Search NASA⌕ Search

SEARCH · Search NASA

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

STITCHES: a Python package to amalgamate existing Earth system model output into new scenario realizations

Understanding the interaction between humans and the Earth system is a computationally daunting task, with many possible approaches depending on resources available and questions of interest. For example, state-of-the-art impact models require decade-long time series of relatively high frequency, spatially resolved and often multiple variables representing climatic impact-drivers (Ruane et al., 2022). Most commonly these are derived from the outputs of detailed, computationally expensive Earth System Models (ESMs) run according to a standard, limited set of future scenarios, the latest being the SSP-RCPs run under CMIP6/ScenarioMIP (Eyring et al., 2016; O’Neill et al., 2016). At the time of writing, O’Neill et al. (2016) has been cited more than 1750 times and Eyring et al. (2016) more than 5000 times, highlighting the broad, general applications of this data. Often, however, impact modeling seeks to explore new scenarios that were not part of the ScenarioMIP protocol, and/or needs a larger set of initial condition ensemble members than are typically available to quantify the effects of ESM internal variability. In addition, the recognition that the human and Earth systems are fundamentally intertwined, and may feature potentially significant feedback loops, is making integrated, simultaneous modeling of the coupled human-Earth system increasingly necessary, if computationally challenging with most existing tools (Thornton et al., 2017). For impact modelers, climate model emulators can be the answer to meet both the needs of: 1) creating realizations for novel scenarios and 2) achieving a simplified, computationally tractable representation of ESM behavior in a coupled human-Earth system modeling framework. We proposed a new, comprehensive approach to such emulation of gridded, multivariate ESM outputs for novel scenarios without the computational cost of a full ESM, STITCHES (Tebaldi et al., 2022). The approach outlined in Tebaldi et al. (2022) should be extensible to future CMIP eras, although the STITCHES software at present is strictly focused on CMIP6/ScenarioMIP data hosted on Pangeo (https://gallery.pangeo.io/repos/pangeo-gallery/cmip6/). The corresponding STITCHES Python package uses existing archives of ESMs’ scenario experiments from CMIP6/ScenarioMIP to construct gridded, multivariate realizations of new scenarios provided by reduced complexity climate models (Hartin et al., 2015; Meinshausen et al., 2011; Smith et al., 2018), or to enrich existing initial condition ensembles. Its output provides the same characteristics as the emulated ESM output: multivariate (spanning potentially all variables that the ESM has saved), spatially resolved (down to the native grid of the ESM), and preserving the same high frequency as the original data. A new realization of multiple variables can be generated on the order of minutes with STITCHES, rather than the hours or sometimes days that ESMs require.

97 MATHEMATICS AND COMPUTING↗

CSULA Hydrogen Refueling Facility Performance Evaluation and Optimization

Throughout its history, Cal State LA has been in the forefront of advanced energy and transportation technologies. The station is located at the intersection of two major highways in Los Angeles region and has a convenient access. It is capable of producing up to 60 kg/day and can fuel 15-20 vehicles per day. Cal State LA had partnered with DOE to establish a robust station operation and performance data collection program. This consisted of equipping the station with additional instrumentation and collecting fueling performance data for several years. The data was further furnished to NREL for processing and agglomeration with data from other stations. In addition to fueling, maintenance and failure events were shared as well as hydrogen purity reports. The station has also undergone several upgrades in fueling protocols and hardware for improved performance and code compliance.

08 HYDROGEN↗

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MSAT network architecture

The Mobile Satellite (MSAT) communications system will support mobile voice and data services using circuit switched and packet switched facilities with interconnection to the public switched telephone network and private networks. Control of the satellite network will reside in a Network Control System (NCS) which is being designed to be extremely flexible to provide for the operation of the system initially with one multi-beam satellite, but with capability to add additional satellites which may have other beam configurations. The architecture of the NCS is described. The signalling system must be capable of supporting the protocols for the assignment of circuits for mobile public telephone and private network calls as well as identifying packet data networks. The structure of a straw-man signalling system is discussed.

Davies, N. G.↗

Further analysis of the microgravity environment on Mir Space Station during Mir-16

The NASA Microgravity Science and Applications Division (MSAD) sponsors the Space Acceleration Measurement System (SAMS) to support microgravity science experiments with microgravity acceleration measurements. In the past, SAMS was flown exclusively on the NASA Orbiters. MSAD is currently sponsoring science experiments participating in the Shuttle-Mir Science Program in cooperation with the Russians on the Mir space station. Included in the complement of MSAD experiments and equipment is a SAMS unit installed on the Mir space station. On 25 August 1994, the SAM unit was launched on a Russia Progress vehicle to the Mir space station. The SAMS unit will support science experiments from the U.S. and Russia in a manner similar to the Orbiter missions by measuring the microgravity environment during the experiment operations. In October 1994, the SAMS unit recorded data on Mir for over fifty-three hours in seven different time periods to survey possible locations for future experiments. The Mir acceleration data were examined by the Principal Investigator, Microgravity Services, to develop characteristics of the data. A report was previously written to quickly summarize the characteristics of the SAMS data from Mir. That report contained an overview of data from the 100 Hertz (Hz) SAMS sensor head. This report presents an overview of the data from the 10 Hz SAMS sensor head and additional information about crew and vehicle activities. Some additional observations are also made concerning the 100 Hz sensor head data. Appendix A describes the procedures to access SAMS data by file transfer protocol (ftp) utilizing the internet. Appendices B and C provide plots of the SAMS 10 Hz data for an overview of the microgravity environment at the times that data were recorded. Appendix D contains a user comment sheet.

Ryaboukha, Stanislav↗

Design and Verification of a Distributed Communication Protocol

The safety of remotely operated vehicles depends on the correctness of the distributed protocol that facilitates the communication between the vehicle and the operator. A failure in this communication can result in catastrophic loss of the vehicle. To complicate matters, the communication system may be required to satisfy several, possibly conflicting, requirements. The design of protocols is typically an informal process based on successive iterations of a prototype implementation. Yet distributed protocols are notoriously difficult to get correct using such informal techniques. We present a formal specification of the design of a distributed protocol intended for use in a remotely operated vehicle, which is built from the composition of several simpler protocols. We demonstrate proof strategies that allow us to prove properties of each component protocol individually while ensuring that the property is preserved in the composition forming the entire system. Given that designs are likely to evolve as additional requirements emerge, we show how we have automated most of the repetitive proof steps to enable verification of rapidly changing designs.

Munoz, Cesar A.↗

Full-Scale Wind-Tunnel Investigation of Wing-Cooling Ducts Effects of Propeller Slipstream, Special Report

The safety of remotely operated vehicles depends on the correctness of the distributed protocol that facilitates the communication between the vehicle and the operator. A failure in this communication can result in catastrophic loss of the vehicle. To complicate matters, the communication system may be required to satisfy several, possibly conflicting, requirements. The design of protocols is typically an informal process based on successive iterations of a prototype implementation. Yet distributed protocols are notoriously difficult to get correct using such informal techniques. We present a formal specification of the design of a distributed protocol intended for use in a remotely operated vehicle, which is built from the composition of several simpler protocols. We demonstrate proof strategies that allow us to prove properties of each component protocol individually while ensuring that the property is preserved in the composition forming the entire system. Given that designs are likely to evolve as additional requirements emerge, we show how we have automated most of the repetitive proof steps to enable verification of rapidly changing designs.

Nickle, F. R.↗

Defining an Abrasion Index for Lunar Surface Systems as a Function of Dust Interaction Modes and Variable Concentration Zones

Unexpected issues were encountered during the Apollo era of lunar exploration due to detrimental abrasion of materials upon exposure to the fine-grained, irregular shaped dust on the surface of the Moon. For critical design features involving contact with the lunar surface and for astronaut safety concerns, operational concepts and dust tolerance must be considered in the early phases of mission planning. To systematically define material selection criteria, dust interaction can be characterized by two-body or three-body abrasion testing, and subcategorically by physical interactions of compression, rolling, sliding and bending representing specific applications within the system. Two-body abrasion occurs when a single particle or asperity slides across a given surface removing or displacing material. Three-body abrasion occurs when multiple particles interact with a solid surface, or in between two surfaces, allowing the abrasives to freely rotate and interact with the material(s), leading to removal or displacement of mass. Different modes of interaction are described in this paper along with corresponding types of tests that can be utilized to evaluate each configuration. In addition to differential modes of abrasion, variable concentrations of dust in different zones can also be considered for a given system design and operational protocol. These zones include: (1) outside the habitat where extensive dust exposure occurs, (2) in a transitional zone such as an airlock or suitport, and (3) inside the habitat or spacesuit with a low particle count. These zones can be used to help define dust interaction frequencies, and corresponding risks to the systems and/or crew can be addressed by appropriate mitigation strategies. An abrasion index is introduced that includes the level of risk, R, the hardness of the mineralogy, H, the severity of the abrasion mode, S, and the frequency of particle interactions, F.

Kobrick, Ryan L.↗

High Intensity Exercise Countermeasures does not Prevent Orthostatic Intolerance Following Prolonged Bed Rest

Approximately 20% of Space Shuttle astronauts became presyncopal during operational stand and 80deg head‐up tilt tests, and the prevalence of orthostatic intolerance increases after longer missions. Greater than 60% of the US astronauts participating in Mir and early International Space Station missions experienced presyncope during post‐flight tilt tests, perhaps related to limitations of the exercise hardware that prevented high intensity exercise training until later ISS missions. The objective of this study was to determine whether an intense resistive and aerobic exercise countermeasure program designed to prevent cardiovascular and musculoskeletal deconditioning during 70 d of bed rest (BR), a space flight analog, would protect against post‐BR orthostatic intolerance. METHODS Twenty‐six subjects were randomly assigned to one of three groups: non‐exercise controls (n=11) or one of two exercise groups (ExA, n=8; ExB, n=7). Both ExA and ExB groups performed the same resistive and aerobic exercise countermeasures during BR, but one exercise group received testosterone supplementation while the other received a placebo during BR in a double‐blinded fashion. On 3 d/wk, subjects performed lower body resistive exercise and 30 min of continuous aerobic exercise (≥75% max heart rate). On the other 3 d/wk, subjects performed only highintensity, interval‐style aerobic exercise. Orthostatic intolerance was assessed using a 15‐min 80 head‐up tilt test performed 2 d (BR‐2) before and on the last day of BR (BR70). Plasma volume was measured using carbon monoxide rebreathing on BR‐3 and before rising on the first recovery day (BR+0). The code for the exercise groups has not been broken, and results are reported here without group identification. RESULTS Only one subject became presyncopal during tilt testing on BR‐2, but 7 of 11 (63%) controls, 3 of 8 (38%) ExA, and 4 of 7 (57%) ExB subjects were presyncopal on BR70. Survival analysis of post‐BR tilt tests revealed no differences (p=0.77) between groups. Plasma volume (absolute or relative to body mass index) decreased (p<0.001) from pre to post‐BR, with no differences between groups. CONCLUSIONS These preliminary results corroborate previous reports that the performance of a vigorous exercise countermeasure protocol during BR, even with testosterone supplementation, does not protect against orthostatic intolerance or plasma volume loss. Preventing post‐BR orthostatic intolerance may require additional countermeasures, such as orthostatic stress during BR or end‐of‐BR fluid infusion.

Platts, Steven H.↗

Atom Interferometry for Detection of Gravitational Waves: NASA Institute for Advanced Concepts (NIAC) - Phase 1 Final Report

This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 "Atom Interferometry for Detection of Gravitational Waves" project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket

Saif, Babak N.↗

Identification of Cardiometabolic Vulnerabilities Caused by Effects of Synergistic Stressors that are Commonly Encountered During Space Missions

Microgravity is a physiologically challenging state even when at rest. Astronauts experience additional physical and mental stresses, such as prolonged exertion, sleep loss and circadian misalignment, that could impact cardiovascular function. The main goals of this four year NASA project are to characterize the independent and synergistic effects on cardiovascular and immune function of: (1) circadian misalignment; (2) sleep loss; and (3) varied physical and mental stressors, mimicking some of the synergistic stressors experienced by astronauts. Sixteen healthy volunteers, aged 35-55 years, will be studied with standardized behavioral stressors occurring across all circadian phases, both with and without accruing sleep loss, achieved via two 11-day "forced desynchrony" protocols performed in each subject (randomized, within-subject design), where wake periods are advanced 4-h each "day" (i.e. recurring 20-h "days"). One protocol permits 8.33 h sleep opportunity per 20-h "day" (=10 h sleep per 24-h), and the other permits 5 h sleep per 20-h "day" (=6 h sleep per 24-h; matching the reported sleep duration of astronauts). In both protocols, subjects will perform a standardized stress battery including a cognitively challenging task; bicycle exercise, and passive 60deg head up tilt. Outcome variables include blood pressure, heart rate, arrhythmia frequency, cardiac vagal tone (from heart rate variability), sympathetic activity (catecholamines), and endothelial function. Additional measures of cardiac function (echocardiography), responses to a passive 80deg head up tilt, maximal oxygen uptake, and immune function will be assessed at the beginning and at the end of each protocol (i.e., without and with sleep loss, and before and after circadian misalignment). We hope to identify the relative impact on cardiovascular risk markers of varied behavioural stressors while subjects experience circadian misalignment and sleep loss, mimicking some of the synergistic stressors experienced by astronauts. Supported by NASANNX1 OAR 1 OG.

Ruger, M.↗

iTOUGH2 v7.1

iTOUGH2 (inverse TOUGH2) provides inverse modeling capabilities for TOUGH2, a simulator for multi-dimensional, multi-phase, multi-component, non-isothermal flow and transport in fractured porous media. iTOUGH2 performs sensitivity analyses, data-worth analyses, parameter estimation, and uncertainty propagation analyses in geosciences and reservoir engineering and other application areas. iTOUGH2 supports a number of different combinations of fluids and components (equation-of-state (EOS) modules). In addition, the optimization routines implemented in iTOUGH2 can also be used for sensitivity analysis, automatic model calibration, and uncertainty quantification of any external code that uses text-based input and output files using the PEST protocol. iTOUGH2 solves the inverse problem by minimizing a non-linear objective function of the weighted differences between model output and the corresponding observations. Multiple minimization algorithms (derivative-free, gradient-based, and second-order; local and global) are available. iTOUGH2 also performs Latin Hypercube Monte Carlo simulations for uncertainty propagation analyses. A detailed residual and error analysis is provided. This upgrade includes (a) global sensitivity analysis methods, (b) dynamic memory allocation (c) additional input features and output analyses, (d) increased forward simulation capabilities, (e) parallel execution on multicore PCs and Linux clusters, and (f) bug fixes.

Finsterle, Stefan↗

Human Factors Ground Test Assessment and Protocol Development for Space Radiation Protection Concepts

Human factors evaluations and procedures were developed in a series of ground tests in order to assess novel radiation protection concepts developed by industry leaders in aerospace. In addition, NASA’s current prototype space radiation protection vest and storm shelter concept were tested using the newly drafted human factors assessment materials. Evaluation procedures and wearable garment technology were tested at Johnson Space Center (JSC) using a small sample of current NASA crewmembers for garment testing. Results for the garment analysis indicated that the current radiation vest ultimately did not hinder task performance or impede mobility. Results from the storm shelter analysis indicated that crew were able to construct the shelter within the time allotment without difficulty and limited reference to instruction materials. These data will be used to further develop wearable garment technology and storm shelter designs. Newly developed procedures will be used in future ground tests to further assess novel radiation protection concepts.

Hanson, Julie A.↗

Elucidating the Role of Carbon Conductive Additive in the Processing and Electrochemical Behavior of Surface-Modified Si Anodes

In the present work, we explore the impact of conducting carbon on the processing of silicon (Si)-rich electrodes, their resulting cycling performance, and parasitic side reactions. We employed three different carbon additives, Super C45 (carbon black), Super C65 (carbon black), and TIMCAL C-NERGY KS 6L (graphite), with varying sizes and morphologies to determine how these parameters influence the structure and the electrochemical behavior of the cast electrodes. Raman mapping indicates that the improved performance achieved using C45 can be explained by the homogeneous distribution of Si and carbon, enabling the formation of continuous electrical pathways throughout the electrode. Further, this finding aligns with the results of ζ potential measurements, which indicate that C45 can maintain more stable dispersions in N-methyl-2-pyrrolidone (NMP) compared with the other carbon additives. However, electrodes with C45 as the conducting agent exhibited increased parasitic side reactions, as evidenced by the leakage current obtained from voltage hold experiments. These side reactions can have adverse effects on the calendar life of the electrode. Furthermore, the Raman maps of the electrodes reveal heterogeneities in Si and carbon distribution with lower carbon content, especially with only 2% carbon. This drastically impacts the cyclability of the electrodes, with portions of the low-carbon electrodes that remain unable to undergo cycling even at slow rates (0.2 Ah g –1 ). Additionally, we found that slower formation rates are favored in the context of parasitic side reactions, although slower formation rates can potentially create thicker passivating films that could hinder Li + -ion transport. Therefore, we emphasize the need for an intricate balance in materials selection and cycling protocol for optimal electrode processing and electrochemical behavior.

25 ENERGY STORAGE↗

SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system safer than before.

60 APPLIED LIFE SCIENCES↗

HyMARC (Core): SNL Effort

Storage of hydrogen onboard vehicles is one of the critical technologies needed to create hydrogen-fueled transportation systems that can improve energy efficiency, resiliency, and energy independence reduce oil dependency. Stakeholders in developing hydrogen infrastructure (e.g., state governments, automotive original equipment manufacturers, station providers, and industrial gas suppliers) are currently focused on high-pressure storage at 350 bar and 700 bar, in part because no viable solid-phase storage material has emerged. Early-state research to develop foundational understanding of solid-state storage materials, including novel sorbents and highdensity hydrides, is of high importance because of their unique potential to meet all DOE Fuel Cell Technologies Office targets and deliver hydrogen with lower storage pressures and higher onboard densities. However, existing materials suffer from thermodynamic and kinetic limitations that prevent their application as practical H2 storage media. Sandia's overall objectives and responsibilities within HyMARC are to: (1) provide technical leadership to the Consortium at the Director level, as well as through leadership of Task 1 (Thermodynamics), Task 3 (Gas Surface Interactions), and Task 5 (Additives); (2) provide gas sorption and other property data required to develop and validate thermodynamic models of sorbents and metal hydride storage materials, including the effects of 350 bar and 700 bar H2 delivery pressures, serving as a resource for the consortium; (3) identify the structure, composition, and reactivity of gas surface and solid-solid hydride surfaces contributing to ratelimiting desorption and uptake; (4) provide metal hydrides and Metal-Organic Framework (MOF) sorbents in a variety of formats tailored for specific consortium tasks; (5) develop sample preparation methods and experimental protocols to enable facile use of the new characterization probes employed by the Consortium; (6) apply SNL multiscale codes to discover diffusion pathways and mechanisms of storage materials; and (7) elucidate the role of additives in promoting hydrogen storage reactions.

08 HYDROGEN↗