Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage Capabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Including operational aspects in the planning of power systems with large amounts of variable generation: A review of modeling approaches

In the past, power system planning was based on meeting the load duration curve at minimum cost. The increasing share of variable generation (VG) makes operational constraints more important in the planning problem, and there is more and more interest in considering aspects such as sufficient ramping capability, sufficient reserve procurement, power system stability, storage behavior, and the integration of other energy sectors often through demand response assets. In VG integration studies, several methods have been applied to combine the planning and operational timescales. We present a four-level categorization for the modeling methods, in order of increasing complexity: (1a) investment model only, (1b) operational model only, (2) unidirectionally soft-linked investment and operational models, (3a) bidirectionally soft-linked investment and operational models, (3b) operational model with an investment update algorithm, and (4) co-optimization of investments and operation. The review shows that using a low temporal resolution or only few representative days will not suffice in order to determine the optimal generation portfolio. In addition, considering operational effects proves to be important in order to get a more optimal generation portfolio and more realistic estimations of system costs. However, operational details appear to be less significant than the temporal representation. Furthermore, the benefits and impacts of more advanced modeling techniques on the resulting generation capacity mix significantly depend on the system properties. Thus, the choice of the model should depend on the purpose of the study as well as on system characteristics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ldlms_plugins_llnl

ldlms_plugins_llnl contains LLNL-developed plugins for LDMS (Lightweight Distributed Metric Service), which is software for low overhead monitoring, transport and storage of cluster metric data. These plugins add to LDMS the capability to monitor Lustre file system clients, metadata servers, and object storage servers.

Morrone, ChristopherJ↗

Integrated CCS for Kansas (ICKan) (Final Technical Report)

The goal of the Phase I activity under CarbonSAFE was to evaluate and develop a plan and strategy to address the challenges and opportunities for commercial-scale Carbon Capture and Storage (CCS) in Kansas, ICKan (Integrated CCS for Kansas). The objectives of this project included identifying and addressing the major technical and nontechnical challenges of implementing CO 2 capture and transport and establishing secure geologic storage for CO 2 in Kansas capable of storing 50Mt. In order to achieve these objectives, it was necessary to establish CCS Coordination Team that consisted of professionals from multiple technical and nontechnical disciplines such as geoscience, policy and law, public relations, engineering and others. The Team conducted an integrated and multi-disciplinary assessment of CCS in Kansas. The assessment included: (1) high-level technical, sub-basinal evaluations of CO 2 storage; (2) high-level technical examination of three of Kansas' largest CO 2 point sources and considered other alternatives; (3) high-level evaluation of transportation systems required, 4) evaluation of energy, environmental, regulatory, business law, and public policy; (5) public outreach and acceptance; and (6) identification of economic, commercial, and financial challenges for deployment of commercial-scale CCS in Kansas.

02 PETROLEUM↗

Standardized Testing Program for Solid-State Hydrogen Storage Technologies

In the US and abroad, major research and development initiatives toward establishing a hydrogen-based transportation infrastructure have been undertaken, encompassing key technological challenges in hydrogen production and delivery, fuel cells, and hydrogen storage. However, the principal obstacle to the implementation of a safe, low-pressure hydrogen fueling system for fuel-cell powered vehicles remains storage under conditions of near-ambient temperature and moderate pressure. The choices for viable hydrogen storage systems at the present time are limited to compressed gas storage tanks, cryogenic liquid hydrogen storage tanks, chemical hydrogen storage, and hydrogen absorbed or adsorbed in a solid-state material (a.k.a. solid-state storage). Solid-state hydrogen storage may offer overriding benefits in terms of storage capacity, kinetics and, most importantly, safety. The fervor among the research community to develop novel storage materials had, in many instances, the unfortunate consequence of making erroneous, if not wild, claims on the reported storage capacities achievable in such materials, to the extent that the potential viability of emerging materials was difficult to assess. This problem led to a widespread need to establish a capability to accurately and independently assess the storage behavior of a wide array of different classes of solid-state storage materials, employing qualified methods, thus allowing development efforts to focus on those materials that showed the most promise. However, standard guidelines, dedicated facilities, or certification programs specifically aimed at testing and assessing the performance, safety, and life cycle of these emergent materials had not been established. To address the stated need, the Testing Laboratory for Solid-State Hydrogen Storage Technologies was commissioned as a national-level focal point for evaluating new materials emerging from the designated Materials Centers of Excellence (MCoE) according to established and qualified standards. Working with industry, academia, and the U.S. government, SwRI set out to develop an accepted set of evaluation standards and analytical methodologies. Critical measurements of hydrogen sorption properties in the Laboratory have been based on three analytical capabilities: 1) a high-pressure Sievert-type volumetric analyzer, modified to improve low-temperature isothermal analyses of physisorption materials and permit in situ mass spectroscopic analysis of the sample’s gas space; 2) a static, high-pressure thermogravimetric analyzer employing an advanced magnetic suspension electro-balance, glove-box containment, and capillary interface for in situ mass spectroscopic analysis of the sample’s gas space; and 3) a Laser-induced Thermal Desorption Mass Spectrometer (LTDMS) system for high thermal-resolution desorption and mechanistic analyses. The Laboratory has played an important role in down-selecting materials and systems that have emerged from the MCoEs.

08 HYDROGEN↗

Lunar Mega Project: Processes, Work Flow and Terminology of the Terrestrial Construction Industry versus the Space Industry

Recent developments around the world show an increased interest and international activity toward developing a lunar surface human and robotic presence with a long term, sustainable vision. In Europe, the construction of a "Moon Village" has been proposed, and China has stated its intention to build a research station with a crew at the lunar South Pole. Russia stated it will land cosmonauts on the Moon in the 2030's. India has sent an orbiter, a robotic lander, and rover to the Moon. The USA intends to land the first woman and a man on the Moon by 2024 to initiate a sustained human lunar presence.A lunar research station with associated commercial activities will require infrastructure to become a permanent capability. Landing and launch pads, propellant storage and distribution farms, spacecraft access and handling structures, cranes, blast protection berms or walls, roads, graded areas, dust stabilized areas, foundations, parking lots, radiation shelters, micro-meteorite protection hangars, habitats and other human shelters, greenhouse farms, utility trenches, power plants, industrial water and oxygen extraction plants, communications antenna towers, thermal protection, mining zones, crater access and sub-surface access will be required to create a safe and sustainable lunar operations capability. This infrastructure will require significant construction activities in an extreme environment, with risky and expensive operations. On Earth, there are similar large and expensive projects (>$1 Billion) in difficult locations that attract a lot of public attention. These are known as "Mega Projects" and examples include bridges, tunnels, highways, railways, airports, seaports, power plants, dams, wastewater projects, Special Economic Zones (SEZ), oil and natural gas extraction projects, public buildings, information technology systems, aerospace projects, and weapons systems. Large consortiums consisting of public and private entities typically implement these infrastructure Mega-Projects.This paper will compare the typical design process, project management process, and work flow in the terrestrial construction industry to the space industry in order to create a better understanding between the terrestrial construction industry and the space industry, to further enable collaboration on a lunar Mega Project to build infrastructure on the Moon. In addition, a glossary of respective industry terminology with annotated linkages and definitions has been compiled. This information will enable contracts and business practices to be formulated for generating requests for proposals (RFP) by governments to consortiums consisting of construction and space industry companies that will bid on Lunar Infrastructure Projects that could lead to contracts to build the permanent capabilities.

Robert P Mueller↗

A Modular Heat Engine for the Direct Conversion of Natural Gas to Hydrogen and Power using Hydrogen Turbines (Phase I Final Report)

This report describes a novel, modular heat engine comprising of a one-step hydrogen production from natural gas with in-situ CO 2 separation which is amenable for re-use or sequestration. Combining with a hydrogen turbine subsystem, a distributed or central power generation system is conceived. An added hydrogen storage subsystem enables load-following capability. The techno-economics of the overall system compared favorably against current state-of-the-art natural gas combined cycle plants with post-combustion CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗

Light storage, retrieval, and controllable interference in an atomic tripod system

Highly efficient quantum memories are essential for advancing quantum information processing technologies, including scalable quantum computing and quantum networks. We experimentally demonstrate a light storage and retrieval protocol in a tripod system using an ensemble of laser-cooled 87 Rb atoms. The tripod system, which consists of three ground states and an excited state, offers rich dynamics: its use to coherently store and retrieve a weak probe pulse in the 87 Rb 𝐹 = 1 ground-state manifold leads to the interference of two spin-wave excitations during storage time that translate to an interference in the peak intensity of the retrieved probe pulse. Our work shows that these interferences, which manifest when varying the pulse sequence or energy level structure, can be controlled experimentally by varying the storage time, optical phase, and magnetic field strength. Theoretical simulations exhibit excellent agreement with the experimental results. In conclusion, this work demonstrates the rich dynamics and versatile capabilities of atomic tripod systems for light storage and retrieval, with key advantages over conventional Λ systems, highlighting the potential of atomic tripod systems for applications in quantum information processing, quantum synchronization, and atomic memory protocols.

Coherent control↗

An emulator for minimizing finite element analysis implementation resources

A finite element analysis emulator providing a basis for efficiently establishing an optimum computer implementation strategy when many calculations are involved is described. The SCOPE emulator determines computer resources required as a function of the structural model, structural load-deflection equation characteristics, the storage allocation plan, and computer hardware capabilities. Thereby, it provides data for trading analysis implementation options to arrive at a best strategy. The models contained in SCOPE lead to micro-operation computer counts of each finite element operation as well as overall computer resource cost estimates. Application of SCOPE to the Memphis-Arkansas bridge analysis provides measures of the accuracy of resource assessments. Data indicate that predictions are within 17.3 percent for calculation times and within 3.2 percent for peripheral storage resources for the ELAS code.

Melosh, R. J.↗

Enabling Principles for Dual Participation by Energy Storage as a Transmission and Market Asset

Because the electric transmission system is sized to meet the highest levels of customer demand, much of its designed capacity goes unused during average operating conditions. As a uniquely flexible and scalable asset capable of providing multiple grid services, energy storage can be deployed to support the transmission system and then also provide services to energy markets when not needed for transmission. This paper reviews the technical barriers in transmission planning practices and energy market design that prevent the realization of dual-use energy storage projects that provide both regulated transmission and competitive market services. Current practices create barriers against the identification of energy storage in the transmission planning process and against the participation of a regulated transmission asset in competitive energy markets. A review of regional transmission plans identifies best practices for including energy storage in the planning process by directing planners to proactively identify such projects or by providing clear mechanisms for stakeholders to propose them. Creating a market participation model for dual-use energy storage assets requires establishing when an asset will be allowed to participate in the market, how it will participate in the market, and where it will recover its costs. In answering these questions, key principles must be satisfied, such as prioritizing reliability, incrementally building on existing market design, and balancing competing objectives. Several policy options exist for satisfying those principles, giving grid operators and stakeholders significant flexibility in developing a dual-use participation model in accordance with regional policies and conditions. By objectively framing the issue and identifying policy options, this paper may inform subsequent proceedings on dual-use energy storage and be a resource to regional market operators, utilities, developers, regulators, policymakers, and other stakeholders as they collectively work on this complex issue.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Going beyond reliability to achieve robustness

Reliability is the ability to perform well and consistently. More formally, reliability is defined as the mathematical probability that a system does not fail during a specified time period under its specified operating conditions. The specified operating conditions often go beyond the nominal environment to include variations and challenges encountered in operational use. The difficulty is that systems are often operated outside of their specified operating conditions and, if they fail, the designers are in theory blameless. Unanticipated damaging events include internal failures, external disruptions in supporting systems, accidents, and repurposing. The most common explanation of a system failure is human error, which is usually the first assumption of the system designers. Robustness is the capability to perform without failure under a wide range of conditions that go beyond the specified operating conditions. The first step towards improving robustness would be to expand the system’s specified operating conditions to include a wider range of anticipated challenges, especially human error. Beyond this, there is a need for general approach to reduce the impact of unanticipated future events, the unknown unknowns, by improving the system’s general ability to cope. Robustness can be improved by providing additional processing capacity, larger flow control buffers, increased backup storage, more online redundancy, and more capable supervisory monitoring and control.

Harry W Jones↗

Quantum volume hologram

We propose a scheme for parallel spatially multimode quantum memory for light. The scheme is based on a counterpropagating quantum signal wave and a strong classical reference wave as in a classical volume hologram and therefore can be called a quantum volume hologram. The medium for the hologram consists of a spatially extended ensemble of atoms placed in a magnetic field. The write-in and readout of this quantum hologram is as simple as that of its classical counterpart and consists of a single-pass illumination. In addition, we show that the present scheme for a quantum hologram is less sensitive to diffraction and therefore is capable of achieving a higher density of storage of spatial modes as compared to previous proposals. We present a feasibility study and show that experimental implementation is possible with available cold atomic samples. A quantum hologram capable of storing entangled images can become an important ingredient in quantum information processing and quantum imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vent System Analysis for the Cryogenic Propellant Storage Transfer Ground Test Article

To test and validate key capabilities and technologies required for future exploration elements such as large cryogenic propulsion stages and propellant depots, NASA is leading the efforts to develop and design the Cryogenic Propellant Storage and Transfer (CPST) Cryogenic Fluid Management (CFM) payload. The primary objectives of CPST payload are to demonstrate: 1) in-space storage of cryogenic propellants for long duration applications; and 2) in-space transfer of cryogenic propellants. The Ground Test Article (GTA) is a technology development version of the CPST payload. The GTA consists of flight-sized and flight-like storage and transfer tanks, liquid acquisition devices, transfer, and pressurization systems with all of the CPST functionality. The GTA is designed to perform integrated passive and active thermal storage and transfer performance testing with liquid hydrogen (LH2) in a vacuum environment. The GTA storage tank is designed to store liquid hydrogen and the transfer tank is designed to be 5% of the storage tank volume. The LH2 transfer subsystem is designed to transfer propellant from one tank to the other utilizing pressure or a pump. The LH2 vent subsystem is designed to prevent over-pressurization of the storage and transfer tanks. An in-house general-purpose computer program was utilized to model and simulate the vent subsystem operation. The modeling, analysis, and the results will be presented in the final paper.

Hedayat, A↗

Effect of Heat and Electricity Storage and Reliability on Microgrid Viability:A Study of Commercial Buildings in California and New York States

In past work, Berkeley Lab has developed the Distributed Energy Resources Customer Adoption Model (DER-CAM). Given end-use energy details for a facility, a description of its economic environment and a menu of available equipment, DER-CAM finds the optimal investment portfolio and its operating schedule which together minimize the cost of meeting site service, e.g., cooling, heating, requirements. Past studies have considered combined heat and power (CHP) technologies. Methods and software have been developed to solve this problem, finding optimal solutions which take simultaneity into account. This project aims to extend on those prior capabilities in two key dimensions. In this research storage technologies have been added as well as power quality and reliability (PQR) features that provide the ability to value the additional indirect reliability benefit derived from Consortium for Electricity Reliability Technology Solutions (CERTS) Microgrid capability. This project is intended to determine how attractive on-site generation becomes to a medium-sized commercial site if economical storage (both electrical and thermal), CHP opportunities, and PQR benefits are provided in addition to avoiding electricity purchases. On-site electrical storage, generators, and the ability to seamlessly connect and disconnect from utility service would provide the facility with ride-through capability for minor grid disturbances. Three building types in both California and New York are assumed to have a share of their sensitive electrical load separable. Providing enhanced service to this load fraction has an unknown value to the facility, which is estimated analytically. In summary, this project began with 3 major goals: (1) to conduct detailed analysis to find the optimal equipment combination for microgrids at a few promising commercial building hosts in the two favorable markets of California and New York; (2) to extend the analysis capability of DER-CAM to include both heat and electricity storage; and (3) to make an initial effort towards adding consideration of PQR into the capabilities of DER-CAM.

25 ENERGY STORAGE↗

Radiation-resistant metal-organic framework enables efficient separation of krypton fission gas from spent nuclear fuel

Capture and storage of volatile radionuclides that result from processing of used nuclear fuel is a major challenge. Solid adsorbents, in particular ultra-microporous metal-organic frameworks, could be effective in capturing these volatile radionuclides, including 85 Kr. However, metal-organic frameworks are found to have higher affinity for xenon than for krypton, and have comparable affinity for Kr and N 2 . Also, the adsorbent needs to have high radiation stability. To address these challenges, here we evaluate a series of ultra-microporous metal-organic frameworks, SIFSIX-3-M (M = Zn, Cu, Ni, Co, or Fe) for their capability in 85 Kr separation and storage using a two-bed breakthrough method. These materials were found to have higher Kr/N 2 selectivity than current benchmark materials, which leads to a notable decrease in the nuclear waste volume. The materials were systematically studied for gamma and beta irradiation stability, and SIFSIX-3-Cu is found to be the most radiation resistant.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring Carbon Storage Sites with Time-Lapse Gravity Surveys

Monitoring technologies are deployed on carbon storage sites to demonstrate that the injected CO2 is contained within the storage complex during and long after the active life of the project and that the CO2 behavior is conforming to expectations. Detection of gravity variations accompanying mass redistributions in the subsurface caused by fluid movements in reservoirs provides a unique means for monitoring the dynamics of a carbon sequestration site. Time-lapse gravity surveys have a long history of effectively monitoring temporal density changes in the subsurface. However, monitoring of carbon storage sites with time-lapse gravity surveys using surface or borehole measurements remains limited, although it gained more attention during the last decade. With the recent progresses in instrument capabilities, and the increased number of fluid storage sites (e.g., wastewater, CO2, natural gas, etc.), the gravity method (with its unique ability to remotely estimate both the mass of an injected fluid and its location) has a promising future in monitoring. This chapter provides background information regarding the gravity method and discusses its modeling and application to various carbon storage sites.

Carbon Sequestration, time-lapse gravity, monitori↗

Polar Bear™ – Innovative Capture of Storage Tank Vapors

Polar Bear™ is a patented technology developed by the Energy & Environmental Research Center (EERC) to capture storage tank vapors and eliminate methane emissions from upstream oil- and gas-producing facilities. Sparked by early commercial investment, the EERC licensed the technology and extended the intellectual property to storage tanks. Polar Bear™ is uniquely engineered and adapted to individual lower-producing facilities where there is otherwise no economic alternative for capturing tank vapors. A high number of small producing oil and gas wells are distributed across the country. The aggregate contributes to a significant volume of emissions. Because of the lack of economy of scale, gas volumes from these facilities are typically not recovered and contribute to methane emissions. Polar Bear™ provides a fit-for-purpose compression solution that addresses cost by reducing complexity with respect to conventional vapor recovery units and eliminating oil changes. Unique to Polar Bear™ is the capability to separate oxygenated gas from storage tank vapors. Storage tanks are designed to “breathe,” allowing gas to enter and escape during internal level and temperature changes. This infiltration of air into the tank headspace imparts undesirable oxygen content with respect to pipeline gathering. Polar Bear™ separates the vapor stream, allowing oxygen-rich gas to be used as fuel on-site while recovering the liquids-rich portion of the gas where oxygen content is minimized. A prototype system was tested to verify process models, evaluate operational performance, and advance the technology readiness level from 5 to 6. Results provide a good match between experimental measurements and process models, indicating the models are useful for future scale-up and field design. Various mixtures of nitrogen and liquefied petroleum gas were tested to understand the mass balance of nitrogen and how it relates to the potential control of oxygen content. Findings indicate that less than 2000 ppm of oxygen is likely to remain in the liquid portion of the gas in field applications. The research and development prepare the technology for field implementation to eliminate routine and fugitive methane emissions from storage tanks.

02 PETROLEUM↗

Validation of Lithium-ion cell technology for JPL's 2003 Mars Exploration Rover Mission

n early 2004 JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling >300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20 C to +40 C), withstanding long storage periods (e.g., cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the viability of Lithium-ion technology to meet these stringent requirements, a comprehensive test program was implemented aimed at demonstrating the performance capability of prototype cells fabricated by Lithion, Inc. (Yardney Technical Products, Inc.). The testing performed includes, determining the (a) room temperature cycle life, (b) pulse capability as a function of temperature, (e) self-discharge and storage characteristics mission profile capability, (f) cycle life under mission simulation conditions, (g) impedance characteristics, (h) impact of cell orientation, and (i) performance in 8-cell engineering batteries. As will be discussed, the Lithium-ion prototype cells and batteries were demonstrated to meet, as well as, exceed the requirements defined by the mission.

2003 Mars Exploration Rover (MER)↗

Solar Airplanes and Regenerative Fuel Cells

A solar electric aircraft with the potential to "fly forever" has captured NASA's interest, and the concept for such an aircraft was pursued under Aeronautics Environmental Research Aircraft and Sensor Technology (ERAST) project. Feasibility of this aircraft happens to depend on the successful development of solar power technologies critical to NASA's Exploration Initiatives; hence, there was widespread interest throughout NASA to bring these technologies to a flight demonstration. The most critical is an energy storage system to sustain mission power during night periods. For the solar airplane, whose flight capability is already limited by the diffuse nature of solar flux and subject to latitude and time of year constraints, the feasibility of long endurance flight depends on a storage density figure of merit better than 400-600 watt-hr per kilogram. This figure of merit is beyond the capability of present day storage technologies (other than nuclear) but may be achievable in the hydrogen-oxygen regenerative fuel cell (RFC). This potential has led NASA to undertake the practical development of a hydrogen-oxygen regenerative fuel cell, initially as solar energy storage for a high altitude UAV science platform but eventually to serve as the primary power source for NASAs lunar base and other planet surface installations. Potentially the highest storage capacity and lowest weight of any non-nuclear device, a flight-weight RFC aboard a solar-electric aircraft that is flown continuously through several successive day-night cycles will provide the most convincing demonstration that this technology's widespread potential has been realized. In 1998 NASA began development of a closed cycle hydrogen oxygen PEM RFC under the Aeronautics Environmental Research Aircraft and Sensor Technology (ERAST) project and continued its development, originally for a solar electric airplane flight, through FY2005 under the Low Emissions Alternative Power (LEAP) project. Construction of the closed loop system began in 2002 at the NASA Glenn Research Center in Cleveland, Ohio. System checkout was completed, and testing began, in July of 2003. The initial test sequences were done with only a fuel cell or electrolyzer in the test rig. Those tests were used to verify the test apparatus, procedures, and software. The first complete cycles of the fully closed loop, regenerative fuel cell system were successfully completed in the following September. Following some hardware upgrades to increase reactant recirculation flow, the test rig was operated at full power in December 2003 and again in January 2004. In March 2004 a newer generation of fuel cell and electrolyzer stacks was substituted for the original hardware and these stacks were successfully tested at full power under cyclic operation in June of 2004.

Bents, David J.↗