Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomedical data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Single- and multi-component chiral supraparticles as modular enantioselective catalysts

Nanoscale biological assemblies exemplified by exosomes, endosomes and capsids, play crucial roles in all living systems. Supraparticles (SP) from inorganic nanoparticles (NPs) replicate structural characteristics of these bioassemblies, but it is unknown whether they can mimic their biochemical functions. Here, we show that chiral ZnS NPs self-assemble into 70–100 nm SPs that display sub-nanoscale porosity associated with interstitial spaces between constituent NPs. Similarly to photosynthetic bacterial organelles, these SPs can serve as photocatalysts, enantioselectively converting L- or D-tyrosine (Tyr) into dityrosine (diTyr). Experimental data and molecular dynamic simulations indicate that the chiral bias of the photocatalytic reaction is associated with the chiral environment of interstitial spaces and preferential partitioning of enantiomers into SPs, which can be further enhanced by co-assembling ZnS with Au NPs. Besides replicating a specific function of biological nanoassemblies, these findings establish a path to enantioselective oxidative coupling of phenols for biomedical and other needs.

Science & Technology - Other Topics↗

SU-E-T-269: Differential Hazard Analysis For Conventional And New Linac Acceptance Testing Procedures

Purpose: New techniques and materials have recently been developed to expedite the conventional Linac Acceptance Testing Procedure (ATP). The new ATP method uses the Electronic Portal Imaging Device (EPID) for data collection and is presented separately. This new procedure is meant to be more efficient then conventional methods. While not clinically implemented yet, a prospective risk assessment is warranted for any new techniques. The purpose of this work is to investigate the risks and establish the pros and cons between the conventional approach and the new ATP method. Methods: ATP tests that were modified and performed with the EPID were analyzed. Five domain experts (Medical Physicists) comprised the core analysis team. Ranking scales were adopted from previous publications related to TG 100. The number of failure pathways for each ATP test procedure were compared as well as the number of risk priority numbers (RPN’s) greater than 100 were compared. Results: There were fewer failure pathways with the new ATP compared to the conventional, 262 and 556, respectively. There were fewer RPN’s > 100 in the new ATP compared to the conventional, 41 and 115. Failure pathways and RPN’s > 100 for individual ATP tests on average were 2 and 3.5 times higher in the conventional ATP compared to the new, respectively. The pixel sensitivity map of the EPID was identified as a key hazard to the new ATP procedure with an RPN of 288 for verifying beam parameters. Conclusion: The significant decrease in failure pathways and RPN’s >100 for the new ATP mitigates the possibilities of a catastrophic error occurring. The Pixel Sensitivity Map determining the response and inherent characteristics of the EPID is crucial as all data and hence results are dependent on that process. Grant from Varian Medical Systems Inc.

60 APPLIED LIFE SCIENCES↗

Knowledge gaps for neuromorphic ionic computing

BACKGROUND Neuromorphic computing, inspired by the human brain’s ability to process information efficiently, represents a transformative approach to computation. In this Review, we explore the emerging field of neuromorphic ionic computing, which leverages ionic conduction and coupling to mimic neural processes, and identify critical knowledge gaps that must be addressed to realize its full potential. A central theme of the discussion is energy efficiency, a challenge that is both a limitation and an opportunity for this technology. Although complementary metal-oxide semiconductor (CMOS)–based neuromorphic technologies have made strides in scaling to billions of neurons and are increasingly applied in artificial intelligence and numerical computing, they remain orders of magnitude behind the human brain in terms of connectivity and energy efficiency. Neuromorphic ionic computing promises to overcome these limitations by leveraging the distinct architectural and operational principles of the brain. Our brains achieve this energy efficiency by combining several key features: using the same network elements to store and process information; using an incredibly complex and massively interconnected three-dimensional (3D) network of locally active elements that enables sparsity, robustness in the presence of noise, adaptation, and life-long learning; computing at comparatively low voltage and frequency; and last, taking advantage of a plethora of ions and small molecules as information carriers. Here, we propose that ionic computing systems can take advantage of similar features to achieve substantial gains in energy efficiency. ADVANCES Since the first reports of neuromorphic ionic behavior in nanofluidic channels, we have witnessed an explosion of reports that used ionic devices to produce synaptomimetic behaviors. However, achieving the goals of ionic computing requires not only implementation of much more sophisticated device functionality but also overcoming fundamental barriers in materials science, device architecture, and system integration. Current ionic devices, even those incorporating state-of-the-art materials, still suffer from limited functionality and stability, which restrict their performance and increase energy demands. Developing new materials with enhanced ionic properties is essential to overcome these limitations. Similarly, the design of neuromorphic devices must evolve to leverage the particular advantages of ionic processes. Existing architectures often follow a single-information-carrier logic of conventional electronics or are constructed of mesoscale fluidics, failing to capitalize on the energy-efficient mechanisms inherent to ionic systems or implement the multiple-information-carrier paradigm. Current neuromorphic chips focus on large-scale networks of analog memory elements based on mechanisms such as charge trap (flash), filamentary, phase change, or spin, which are built on top of a network of artificial CMOS neurons. Although such prototype networks have achieved impressive performance, it is difficult to envision how they can implement the key features such as massive connectivity, sophisticated plasticity, adaptability, sparsity, and “multichromatic” computing. Although small-scale devices have demonstrated promising results, integrating them, maintaining energy efficiency, and implementing temperature control as systems grow in complexity and size to computationally relevant scale remain major hurdles. Furthermore, interfacing neuromorphic ionic devices with existing computing technologies presents technical and conceptual challenges that will require innovative approaches that combine insights from neuroscience, materials science, and engineering. OUTLOOK Despite these challenges, the potential impact of neuromorphic ionic computing is profound with potential applications ranging from artificial intelligence to robotics and beyond. We also argue that neuromorphic ionic computing systems should not, at least in the beginning, compete with CMOS technologies but rather should focus on applications that require extreme energy efficiency with chemical and/or biological compatibility, such as biomedical applications (for example, brain-computer interfaces), environmental monitoring, and agricultural and food applications. Ultimately, this Review highlights the crucial role of interdisciplinary collaboration in advancing the field. Neuromorphic ionic computing is not merely a technological innovation; it represents a substantial step toward sustainable computation, aligning with the growing demand for energy-conscious solutions in a world that is increasingly reliant on data and computation.

Neuromorphic↗

The biomedical challenges of space flight

Space medicine has evolved considerably through past U.S. missions. It has been proven that humans can live and work in space for long durations and that humans are integral to mission success. The space medicine program of the National Aeronautics and Space Administration (NASA) looks toward future long-duration missions. Its goal is to overcome the biomedical challenges associated with maintaining the safety, health, and optimum performance of astronauts and cosmonauts. This program investigates the health effects of adaptation to microgravity: the nature of their pathologies, the effects of microgravity on pathophysiology, and the alterations in pharmacodynamics and treatment. A critical capability in performing research is the monitoring of the health of all astronauts and of the spacecraft environment. These data support the evidence-based approach to space medicine, incorporating past studies of microgravity-related conditions and their terrestrial counterparts. This comprehensive approach will enable safe and effective exploration beyond low Earth orbit.

Mir Project↗

Medical and Transmission Vector Vocabulary Alignment with Schema.org

Available biomedical ontologies and knowledge bases currently lack formal and standards-based interconnections between disease, disease vector, and drug treatment vocabularies. The PNNL Medical Linked Dataset (PNNL-MLD) addresses this gap. This paper describes the PNNL-MLD, which provides a unified vocabulary and dataset of drug, disease, side effect, and vector transmission background information. Currently, the PNNL-MLD combines and curates data from the following research projects: DrugBank, DailyMed, Diseasome, DisGeNet, Wikipedia Infobox, Sider, and PharmGKB. The main outcomes of this effort are a dataset aligned to Schema.org, including a parsing framework, and extensible hooks ready for integration with selected medical ontologies. The PNNL-MLD enables researchers more quickly and easily to query distinct datasets. Future extensions to the PNNL-MLD will include Traditional Chinese Medicine, broader interlinks across genetic structures, a larger thesaurus of synonyms and hypernyms, explicit coding of diseases and drugs across research systems, and incorporating vector-borne transmission vocabularies.

research vocabulary, ontology, vocabulary alignmen↗

Is a Short-Interval Postradiation Mammogram Necessary After Conservative Surgery and Radiation in Breast Cancer?

Purpose: To examine, in a retrospective study, whether the initial posttreatment mammogram offers any benefit to patients. Methods and Materials: Patients were selected who had radiation after breast-conservation therapy from 1995 through 2005 and had follow-up mammography at University of California-Los Angeles (UCLA) within 1 year of completing radiotherapy. Results of the initial follow-up mammogram were analyzed to determine the yield of this initial mammogram. Results: Between 1995 and 2005, 408 patients treated with breast-conserving therapy and radiation had follow-up mammograms at UCLA within 1 year of completion of radiation. Median age at radiation completion was 56.9 years. Median interval between radiation and the initial mammogram was 3.1 months. Ten patients were found to have suspicious findings on the initial postradiation mammogram, prompting biopsy, but only 2 were found to have recurrent cancer. None of those lesions were palpable. In both cases the recurrences were ductal carcinoma in situ. Thus, the yield of the initial postoperative mammogram as compared with physical examination findings is estimated at 0.49 recurrences detected per 100 mammograms performed (95% confidence interval 0.059-1.759). Conclusions: The yield of the initial postradiation mammography at UCLA seems to be low, and only noninvasive carcinomas were found. Our data support the rationale to avoid the initial short-interval postradiation mammography and evaluate patients at 12 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of x-ray imaging technique for liquid screening at airport

X-ray imaging technology is a viable option to recognize flammable liquids for the purposes of aviation security. In this study, an X-ray imaging technology was developed whereby, the image viewing system was built with the use of a digital camera coupled with a gadolinium oxysulfide (GOS) fluorescent screen. The camera was equipped with a software for remote control setting of the camera via a USB cable which allows the images to be captured. The image was analysed to determine the average grey level using a software designed by Microsoft Visual Basic 6.0. The data was obtained for various densities of liquid thickness of 4.5 cm, 6.0 cm and 7.5 cm respectively for X-ray energies ranging from 70 to 200 kVp. In order to verify the reliability of the constructed calibration data, the system was tested with a few types of unknown liquids. The developed system could be conveniently employed for security screening in order to discriminate between a threat and an innocuous liquid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of a multi-atlas based method for segmentation of cardiac CTA data: a large-scale, multicenter, and multivendor study

Purpose: Computed tomography angiography (CTA) is increasingly used for the diagnosis of coronary artery disease (CAD). However, CTA is not commonly used for the assessment of ventricular and atrial function, although functional information extracted from CTA data is expected to improve the diagnostic value of the examination. In clinical practice, the extraction of ventricular and atrial functional information, such as stroke volume and ejection fraction, requires accurate delineation of cardiac chambers. In this paper, we investigated the accuracy and robustness of cardiac chamber delineation using a multiatlas based segmentation method on multicenter and multivendor CTA data. Methods: A fully automatic multiatlas based method for segmenting the whole heart (i.e., the outer surface of the pericardium) and cardiac chambers from CTA data is presented and evaluated. In the segmentation approach, eight atlas images are registered to a new patient's CTA scan. The eight corresponding manually labeled images are then propagated and combined using a per voxel majority voting procedure, to obtain a cardiac segmentation. Results: The method was evaluated on a multicenter/multivendor database, consisting of (1) a set of 1380 Siemens scans from 795 patients and (2) a set of 60 multivendor scans (Siemens, Philips, and GE) from different patients, acquired in six different institutions worldwide. A leave-one-out 3D quantitative validation was carried out on the eight atlas images; we obtained a mean surface-to-surface error of 0.94{+-}1.12 mm and an average Dice coefficient of 0.93 was achieved. A 2D quantitative evaluation was performed on the 60 multivendor data sets. Here, we observed a mean surface-to-surface error of 1.26{+-}1.25 mm and an average Dice coefficient of 0.91 was achieved. In addition to this quantitative evaluation, a large-scale 2D and 3D qualitative evaluation was performed on 1380 and 140 images, respectively. Experts evaluated that 49% of the 1380 images were very accurately segmented (below 1 mm error) and that 29% were accurately segmented (error between 1 and 3 mm), which demonstrates the robustness of the presented method. Conclusions: A fully automatic method for whole heart and cardiac chamber segmentation was presented and evaluated using multicenter/multivendor CTA data. The accuracy and robustness of the method were demonstrated by successfully applying the method to 1420 multicenter/multivendor data sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-36: A KWIC and Dirty Look at Dose Savings and Perfusion Metrics in Simulated CT Neuro Perfusion Exams

Purpose: CT neuro perfusion scans are one of the highest dose exams. Methods to reduce dose include decreasing the number of projections acquired per gantry rotation, however conventional reconstruction of such scans leads to sampling artifacts. In this study we investigated a projection view-sharing reconstruction algorithm used in dynamic MRI – “K-space Weighted Image Contrast” (KWIC) – applied to simulated perfusion exams and evaluated dose savings and impacts on perfusion metrics. Methods: A FORBILD head phantom containing simulated time-varying objects was developed and a set of parallel-beam CT projection data was created. The simulated scans were 60 seconds long, 1152 projections per turn, with a rotation time of one second. No noise was simulated. 5mm, 10mm, and 50mm objects were modeled in the brain. A baseline, “full dose” simulation used all projections and reduced dose cases were simulated by downsampling the number of projections per turn from 1152 to 576 (50% dose), 288 (25% dose), and 144 (12.5% dose). KWIC was further evaluated at 72 projections per rotation (6.25%). One image per second was reconstructed using filtered backprojection (FBP) and KWIC. KWIC reconstructions utilized view cores of 36, 72, 144, and 288 views and 16, 8, 4, and 2 subapertures respectively. From the reconstructed images, time-to-peak (TTP), cerebral blood flow (CBF) and the FWHM of the perfusion curve were calculated and compared against reference values from the full-dose FBP data. Results: TTP, CBF, and the FWHM were unaffected by dose reduction (to 12.5%) and reconstruction method, however image quality was improved when using KWIC. Conclusion: This pilot study suggests that KWIC preserves image quality and perfusion metrics when under-sampling projections and that the unique contrast weighting of KWIC could provided substantial dose-savings for perfusion CT scans. Evaluation of KWIC in clinical CT data will be performed in the near future. R01 EB014922, NCI Grant U01 CA181156 (Quantitative Imaging Network), and Tobacco Related Disease Research Project grant 22RT-0131.

60 APPLIED LIFE SCIENCES↗

Optimization of an on-board imaging system for extremely rapid radiation therapy

Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration deformation fields was computed. Results: By most global metrics (e.g., mean, median, and maximum pointwise distance), the high-resolution detector had the best performance but the medium-resolution detector was comparable. For all medium- and high-resolution detector registrations, mean error between the realistic and gold standard deformation fields was less than 4 mm. By pointwise metrics (e.g., tracking a small lesion), the high- and medium-resolution detectors performed similarly. For these detectors, the smallest error between the realistic and gold standard registrations was 0.6 mm and the largest error was 3.6 mm. Conclusions: The medium-resolution CT detector was selected as the best for an extremely rapid radiation therapy system. In essentially all test cases, data from this detector produced a significantly better registration than data from the low-resolution detector and a comparable registration to data from the high-resolution detector. The medium-resolution detector provides an appropriate compromise between registration accuracy and system cost.

60 APPLIED LIFE SCIENCES↗

The study of the structural properties of very low viscosity sodium alginate by small-angle neutron scattering

Sodium alginate is a linear polymer extract from brown algae and it is used in the biomedical, food, cosmetics and pharmaceutical industries as solution property modifiers and gelling agents. But despite the extensive studies of the alginate gelation process, still some fundamental questions remain unresolved. The fractal behavior of very low viscosity sodium alginate solutions and their influence on the critical gelation of alginate induced by Ca{sup 2+} ions were investigated using Small-Angle Neutron Scattering (SANS) measurements. SANS data are interpreted using both standard linear plots and the Beaucage model. The scattering intensity is dependent by alginate concentration and Ca{sup 2+} concentration. From a critical concentration of 1.0 % w/w our polymer swelled forming spherical structures with rough surfaces. Also the addition of the salt induces the collapse and the appearance of the aggregation and clusters formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the photoluminescent properties, scintillation behaviour and toxicological profile of various magnesium tungstate nanoscale motifs

We have synthesized several morphologies and crystal structures of MgWO 4 using a one-pot hydrothermal method, producing not only monoclinic stars and large nanoparticles but also triclinic wool balls and sub-10 nm nanoparticles. Herein we describe the importance of reaction parameters in demonstrating morphology control of as-prepared MgWO 4 . Moreover, we correlate structure and composition with the resulting photoluminescence and radioluminescence properties. Specifically, triclinic-phase samples yielded a photoluminescence emission of 421 nm, whereas monoclinic-phase materials gave rise to an emission maximum of 515 nm. The corresponding radioluminescence data were characterized by a broad emission peak, located at 500 nm for all samples. Annealing the wool balls and sub-10 nm particles to transform the crystal structure from a triclinic to a monoclinic phase yielded a radioluminescence (RL) emission signal that was two orders of magnitude greater than that of their unannealed counterparts. Finally, to confirm the practical utility of these materials for biomedical applications, a series of sub-10 nm particles, including as-prepared and annealed samples, were functionalized with biocompatible PEG molecules, and subsequently were found to be readily taken up by various cell lines as well as primary cultured hippocampal neurons with low levels of toxicity, thereby highlighting for the first time the potential of this particular class of metal oxides as viable and readily generated platforms for a range of biomedical applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Addressing uncertainty in genome-scale metabolic model reconstruction and analysis

The reconstruction and analysis of genome-scale metabolic models constitutes a powerful systems biology approach, with applications ranging from basic understanding of genotype-phenotype mapping to solving biomedical and environmental problems. However, the biological insight obtained from these models is limited by multiple heterogeneous sources of uncertainty, which are often difficult to quantify. Here we review the major sources of uncertainty and survey existing approaches developed for representing and addressing them. A unified formal characterization of these uncertainties through probabilistic approaches and ensemble modeling will facilitate convergence towards consistent reconstruction pipelines, improved data integration algorithms, and more accurate assessment of predictive capacity.

59 BASIC BIOLOGICAL SCIENCES↗

Conceptual design of a biological specimen holding facility

An all-important first step in the development of the Spacelab Life Science Laboratory is the design of the Biological Specimen Holding Facility (BSHF) which will provide accommodation for living specimens for life science research in orbit. As a useful tool in the understanding of physiological and biomedical changes produced in the weightless environment, the BSHF will enable biomedical researchers to conduct in-orbit investigations utilizing techniques that may be impossible to perform on human subjects. The results of a comprehensive study for defining the BSHF, description of its experiment support capabilities, and the planning required for its development are presented. Conceptual designs of the facility, its subsystems and interfaces with the Orbiter and Spacelab are included. Environmental control, life support and data management systems are provided. Interface and support equipment required for specimen transfer, surgical research, and food, water and waste storage is defined. New and optimized concepts are presented for waste collection, feces and urine separation and sampling, environmental control, feeding and watering, lighting, data management and other support subsystems.

Jackson, J. K.↗

NASA Tech Briefs, March 2008

Topics covered include: WRATS Integrated Data Acquisition System; Breadboard Signal Processor for Arraying DSN Antennas; Digital Receiver Phase Meter; Split-Block Waveguide Polarization Twist for 220 to 325 GHz; Nano-Multiplication-Region Avalanche Photodiodes and Arrays; Tailored Asymmetry for Enhanced Coupling to WGM Resonators; Disabling CNT Electronic Devices by Use of Electron Beams; Conical Bearingless Motor/Generators; Integrated Force Method for Indeterminate Structures; Carbon-Nanotube-Based Electrodes for Biomedical Applications; Compact Directional Microwave Antenna for Localized Heating; Using Hyperspectral Imagery to Identify Turfgrass Stresses; Shaping Diffraction-Grating Grooves to Optimize Efficiency; Low-Light-Shift Cesium Fountain without Mechanical Shutters; Magnetic Compensation for Second-Order Doppler Shift in LITS; Nanostructures Exploit Hybrid-Polariton Resonances; Microfluidics, Chromatography, and Atomic-Force Microscopy; Model of Image Artifacts from Dust Particles; Pattern-Recognition System for Approaching a Known Target; Orchestrator Telemetry Processing Pipeline; Scheme for Quantum Computing Immune to Decoherence; Spin-Stabilized Microsatellites with Solar Concentrators; Phase Calibration of Antenna Arrays Aimed at Spacecraft; Ring Bus Architecture for a Solid-State Recorder; and Image Compression Algorithm Altered to Improve Stereo Ranging.

Source record↗

Temporal RNA Integrity Analysis of Archived Spaceflight Biological Samples from ALSDA from 1991 to 2016

The purpose of this study is to assess the quality of spaceflight tissues stored in Ames Life Science Data Archive (ALSDA) freezers. Garnering information for downstream functional analysis such as generation of omics datasets from tissues is, in part, dependent on the state of sample preservation. To assess the viability of a select group of tissues, RNA integrity number (RIN) values were calculated for RNA extracted from rodent livers. Rat livers from Spacelab Life Sciences 1 (SLS-1) and mouse livers from Commercial Biomedical Test Module 3 (CBTM-3), Rodent Research 1 (RR1), and Rodent Research 3 (RR3) were tested. It was found that mean RIN values from CBTM3, RR1, and RR3 were suitable for downstream functional analysis (RIN greater than 5) while the mean RIN value for SLS-1 was not (RIN equal to 2.5 plus or minus 0.1). Information from this study could lay the foundation for future efforts in determining the types of assays that are most appropriate for different tissues in ALSDA freezers, which would maximize the scientific return on rare spaceflight samples.

ALSDA↗

Electrochemical characterization of a low modulus Ti-35.5Nb-7.3Zr-5.7Ta alloy in a simulated body fluid using EIS for biomedical applications

Electrochemical characterization of the low modulus Ti-35.5Nb-7.3Zr-5.7Ta beta alloy (TNZT) has been performed in phosphate buffer saline solution at 37 deg. C using the non destructive electrochemical impedance spectroscopy technique. Measurements were performed at various immersion intervals at the open circuit potential (OCP), which was also monitored with time. Results obtained for TNZT alloy have been compared with those for the commercially used Ti-6Al-4V mixed alloy (Ti64) and the commercially pure titanium (Ti2) alpha alloy. Potentiodynamic polarization was performed to supplement the data obtained from EIS analysis. The TNZT alloy exhibits a two time constant impedance response, whereas the Ti64 and Ti2 alloys display a one time constant behavior. Human fetal osteoblast cells show a better adhesion and a higher cell count for the TNZT alloy compared to the other two alloys. The present investigation is an effort to understand the correlation between the electrochemical, morphological and cellular characteristics of titanium alloys to qualify them for implant applications.

36 MATERIALS SCIENCE↗

SU-F-P-50: Performance Evaluation of Optically Stimulated Luminescence (OSL) NanoDots in Therapy and Imaging In-Vivo Dose Measurement During Patient Treatment

Purpose: This study was designed to evaluate the performance of optically stimulated Luminescence (OSL) nanoDots as in-vivo dosimeter. For the measurements of surface doses as well as scattered plus leakage doses, nanoDots were used during the setup verification as well as during the treatment delivery. Methods: For a total seven patients undergoing radiotherapy by volumetric modulated arc therapy, surface doses from image guidance and scattered plus leakage doses from treatment delivery were measured. Two sets of calibration curves were generated – one for therapy and another for imaging. Two different nanoDots were used for imaging and therapy doses. Imaging nanoDots were placed at the isocenter only at the time of CBCT and therapy nanoDots were placed at 25 cm away from the isocenter (either in cranial or in caudal direction) only at the time of treatment delivery. During the entire course, nanoDots were placed at the same measurement points. NanoDots were read after 15 minutes of their exposure. For the next fraction, nanoDots were corrected for the residual doses from the previous fractions. Results: Measured surface doses during imaging were 0.14±0.32 cGy, 0.11±0.04 cGy, 0.12±0.53 cGy, 0.04±0.02 cGy, 0.13±0.23 cGy, 0.11±0.43 cGy, 0.10±0.04 cGy with overall mean dose of 0.08±0.1 cGy. Measured doses during treatment delivery, indicative of scattered and leakage dose, were 0.84±0.43 cGy, 1.3±0.4 cGy, 1.4±0.4 cGy, 0.18±0.48 cGy, 0.78±0.29 cGy, 0.27±0.08 cGy, 0.78±0.07 cGy with overall mean dose of 0.61±1.3 cGy. Conclusion: This dosimeter can be used as supplementary unit to verify the doses. No change in the prescription is recommended based on nanoDots measurement. This study is on-going therefore we are presenting only mere number of patients. A large volume data will be presented after completion of the study with proper statistical analysis.

60 APPLIED LIFE SCIENCES↗