Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Space-Charge Compensation Using Electron Columns at IOTA

Beam loss due to space charge is a major problem at current and future high intensity particle accelerators. The space charge force can be compensated for proton or ion beams by creating a column of electrons with a charge distribution matched to that of the beam, maintaining electron-proton stability. The column is created by the beam ionizing short sections of high pressure gas. The ionization electrons are then shaped appropriately using electric and magnetic fields. The Integrable Optics Test Accelerator (IOTA) at Fermilab is a test bed for beam loss and instability mitigation techniques. Simulations using the particle-in-cell code, Warp, have been made to track the evolution of both the electron column and the beam over multiple passes. A 2.5 MeV proton beamline is under construction at IOTA, to be used to study the effect of the electron column on a space charge dominated beam.

43 PARTICLE ACCELERATORS↗

Report on Oak Ridge National Laboratory Testing of Ambient Cure TransPowr E3X®

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductor and conductor instrumentation under field conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr® with Ambient Cure E3X™ Technology—a standard overhead conductor with a high emissivity, low absorptivity ambient cure surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures with respect to uncoated conductor of the same type, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Investigation of Catastrophic Failure in Solid-State Lamps Exposed to Harsh Environment Operational Conditions

Today’s lighting technology is steadily becoming more energy efficient and less toxic to the environment since the passing of the Energy Independence and Security Act of 2007 (EISA) [1]. EISA has mandated a higher energy efficiency standard for lighting products and the phase out of the common incandescent lamp. This has led lighting manufacturers to pursue solid-state lighting (SSL) technologies for consumer lighting applications. However, two major roadblocks are hindering the transition process to SSL lamps: cost and quality. In order to cut cost, manufactures are moving towards cheaper packaging materials and a variety of package architecture construction techniques which may potentially erode the quality of the lamp and reduce its survivability in everyday applications. Typically, SSL lamps are given product lifetimes of over twenty years based off of the IES TM-21-11 lighting standard which does not include moisture effects or large operational temperatures [2]. A group of recently released off-the-shelf lamps have undergone a steady-state temperature humidity bias life test of 85°C/85%RH (85/85) to investigate the reliability in harsh environment applications. The lack of accelerated test methods for lamps to assess reliability prior to introduction into the marketplace does not exist in literature. There is a need for SSL physics based models for the assessment and prediction of a lamp’s lifetime which is being spearheaded by the DOE [3]. In order to be fully accepted in the marketplace, SSL lamps must be able to perform similarly to incandescent lamps in these environments, as well as live up to the lifetime claims of manufacturers. A lamp’s package architecture must be designed with performance factors in mind, as well as address some of the known and published package related failure mechanisms, such as carbonization of the encapsulant material, delamination, encapsulant yellowing, lens cracking, and phosphor thermal quenching [4]. Each failure mechanism produces the similar failure mode of lumen degradation predominately due to two contributing factors: high junction temperature and moisture ingress. The current state-of-the-art has focused on individual areas of the lamp, such as the LED chip, substrate material, electrical driver design and thermal management techniques. [5] – [16] Looking at the lamp as a whole is a novel approach and has not been seen before in literature. This work followed the JEDEC standard JESD22-A101C of 85/85 with a one hour interval of applied voltage followed by a one hour interval of no applied voltage [17]. This test was performed continuously for each SSL lamp until it became nonoperational, i.e. did not turn on. Periodically, photometric measurements were taken following the IES LM-79-08 standard at room temperature using an integrating sphere, a spectrometer, and lighting software. The overall health of the SSL lamps was assed using the relative luminous flux (RLF), correlated color temperature (CCT) and the color difference (Δu'v') using the Euclidean distance of the CIE 1976 color space coordinates. Finally, a Weibull analysis was completed to compare the characteristic lifetime of the SSL lamp to the actual rated lifetime. An important result from this work shows that the rated lifetime does not come close to the actual lifetime when the SSL lamps are used in a harsh humid environment which is fairly common in outdoor applications across the U.S. Also, the photometric results are presented for the entire lifetime of each SSL lamp under test.

54 ENVIRONMENTAL SCIENCES↗

Beam Position Monitor and Energy Analysis at the Fermilab Accelerator Science and Technology Facility

Fermilab Accelerator Science and Technology Facility has produced its first beam with an energy of 20 MeV. This energy is obtained by the acceleration at the Electron Gun and the Capture Cavity 2 (CC2). When fully completed, the accelerator will consist of a photoinjector, one International Liner Collider (ILC)-type cryomodule, multiple accelerator R&D beamlines, and a downstream beamline to inject 300 MeV electrons into the Integrable Optics Test Accelerator (IOTA). We calculated the total energy of the beam and the corresponding energy to the Electron Gun and CC2. Subsequently, a Beam Position Monitors (BPM) error analysis was done, to calculate the device actual resolution.

43 PARTICLE ACCELERATORS↗

Overview of the New Beam Physics Research at the IOTA/FAST Facility

The Fermilab Accelerator Science and Technology (FAST) facility is dedicated to the exploration of novel concepts in accelerator and beam physics, and the development of a robust workforce, in order to enable and enhance next-generation particle accelerators. FAST comprises a high-brightness superconducting electron linac, and a storage ring, the Integrable Optics Test Accelerator (IOTA). Experiments in the most recent operational run include studies of nonlinear integrable lattices; tracking of single electrons; precise characterization of undulator radiation; studies with low-momentum-compaction lattices; and ultra-wide range beam diagnostics based on Photomultiplier tubes. In the linac, experiments on noise in intense electron bunches were conducted. The IOTA proton injector, currently being commissioned, will enable a diverse program on space-charge-dominated beams. Research areas include non-invasive beam profile monitoring for proton beams; beam dynamics with electron lenses; halo suppression, feedback systems, and electron cooling. In this presentation, we provide an overview of the recent results and highlight future plans together with opportunities for collaboration.

43 PARTICLE ACCELERATORS↗

Achievement and improvement of the JT-60U negative ion source for JT-60 Super Advanced (invited)

Developments of the large negative ion source have been progressed in the high-energy, high-power, and long-pulse neutral beam injector for JT-60 Super Advanced. Countermeasures have been studied and tested for critical issues of grid heat load and voltage holding capability. As for the heat load of the acceleration grids, direct interception of D{sup -} ions was reduced by adjusting the beamlet steering. As a result, the heat load was reduced below an allowable level for long-pulse injections. As for the voltage holding capability, local electric field was mitigated by tuning gap lengths between large-area acceleration grids in the accelerator. As a result, the voltage holding capability was improved up to the rated value of 500 kV. To investigate the voltage holding capability during beam acceleration, the beam acceleration test is ongoing with new extended gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Report on Oak Ridge National Laboratory Testing of Southwire 795 C7 Round Wire

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductors and conductor instrumentation under field conditions. PCAT is set up to capture large amounts of data during testing.

36 MATERIALS SCIENCE↗

Single event upset (SEU) of semiconductor devices - A summary of JPL test data

The data summarized describe single event upset (bit-flips) for 60 device types having data storage elements. The data are from 15 acceleration tests with both protons and heavier ions. Tables are included summarizing the upset threshold data and listing the devices tested for heavy ion induced bit-flip and the devices tested with protons. With regard to the proton data, it is noted that the data are often limited to one proton energy, since the tests were usually motivated by the engineering requirement of comparing similar candidate devices for a system. It is noted that many of the devices exhibited no upset for the given test conditions (the maximum fluence and the maximum proton energy Ep are given for these cases). It is believed, however, that some possibility of upset usually exists because there is a slight chance that the recoil atom may receive up to 10 to 20 MeV of recoil energy (with more energy at higher Ep).

Nichols, D. K.↗

Stress corrosion evaluation of powder metallurgy aluminum alloy 7091 with the breaking load test method

The stress corrosion behavior of the P/M aluminum alloy 7091 is evaluated in two overaged heat treatment conditions, T7E69 and T7E70, using an accelerated test technique known as the breaking load test method. The breaking load data obtained in this study indicate that P/M 7091 alloy is highly resistant to stress corrosion in both longitudinal and transverse orientations at stress levels up to 90 percent of the material yield strength. The reduction in mean breaking stress as a result of corrosive attack is smallest for the more overaged T7E70 condition. Details of the test procedure are included.

Domack, Marcia S.↗

Neutron generator based on intense lithium beam driver

We are proposing a compact neutron generator based on a Li beam driver. The proposed neutron generator comprises a laser ion source, a radio-frequency quadrupole linear accelerator (RFQ linac), a drift tube linac, and a target containing protons. In the generator, the lithium ion is used as a projectile instead of protons to utilize the kinematic focusing technique. The technique enables us to enhance the neutron flux without increasing the beam energy, which is important to develop a clean compact neutron generator. Moreover, the combination of a laser ion source and a RFQ linac with the direct plasma injection scheme will provide several tens of mA of a fully ionized lithium beam, which is much higher than that of conventional heavy ion sources comparable with proton drivers. Neutrons are generated by the nuclear reaction of the lithium ions and protons in the beam target. In this paper, we reported the current status of the development. For RFQ, we designed the RFQ rods to accelerate 40 mA of 7Li3+. We fabricated and installed the rods into a cavity, and, as a first test, accelerated 10 mA of C6+ successfully.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Evaluation of the Durability of Flexible Barrier Materials

To enable the production of lightweight photovoltaic modules, it is desired to use thin film absorbers on metal substrates in a flexible package. To do this with a polymer based frontsheet, it is estimated that a water vapor transmission rate (WVTR) less than 10-4 g/m2/day must be achieved and maintained through the expected life of the module. Barrier-frontsheet films have been developed at 3M with very low permeation rates and evaluated for their long term durability with respect to WVTR and optical transmittance. After exposure to 2500 h of 10 UV suns at 105 degrees C, one design was found which experienced negligible loss in optical transmission while maintaining a WVTR well below the required 10-4 g/m2/day. Further accelerated tests were conducted at different stress levels. For some less durable designs we were able to obtain degradation acceleration factors suggesting the highest exposure was equal to between 4.4 and 10 y on a roof.

14 SOLAR ENERGY↗

Evaluation of Stress Corrosion Cracking Susceptibility Using Fracture Mechanics Techniques, Part 1

Stress corrosion cracking (SSC) tests were performed on 13 aluminum alloys, 13 precipitation hardening stainless steels, and two titanium 6Al-4V alloy forgings to compare fracture mechanics techniques with the conventional smooth specimen procedures. Commercially fabricated plate and rolled or forged bars 2 to 2.5-in. thick were tested. Exposures were conducted outdoors in a seacoast atmosphere and in an inland industrial atmosphere to relate the accelerated tests with service type environments. With the fracture mechanics technique tests were made chiefly on bolt loaded fatigue precracked compact tension specimens of the type used for plane-strain fracture toughness tests. Additional tests of the aluminum alloy were performed on ring loaded compact tension specimens and on bolt loaded double cantilever beams. For the smooth specimen procedure 0.125-in. dia. tensile specimens were loaded axially in constant deformation type frames. For both aluminum and steel alloys comparative SCC growth rates obtained from tests of precracked specimens provide an additional useful characterization of the SCC behavior of an alloy.

Sprowls, D. O.↗

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Undulator Radiation of Single Electrons: Coherence Length and Quantum-Optical Properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Plasma wakefields in the quasi-nonlinear regime: Experiments at ATF

In this work we present details of planned experiments to investigate certain aspects of the quasi non linear regime (QNL) of plasma wakefield acceleration (PWFA). In the QNL regime it is, in principal, possible to combine the benefits of both nonlinear and linear PWFA. That is, beams of high quality can be maintained through acceleration due to the complete ejection of plasma electrons from beam occupied region, while large energy gains can be achieved through use of transformer ratio increasing schemes, such as ramped bunch trains. With the addition of an short focal length PMQ triplet capable of focusing beams to the few micron scale and the ability to generate tunable bunch trains, the Accelerator Test Facility (ATF) at Brookhaven National Lab offers the unique capabilities to probe these characteristics of the QNL regime.

43 PARTICLE ACCELERATORS↗

Partial Shade Endurance Testing for Monolithic Photovoltaic Modules

In monolithically integrated photovoltaic (PV) modules, including CdTe, CIGS, and a-Si modules, some shadows can cause permanent damage under some operating conditions. This damage reduces efficiency and causes shunts that are visible to the eye and in luminescence imaging. Although these shadows are sometimes forbidden by product documentation, we have observed this type of damage in utility-scale PV systems. Existing standards ensure that qualified modules are safe to use after they are damaged by shadows. But no standard test exists to quantify the loss of efficiency that can result from this damage. In this work we describe new, accelerated tests to quantify the power loss that occurs due to shadows from human bodies and narrow objects, such as tools, placed nearby or directly touching modules. The tests are designed to be easy to conduct uniformly across products and laboratories. The tests can be performed outdoors and last only a few minutes. In our trials on commercial products, these tests resulted in 2%-27% permanent loss in power at standard test conditions (STC). The relative loss was several times larger when measured at lower irradiance. The tests we describe can be used to differentiate products, to direct the development of technological solutions to shadow sensitivity at the cell and module levels, and to establish the need for system-level and administrative solutions to the occurrence of shadows. Similar tests will be the basis of a new International Electrotechnical Commission (IEC) technical specification (TS) 63140.

14 SOLAR ENERGY↗

Current cyclical testing for PV electrical connections

Cyclical testing of electrically conductive bonding (ECB) is provided. Cyclical testing comprises high current flows using multiples of max operating currents and monitoring sensors with periods of no current to accelerate testing of electrical connections employing ECBs.

Lin, Yafu↗