Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transonic wind tunnel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

High Reynolds number tests of a Douglas DLBA 032 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

A wind-tunnel investigation of a Douglas advanced-technology airfoil was conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). The temperature was varied from 227 K (409 R) to 100 K (180 R) at pressures ranging from about 159 kPa (1.57 atm) to about 514 kPa (5.07 atm). Mach number was varied from 0.50 to 0.78. These variables provided a Reynolds number range (based on airfoil chord) from 6.0 to 30.0 x 10 to the 6th power. This investigation was specifically designed to: (1) test a Douglas airfoil from moderately low to flight-equivalent Reynolds numbers, and (2) evaluate sidewall-boundary-layer effects on transonic airfoil performance characteristics by a systematic variation of Mach number, Reynolds number, and sidewall-boundary-layer removal. Data are included which demonstrate the effects of fixing transition, Mach number, Reynolds number, and sidewall-boundary-layer removal on the aerodynamic characteristics of the airfoil. Also included are remarks on model design and model structural integrity.

Johnson, Charles B.↗

Assessment of an Unstructured-Grid Method for Predicting Aerodynamic Performance of Jet Flaps

The application of a Computational Fluid Dynamics tool to a jet flap control effector on an elliptical airfoil-section wing was investigated. The study utilized the Tetrahedral Unstructured Software System developed at NASA Langley Research Center. The Reynolds-averaged Navier-Stokes flow solver code used was USM3D. The CFD-based jet flap simulations were compared to experimental results from a wind tunnel test conducted at the NASA Langley Transonic Dynamics Tunnel. The wind tunnel model consisted of a six percent thick elliptical airfoil with a modified trailing edge. The jet flap was located at 95% chord and exited at 90 degrees to the lower surface. The experimental model was designed to promote two-dimensional flow across the wing. It was found that the CFD simulation had to model the three-dimensional geometry of the experiment in order to obtain good agreement. Tests were performed at two Mach numbers at several different jet momentum coefficients. In order to be consistent with the experimental method, the CFD lift and pitching moment values were determined by integrating the pressures over the wing.

Cruz, Josue↗

High Reynolds number test of a NACA 651-213, a equals 0.5 airfoil at transonic speeds

Wind-Tunnel tests were conducted in the Lockheed-Georgia Company's compressible flow facility to determine the transonic two-dimensional aerodynamic characteristics of a NACA 65 sub 1-213 a = 0.50 airfoil. The results are correlated with data obtained in the NASA-Langley 8-foot transonic pressure tunnel and the NAE high Reynolds number 15x60-inch two-dimensional test facility. The tests were conducted over a Mach number range from 0.60 to 0.80 and an angle of attack range from -1 deg to 8 deg. Reynolds numbers, based on the airfoil chord, were varied.

Burdges, K. P.↗

Using transonic small disturbance theory for predicting the aeroelastic stability of a flexible wind-tunnel model

The CAP-TSD (Computational Aeroelasticity Program - Transonic Small Disturbance) code, developed at the NASA - Langley Research Center, is applied to the Active Flexible Wing (AFW) wind tunnel model for prediction of the model's transonic aeroelastic behavior. Static aeroelastic solutions using CAP-TSD are computed. Dynamic (flutter) analyses are then performed as perturbations about the static aeroelastic deformations of the AFW. The accuracy of the static aeroelastic procedure is investigated by comparing analytical results to those from previous AFW wind tunnel experiments. Dynamic results are presented in the form of root loci at different Mach numbers for a heavy gas and air. The resultant flutter boundaries for both gases are also presented. The effects of viscous damping and angle-of-attack, on the flutter boundary in air, are presented as well.

Silva, Walter A.↗

An inventory of aeronautical ground research facilities. Volume 1: Wind tunnels

A survey of wind tunnel research facilities in the United States is presented. The inventory includes all subsonic, transonic, and hypersonic wind tunnels operated by governmental and private organizations. Each wind tunnel is described with respect to size, mechanical operation, construction, testing capabilities, and operating costs. Facility performance data are presented in charts and tables.

Pirrello, C. J.↗

High Reynolds number tests of the cast 10-2/DOA 2 airfoil in the Langley 0.3-meter transonic cryogenic tunnel, phase 2

Wind tunnel tests of an advanced technology airfoil, the CAST 10-2/DOA 2, were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). This was the third of a series of tests conducted in a cooperative airfoil research program between the National Aeronautics and Space Administration and the Deutsche Forschungsund Versuchsanstalt fur Luft- und Raumfahrt e. V. For these tests, temperature was varied from 270 K to 110 K at pressures from 1.5 to 5.75 atmospheres. Mach number was varied from 0.60 to 0.80, and the Reynolds number (based on airfoil chord) was varied from 2 to 20 million. The aerodynamic data for the 7.62 cm chord airfoil model used in these tests is presented without analysis. Descriptions of the 0.3-m TCT, the airfoil model, the test instrumentation, and the testing procedures are included.

Dress, D. A.↗

Velocity and Temperature Measurements in High-speed Flows with Naturally Present Dust Particles Using Rayleigh and Mie Scattering

Dust particles and occasional moisture condensations are unavoidable reality of all wind tunnels. On the path to pursue a goal of velocity and temperature measurements in large transonic and supersonic wind tunnels we have created a tabletop, spectrally resolved, Rayleigh-Mie scattering setup around a small jet fed by ambient and lightly seeded air to determine the viability and accuracy of the technique. The other reality of a wind tunnel setup is the background scattering or the glare at laser frequency, which contaminates the Rayleigh-Mie scattered light. This is simulated by backgrounds with different reflectivity towards the collection optics. Light from a CW laser is delivered via an optical fiber and the scattered light is spectrally resolved using a stabilized Fabry-Perot interferometer, followed by imaging on an EMCCD camera. A model of the of the combined background glare, Mie scattering, and the Rayleigh spectrum was fitted to the camera image using maximum likelihood estimation. Since the background glare occurs at the known frequency of the incident light and the Mie scattering peak corresponds to the Doppler shift from the bulk velocity, both were easily identified, and provided a measure of flow velocity. Preliminary results show that the Rayleigh spectrum can also be resolved, which provides a measure of temperature. It is observed that a slight drift of the laser frequency during data collection affected fitting of the model function leading to larger error. A feedback loop-based stabilization system is on development to take advantage of slight tunability of the laser via a piezo-control. Preliminary results are presented in the abstract. More extensive data from a systematic survey will be presented in the final paper.

Rayleigh scattering↗

Transonic flutter and gust-response tests and analyses of a wind-tunnel model of a torsion-free-wing fighter airplane

The paper reports the results of analytical and exploratory wind-tunnel studies of the transonic flutter and gust response characteristics of a 1/5.5-size complete-airplane version of a torsion-free-wing (TFW) fighter aircraft. The critical flutter mode for the TFW-free configuration was found to occur at M = 0.95 and had the rigid-TFW pitch mode as its apparent aerodynamic driver. However, the minimum dynamic flutter for the TFW-free case was only about 20% lower than for the TFW-locked; therefore the present TFW is a viable design concept with respect to flutter. The present TFW was not effective as a gust alleviator.

Ruhlin, C. L.↗

Pressure distributions from high Reynolds number tests of a Boeing BAC 1 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

A wind-tunnel investigation designed to test a Boeing advanced-technology airfoil from low to flight-equivalent Reynolds numbers has been completed in the Langley 0.3-Meter Transonic Cryogenic Tunnel. This investigation represents the first in a series of NASA/U.S. industry two-dimensional airfoil studies to be completed in the Advanced Technology Airfoil Test program. Test temperature was varied from ambient to about 100 K at pressures ranging from about 1.2 to 6.0 atm. Mach number was varied from about 0.40 to 0.80. These variables provided a Reynolds number (based on airfoil chord) range from 4.4 X 10 to the 6th power to 50.0 X 10 to the 6th power. All the test objectives were met. The pressure data are presented without analysis in plotted and tabulated formats for use in conjunction with the aerodynamic coefficient data published as NASA TM-81922. At the time of the test, these pressure data were considered proprietary and have only recently been made available by Boeing for general release. Data are included which demonstrate the effects of fixed transition. Also included are remarks on the model design, the model structural integrity, and the overall test experience.

Johnson, W. G., Jr.↗

Enhancements to the FAST-MAC Circulation Control Model and Recent High-Reynolds Number Testing in the National Transonic Facility

A second wind tunnel test of the FAST-MAC circulation control model was recently completed in the National Transonic Facility at the NASA Langley Research Center. The model was equipped with four onboard flow control valves allowing independent control of the circulation control plenums, which were directed over a 15% chord simple-hinged flap. The model was configured for low-speed high-lift testing with flap deflections of 30 and 60 degrees, along with the transonic cruise configuration with zero degree flap deflection. Testing was again conducted over a wide range of Mach numbers up to 0.88, and Reynolds numbers up to 30 million based on the mean chord. The first wind tunnel test had poor transonic force and moment data repeatability at mild cryogenic conditions due to inadequate thermal conditioning of the balance. The second test demonstrated that an improvement to the balance heating system significantly improved the transonic data repeatability, but also indicated further improvements are still needed. The low-speed highlift performance of the model was improved by testing various blowing slot heights, and the circulation control was again demonstrated to be effective in re-attaching the flow over the wing at off-design transonic conditions. A new tailored spanwise blowing technique was also demonstrated to be effective at transonic conditions with the benefit of reduced mass flow requirements.

Milholen, William E., II↗

Transonic assessment of two-dimensional wind tunnel wall interference using measured wall pressures

A method is described for assessing wall interference in two dimensional wind tunnels with better realism and accuracy than is achieved with methods based on classical wall interference theory. Measured pressure distributions were imposed as boundary conditions on a nonlinear transonic form of the potential equation to obtain an accurate computational reproduction of the actual tunnel flow. Wall-induced velocity perturbations were then extracted to yield both corrections to the tunnel test conditions and a measure of the adequacy of these corrections to account for tunnel interference. Application of the method to a transonic tunnel with variable porosity walls is illustrated.

Kemp, W. B., Jr.↗

Using transonic small disturbance theory for predicting the aeroelastic stability of a flexible wind-tunnel model

The CAP-TSD (Computational Aeroelasticity Program-Transonic Small Disturbance) code, developed at the NASA-Langley Research Center, is applied to the Active Flexible Wing (AFW) wind-tunnel model for prediction of the model's transonic aeroelastic behavior. Static aeroelastic solutions using CAP-TSD are computed. Dynamic (flutter) analyses are then performed as perturbations about the static aeroelastic deformations of the AFW. The accuracy of the static aeroelastic procedure is investigated by comparing analytical results to those from previous AFW wind-tunnel experiments. Dynamic results are presented in the form of root loci at different Mach numbers for a heavy gas and air. The resultant flutter boundaries for both gases are also presented. The effects of viscous damping and angle-of-attack, on the flutter boundary in air, are presented as well.

Silva, Walter A.↗

Test-to-Test Repeatability of Results From a Subsonic Wing-Body Configuration in the National Transonic Facility

Results from three wind tunnel tests in the National Transonic Facility of a model of an advanced-technology, subsonic-transport wing-body configuration have been analyzed to assess the test-to-test repeatability of several aerodynamic parameters. The scatter, as measured by the prediction interval, in the longitudinal force and moment coefficients increases as the Mach number increases. Residual errors with and without the ESP tubes installed suggest a bias leading to lower drag with the tubes installed. Residual errors as well as average values of the longitudinal force and moment coefficients show that there are small bias errors between the different tests.

Mineck, Raymond E.↗

Procedures for Computing Transonic Flows for Control of Adaptive Wind Tunnels

Numerical methods are developed for control of three dimensional adaptive test sections. The physical properties of the design problem occurring in the external field computation are analyzed, and a design procedure suited for solution of the problem is worked out. To do this, the desired wall shape is determined by stepwise modification of an initial contour. The necessary changes in geometry are determined with the aid of a panel procedure, or, with incident flow near the sonic range, with a transonic small perturbation (TSP) procedure. The designed wall shape, together with the wall deflections set during the tunnel run, are the input to a newly derived one-step formula which immediately yields the adapted wall contour. This is particularly important since the classical iterative adaptation scheme is shown to converge poorly for 3D flows. Experimental results obtained in the adaptive test section with eight flexible walls are presented to demonstrate the potential of the procedure. Finally, a method is described to minimize wall interference in 3D flows by adapting only the top and bottom wind tunnel walls.

Rebstock, Rainer↗