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Voltage CMOS Active Pixel Sensor

The high-voltage CMOS (HVCMOS) sensors are a novel type of CMOS active pixel sensors for ionizing particles that can be implemented in CMOS processes with deep n-well option. The pixel contains one sensor electrode formed with a deep n-well implanted in a p-type substrate. CMOS pixel electronics, embedded in shallow wells, are placed inside the deep n-well. By biasing the substrate with a high negative voltage and by the use of a lowly doped substrate, a depleted region depth of at least 30 µm can be achieved. The electrons generated by a particle are collected by drift, which induces fast detectable signals. This publication presents a 4.2-cm 2 large HVCMOS pixel sensor implemented in a commercial 180-nm process on a lowly doped substrate and its characterization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Carrier Trapping in SiNx Towards Ion Migration Measurements

Sodium ion migration has been implicated in potential induced degradation of the shunting type. The kinetics of sodium migration in silicon nitride can be investigated using a simple capacitance-voltage characterization technique. However, we show that the charge trapping strongly affects the measurement and must be taken into consideration in the experimental approach. Furthermore, we perform a systematic analysis of charge carrier trapping in silicon nitride, allowing us to correct trapping effects that otherwise prevent sodium signal detection. We extract trapping and detrapping time constants both on the order of several hours. This shows that trapping cannot be ignored as it occurs relatively quickly and is constantly evolving in time. Accurate determination of sodium behavior in dielectric layers will facilitate robust co-optimization of these layers for optical, passivation, and barrier properties.

42 ENGINEERING↗

Neutron Response of the EJ-254 Boron-Loaded Plastic Scintillator

Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5 loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron response, the proton light yield of EJ-254 was measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the EJ-254 proton light yield was obtained over the energy range of approximately 270 keV to 4.5 MeV and determined to be in agreement with other plastic scintillators comprised of the same polymer base. To isolate the slow neutron response, an AmBe source with polyethylene moderator was made incident on the EJ-254 scintillator surrounded by an array of EJ-309 observation detectors. Events in the EJ-254 target coincident with the signature 477.6 keV γ ray (resulting from de-excitation of the residual 7Li nucleus following boron neutron capture) were identified. Pulse shape discrimination was used to evaluate the temporal differences in the response of EJ-254 scintillation signals arising from γ-ray and fast/slow neutron interactions. Clear separation between γ-ray and fast neutrons signals was not achieved and the neutron capture feature was observed to overlap both the γ-ray and fast neutron bands. Taking into account the electron light nonproportionality, the neutron capture light yield in EJ-254 was determined to be 89.4±1.1 keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The VMM3a ASIC

The VMM3a is a custom low-noise Application Specific Integrated Circuit. It is intended to be used in the front end readout electronics of both the Micromegas and sTGC detectors of the ATLAS New Small Wheels upgrade project at CERN. It is fabricated in the 130 nm GlobalFoundries 8RF-DM process. Here, the 64 channels with highly configurable parameters, although designed for a specific project, can meet the processing needs of signals from various detector types in several other applications. In this note, the VMM3a, which is the production version of the VMM family, will be presented along with the features incorporated and its performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards patterned bioelectronics: facilitated immobilization of exoelectrogenic Escherichia coli with heterologous pili

Summary Biosensors detect signals using biological sensing components such as redox enzymes and biological cells. Although cellular versatility can be beneficial for different applications, limited stability and efficiency in signal transduction at electrode surfaces represent a challenge. Recent studies have shown that the Mtr electron conduit from Shewanella oneidensis MR ‐1 can be produced in Escherichia coli to generate an exoelectrogenic model system with well‐characterized genetic tools. However, means to specifically immobilize this organism at solid substrates as electroactive biofilms have not been tested previously. Here, we show that mannose‐binding Fim pili can be produced in exoelectrogenic E. coli and can be used to selectively attach cells to a mannose‐coated material. Importantly, cells expressing fim genes retained current production by the heterologous Mtr electron conduit. Our results demonstrate the versatility of the exoelectrogenic E. coli system and motivate future work that aims to produce patterned biofilms for bioelectronic devices that can respond to various biochemical signals.

59 BASIC BIOLOGICAL SCIENCES↗

Signatures of Selection for Resistance/Tolerance to Perkinsus olseni in Grooved Carpet Shell Clam ( Ruditapes decussatus ) Using a Population Genomics Approach

ABSTRACT The grooved carpet shell clam ( Ruditapes decussatus ) is a bivalve of high commercial value distributed throughout the European coast. Its production has suffered a decline caused by different factors, especially by the parasite Perkinsus olsenii . Improving production of R . decussatus requires genomic resources to ascertain the genetic factors underlying resistance/tolerance to P. olseni i . In this study, the first reference genome of R . decussatus was assembled through long‐ and short‐read sequencing (1677 contigs; 1.386 Mb) and further scaffolded at chromosome level with Hi‐C (19 superscaffolds; 95.4% of assembly). Repetitive elements were identified (32%) and masked for annotation of 38,276 coding‐ and 13,056 non‐coding genes. This genome was used as a reference to develop a 2bRAD‐Seq 13,438 SNP panel for a genomic screening on six shellfish beds distributed across the Atlantic Ocean and Mediterranean Sea. Beds were selected by perkinsosis prevalence and the infection level was individually evaluated in all the samples. Genetic diversity was significantly higher in the Mediterranean than in the Atlantic region. The main genetic breakage was detected between those regions (F ST = 0.224), being the Mediterranean more heterogeneous than the Atlantic. Several loci under divergent selection (394 outliers; 261 genomic windows) were detected across shellfish beds. Samples were also inspected to detect signals of selection for resistance/tolerance to P. olseni i by using infection‐level and population‐genomics approaches, and 90 common divergent outliers for resistance/tolerance to perkinsosis were identified and used for gene mining. Candidate genes and markers identified provide invaluable information for controlling perkinsosis and for improving production of the grooved carpet shell clam.

Sambade, Inés M. [Department of Zoology, Genetics ↗

Scatter correction for cone-beam CT in radiation therapy

Cone-beam CT (CBCT) is being increasingly used in modern radiation therapy for patient setup and adaptive replanning. However, due to the large volume of x-ray illumination, scatter becomes a rather serious problem and is considered as one of the fundamental limitations of CBCT image quality. Many scatter correction algorithms have been proposed in literature, while a standard practical solution still remains elusive. In radiation therapy, the same patient is scanned repetitively during a course of treatment, a natural question to ask is whether one can obtain the scatter distribution on the first day of treatment and then use the data for scatter correction in the subsequent scans on different days. To realize this scatter removal scheme, two technical pieces must be in place: (i) A strategy to obtain the scatter distribution in on-board CBCT imaging and (ii) a method to spatially match a prior scatter distribution with the on-treatment CBCT projection data for scatter subtraction. In this work, simple solutions to the two problems are provided. A partially blocked CBCT is used to extract the scatter distribution. The x-ray beam blocker has a strip pattern, such that partial volume can still be accurately reconstructed and the whole-field scatter distribution can be estimated from the detected signals in the shadow regions using interpolation/extrapolation. In the subsequent scans, the patient transformation is determined using a rigid registration of the conventional CBCT and the prior partial CBCT. From the derived patient transformation, the measured scatter is then modified to adapt the new on-treatment patient geometry for scatter correction. The proposed method is evaluated using physical experiments on a clinical CBCT system. On the Catphan(c)600 phantom, the errors in Hounsfield unit (HU) in the selected regions of interest are reduced from about 350 to below 50 HU; on an anthropomorphic phantom, the error is reduced from 15.7% to 5.4%. The proposed method is attractive in applications where a high CBCT image quality is critical, for example, dose calculation in adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct measurement of instantaneous source speed for a HDR brachytherapy unit using an optical fiber based detector

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a {sup 192}Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the {sup 192}Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the {sup 192}Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0{+-}1.0 and 17.3{+-}1.2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of |a|=113 cm/s{sup 2}. In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors' knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Objective assessment of image quality and dose reduction in CT iterative reconstruction

Purpose: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. Methods: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. Results: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. Conclusions: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality.

60 APPLIED LIFE SCIENCES↗