Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Thermal Modeling and Correlation of the Space Environments Complex Vacuum Chamber and Cryoshroud

From Presentation: Formerly known as the Space Power Facility (SPF) Located at Plum Brook Station in Sandusky, OH -- Houses large-scale test facilities including the Space Simulation Vacuum Chamber -- Largest vacuum chamber in the world -- 100 ft diameter, 122 ft tall -- Cryoshroud operates between -250 °F and +140 °F -- To be used for Orion EM-1 thermal vacuum test -- Thermal Desktop model of vacuum chamber, cryoshroud, mechanical ground support equipment (MGSE) including fluid model of GN2 -- Primary uses: Predict MGSE temperatures; Predict heat load on GN2 system -- Includes 96 TD Temperature Measures that represent test thermocouples -- Steady state correlation with 3 tests: 2 hot; 1 cold -- Two ISTs performed with no MGSE inside the cryoshroud: Insulated test: operated at 170 °F for 37 hours; Uninsulated test: operated at 170 °F for 14 days -- Only cryoshroud thermocouples were installed

Thermal modeling↗

MEDLI2 Flight Heat Flux Sensor Environment and Planetary Protection Testing

Mars 2020 will fly the Mars Entry, Descent, and Landing Instrumentation II (MEDLI2) sensor suite consisting of a total of seventeen instrumented thermocouple sensor plugs, eight pressure transducers, two total heat flux sensors, and one radiometer embedded in the thermal protection system (TPS). Of the MEDLI2 instrumentation, eleven instrumented thermocouple plugs and seven pressure transducers will be installed on the heatshield of the Mars 2020 vehicle while the rest will be installed on the backshell. The goal of the MEDLI2 instrumentation is to directly inform the large performance uncertainties that contribute to the design and validation of a Mars entry system. A better understanding of the entry environment and TPS performance could lead to reduced design margins enabling greater payload mass-fraction and smaller landing ellipses. The MEDLI2 total heat flux sensors and radiometer are new instruments that were not flown on the Mars Science Laboratory mission. These sensors directly measure the surface heat flux and radiation at specific backshell locations. The total heat flux sensors use a Schmidt-Boelter sensing element. The radiometer version uses a sapphire window placed over the Schmidt-Boelter sensing element to separate the radiative component of the total heat flux. MEDLI2 recently planned and executed protoflight environmental testing as well planetary protection measures on the flight and flight-spare total heat flux sensors and radiometers. This testing is required to provide confidence in the performance of the flight-lot sensors when exposed to flight-like environments, and to reduce the risk of biological contamination on the planet of Mars with microbes from Earth.

MEDLI2 FLIGHT HEAT FLUX SENSOR ENVIRONMENT AND PLA↗

Reconstruction of Schiaparelli and Comars Flight Data

ESA recently flew an entry, descent, and landing demonstrator module called Schiaparelli that entered the atmosphere of Mars on the 19th of October, 2016. The instrumentation suite included heatshield and backshell pressure transducers and thermocouples (known as AMELIA) and backshell radiation and direct heatflux-sensing sensors (known as COMARS and ICOTOM). Due to the failed landing of Schiaparelli, only a subset of the flight data was transmitted before and after plasma black-out. The goal of this paper is to present comparisons of the flight data with calculations from NASA simulation tools, DPLR/NEQAIR and LAURA/HARA. DPLR and LAURA are used to calculate the flowfield around the vehicle and surface properties, such as pressure and convective heating. The flowfield data are passed to NEQAIR and HARA to calculate the radiative heat flux. Comparisons will be made to the COMARS total heat flux, radiative heat flux and pressure measurements. Results will also be shown against the reconstructed heat flux which was calculated from an inverse analysis of the AMELIA thermocouple data performed by Astrium. Preliminary calculations are presented in this abstract. The aerodynamics of the vehicle and certain as yet unexplained features of the inverse analysis and forebody data will be investigated.

Schiaparelli↗

Thermal History Mapping Technology for Turbine Engine Diagnostics

The infusion of ceramic matrix composites (CMCs) in next generation gas turbines represents daunting challenges as the failure of protective coating, known as Environmental Barrier Coating (EBC), means little remnant life of CMC components. Consequently reliable lifing is critical to the success of CMC components. Accurate thermal mapping of EBC in rig and engine test is of paramount importance because temperature is the most critical variable for EBC life. Current temperature measurement technologies include thermocouples, pyrometers, IR cameras, and thermal paints. Thermocouples require a passage to access the components and pyrometers and IR cameras require line-of-sight. Thermal paints are based on color-sensitive pigments that visually indicate the temperature that a component experienced. Thermal paints do not require line-of-sight, however, they have a low resolution and a limited temperature capability (~1400°C). Thermal history coating is based on oxide ceramic which luminesces when excited with a light source. The luminescence changes when the material's structure changes triggered by heat impact. The maximum temperature to which the material was exposed can be determined from the luminescence change. This paper describes the principles of this new technique and demonstrates its capabilities for EBCs exposed to excess of 1500°C.

Lee, Kang N.↗

Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems

The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.

Sensitivity Analysis↗

Evaluation of Temperature Gradients During Cure of a Thick Carbon Fiber/Epoxy Composite

The purpose of this study is to evaluate the development of thermal gradients throughout thick (1") carbon fiber composites and determine the effect of internal temperature distribution during cure on the observed mechanical properties in those composites. Composites up to 1.5" thick (56 plies) were fabricated with T700S/TC380 braided prepreg from Tencate following a modified vacuum bag layup procedure to include embedded thermocouples within the plies of the composite. Composite panels were cured in a programmable oven with thermocouple reading embedded throughout the panel thickness. Maximum temperature gradients measured between regions of the composite did not exceed 10 degrees C for any given composite thickness. The most significant temperature variation was measured between the mid-thickness plies and the tool-side surface plies. Although through thickness temperature variation during cure was small, a measureable variation in coupon glass transition temperature was recorded between the tool side plies and the remainder of the part, prior to post cure. Thermal and mechanical behavior of coupons taken from segments through the thickness of the part were comparable following a post-cure cycle.

Miller, Sandi↗

Revisiting MEDLI with Improved Modeling and Simulation Tools

The thermal protection system (TPS) of the Mars 2020 capsule will carry a suite of sensors called MEDLI2 (Mars Entry, Descent, and Landing Instrument 2). This suite consists of pressure sensors/transducers and thermocouple plugs meant to measure atmospheric properties, vehicle attitude, TPS performance, etc. While the suite is similar to that carried on the successful MSL (Mars Science Laboratory) mission in 2012, it now includes pressure sensors, thermocouple plugs, and radiometers on the backshell as well. An analysis plan is therefore necessary to help with the interpretation of flight measurements.

Atmospheric Entry↗

MEDLI2: Ablator Models for Flight

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating[1,2]. Discrepancies between MEDLI’s flight heating data and predicted thermal response and recession[3] led to a campaign to characterize and test Mars2020 and MEDLI2 (Mars Entry, Descent, and Landing Instrument 2)[4] flight-lot thermal protection materials (TPS) at relevant ground test conditions. This paper covers the development and validation of flight-lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material SLA-561V (Super Lightweight Ablator). Virgin and char properties such as thermal conductivity and emissivity were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties were characterized and determined to be similar to prior TPS material measurements used for the heritage models. MEDLI2 also investigated the impact of the protective coating that was applied to MSL and Mars2020’s PICA heatshield to reduce the particulate matter shedding. Evidence from arc jet experiments on coated PICA showed that although there were no adverse effects on the performance of the TPS, there were differences in the in-depth temperatures and reduced recession compared to material response predictions of uncoated PICA.[5,6]. Fully Implicit Ablation and Thermal response (FIAT)[7] material response simulations were conducted with the heritage and MEDLI2 flight-lot material models. FIAT-predicted in-depth temperature responses and recession predictions were compared to flight-lot certification ground-test arc jet test data and MEDLI2 thermocouple data.

Materials Response↗

Data Fusion of In-Flight Aerothermodynamic Heating Measurements Using Kalman Filtering

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perserverance rover to the surface of Mars at Jezero Crater. The entry capsule carried a set of instrumentation installed on the heat shield and backshell, named the Mars 2020 Entry, Descent, and Landing Instrumentation. The instruments include pressure transducers, thermocouples, heat flux gauges, and radiometers to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. Three of these sensors, a thermocouple plug, heat flux gauge, and a radiometer, are located in close proximity on the backshell. Each sensor is exposed to roughly the same environment, but measured these environments in different ways, each with its own set of modeling and measurement error complications. This paper develops a method for blending each of these measurements together in a single algorithm to produce estimates of the aerothermodynamic environments at that location on the backshell. The approach makes use of the Kalman filter methodology for solving state estimation problems. The filter has a predictor/corrector structure in which simplified process models are used to propagate the aeroheating states forward through time, which are then updated based on the measurement data. The method has been tested on simulated datasets.

Christopher D. Karlgaard↗

MEDLI2 Material Response Model Development and Validation

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating and temperatures. Discrepancies between MEDLI’s recorded in-depth heating data and the predicted thermal response and recession led to a campaign to characterize and test Mars Entry, Descent, and Landing Instrument 2 (MEDLI2) flight lot thermal protection materials (TPS) at relevant temperatures and pressures for Martian entry conditions. This paper covers the development and validation of MEDLI2 flight lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material Super-Lightweight Ablator (SLA-561V). Virgin and char thermal conductivities were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties such as virgin and char density, emissivity, absorptivity, and specific heat capacitance was also characterized and compared to the “Heritage” models used during the TPS design phase of Mars 2020. Fully Implicit Ablation and Thermal response (FIAT) simulations were completed using the Heritage and MEDLI2 material response models to provide evidence of the increased accuracy of the MEDLI2 model. FIAT predicted in-depth temperatures were compared to flight lot certification ground-test arc jet test data and MEDLI2 flight thermocouple data.

Material response↗

MEDLI2: MISP Inferred Aerothermal Environment and Flow Transition Assessment

The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite on the Mars2020 mission contained multiple sensors on the aeroshell to measure the aerothermal environment during entry into the Martian atmosphere. These sensors performed superbly and successfully returned forebody and aftbody heating measurements. Analysis of MEDLI2 data indicated flow transitioning from a laminar to turbulent state on the heatshield. No evidence of flow transition was observed on the backshell. Two methods were used to estimate flow transition times on the heatshield: (1) temperature gradient of near-surface thermocouple data and (2) heat flux gradient from an inverse reconstruction approach using thermocouple data and material response modeling. Both methods produced similar transition times with an estimated accuracy of ±1 s. To assess various transition criteria, transition parameters were evaluated at each sensor location using flow field solutions from computational fluid dynamics (CFD) simulations. The idea was to use conservative values inferred from MEDLI2 data as transition criteria for other Mars missions. To test this hypothesis, MEDLI data from the Mars Science Laboratory (MSL) mission was used to compare predicted vs. actual flow transition times. The comparisons suggest smooth wall transition criteria are not well-suited in modeling the rapid progression of a turbulent transition front. Transition criteria containing a roughness element parameter agreed better with the flight data. In summary, critical transition values derived from MEDLI2 data may be used as a starting point in constructing a flow transition model for future Mars missions.

Chun Y Tang↗

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. This suite included a network of MEDLI2 Instrumented Sensor Plugs (MISPs). Each MISP was comprised of a cylinder made of Thermal Protection System (TPS) material with 1-3 embedded thermocouples (TCs), and it was flush mounted into the heatshield or backshell. Data from these in-depth TCs were used to reconstruct the aeroheating environment of the vehicle throughout entry. Surface heating was posed as an inverse problem, with the goal of estimating the surface heating by minimizing an objective function of the difference between MISP temperature measurements during flight and the temperature predictions derived from the Fully Implicit Ablation and Thermal response (FIAT) program. Given an aerothermal environment, FIAT calculates the material response and provides in-depth temperatures throughout the TPS material. To achieve the reverse, an internal tool called FIAT_Opt runs through multiple different environments until the output temperature at the TC depth closely matches the flight data. 95% confidence intervals on the reconstructed surface heating were obtained using Monte Carlo analysis, in which uncertainties in the thermocouple depth and the TPS material properties (e.g., density, thermal conductivity, heat capacity, emissivity) based on flight-lot material testing were included. A variance decomposition method using Sobol indices was employed to assess the sensitivity of the reconstructed peak heating to the TC placement and material property uncertainties. Variance decomposition was found to require tens of thousands of FIAT_Opt runs in order for the Sobol indices to converge. With a single FIAT_Opt run taking on the order of 40 minutes, the required number of computations would take months to complete, even if using multiple CPUs. To mitigate this problem, three machine learning models (ridge regression with cross-validation, random forest regression, and a deep neural network) were trained and tested using the 2000 Monte Carlo runs that were already completed. A subset of 1600 runs were used to train the model (i.e., training set), while the remaining 400 runs were used as the test set. The predictions from the deep neural network (DNN) on the test set showed nearly perfect agreement to the actual values computed with FIAT_Opt (R2 > 0.99). Using the DNN as a surrogate model, the variance decomposition using 50,000 runs was completed within minutes. The resulting Sobol indices showed that the reconstructed peak surface heating was most sensitive to the uncertainties in the thermal conductivity (ST = 0.37) and heat capacity (ST = 0.26). This method can be leveraged to provide requirements for material property measurements needed to improve the accuracy of surface heating prediction and ultimately lead to the reduction of design margins in the future. This presentation will include background on the MEDLI2 suite; the method used for inverse heating estimation; the way that material property uncertainties were accounted for using Monte Carlo analysis; a brief background on variance decomposition; the motivation for using machine learning in this context; how a neural network was trained on the data to enable variance decomposition in a fraction of the time; and the variance decomposition results for one of the MISPs.

Hannah Alpert↗

Data Fusion of In-Flight Aerothermodynamic Heating Measurements Using Kalman Filtering

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perseverance rover to the surface of Mars at Jezero Crater. The entry capsule carried instrumentation installed on the heatshield and backshell, named the Mars Entry, Descent, and Landing Instrumentation 2. The instruments included pressure transducers, thermocouples, heat flux gauges, and a radiometer to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. Three of these sensors, a thermocouple plug, heat flux gauge, and a radiometer, were co-located on the backshell. The sensors were exposed to roughly the same aerodynamic heating, but measured these environments in different ways, each with its own set of modeling and measurement error complications. This paper develops a method for blending each of these measurements together in a single algorithm to produce estimates of the aerothermodynamic environments at that backshell location. The approach makes use of the Kalman-Schmidt filter/smoother methodology, where systematic measurement error parameters are modeled as multiplicative states that are estimated by the filter along with the aerothermal states. The results indicate peak convective and radiative heating values of 0.86 and 5.16 W/cm2, respectively, compared to the filter predictive model values of 0.67 and 4.83 W/cm2.

Christopher D Karlgaard↗

Data Fusion of In-Flight Aerothermodynamic Heating Measurements Using Kalman Filtering

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perseverance rover to the surface of Mars at Jezero Crater. The entry capsule carried instrumentation installed on the heatshield and backshell, named the Mars Entry, Descent, and Landing Instrumentation 2. The instruments included pressure transducers, thermocouples, heat flux gauges, and a radiometer to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. Three of these sensors, a thermocouple plug, heat flux gauge, and a radiometer, were co-located on the backshell. The sensors were exposed to roughly the same aerodynamic heating, but measured these environments in different ways, each with its own set of modeling and measurement error complications. This paper develops a method for blending each of these measurements together in a single algorithm to produce estimates of the aerothermodynamic environments at that backshell location. The approach makes use of the Kalman-Schmidt filter/smoother methodology, where systematic measurement error parameters are modeled as multiplicative states that are estimated by the filter along with the aerothermal states. The results indicate peak convective and radiative heating values of 0.86 and 5.16 W/cm$^2$, respectively, compared to the filter predictive model values of 0.67 and 4.83 W/cm$^2$.

Christopher D Karlgaard↗

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. An inverse estimation of the backshell and heatshield surface aeroheating was performed, using the data from the MEDLI2 Instrumented Sensor Plugs, a network of thermocouples embedded within the thermal protection system across the aeroshell. Monte Carlo analysis was conducted to assess the sensitivity of the surface heat rate, temperature, and heat load to uncertainties in thermocouple depth and material properties. In this paper, a variance decomposition method using Sobol indices was employed to understand the relative contributions of each uncertainty parameter. Performing this analysis using results from the inverse analysis tool FIAT_Opt was found to require incredibly high computation time, and thus machine learning models were trained and evaluated as a surrogate model for FIAT_Opt. This paper demonstrates that machine learning models can be an efficient, accurate alternative to state-of-the-art inverse analysis tools like FIAT_Opt, especially for computationally-expensive processes. Using these models, the sensitivity analysis showed that uncertainties in heat capacity and thermal conductivity were the main drivers for the overall uncertainty in peak reconstructed heating and heat load.

H S Alpert↗

BOLT II Roughness-Side Flight Results

An initial review of the roughness data from the BOLT II flight is provided. The BOLT II roughness experiment was designed to investigate discrete trips in flight based on the diamond configuration, which has been shown to be an efficient vortex generator and boundary layer trip from extensive ground-based testing. There were three trip locations chosen for the flight test and their size (height and width) were tailored to the local boundary layer thickness, but all three were expected to trip at the same time or flight condition. Details about the flight vehicle design, instrumentation, and best estimated trajectory are discussed. The present paper is limited to only a review and analysis of the thermocouple data. Boundary layer transition onset times are derived from the thermocouple analysis, thus allowing an initial assessment of the performance of these discrete trips. Since the three trips were sized to trip the boundary layer at the same time, based on a previous wind tunnel study, the present analysis indicates that they performed as expected.

Hypersonic↗

Computational Icing Analysis on NASA’s SIDRM Geometry to Investigate Collection Efficiency

Computational icing analysis results were compared to experimental icing tunnel data including aerothermal (e.g. dry air) and supercooled water droplet rime-ice conditions from tests conducted in early 2022 at the NASA Icing Research Tunnel (IRT). The Simulated Intercompressor Duct Research Model (SIDRM) test article was used in this study, and its geometry represents the inter-compressor duct region of a turbofan engine. The test article’s purpose is to study the physics of supercooled water icing and ice crystal icing. This study compared three different icing codes: FENSAP-ICE (Eulerian approach), LEWICE3D (Lagrangian approach), and GlennICE (Lagrangian approach). All three icing codes were conducted on SIDRM’s complex body flow-field and compared to different experimental supercooled water rime runs. The test article instrumentation (pressure taps, thermocouples, etc.) and 3D laser scans of final ice shapes were used to compare against the different icing code simulations. The overall objectives are to understand how the icing codes handle capturing collection efficiency on the complex test article’s unheated surfaces. In the aerothermal cases, pressure tap readings matched the CFD results, but dry air CFD underpredicted thermocouple readings. Collection efficiency results from all three icing codes matched well together on the main body leading edge, main body slope, and the strut leading edges. All three icing codes underpredicted the final ice shape using a single-shot constant ice density approach, with more difficulty coming from the strut leading edge ice shape due to the swept wing like flow field. NASA’s overall goal for this effort is to develop computational icing tools to assist in the design and certification of engines for flight in icing conditions.

Supercooled icing, SIDRM, aerodynamics, computatio↗

Overview and Performance of the LOFTID Instrumentation Suite

On November 10, 2022, NASA launched the Low-earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle as a secondary payload mounted inside the launch vehicle adaptor on an Atlas V out of the Vandenburg Space Force Base (VSFB). The primary payload, Joint Polar Satellite System-2 (JPSS-2), was delivered successfully to a sun synchronous trajectory shortly after launch, at which point the Centaur upper stage performed a burn to de-orbit the system. Once on the desired trajectory to enter the atmosphere the payload adaptor canister was ejected by the payload adapter separation system to expose the packed LOFTID vehicle, then the LOFTID aeroshell, a Hypersonic Inflatable Aerodynamic Decelerator (HIAD), was deployed and inflated as planned. The Centaur pointed the LOFTID vehicle to the desired attitude to enter the atmosphere, spun the assembly to roughly three rpm, and separated the reentry vehicle. The LOFTID vehicle entered the atmosphere over Alaska at >8km/sec and decelerated as designed demonstrating stable flight from hypersonic entry through subsonic parachute deployment. On-board visible light cameras captured the reactions of the heatshield through all phases of flight, and co-located infrared light cameras captured the temperature distribution of the aft side of the heat shield anchored to a distribution of thermocouples on the inflatable structure (IS) in the field of view. Thermocouples were also embedded in the forward side of the aeroshell both in the Flexible Thermal Protection System (FTPS) as well as the IS. Heat Flux Gages and Pressure Transducers measured the heating rate and surface pressure experienced by the rigid nose of the reentry vehicle. Loadcells measured the interface loads between the IS and the rigid centerbody. This paper will discuss many of the key instruments flown on the successful LOFTID technology demonstration mission and will provide some high level results, while pointing to more detailed papers on the post-flight analyses.

Gregory T Swanson↗