Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Temperature distributions and gradients in laser-heated plasmas relevant to magnetized liner inertial fusion

We present two-dimensional temperature measurements of magnetized and unmagnetized plasma experiments performed at Z relevant to the preheat stage in magnetized liner inertial fusion. The deuterium gas fill was doped with a trace amount of argon for spectroscopy purposes, and time-integrated spatially resolved spectra and narrow-band images were collected in both experiments. The spectrum and image data were included in two separate multiobjective analysis methods to extract the electron temperature spatial distribution T e ( r , z ) . The results indicate that the magnetic field increases T e , the axial extent of the laser heating, and the magnitude of the radial temperature gradients. Comparisons with simulations reveal that the simulations overpredict the extent of the laser heating and underpredict the temperature. Temperature gradient scale lengths extracted from the measurements also permit an assessment of the importance of nonlocal heat transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Resolved Thomson Scattering on Laboratory Plasma Jets

In this study, Thomson scattering measurements were performed on plasma jets created from a 15-μm-thick radial Al foil load on a 1-MA pulsed power machine. The laser used for these measurements has a maximum energy of 10 J at 526.5 nm. Using the full energy, however, significantly heats the 5x10¹⁸ cm⁻³ jet by inverse bremsstrahlung, creating a density bubble in the jet. To measure the evolving plasma parameters of this laser-heated jet, a streak camera was used to record the scattered spectrum, resulting in the sub-ns time-resolved Thomson scattering. Analysis of the streak camera image showed that the electron temperature of the jet was about 25 eV prior to the laser pulse. The laser then heated the plasma to 80-100 eV within about 2 ns. The electron temperature then stabilized for about 0.5 ns prior to falling at the end of the laser pulse. Jets made from a radial Ti foil showed more heating by the laser than the Al jets, going from 50 to over 150 eV, and heating was detected even when only 1 J of laser energy was used. Also, the ion-acoustic peaks in the scattered spectrum from the Ti jets were significantly narrower than those from Al jets, a result of several possible differences in the plasma created from these two materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and Theoretical Needs for the JWST Early Release Science Program on Radiative Feedback from Massive Stars (PDRs4ALL): III. A Quantum Chemistry Perspective

Massive stars disrupt their natal molecular cloud material by dissociating molecules, ionizing atoms and molecules, and heating the gas and dust. These processes drive the evolution of interstellar matter in our Galaxy and throughout the Universe from the era of vigorous star formation at z=1-3 to the present day. Much of this interaction occurs in Photo- Dissociation Regions (PDRs) where far-ultraviolet photons of these stars create a largely neutral, but warm region of gas and dust. PDR emission dominates the IR spectra of starforming galaxies and provides a unique tool to study the physical and chemical processes that are relevant for inter- and circumstellar media including diffuse clouds, molecular cloud and protoplanetary disk surfaces, and starburst galaxies. The ERS program ID1288 is dedicated to provide template data as well as data processing and analysis tools for PDRs. To this end, it will observe the Orion Bar, the proto-typical PDR situated in the nearby Orion Nebula, using NIRSpec IFU, MIRI IFU, and NIRCAM and MIRI imaging. These observations will, for the first time, spatially resolve and perform a tomography of the PDR, revealing the individual IR spectral signatures from the key zones and sub-regions within the ionized gas, the PDR, and the molecular cloud. Quantum chemistry can be used to determine molecular data such as ionization potentials, chemical reaction rates, electronic spectra, dissociation energies, channels, and branching ratios, etc. These are often used in synergy with experiment to take advantage of the strengths of each approach. An area of active research is modeling the infrared (IR) emission spectra produced by PAH molecules, including the effects of anharmonicity. This will be important in the interpretation of JWST data which will yield higher-resolution spectral data compared to Spitzer or ISO. Quantum chemistry methods can compute accurate anharmonic IR absorption spectra of PAH molecules up to about 25 C atoms, and the results have been benchmarked against high-resolution experimental spectra. These feed into a quantum Monte Carlo (QMC) approach to generate temperature-dependent anharmonic IR emission spectra and then used to generate fully anharmonic cascade emission IR spectra of PAH molecules -- the very type of spectra that JWST will observe. Work continues to extend these methods to larger PAH molecules. We will discuss the current state of this work, as well as

Timothy Lee↗

Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging

Chemical plume detection and modeling in complex terrain present numerous challenges. We present experimental results from outdoor releases of two chemical tracers (sulfur hexafluoride and Freon-152a) from different locations in mountainous terrain. Chemical plumes were detected using two standoff instruments collocated at a distance of 1.5 km from the plume releases. A passive long-wave infrared hyperspectral imaging system was used to show time- and space-resolved plume transport in regions near the source. An active infrared swept-wavelength external cavity quantum cascade laser system was used in a standoff configuration to measure quantitative chemical column densities with high time resolution and high sensitivity along a single measurement path. Both instruments provided chemical-specific detection of the plumes and provided complementary information over different temporal and spatial scales. The results show highly variable plume propagation dynamics near the release points, strongly dependent on the local topography and winds. Effects of plume stagnation, plume splitting, and plume mixing were all observed and are explained based on local topographic and wind conditions. Measured plume column densities at distances ~100 m from the release point show temporal fluctuations over ~1 s time scales and spatial variations over ~1 m length scales. The results highlight the need for high-speed and spatially resolved measurement techniques to provide validation data at the relevant spatial and temporal scales required for high-fidelity terrain-aware microscale plume propagation models.

47 OTHER INSTRUMENTATION↗

Progress of Mechanical Design of Nanopositioning Stages at the Advanced Photon Source

Here, we present the upgraded Advanced Photon Source (APS) will be optimized to produce hard X-rays with a high degree of spatial coherence, and will exceed the capabilities of today's synchrotrons by two to three orders of magnitude in brightness and coherent flux in the hard X-ray range [1]. It will particularly benefit techniques such as advanced X-ray nanoprobes for nanoscale imaging, nanospectroscopy, and nanodiffraction. It will also benefit coherent diffractive imaging and ptychography with spatial resolution approaching atomic length scales and permitting time-resolved studies [2]. Meanwhile, many beamlines will be upgraded to take advantage of the smaller emittance for nanofocusing and nano-scale imaging. All of these methodologies will need novel precision X-ray instruments, including nanopositioning stages, to make full use of the new diffraction-limited storage ring capabilities. Although commercial companies produce a wide variety of state-of-the-art nanopositioning stages, there are specific scientific research goals that cannot be addressed adequately with commercial products. In these cases, it is necessary to push the engineering limits and develop in-house, customized nanopositioning stages to meet the scientific research goals. In this technical report, we outline the progress of mechanical designs of APS-developed nanopositioning instrumentation for synchrotron radiation instrumentation (SRI) applications. First, we describe flexure stages that use both overconstrained weak-link mechanisms and commercial flexure pivots. Finally, we describe a new, highly stable stage system for hard X-ray microscopy applications, called the Velociprobe.

47 OTHER INSTRUMENTATION↗

Spatially resolved polarization swings in the supermassive binary black hole candidate OJ 287 with first Event Horizon Telescope observations

We present the first Event Horizon Telescope 1.3 mm observations of the supermassive binary black hole candidate OJ 287. The observations achieved an unprecedented angular resolution of 18 μas and reveal significant structural and polarization variability over just five days, marking the shortest timescale on which such changes have been directly imaged in this source. The inner jet exhibits a twisted ridgeline structure, with features displaying apparent superluminal motions up to about 22 c. The linear polarization maps reveal three main polarized features whose electric-vector position angles (EVPAs) change substantially over the time span of our observations, including a component with a radial polarization consistent with being produced by a recollimation shock. Most notably, we directly resolved two innermost jet components whose EVPAs rotate in opposite directions. The faster component, moving at 2.4 ± 0.9 μas/day (17.4 ± 6.5 c), exhibits counterclockwise EVPA swings of roughly 3.7° per day, while the slower component, with a proper motion of 1.4 ± 0.3 μas/day (10.2 ± 2.2 c), rotates clockwise at approximately 2.5° per day. Previous studies inferred helical magnetic fields in AGN jets from time-resolved or integrated polarization variability but lacked the angular resolution to directly image this effect. Our results provide spatially resolved evidence that a helical magnetic field threads the jet’s collimation and acceleration zone, ruling out models based on the superposition of unresolved components. Our analysis suggests that propagating shocks interact with a Kelvin–Helmholtz plasma instability, illuminating different phases of the helical magnetic field and producing the observed polarization spatial and temporal variability. Moreover, our model naturally accounts for the more rapid polarization rotation observed in the faster moving component. Our model predicts even more rapid swings in polarization, which could be tested with future observations featuring a more densely sampled time coverage.

OJ 287↗

A Qualitative Investigation of Selected Infrared Flow Visualization Image Processing Techniques

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel testenvironment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is discussed as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity.This method makes use of dynamic mode decomposition and discrete-time filtering to separate the background reflections that dominate low emissivity surfaces from the aerodynamic driven surface temperature gradients.This process will be shown to resolve the onset of boundary layer transition on a bare metal wing as well as identify and resolve hidden features in the image data. While the implementation of this technique is very preliminary it demonstrates the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Image Processeing↗

Highly Resolved Mapping of NO 2 Vertical Column Densities From GeoTASO Measurements Over a Megacity and Industrial Area During the KORUS-AQ Campaign

The Korea–United States Air Quality (KORUS-AQ) campaign is a joint study between the United States National Aeronautics and Space Administration (NASA) and the South Korea National Institute of Environmental Research (NIER) to monitor megacity and transboundary air pollution around the Korean Peninsula using airborne and ground-based measurements. Here, tropospheric nitrogen dioxide (NO 2 ) slant column density (SCD) measurements were retrieved from Geostationary Trace and Aerosol Sensor Optimization (GeoTASO) L1B data during the KORUS-AQ campaign (2 May to 10 June 2016). The retrieved SCDs were converted to tropospheric vertical column densities using the air mass factor (AMF) obtained from a radiative transfer calculation with trace gas profiles and aerosol property inputs simulated with the Community Multiscale Air Quality (CMAQ) model and surface reflectance data obtained from the Moderate Resolution Imaging Spectroradiometer (MODIS). For the first time, we examine highly resolved (250 m × 250 m resolution) tropospheric NO 2 over the Seoul and Busan metropolitan regions and the industrial region of Anmyeon. We reveal that the maximum NO 2 vertical column densities (VCDs) were 4.94×10 16 and 1.46×10 17 molec. cm −2 at 09:00 and 15:00 LT over Seoul, respectively, 6.86×10 16 and 4.89×10 16 molec. cm −2 in the morning and afternoon over Busan, respectively, and 1.64×10 16 molec. cm −2 over Anmyeon. The VCDs retrieved from the GeoTASO airborne instrument were correlated with those obtained from the Ozone Monitoring Instrument (OMI) (r=0.48), NASA's Pandora Spectrometer System (r=0.91), and NO 2 mixing ratios obtained from in situ measurements (r=0.07 in the morning, r=0.26 in the afternoon over the Seoul, and r>0.56 over Busan). Based on our results, GeoTASO is useful for identifying NO 2 hotspots and their spatial distribution in highly populated cities and industrial areas.

Gyo-Hwang Choo↗

Electron Ghost Imaging

Here in this paper, we report a demonstration of electron ghost imaging. A digital micromirror device directly modulates the photocathode drive laser to control the transverse distribution of a relativistic electron beam incident on a sample. Correlating the structured illumination pattern to the total sample transmission then retrieves the target image, avoiding the need for a pixelated detector. In our example, we use a compressed sensing framework to improve the reconstruction quality and reduce the number of shots compared to raster scanning a small beam across the target. Finally, compressed electron ghost imaging can reduce both acquisition time and sample damage in experiments for which spatially resolved detectors are unavailable (e.g., spectroscopy) or in which the experimental architecture precludes full frame direct imaging.

43 PARTICLE ACCELERATORS↗

Interference-free optical detection for Raman spectroscopy

An architecture for spontaneous Raman scattering (SRS) that utilizes a frame-transfer charge-coupled device (CCD) sensor operating in a subframe burst gating mode to realize time-resolved combustion diagnostics is disclosed. The technique permits all-electronic optical gating with microsecond shutter speeds (<5 .mu.s), without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally-polarized excitation lasers, the technique measures time-resolved vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Nguyen, Quang-Viet↗

Probing atom dynamics of excited Co-Mo-S nanocrystals in 3D

Advances in electron microscopy have enabled visualizations of the three-dimensional (3D) atom arrangements in nano-scale objects. The observations are, however, prone to electron-beam-induced object alterations, so tracking of single atoms in space and time becomes key to unravel inherent structures and properties. Here, we introduce an analytical approach to quantitatively account for atom dynamics in 3D atomic-resolution imaging. The approach is showcased for a Co-Mo-S nanocrystal by analysis of time-resolved in-line holograms achieving ~1.5 Å resolution in 3D. The analysis reveals a decay of phase image contrast towards the nanocrystal edges and meta-stable edge motifs with crystallographic dependence. These findings are explained by beam-stimulated vibrations that exceed Debye-Waller factors and cause chemical transformations at catalytically relevant edges. This ability to simultaneously probe atom vibrations and displacements enables a recovery of the pristine Co-Mo-S structure and establishes, in turn, a foundation to understand heterogeneous chemical functionality of nanostructures, surfaces and molecules.

36 MATERIALS SCIENCE↗

Carbon Fiber Oxidation in 4D

The oxidation of carbon fibers at high temperatures is the primary degradation process in the thermal protection system of many hypersonic flight vehicles. Predicting the rate and the extent of oxidation is critical to ensure a safe and effective design. An oversized thermal protection system adds unnecessary mass, while an under-designed one risks system failure and mission loss. Resolving high-temperature material degradation due to oxidation has been a long-standing challenge in designing for re-entry flight environments. Using time-resolved in situ X-ray microtomography, the oxidation of carbon fibers at high temperatures is directly imaged, resolving the two limiting degradation regimes: diffusion- and reaction-limited. The ability to resolve material degradation in time at the sub-micron scale sheds light on the ablation phenomenon and enables predictions of material constitutive properties evolving in time, with profound implications on the ability to model the aerothermal response of heat shield materials in hostile environments.

ablation↗

Influence of orbital symmetry on diffraction imaging with rescattering electron wave packets

The ability to directly follow and time-resolve the rearrangement of the nuclei within molecules is a frontier of science that requires atomic spatial and few-femtosecond temporal resolutions. While laser-induced electron diffraction can meet these requirements, it was recently concluded that molecules with particular orbital symmetries (such as pg) cannot be imaged using purely backscattering electron wave packets without molecular alignment. Here, we demonstrate, in direct contradiction to these findings, that the orientation and shape of molecular orbitals presents no impediment for retrieving molecular structure with adequate sampling of the momentum transfer space. We overcome previous issues by showcasing retrieval of the structure of randomly oriented O 2 and C 2 H 2 molecules, with π g and π u symmetries, respectively, and where their ionization probabilities do not maximize along their molecular axes. As a result, while this removes a serious bottleneck for laser-induced diffraction imaging, we find unexpectedly strong backscattering contributions from low-Z atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamic Analysis of Reynolds Number Effects on Trailing Edge Transonic Vortex Shedding and Its Impact on Turbine Blade Aerodynamic Performance

Time-resolved, high-speed self-aligned focusing schlieren images were acquired in the NASA Glenn Research Center Transonic Turbine Blade Cascade facility to help understand the aerodynamic behavior of high-pressure, thick trailing edge turbine blades. The trailing edge thickness of 9% of axial chord tested represents simulated ceramic matrix composite fabrication constraints, which was verified previously to possess a high-loss flow regime at high inlet turbulence conditions over a narrow range of Reynolds numbers and at a fixed design exit Mach number of 0.74. Our high-speed images, which were acquired at 10 distinct Reynolds numbers, show a significant increase in energy from flow oscillations due to transonic vortex shedding at Reynolds numbers corresponding to the high loss conditions. For those conditions, strong acoustic waves turn into shock waves. Spectral Proper Orthogonal Decomposition of the high-speed images shows acoustic waves from trailing edge vortex shedding at all conditions, with increased spectral energy at the high-loss conditions and slightly increasing frequency (about 6%) as a function of Reynolds number. Analysis of potential feedback timing is performed using velocity fields from a previous LES simulation, considering different feedback mechanisms. Most noteworthy is the acoustic/shock-boundary layer interaction mechanism on the suction surface at the blade geometric throat, which likely plays an important role in realistic curved blade passages.

Trailing Edge↗

THE EXTRAORDINARY COMPLEX MAGNETIC FIELD OF THE HELIUM-STRONG STAR HD 37776

The early-type chemically peculiar stars often show strong magnetic fields on their surfaces. These magnetic topologies are organized on large scales and are believed to be close to an oblique dipole for most of the stars. In a striking exception to this general trend, the helium-strong star HD 37776 shows an extraordinary double-wave rotational modulation of the longitudinal magnetic field measurements, indicating a topologically complex and, possibly, record-strong magnetic field. Here we present a new investigation of the magnetic field structure of HD 37776, using both simple geometrical interpretation of the longitudinal field curve and detailed modeling of the time-resolved circular polarization line profiles with the help of a magnetic Doppler imaging technique. We derive a model of the magnetic field structure of HD 37776, which reconciles for the first time all magnetic observations available for this star. We find that the local surface field strength does not exceed {approx}30 kG, while the overall field topology of HD 37776 is dominated by a non-axisymmetric component and represents by far the most complex magnetic field configuration found among early-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

High Mass Accuracy and High Mass Resolving Power FT-ICR Secondary Ion Mass Spectrometry for Biological Tissue Imaging

Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for exact mass elemental formula assignment. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissue was measured with 150 μm spatial resolution (75 μm primary ion spot size) with mass resolving power (m/Δm50%) of 67,500 (at m/z 750) and root-mean-square measurement accuracy less than two parts-per-million for intact phospholipids, small molecules and fragments. For the first time, ultra-high mass resolving power SIMS has been demonstrated, with m/Δm50% > 3,000,000. Higher spatial resolution capabilities of the platform were tested at a spatial resolution of 20 μm. The results represent order of magnitude improvements in mass resolving power and mass measurement accuracy for SIMS imaging and the promise of the platform for ultra-high mass resolving power and high spatial resolution imaging.

Environmental Molecular Sciences Laboratory↗

Commissioning of a Cask Enabling Characterization of Irradiated Nuclear Fuels with Pulsed Neutrons

Irradiation tests are a key component of nuclear fuel development and identifying typical and atypical regions in the irradiated fuel volume relies on very few characterization techniques. The goal of the effort reported here is to provide complementary measurements adding to the available parameter space for post irradiation examination as well as to inform subsequent hot cell PIE examinations by identifying typical and atypical regions with respect to microstructure, tomographic data, or isotope densities. Pulsed neutrons, enabling diffraction as well as energy-resolved neutron imaging and neutron absorption resonance spectroscopy, offer unique capabilities for this purpose. Time-of-flight neutron diffraction has the potential to offer efficient, non-destructive and non-contact microstructural characterization of irradiated fuel pins with spatial resolution of 1 mm 3 to 1 cm 3 while for energy-resolved neutron imaging (and by extension tomography) a resolution of 100 μm was demonstrated. The potential results include crystallinity vs. amorphous volumes and microstructural information such as phase compositions, lattice strains (indicative of residual stresses or chemistry variations) and textures from the diffraction data as well as distances (e.g. pellet to cladding), cracks, and isotopic distributions of minor actinides, fission products as well as fission gas partial pressures e.g. in the plenum from energy resolved neutron imaging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress Report on Mockup Irradiation Capsule Fuel Measurements at LANSCE

Irradiation tests are a key component of nuclear fuel development and identifying typical and atypical regions in the irradiated fuel volume relies on very few characterization techniques. The goal of the effort reported here is to provide complementary measurements adding to the available parameter space for post irradiation examination as well as to inform subsequent hot cell PIE examinations by identifying typical and atypical regions with respect to microstructure, tomographic data, or isotope densities. Pulsed neutrons, enabling diffraction as well as energy-resolved neutron imaging and neutron absorption resonance spectroscopy, offer unique capabilities for this purpose. Time-of-flight neutron diffraction has the potential to offer efficient, non-destructive and non-contact microstructural characterization of irradiated fuel specimen with spatial resolution of 1 mm 3 to 1 cm 3 while for energy-resolved neutron imaging (and by extension tomography) a resolution of 100 μm 3 was demonstrated. The potential results include crystallinity vs. amorphous volumes and microstructural information such as phase compositions, lattice strains (indicative of residual stresses or chemistry variations) and textures from the diffraction data as well as distances (e.g. pellet to cladding), cracks, and isotope densities of minor actinides, fission products as well as fission gas partial pressures e.g. in the plenum from energy resolved neutron imaging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗