Search NASASearch

SEARCH · Search NASA

Results for “Vehicle-to-grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,786 records · Page 37

Research and development of high thermal stability fuels

Increases in aircraft performance are leading to increases in the thermal stress on the primary aircraft coolant--the fuel. Fuel thermal stability limitations may offset future aircraft performance gains. The Air Force's Wright Laboratory is sponsoring several research programs to address this problem. The development of an additive package for JP-8 to improve its thermal stability is the primary focus of this paper. This program involves extensive testing of fuels and additives in a variety of test devices, culminating in tests in a fuel system simulator and engine tests. These tests involve Air Force personnel, on-site contractors (University of Dayton Research Institute, Systems Research Laboratories), Pratt and Whitney Aircraft Co., additive manufacturers, and Sandia National Laboratory. The test devices include several flowing and static tests, where the behavior of a fuel is investigated in a wide variety of environments. The study of several baseline fuels in these devices has led to some new insights into the mechanisms of fuel thermal (in)stability. It is becoming clear that a fuel's tendency to oxidize (to form peroxides, for example) is often inversely proportional to its tendency to form insoluble deposits.

T Edwards

Nitrile/Buna N Material Failure Assessment for an O-Ring used on the Gaseous Hydrogen Flow Control Valve (FCV) of the Space Shuttle Main Engine

After the rollout of Space Shuttle Discovery in April 2005 in preparation for return-to-flight, there was a failure of the Orbiter (OV-103) helium signature leak test in the gaseous hydrogen (GH2) system. Leakage was attributed to the Flow Control Valve (FCV) in Main Engine 3. The FCV determined to be the source of the leak for OV-103 is designated as LV-58. The nitrile/Buna N rubber O-ring seal was removed from LV-58, and failure analysis indicated radial cracks providing leak paths in one quadrant. Cracks were eventually found in 6 of 9 FCV O-rings among the three Shuttle Orbiters, though none were as severe as those for LV-58, OV-103. Testing by EM10 at MSFC on all 9 FCV O- rings included: laser dimensional, Shore A hardness and properties from a dynamic mechanical analyzer (DMA) and an Instron tensile machine. The following test data was obtained on the cracked quadrant of the LV-58, OV-103 O-ring: (1) the estimated compression set was only 9.5%, compared to none for the rest of the O-ring; (2) Shore A hardness for the O.D. was higher by almost 4 durometer points than for the rest of the O-ring; and (3) DMA data showed that the storage/elastic modulus E was almost 25% lower than for the rest of the O-ring. Of the 8 FCV O-rings tested on an Instron, 4 yielded tensile strengths that were below the MIL spec requirement of 1350 psi-a likely influence of rubber cracking. Comparisons were made between values of modulus determined by DNA (elastic) and Instron (Young s). Each nitrile/Buna N O-ring used in the FCV conforms to the MIL-P-25732C specification. A number of such O-rings taken from shelf storage at MSFC and Kennedy Space Center (KSC) were used to generate a reference curve of DMA glass transition temperature (Tg) vs. shelf storage time ranging from 8 to 26 years. A similar reference curve of TGA onset temperature (of rubber weight loss) vs. shelf storage time was also generated. The DMA and TGA data for the used FCV O-rings were compared to the reference curves. Correlations were also made between the DMA modulus (at 22 C) and Shore A hardness for all 9 of the FCV O-rings used among the three Shuttle Orbiters. The radial cracking in the FCV O-rings was determined to be due to ozone attack, as nitrile/Buna N rubber is susceptible to such attack. Nitrile/Buna N material under MIL-P25732C should be used in a hydraulic fluid environment to help protect it from cracking. However, the FCV O-rings were used in an air only environment. The FCV design has as much as a 9-mil gap that allows the O.D. of the O-ring to be directly exposed to ozone, pressurized air and some elevated temperatures, accelerating the weathering process that leads to O-ring cracking. Space Shuttle flights will likely not continue past 2010. Therefore, Shuttle management decided to continue using the nitrile/Buna N material for the FCVs, but have each O-ring replaced after 3 years to minimize any chances for crack initiation.

Doug Wingard

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

The role of fast and slow dynamics in nonlinear resonant ultrasound spectroscopy of consolidated granular materials

Abstract Elastic nonlinearity observed in consolidated granular media can be attributed to the combination of slow and fast effects, which give rise to hysteresis and relaxation of both modulus and damping after the sample is perturbed. A consequence is a high level of complexity in the measurements of the sample linear and nonlinear elastic parameters. The results of experiments are dependent on the experimental protocol that is adopted to measure the relevant quantities and it is hard to quantify parameters with accuracy and repeatability. Here we focus on examining Nonlinear Resonant Ultrasound Spectroscopy, showing experimentally the role of slow dynamics in the process and quantifying/discussing its influence on the quantification of nonlinearity. We also propose a model to describe the process, which shows that different contributions to nonlinearity (e.g., classical and hysteretic) could be due to physical features (defects) relaxing with different relaxation times.

Science & Technology - Other Topics

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg

Global Characterization of Polygonally Fractured Terrain on Venus and Implications for a Climate Change Origin

On Earth, polygonal fractures with spacings of 1-100 cm form in lava flows that cool slowly under isotropic stress conditions. On Venus, polygonal fractures are observed with typical fracture spacings of 1-2 km, covering regions 10s to 100s of km across. These features have been proposed to form via cooling of lava flows or above subsurface intrusions, or due to surface cooling caused by climate change. A watershed algorithm was modified to search the entire Magellan image database autonomously for terrains with polygonal fractures. Here we characterize the 204 polygon terrains found using this method (including over 170 newly identified regions) with respect to size, morphology, stratigraphy, and geologic setting. These results are used to examine different models of origin.

S. E. Smrekar

DS-2 Mars Microprobe Battery

In January of 1999 the NM DS-2 Mars microprobe will be launched to impact on Mars in December. The technical objectives of the missions are to demonstrate: key technologies, a passive atmospheric entry, highly integrated microelectronics which can withstand both low temperatures and high decelerations, and the capability to conduct in-situ, surface and subsurface science data acquisition. The scientific objectives are to determine if ice is present below the Martian surface, measure the local atmospheric pressure, characterize the thermal properties of the martian subsurface soil, and to estimate the vertical temperature gradient of the Martian soil. The battery requirements are 2-4 cell batteries, with voltage of 6-14 volts, capacity of 550 mAh at 80C, and 2Ah at 25C, shelf life of 2.5 years, an operating temperature of 60C and below, and the ability to withstand shock impact of 80,000 g's. The technical challenges and the approach is reviewed. The Li-SOCL2 system is reviewed, and graphs showing the current and voltage is displayed, along with the voltage over discharge time. The problems encountered during the testing were: (1) impact sensitivity, (2) cracking of the seals, and (3) delay in voltage. A new design resulted in no problems in the impact testing phase. The corrective actions for the seal problems involved: (1) pre weld fill tube, (2) an improved heat sink during case to cover weld and (3) change the seal dimensions to reduce stress. To correct the voltage delay problem the solutions involved: (1) drying the electrodes to reduce contamination by water, (2) assemblage of the cells within a week of electrode manufacture, (3) ensure electrolyte purity, and (4) provide second depassivation pulse after landing. The conclusions on further testing were that the battery can: (1) withstand anticipated shock of up to 80,000 g, (2) meet the discharge profile post shock at Mars temperatures, (3) meet the required self discharge rate and (4) meet environmental requirements.

Frank, H.

Review of European Microgravity Measurements

AA In a French/Russion cooperation, CNES developed a microgravity detection system for analyzing the Mir space station micro-g-environment for the first time. European efforts to characterize the microgravity (1/9) environment within a space laboratory began in the late seventies with the design of the First Spacelab Mission SL-1. Its Material Science Double Rack was the first payload element to carry its own tri-axial acceleration package. Even though incapable for any frequency analysis, the data provided a wealth of novel information for optimal experiment and hardware design and operations for missions to come. Theoretical investigations under ESA contract demonstrated the significance of the detailed knowledge of micro-g data for a thorough experiment analysis. They especially revealed the high sensitivity of numerous phenomena to low frequency acceleration. Accordingly, the payloads of the Spacelab missions D-1 and D-2 were furnished with state-of-the-art detection systems to ensure frequency analysis between 0.1 and 100 Hz. The Microgravity Measurement Assembly (MMA) of D-2 was a centralized system comprising fixed installed as well as mobile tri-axial packages showing real-time data processing and transmission to ground. ESA's free flyer EURECA carried a system for continuous measurement over the entire mission. All EURECA subsystems and experimental facilities had to meet tough requirements defining the upper acceleration limits. In a French/Russion cooperation, CNES developed a mi crogravity detection system for analyzing the Mir space station micro-g-environment for the first time. An approach to get access to low frequency acceleration between 0 and 0.02 Hz will be realized by QSAM (Quasi-steady Acceleration Measurement) on IML-2, complementary to the NASA system Spacelab Acceleration Measurement System SAMS. A second flight of QSAM is planned for the Russian free flyer FOTON.

H Hamacher

From Pollutant Removal to Renewable Energy: MoS2-Enhanced P25-Graphene Photocatalysts for Malathion Degradation and H2 Evolution

The widespread presence of pesticides—especially malathion—in aquatic environments presents a major obstacle to conventional remediation strategies, while the ongoing global energy crisis underscores the urgency of developing renewable energy sources such as hydrogen. In this context, photocatalytic water splitting emerges as a promising approach, though its practical application remains limited by poor charge carrier dynamics and insufficient visible-light utilization. Herein, we report the design and evaluation of a series of TiO2-based ternary nanocomposites comprising commercial P25 TiO2, reduced graphene oxide (rGO), and molybdenum disulfide (MoS2), with MoS2 loadings ranging from 1% to 10% by weight. The photocatalysts were fabricated via a two-step method: hydrothermal integration of rGO into P25 followed by solution-phase self-assembly of exfoliated MoS2 nanosheets. The composites were systematically characterized using X-ray diffraction (XRD), Raman spectroscopy, transmission electron microscopy (TEM), UV-Vis diffuse reflectance spectroscopy (DRS), and photoluminescence (PL) spectroscopy. Photocatalytic activity was assessed through two key applications: the degradation of malathion (20 mg/L) under simulated solar irradiation and hydrogen evolution from water in the presence of sacrificial agents. Quantification was performed using UV-Vis spectroscopy, gas chromatography–mass spectrometry (GC-MS), and thermal conductivity detection (GC-TCD). Results showed that the integration of rGO significantly enhanced surface area and charge mobility, while MoS2 served as an effective co-catalyst, promoting interfacial charge separation and acting as an active site for hydrogen evolution. Nearly complete malathion degradation (~100%) was achieved within two hours, and hydrogen production reached up to 6000 µmol g−1 h−1 under optimal MoS2 loading. Notably, photocatalytic performance declined with higher MoS2 content due to recombination effects. Overall, this work demonstrates the synergistic enhancement provided by rGO and MoS2 in a stable P25-based system and underscores the viability of such ternary nanocomposites for addressing both environmental remediation and sustainable energy conversion challenges.

Chemistry

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig

Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

Brewer, Jeffrey C.

Progress on Shape Memory Alloy Actuator Development for Active Clearance Control

Results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine has been conducted. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 in. Design results show that an actuator comprised of 10 wires 2 in. in length is adequate for control at critical engine operating points and still exhibit acceptable failsafe operability and cycle life. A proportional-integral- derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

Jonathan DeCastro

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series were: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

TVAC

Long Life Molten Salt Battery for NASA Venus Application

A development program is being conducted at Advanced Thermal Batteries (ATB) to create a low discharge rate, long life, molten salt battery for a NASA Venus surface probe. Battery goals are 60 days continuous operation at +25V +0/-6 volts and -25V +6/-0 Volts under severe environments of 465°C, 92 atm pressure, and corrosive sulfur dioxide in a super critical carbon dioxide atmosphere. Conveniently, molten salt thermal battery electrochemistry starts to operate efficiently at 330°C. However, a major barrier to direct application of existing thermal battery technology is the high self-discharge rate, resulting in lifetimes in only minutes, not days. The best performance to date, which meets the required voltage regulation, has been a lithium silicon (LiSi) alloy anode discharging through all three voltage plateau versus an iron monosulfide (FeS) cathode. In order to perform reproducibly, additional engineering controls within the battery design are required to limit cell–to–cell parasitic discharge mechanisms. Results of these trials have improved the efficiency and manufacturability of the design.

Thermal Battery

Towards an improved understanding of the Antarctic coastal zone and its contribution to future global sea level

Understanding the coastal zone of the Antarctic Ice Sheet, where it interacts with the Southern Ocean and warmer air masses, is crucial for predicting Antarctica's influence on the global climate. This region has multiple tipping mechanisms that could trigger large, rapid, and potentially irreversible changes in the coming centuries. The Antarctic Ice Sheet remains the largest source of uncertainty in future sea-level projections. Insufficient knowledge of bed topography beneath the ice shelves and the coastal ice sheet is not yet well documented, but is a major source of this uncertainty. This review assesses current knowledge of the coastal zone and highlights methods to investigate it, including aerogeophysical surveys, ground- and ship-based measurements, satellite observations, and computer modeling. An ensemble analysis of published bed topography datasets identifies significant data gaps and their regional distribution, framed in the context of current ice-sheet behavior and potential instability. We propose scientific priorities and guidelines for future aerogeophysical surveys, advocating for a comprehensive, coordinated international effort to build a next-generation dataset of Antarctic bed properties. Such an initiative would significantly advance understanding of the role of coastal processes in ice-sheet dynamics, reducing uncertainties in sea-level rise projections and enhancing predictions of future ocean and climate changes.

Kenichi Matsuoka

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health

Calculations of the Moon's Thermal History at Different Concentrations of Radioactive Elements, Taking Into Account Differentiation on Melting

Calculations of the thermal history of the moon were carried out by solving the thermal conductivity equation for the case in which the heat sources are the long-lived radioactive elements Th, U, and K 40 . The concentrations of these elements were adjusted to give four variations of the heat flow: 1.35 x 10 -8 and 0.91 x 10 -6 cal cm -2 s -1 (I and I**), 0.61 x 10 -6 (variant II, the terrestrial mixture of Lyubimova and Starkova), and 0.236 x 10 -6 (variant III, the chondrite model of Urey and MacDonald). In the same calculations, we considered layering of the differentiated material with transport to the surface of the radioactive elements after the temperature of the layer rose to 200 K above the melting temperature, which is considered in five variants that differ in the amount of transported radioactive elements: 100 percent ( n = 1), 80 percent n = 0.8), 40 percent, 20 percent ( n = 0.6, 0.4, 0.2). During fusion the heat capacity and heat conductivity were changed. We considered two variants of an initially cold (273 K) and hot (900 K) Moon. Calculations show that the interior of the Moon was heated to melting during the first 0.7 to 2.3 x 10 9 years. The maximum fusion involved practically the entire Moon to a distance from 15 to 45 km beneath the surface, and started 3.5 to 4.0 x 10 9 years ago (I, I**), or 2.5 to 3.0 x 10 9 years ago (II, III) and continued for 1 to 2 x 10 9 years. Today the Moon is cooling. The current thickness of the solid crust is from 150 to 200 km and the heat flow exceeds the stationary value 1.5 fold. Apparently the most realistic variant is II (terrestrial mixture) for an initially hot Moon, and gives, regardless of the moderate concentration of radioactive elements, a heat flow of 0.9 to 0.95 x 10 -6 cal cm -2 s -1 , which agrees with the radioastronomical measurements of Troitsky and Krotikov and with the Apollo 15 data.

O I Ornatskaya

Multikilowatt Bipolar Nickel/Hydrogen Battery

High energy densities appear feasible. Nickel/hydrogen battery utilizing bipolar construction in common pressure vessel, addressing needs for multikilowatt storage for low-Earth-orbit applications, designed and 10-cell prototype model tested. Modular-concept-design 35-kW battery projected energy densities of 20 to 24 Wh/b (160 to 190 kj/kg) and 700 to 900 Wh/ft3 (90 to 110 MJ/m3) and incorporated significant improvements over state-of-the-art storage systems.

Source record