Search NASA⌕ Search

SEARCH · Search NASA

Results for “System reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

System Health and Status Reporting is Used to Improve Infrastructure Systems at the Hanford Site - 20449

Reliable physical infrastructure systems are vital to completing the clean-up mission and the start-up and commissioning of new nuclear waste processing facilities at the Hanford Site. Key infrastructure systems at Hanford include water, sewer, and electrical utilities, roads, telecommunications/network systems, and fire systems. All of the infrastructure systems are non-nuclear, General Service systems that are being maintained under formal engineering configuration control and none are specifically credited in any documented safety analysis (DSA). Starting in calendar year 2017, the Hanford Site's infrastructure and services contractor started producing system health and status reports for a total of 15 critical infrastructure systems as means to get a better understanding of each system's health and how it could be improved to ensure better and more reliable service delivery. As the reporting, tracking, and use of the metrics has matured, the number of systems for which reports are being developed has been expanded to a total of 23. Each of the critical infrastructure systems are assigned primary and alternate design authorities that complete qualifications on each assigned system. The design authorities actively manage and maintain configuration control on each of their systems and track metrics associated with availability, maintenance (corrective and preventive), and configuration of the technical baseline. The metrics are based on the principles established in Chapter V of DOE O 420.1C, Facility Safety, [1] and have been tailored as appropriate to each of the key infrastructure systems. An overall assessment of system health is performed and documented on a routine basis (e.g., quarterly). Included in this documentation is a quantitative score for each of the metrics (i.e., availability, maintenance, configuration management) along with results of system walk-downs, description of any permanent design modifications, identification of new or emerging issues and vulnerabilities affecting the system, and an assessment by the design authority of actions necessary to improve the system health score. The overall status scores are calculated using a formula and based on a pre-determined grading scale, a color is assigned for simple presentation. The information gained from developing the reports is being used to (1) assist with making timely and better informed decisions through the use of solid technical bases that are increasing the overall reliability and capabilities of the Site's infrastructure systems as new expense and capital projects in the Reliability Projects Investment Portfolio (RPIP) are prioritized and executed; (2) feed the risk management program, and (3) integrate the technical content of Master Plans that describe the Site's needs for the system and the system's capabilities to meet those future needs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE LIQUID NITROGEN SYSTEM FOR CHAMBER A; A CHANGE FROM ORIGINAL FORCED FLOW DESIGN TO A NATURAL FLOW (THERMO SIPHON) SYSTEM

NASA at the Johnson Space Center (JSC) in Houston is presently working toward modifying the original forced flow liquid nitrogen cooling system for the thermal shield in the space simulation chamber-A in Building 32 to work as a natural flow (thermo siphon) system. Chamber A is 19.8 m (65 ft) in diameter and 35.66 m (117 ft) high. The LN{sub 2} shroud environment within the chamber is approximately 17.4 m (57 ft) in diameter and 28 m (92 ft) high. The new thermo siphon system will improve the reliability, stability of the system. Also it will reduce the operating temperature and the liquid nitrogen use to operate the system. This paper will present the requirements for the various operating modes. System level thermodynamic comparisons of the existing system to the various options studied and the final option selected will be outlined. A thermal and hydraulic analysis to validate the selected option for the conversion of the current forced flow to natural flow design will be discussed. The proposed modifications to existing system to convert to natural circulation (thermo siphon) system and the design features to help improve the operations, and maintenance of the system will be presented.

42 ENGINEERING↗

Moore vs. Murphy: Tradeoffs between complexity and reliability in distributed energy system scheduling using software-as-a-service

Software-based optimization of building control strategies, including scheduling, has the potential to improve the performance of existing complex heating, ventilation, and air conditioning (HVAC), storage, and other systems—especially if temporally variable energy production, such as solar thermal or photovoltaics, is included. If reductions in energy bills can be achieved using optimized control strategies that take advantage of cost-saving opportunities, such as time-of-use pricing, the additional bill savings can cover further efficiency investment costs. As computer processing becomes cheaper over time (Moore's Law), opportunities to perform complex control optimization become more abundant, and these can be performed remotely as software-as-a-service (SaaS). However, by “perfecting” our control strategies, we run an increased risk that when something unexpected happens (Murphy's Law), the consequences of failure are greater. This study used simulation to explore the potential benefits of HVAC schedule optimization, delivery, and implementation using a SaaS paradigm, at various levels of complexity. Implementing optimal schedules in a model of an efficient building's HVAC system, the study predicts energy cost savings of up to 10% compared to the naïve reference control strategy. Optimizing more system control variables increases the potential energy cost savings; however, these savings could be compromised by failures in communication inherent in delivering schedules via SaaS. The additional cost of energy resulting from the risk of increased demand charges generally increased with increased communication failure to a much larger extent than the risk of increased energy use charges. This work suggests that moderate improvements in performance, achieved at low cost by simple means, may be more effective than highly optimized schemes, which are more susceptible to failure due to their dependence on complex interactions between systems.

42 ENGINEERING↗

Maintaining Balance: The Increasing Role of Energy Storage for Renewable Integration

For nearly a century, global power systems have focused on three key functions: generating, transmitting, and distributing electricity as a real-time commodity. Physics requires that electricity generation always be in real-time balance with load-despite variability in load on time scales ranging from subsecond disturbances to multiyear trends. With the increasing role of variable generation from wind and solar, the retirement of fossil-fuel-based generation, and a changing consumer demand profile, grid operators are using new methods to maintain this balance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward Highly Secure and Autonomic Computing Systems: A Hierarchical Approach

The overall objective of this research project is to develop novel architectural techniques as well as system software to achieve a highly secure and intrusion-tolerant computing system. Such system will be autonomous, self-adapting, introspective, with self-healing capability under the circumstances of improper operations, abnormal workloads, and malicious attacks. The scope of this research includes: (1) System-wide, unified introspection techniques for autonomic systems, (2) Secure information-flow microarchitecture, (3) Memory-centric security architecture, (4) Authentication control and its implication to security, (5) Digital right management, (5) Microarchitectural denial-of-service attacks on shared resources. During the period of the project, we developed several architectural techniques and system software for achieving a robust, secure, and reliable computing system toward our goal.

97 MATHEMATICS AND COMPUTING↗

System Study: Emergency Power System 1998–2018

This report presents an unreliability evaluation of the emergency power system (EPS) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the EPS results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Performance SOFCs with a Superior Stability for Reliable and Durable Power Systems

Next generation of fuel cells, electrolyzers, and batteries requires higher power, faster kinetics, and larger energy density, which necessitate the use of compositionally complex oxides to achieve multifunctionalities and activity. These compositionally complex oxides may change their phases and structures during an electrochemical process – a so-called “electrochemically driven phase transformation”. The origin for such a phase change has remained obscure. More importantly, there is a need to develop high performance solid oxide fuel cells with an enhanced stability. In this work, the La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 (LSCF) cathode surface is modified by infiltration of Pr 6 O 11 and the power density at 0.8V and 750 °C is improved by 21%. In addition, by replacing the traditional barrier layer Gd 0.2 Ce 0.8 O 1.9 with mixed conducting Pr 0.1 Gd 0.1 Ce 0.8 O 1.9 , the power density increases by 38%. The different mechanism of promotions was investigated by electrochemical impedance spectroscopy. The ohmic resistance is dramatically reduced by applying the PGCO interlayer, and the distribution of relaxation time was used to analyze the mechanism for which the polarization resistance was decreased attributing to the mixed conduction nature in PrO x . An increase of power density at 0.8 V of 0.358 W/cm 2 (71%) is achieved with the implementation of both surface modification and buffer layer engineering. An experimental study and a theoretical analysis were then carried out on phase evolution in praseodymium nickelates. Nickelate-based electrodes show up to 60× greater phase transformation during operation when compared to thermally annealed ones. Theoretical analysis suggests that the presence of a reduced oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is the origin for the phase change in an oxygen electrode. Guided by the theory, an addition of the electronic conduction in the interface layer leads to the significant suppression of phase change, while improving cell performance and performance stability. When an oxygen electrode is under polarization, the oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is lower than that of incoming oxidant. Under a high polarization, the environment at the aforementioned interface may lead to phase transformation of the oxygen electrode. The local oxygen partial pressure is determined by the transport properties at the interfaces. An addition of the electronic conduction in the interface layer, for instance using (Pr,Gd)-doped ceria to replace Gd-doped ceria, results in improved cell performance and performance stability, while the phase transformation is significantly suppressed. This work provides a fundamental understanding of the origin for phase transformation in oxygen electrodes during operation and use this knowledge to develop a high-performance electrode that exhibits improved performance stability.

30 DIRECT ENERGY CONVERSION↗

Mississippi's Strategic Resilience: A multi-systems approach to secure, reliable, and adaptable electric grid infrastructure

Mississippi’s electric grid resilience challenges are linked to an intersection of complex socioeconomic, ecological, technological, historical, and political challenges, exacerbated by increasing severe weather like flooding and tornado events. The state’s legacy of underinvestment in critical energy infrastructure, particularly in rural areas and vulnerable floodplains, have stressed an aging grid, creating long-lasting disruptions in electric service during weather-related outages. Effective emergency management and preparedness is further hampered by a lack of coordination across local, county, and regional scales. Using the TASTI-GRID platform and partnership with Oak Ridge National Laboratory (ORNL), Mississippi is developing a comprehensive regional resilience strategy to overcome energy security and reliability challenges, mitigating the impacts of natural hazards, and positioning Mississippi as a resilient and premier destination for residents, businesses, and economic development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical analysis of cascading failures in power grids

We introduce a new microscopic model of cascading failures in transmission power grids. This model accounts for automatic response of the grid to load fluctuations that take place on the scale of minutes, when optimum power flow adjustments and load shedding controls are unavailable. We describe extreme events, caused by load fluctuations, which cause cascading failures of loads, generators and lines. Our model is quasi-static in the causal, discrete time and sequential resolution of individual failures. The model, in its simplest realization based on the Directed Current description of the power flow problem, is tested on three standard IEEE systems consisting of 30, 39 and 118 buses. Our statistical analysis suggests a straightforward classification of cascading and islanding phases in terms of the ratios between average number of removed loads, generators and links. The analysis also demonstrates sensitivity to variations in line capacities. Future research challenges in modeling and control of cascading outages over real-world power networks are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗