Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Venus pancake dome formation: Morphologic effects of a cooling-induced variable viscosity during emplacement

The distinctive steep-sided 'pancake' domes discovered in the Magellan images of Venus have morphologies that suggest formation by a single continuous emplacement of a high viscosity magma. A resemblance of the venusian domes to much smaller terrestrial rhyolite and dacite volcanic domes has prompted some authors to suggest that the domes on Venus also have high silica compositions and thus, high viscosities. However, viscosity is a function of crystallinity as well as silica content in a magma, and thus increases as a result of magmatic cooling. To investigate the effect of a cooling-induced viscosity increase on dome morphology, we have modeled the domes as radial viscous gravity currents that cool during emplacement. Various aspects of the investigation are discussed.

Sakimoto, S. E. H.↗

Icehouse Effect: A Selective Arctic Cooling Trend Current Models are Missing

The icehouse effect is a hypothesized climate feedback mechanism which could result in human-caused surface cooling trends in polar regions. Once understood in detail, it becomes apparent that these trends, which are discernable in the literature, but have been largely dismissed, do not conflict with the consensus assessment of the evidence, which infers century-scale Arctic warming. In fact, confirmation of the hypothesis would substantially strengthen the argument that there is a detectable human influence on today's climate. This apparent enigma is resolved only through careful attention to the detail of the hypothesis and the data supporting it. The posited surface cooling is entirely dependent on the existence of climate warming in layers capping the stable boundary layer. Also, the cooling is not pandemic, but is selective. It is readily revealed in properly sorted data by making use of the principles of micrometeorological similarity. Specifically, the cooling is manifest under a range of favorable turbulence conditions which can develop and disappear locally on time scales of minutes to hours because of the intrinsically intermittent nature of stable boundary layer turbulence. Because of the fine-scale nature of the processes which produce the cooling, modeling it is a difficult proposition. Vertical resolution on the order of 1 meter is required. Adequate models of intermittent surface fluxes coupled with radiation exchange do not currently exist, not as parameterizations for aggregated systems, nor in large eddy simulation (LES) models. This presentation will introduce the theory. An important testable null hypothesis emerges: the icehouse effect produces a unique signature or "fingerprint" which could not be produced by any other known process. The presence of this signature will be demonstrated using nearly all available Arctic temperature observations. Its aggregate effect is clearly found in Arctic monthly surface temperature trends when sorted by climatological stability. Using all available Arctic rawinsonde ascents - about 1.1 million profiles, "frozen moments" of the icehouse processes are captured in various states. Because turbulent time scales are so short in the stable boundary layer. each of these snapshots can be treated as independent -- their chronology is irrelevant. Micrometeorological similarity is invoked to reassemble the soundings into bins of similar stability and it is in a wide, coherent range of these stability bins where the cooling effect is revealed.

Wetzel, Peter J.↗

An experimental investigation to determine the effect of window cooling by mass injection for the Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment

The effect of mass injection on the shuttle infrared leeside temperature sensing (SILTS) pod window surfaces in reducing window heating and minimizing window lens radiation during the reentry data taking period is investigated. Heat transfer coefficients on and around the simulated windows and window cavities are determined. Heat transfer rates and window coolant flow rates are reported for the SILTS configuration. A comparison of two windows' geometries and their effects on the heat transfer rate is discussed and oil flow photographs are presented to indicate how mass injection affects the flow field near the SILTS window.

Bradley, P. F.↗

Effect of Interlayer Cooling Time, Constraint and Tool Path Strategy on Deformation of Large Components Made by Laser Metal Deposition with Wire

Laser metal deposition with wire (LMD-w) is a developing additive manufacturing (AM) technology that has a high deposition material rate and efficiency and is suitable for fabrication of large aerospace components. However, control of material properties, geometry, and residual stresses is needed before LMD-w technology can be widely adopted for the construction of critical structural components. In this study, we investigated the effect of interlayer cooling time, clamp constraints, and tool path strategy on part distortion and residual stresses in large-scale laser additive manufactured Ti-6Al-4V components using finite element method (FEM). The simulations were validated with the temperature and the distortion measurements obtained from a real LMD-w process. We found that a shorter interlayer cooling time, full clamping constraints on the build plates, and a bidirectional tool path with 180° rotation minimized part distortion and residual stresses and resulted in symmetric stress distribution.

36 MATERIALS SCIENCE↗

Beam-Beam Effects with Stochastic Cooling in the 2012 RHIC 100 GEV Heavy Ion Run

The 3-D stochastic cooling has been implemented in RHIC for the first time in the 2012 heavy ion run. In the U-U run, the U beam’s transverse emittances were cooled from initially about 13.5 mm.mrad down to 2.5 mm.mrad. The beam-beam parameters reached a maximum of -0.005. In the Cu-Au run, due to the unbalanced transverse beam sizes of the Cu and Au beams in the first several hours at the store, the Cu beam lifetime was significantly reduced by the beam-beam interaction. To maintain the Cu beam life-time and to maximize the integrated luminosity, we intentionally reduced the cooling rate for the Au beam until the Cu beam got cooled. In this article, we review the beam-beam effects in the 2012 RHIC heavy ion run and carry out numerical simulations to interpret the observations.

43 PARTICLE ACCELERATORS↗

Effects of the cooling system parameters on heat transfer and performance of the PAFC stack during transient operation

An experimental investigation for the effects of transient operation of a phosphoric acid fuel-cell stack on heat transfer and temperature distribution in the electrodes has been conducted. The proposed work utilized the experimental setup with modifications, which was designed and constructed under NASA Contract No. NCC-3-17(5). The experimental results obtained from this investigation and the mathematical model obtained under NASA Contract No. NCC3-17(4) after modifications, were utilized to develop mathematical models for transient heat transfer coefficient and temperature distribution in the electrode and to evaluate the performance of the cooling - system under unsteady state conditions. The empirical formulas developed were then implemented to modifying the developed computer code. Two incompressible coolants were used to study experimentally the effect of the thermophysical properties of the cool-ants on the transient heat transfer coefficient and the thermal contact resistance during start-up and shut-down processes. Coolant mass flow rates were verified from 16 to 88.2 Kg/hr during the transient process when the electrical power supply was gradually increased or decreased in the range (O to 3000 W/sq m). The effect of the thermal contact resistance with a range of stack pressure from O to 3500 KPa was studied.

Ridha, Rabi M. J.↗

A NEW APPROACH TO DETERMINE OPTICALLY THICK H{sub 2} COOLING AND ITS EFFECT ON PRIMORDIAL STAR FORMATION

We present a new method for estimating the H{sub 2} cooling rate in the optically thick regime in simulations of primordial star formation. Our new approach is based on the TreeCol algorithm, which projects matter distributions onto a spherical grid to create maps of column densities for each fluid element in the computational domain. We have improved this algorithm by using the relative gas velocities to weight the individual matter contributions with the relative spectral line overlaps, in order to properly account for the Doppler effect. We compare our new method to the widely used Sobolev approximation, which yields an estimate for the column density based on the local velocity gradient and the thermal velocity. This approach generally underestimates the photon escape probability because it neglects the density gradient and the actual shape of the cloud. We present a correction factor for the true line overlap in the Sobolev approximation and a new method based on local quantities, which fits the exact results reasonably well during the collapse of the cloud, with the error in the cooling rates always being less than 10%. Analytical fitting formulae fail at determining the photon escape probability after formation of the first protostar (error of ∼40%) because they are based on the assumption of spherical symmetry and therefore break down once a protostellar accretion disk has formed. Our method yields lower temperatures and hence promotes fragmentation for densities above ∼10{sup 10} cm{sup –3} at a distance of ∼200 AU from the first protostar. Since the overall accretion rates are hardly affected by the cooling implementation, we expect Pop III stars to have lower masses in our simulations, compared to the results of previous simulations that used the Sobolev approximation.

79 ASTRONOMY AND ASTROPHYSICS↗

Dispersion effect on the cooling rates

It is known that dispersion can redistribute the electron cooling rate between longitudinal and transverse planes. This note presents a simple analytical model to explain and estimate this redistribution effect. It shows that a small horizontal dispersion on ions can enhance horizontal cooling at the expense of longitudinal cooling rate. The electron dispersion is also beneficial to this effect.

43 PARTICLE ACCELERATORS↗

Effect of Different Cooling Rates on the Corrosion Behavior of High-Carbon Pearlitic Steel

The present work discusses the effect of pearlitic morphology on the corrosion behavior of high-carbon fully pearlitic steel in 3.5% NaCl solution. Four different types of pearlitic steels (furnace-cooled, as-received, air-cooled and forced-air-cooled) consisting of coarse, medium, fine and very fine microstructures, respectively, were tested. Electrochemical behavior of these steels was studied with the help of dynamic and linear polarization and AC impedance spectroscopic tests. The corrosion resistance improved with fineness of the microstructure in general. However, with further reduction in interlamellar spacing beyond a limit, the corrosion resistance reduced slightly. Formation of homogeneous distribution of microgalvanic cells between cementite and ferrite lamellae of fine pearlitic steel improved the corrosion resistance. However, entanglement of the lamellae of pearlite in very fine pearlitic structure as well as breaking of cementite lamellae due to finer pearlitic colonies was attributed to the higher corrosion of the forced-air-cooled steel as compared to the air-cooled steel.

36 MATERIALS SCIENCE↗

The Effect of Valve Cooling upon Maximum Permissible Engine Output as Limited by Knock

A Wright GR-1820-G200 cylinder was tested over a wide range of fuel-air ratios at maximum permissible power output as limited by knock with three different degrees of valve cooling. The valves used were stock valves (solid inlet valve and hollow sodium-cooled exhaust valve), hollow valves with no coolant, and hollow valves with flowing water as a coolant. Curves showing the variation in maximum permissible values of inlet-air pressure, indicated mean effective pressure, cylinder charge, and indicated specific fuel consumption with change in fuel-air ratio and valve cooling are shown. The use of valves cooled by a stream of water passing through their hollow interiors permitted indicated mean effective pressures 10 percent higher than the mean effective pressures permissible with stock valves when the engine was operated with fuel-air ratios from 0.055 to 0.065. Operation of the engine with lean mixtures with uncooled hollow valves resulted in power output below the output obtained with the stock valves. The data show an increase in maximum permissible indicated mean effective pressure due to cooling the valves, which averages only 2.1 percent with fuel-air ratios from 0.075 to 0.105.

Munger, Maurice↗

Investigation of Pore Size Effect On Spray Cooling Heat Transfer With Porous Tunnels

Previous studies have shown that spray cooling heat flux enhancement may be attained by using enhanced surface structures. However, most enhanced surface spray cooling studies have been limited to extended surfaces relative to the base surface. In this study, experiments were conducted to study the effects of pore size on spray cooling heat flux when using porous tunnels. The porous tunnels where placed sub-surface relative to the top of the heater block. Pores of varying size were machined in the top of the heater block leading into the sub-surface tunnels. Pore diameters varied between 0.25 mm and 1.0 mm. Each copper block had a projected cross-sectional area of 2.0 cm(sup 2). Measurements were also obtained on a heater block with a flat surface for baseline comparison purposes. A 2x2 nozzle array was used with PF-5060 as the working fluid. Thermal performance data was obtained under nominally degassed (chamber pressure of 41.4 kPa) conditions with a bulk fluid temperature of 20.5 "C. Results for both the study show that the highest critical heat flux (CHF) attained was 141 w/cm2 using pores 1.0 mm in diameter. This gave an enhancement of 75% relative to the flat surface case under nominally degassed conditions.

Silk, Eric A.↗

Surface Heater Fabrication Using Micro-Lithography for Transpiration Cooling Heat Transfer Coefficient Measurements

Abstract Transpiration cooling is able to provide more uniform coolant coverage than film cooling to effectively protect the component surface from contacting the hot gas. Due to numerous coolant ejection outlets within a small area at the target surface, the experimental thermo-fluid investigation on transpiration cooling becomes a significant challenge. Two classic methods to investigate film cooling, the steady-state foil heater method and the transient thermography technique, fail for transpiration cooling because the foil heater would block numerous coolant outlets, and the semi-infinite solid conduction model no longer holds for porous plates. In this study, a micro-lithography method to fabricate a silver coil pattern on top of the additively manufactured polymer porous media as the surface heater was proposed. The circuit was deliberately designed to cover the solid surface in a combination of series connection, and parallel connection to ensure the power in each unit cell area at the target surface was identical. With uniform heat flux generation, the steady-state tests were conducted to obtain distributions of a pair of parameters, adiabatic cooling effectiveness, and heat transfer coefficient (HTC). The results showed that the adiabatic cooling effectiveness could reach 0.65 with a blowing ratio lower than 0.5. Meanwhile, the heat transfer coefficient ratio (hf/h0) of transpiration cooling was close to 1 with a small blowing ratio at 0.125. A higher HTC ratio was observed for smaller pitch-to-diameter cases due to more turbulence intensity generated at the target surface.

Engineering↗

Crossflow effects on impingement cooling of a turbine vane

An air-cooled turbine vane was tested in a four-vane cascade. Heat transfer characteristics of the impingement cooled midchord region are reported. Experimental Nusselt numbers of six midchord locations are examined for the effect of crossflow and compared to those predicted by impingement correlations found in the literature.

Gauntner, J. W.↗

Effect of tropospheric aerosols upon atmospheric infrared cooling rates

The effect of tropospheric aerosols on atmospheric infrared cooling rates is investigated by the use of recent models of infrared gaseous absorption. A radiative model of the atmosphere that incorporates dust as an absorber and scatterer of infrared radiation is constructed by employing the exponential kernel approximation to the radiative transfer equation. Scattering effects are represented in terms of a single scattering albedo and an asymmetry factor. The model is applied to estimate the effect of an aerosol layer made of spherical quartz particles on the infrared cooling rate. Calculations performed for a reference wavelength of 0.55 microns show an increased greenhouse effect, where the net upward flux at the surface is reduced by 10% owing to the strongly enhanced downward emission. There is a substantial increase in the cooling rate near the surface, but the mean cooling rate throughout the lower troposphere was only 10%.

Harshvardhan, MR.↗

Effect of surface cooling and roughness on transition for the Shuttle Orbiter

An analysis of roughness-induced boundary-layer transition examines the sensitivity of the Orbiter boundary-layer transition criteria to surface cooling, to surface roughness, and to the assumed flow-field model. The experimental data were obtained using a 0.0175-scale Orbiter with surface roughness represented by misaligned heat-shield tiles for surface temperatures from 0.12 stagnation temperature (a value typical of entry conditions) to 0.42 stagnation temperature (a value typical of continuous-flow wind-tunnels). Tile misalignment had only a slight effect on the heat transfer and on the trasition locations for wall temperature = 0.42 stagnation temperature. Cooling the boundary layer caused the tile-induced disturbances to increase significantly, promoting premature transition. Correlation of the effects of the misalignment height and of surface cooling in promoting transition are presented and predictions are made for typical Orbiter entry conditions.

Bertin, J. J.↗

Effect of shocks on film cooling of a full scale turbojet exhaust nozzle having an external expansion surface

Experimental film cooling data obtained during exploratory testing with an axisymmetric plug nozzle having external expansion and installed on an afterburning turbojet engine in an altitude test facility is presented. The shocks and local hot gas stream conditions had a marked effect on film cooling effectiveness. An existing film cooling correlation was adequate at some operating conditions but inadequate at other conditions such as in separated flow regions resulting from shock boundary layer interactions.

Straight, D. M.↗

Thermally Effective and Efficient Cooling Technologies for Advanced Gas Turbine Systems

This report presents the research which has been undertaken under DOE grant DE-FE-0011875 as part of NETL’s UTSR (University Turbine System Research) Program. The experimental portion of this work was undertaken at the University of North Dakota (UND) under the direction of Dr. Forrest Ames. The computational work was undertaken at LSU (Louisiana State University), UM (University of Memphis), and at IIT (Illinois Institute of Technology) under the direction of Dr. Sumanta Acharya. The research program was organized into a four phase program which included: 1) development of a FDA/FEA (finite difference analysis/finite element analysis) cooling model, 2) experimental/computational investigation of appropriate internal cooling methods, 3) experimental/computational investigation of external heat transfer and film cooling, 4) development of an enhanced FDA/FEA model along with the development of a warm cascade test for comparison purposes. The experimental work at UND included research on both internal cooling methods and external heat transfer. The internal cooling work included the design and testing of multiple variable hole-size “incremental impingement” configurations along with testing of two converging rounded diamond pedestal arrays for the trailing edge region. The external heat transfer work included the building of a large scale cascade facility to test a vane design with a large leading edge and an aft loaded suction surface. UND has acquired both midspan and full suction surface heat transfer measurements as well as prepared for film cooling measurements under the grant. LSU/UM/IIT has developed and conducted wall resolved LES computations for the incremental impingement geometries and provided rational understanding of the effect of hole sizes and their distributions. Additionally they have provided design correlations for the incremental impingement heat transfer coefficients. They have also developed LES methods to predict flow through film cooling plenums, which have pedestals along with the development of slot film cooling downstream from the plenums. Additionally, they have developed wall resolved LES to predict vane surface heat transfer including bypass transition without the use of a transition model. Through these simulations they provide understanding of the aerodynamic and surface heat transfer behavior under a range of influences such as freestream turbulence. The present study has produced some very useful research outcomes.

01 COAL, LIGNITE, AND PEAT↗

Collective Effects in Muon Ionization Cooling

In this presentation, we will overview the concept of muon ionization cooling, and propose a new cooling formula including collective effects which is produced by beam-induced plasma in absorbers.

Yonehara, Katsuya [Fermilab] (ORCID:00000002544041↗