Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polarization Characteristics of Zebra Patterns in Type IV Solar Radio Bursts

The polarization characteristics of zebra patterns (ZPs) in type IV solar bursts were studied. We analyzed 21 ZP events observed by the Assembly of Metric-band Aperture Telescope and Real-time Analysis System between 2010 and 2015 and identified the following characteristics: a degree of circular polarization (DCP) in the range of 0%–70%, a temporal delay of 0–70 ms between the two circularly polarized components (i.e., the right- and left-handed components), and dominant ordinary-mode emission in about 81% of the events. For most events, the relation between the dominant and delayed components could be interpreted in the framework of fundamental plasma emission and depolarization during propagation, though the values of DCP and delay were distributed across wide ranges. Furthermore, it was found that the DCP and delay were positively correlated (rank correlation coefficient R = 0.62). As a possible interpretation of this relationship, we considered a model based on depolarization due to reflections at sharp density boundaries assuming fundamental plasma emission. The model calculations of depolarization including multiple reflections and group delay during propagation in the inhomogeneous corona showed that the DCP and delay decreased as the number of reflections increased, which is consistent with the observational results. The dispersive polarization characteristics could be explained by the different numbers of reflections causing depolarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting Late Effects of Pelvic Radiotherapy: Is There a Better Approach?

Purpose: Significant chronic symptoms following pelvic radiotherapy occur more frequently than commonly realized. Predictive factors for the development of late symptoms are poorly defined. Moderate sustained acute (cumulative) toxicity might predict severe late effects better than peak reaction. Methods and Materials: To determine prospectively whether peak or cumulative gastrointestinal (GI) acute symptoms better predict late symptoms in patients receiving pelvic radiotherapy. Symptom scores were measured weekly from the start of radiotherapy, and at 1 year using the Modified Inflammatory Bowel Disease Questionnaire-Bowel subset. The possible prognostic impact of patient-related factors was explored. Results: Three hundred and eight patients were recruited. 100 were excluded due to lack of follow-up data at one year resulting from death, too ill, stoma, relapsed, non-response or withdrawal. A further 15 were excluded for incomplete data, leaving 193 patients with evaluable data. Of these, 28 had GI, 101 urological, and 64 gynecological cancers. Patients' median age was 65 years (range, 23-82), and they were treated with median 60 Gy dose for a median of 6 weeks. Univariate analysis revealed a significant association between cumulative acute symptom scores and scores at 1 year (p < 0.001), which was dose-independent (p < 0.001). Acute peak and 1-year scores were not associated (p = 0.431). The correlation coefficient between cumulative acute symptoms and symptoms at 1 year was 0.367 and for peak acute symptoms was weaker at 0.057. Patients with an abnormal body mass index and current smokers were more likely to experience worse symptoms at 1 year. Conclusion: Cumulative acute symptoms are more predictive of late symptoms than peak acute changes in score. This association is independent of the radiotherapy dose delivered and is suggestive of a consequential late effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparative Study of the Hypoxia PET Tracers [{sup 18}F]HX4, [{sup 18}F]FAZA, and [{sup 18}F]FMISO in a Preclinical Tumor Model

Purpose: Several individual clinical and preclinical studies have shown the possibility of evaluating tumor hypoxia by using noninvasive positron emission tomography (PET). The current study compared 3 hypoxia PET tracers frequently used in the clinic, [{sup 18}F]FMISO, [{sup 18}F]FAZA, and [{sup 18}F]HX4, in a preclinical tumor model. Tracer uptake was evaluated for the optimal time point for imaging, tumor-to-blood ratios (TBR), spatial reproducibility, and sensitivity to oxygen modification. Methods and Materials: PET/computed tomography (CT) images of rhabdomyosarcoma R1-bearing WAG/Rij rats were acquired at multiple time points post injection (p.i.) with one of the hypoxia tracers. TBR values were calculated, and reproducibility was investigated by voxel-to-voxel analysis, represented as correlation coefficients (R) or Dice similarity coefficient of the high-uptake volume. Tumor oxygen modifications were induced by exposure to either carbogen/nicotinamide treatment or 7% oxygen breathing. Results: TBR was stabilized and maximal at 2 hours p.i. for [{sup 18}F]FAZA (4.0 ± 0.5) and at 3 hours p.i. for [{sup 18}F]HX4 (7.2 ± 0.7), whereas [{sup 18}F]FMISO showed a constant increasing TBR (9.0 ± 0.8 at 6 hours p.i.). High spatial reproducibility was observed by voxel-to-voxel comparisons and Dice similarity coefficient calculations on the 30% highest uptake volume for both [{sup 18}F]FMISO (R = 0.86; Dice coefficient = 0.76) and [{sup 18}F]HX4 (R = 0.76; Dice coefficient = 0.70), whereas [{sup 18}F]FAZA was less reproducible (R = 0.52; Dice coefficient = 0.49). Modifying the hypoxic fraction resulted in enhanced mean standardized uptake values for both [{sup 18}F]HX4 and [{sup 18}F]FAZA upon 7% oxygen breathing. Only [{sup 18}F]FMISO uptake was found to be reversible upon exposure to nicotinamide and carbogen. Conclusions: This study indicates that each tracer has its own strengths and, depending on the question to be answered, a different tracer can be put forward.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractal analysis of the dark matter and gas distributions in the Mare-Nostrum universe

We develop a method of multifractal analysis of N-body cosmological simulations that improves on the customary counts-in-cells method by taking special care of the effects of discreteness and large scale homogeneity. The analysis of the Mare-Nostrum simulation with our method provides strong evidence of self-similar multifractal distributions of dark matter and gas, with a halo mass function that is of Press-Schechter type but has a power-law exponent -2, as corresponds to a multifractal. Furthermore, our analysis shows that the dark matter and gas distributions are indistinguishable as multifractals. To determine if there is any gas biasing, we calculate the cross-correlation coefficient, with negative but inconclusive results. Hence, we develop an effective Bayesian analysis connected with information theory, which clearly demonstrates that the gas is biased in a long range of scales, up to the scale of homogeneity. However, entropic measures related to the Bayesian analysis show that this gas bias is small (in a precise sense) and is such that the fractal singularities of both distributions coincide and are identical. We conclude that this common multifractal cosmic web structure is determined by the dynamics and is independent of the initial conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Possibility of efficient generation of multiphoton entangled states using a one-dimensional nonlinear photonic crystal

A rigorous quantum theory for the generation of multiphoton entangled states based on two consecutive three-frequency interactions of waves in a one-dimensional nonlinear photonic crystal is developed using the field expansion and differentiation methods. The three-photon correlation coefficient and the average photon numbers generated in the structure are calculated. All order expansion terms are included in the calculation. The generation conditions for multiphoton entangled states in such a structure are also analyzed. It is shown that the created photons in the present structures obey the super-Poisson statistics at the interacting frequencies and are in a multiparticle entangled state. This means the nonlinear photonic crystal can be applied as a highly efficient source of an entangled multiphoton for highly integrated all-optical circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VARIABILITY-INDUCED MOTION IN KEPLER DATA

Variability-induced motion (VIM) is an observable effect in simultaneous astrometric and photometric measurements caused by brightness variation in one of the components of a double source or blended image, which manifests itself as a strongly correlated shift of the optical photocenter. We have processed the entire collection of Kepler long-cadence light curve data, looking for correlated signals in astrometry and photometry on the time basis of a quarter-year. Limiting the VIM correlation coefficient to 0.3, VIM events are detected for 129,525 Kepler stars in at least one quarter. Of 7305 Kepler objects of interest , 4440 are detected as VIM at least once. Known variable stars and resolved double stars have elevated rates of VIM detection. Confident VIM occurrences are found for stars with suggested superflare events, indicating possible signal contamination. We present a complete catalog of all quarterly VIM detections. This catalog should be checked for such astrophysically significant events as transits of exoplanets, new eclipsing stars, and superflares of solar-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

On the variability of the Priestley‐Taylor coefficient over water bodies

Abstract Deviations in the Priestley‐Taylor (PT) coefficient α PT from its accepted 1.26 value are analyzed over large lakes, reservoirs, and wetlands where stomatal or soil controls are minimal or absent. The data sets feature wide variations in water body sizes and climatic conditions. Neither surface temperature nor sensible heat flux variations alone, which proved successful in characterizing α PT variations over some crops, explain measured deviations in α PT over water. It is shown that the relative transport efficiency of turbulent heat and water vapor is key to explaining variations in α PT over water surfaces, thereby offering a new perspective over the concept of minimal advection or entrainment introduced by PT. Methods that allow the determination of α PT based on low‐frequency sampling (i.e., 0.1 Hz) are then developed and tested, which are usable with standard meteorological sensors that filter some but not all turbulent fluctuations. Using approximations to the Gram determinant inequality, the relative transport efficiency is derived as a function of the correlation coefficient between temperature and water vapor concentration fluctuations ( R Tq ). The proposed approach reasonably explains the measured deviations from the conventional α PT = 1.26 value even when R Tq is determined from air temperature and water vapor concentration time series that are Gaussian‐filtered and subsampled to a cutoff frequency of 0.1 Hz. Because over water bodies, R Tq deviations from unity are often associated with advection and/or entrainment, linkages between α PT and R Tq offer both a diagnostic approach to assess their significance and a prognostic approach to correct the 1.26 value when using routine meteorological measurements of temperature and humidity.

Assouline, Shmuel↗

Rotation of the optical polarization angle associated with the 2008 γ-ray flare of blazar W Comae

An R-band photopolarimetric variability analysis of the TeV bright blazar W Comae between 2008 February 28 and 2013 May 17 is presented. The source showed a gradual tendency to decrease its mean flux level with a total change of 3 mJy. A maximum and minimum brightness states in the R band of 14.25 ± 0.04 and 16.52 ± 0.1 mag, respectively, were observed, corresponding to a maximum variation of ΔF = 5.40 mJy. We estimated a minimum variability timescale of Δt = 3.3 days. A maximum polarization degree P = 33.8% ± 1.6%, with a maximum variation of ΔP = 33.2%, was found. One of our main results is the detection of a large rotation of the polarization angle from 78° to 315° (Δθ ∼ 237°) that coincides in time with the γ-ray flare observed in 2008 June. This result indicates that both optical and γ-ray emission regions could be co-spatial. During this flare, a correlation between the R-band flux and polarization degree was found with a correlation coefficient of r {sub F} {sub –} {sub p} = 0.93 ± 0.11. From the Stokes parameters, we infer the existence of two optically thin synchrotron components that contribute to the polarized flux. One of them is stable with a constant polarization degree of 11%. Assuming a shock-in jet model during the 2008 flare, we estimated a maximum Doppler factor δ {sub D} ∼ 27 and a minimum of δ {sub D} ∼ 16; a minimum viewing angle of the jet ∼2.°0; and a magnetic field B ∼ 0.12 G.

79 ASTRONOMY AND ASTROPHYSICS↗

Temporal subtraction in chest radiography: Mutual information as a measure of image quality

Purpose: Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or ''lung mask,'' of a previous radiographic image to align with the current image. The gray levels of every pixel in the current image are subtracted from the gray levels of the corresponding pixels in the warped previous image to form a temporal subtraction image. While temporal subtraction images effectively enhance areas of pathologic change, misregistration of the images can mislead radiologists by obscuring the interval change or by creating artifacts that mimic change. The purpose of this study was to investigate the utility of mutual information computed between two registered radiographic chest images as a metric for distinguishing between clinically acceptable and clinically unacceptable temporal subtraction images.Methods: A radiologist subjectively rated the image quality of 138 temporal subtraction images using a 1 (poor) to 5 (excellent) scale. To objectively assess the registration accuracy depicted in the temporal subtraction images, which is the main factor that affects the quality of these images, mutual information was computed on the two constituent registered images prior to their subtraction to generate a temporal subtraction image. Mutual information measures the joint entropy of the current image and the warped previous image, yielding a higher value when the gray levels of spatially matched pixels in each image are consistent. Mutual information values were correlated with the radiologist's subjective ratings. To improve this correlation, mutual information was computed from a spatially limited lung mask, which was cropped from the bottom by 10%-60%. Additionally, the number of gray-level values used in the joint entropy histogram was varied. The ability of mutual information to predict the clinical acceptability of a temporal subtraction image was evaluated through receiver operating characteristic (ROC) analysis. Results: The mean correlation coefficient obtained between mutual information computed on constituent images and the subjective rating of temporal subtraction image quality was 0.785. ROC analysis yielded an average A{sub z} value of 0.852 for the ability of mutual information to distinguish between temporal subtraction images of clinically acceptable and clinically unacceptable quality. Conclusions: The results of this study establish a relationship between mutual information and temporal subtraction registration accuracy and demonstrate the ability of mutual information to objectively indicate the presence of misregistration artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parametric Thermal Soak Model for Earth Entry Vehicles

The analysis and design of an Earth Entry Vehicle (EEV) is multidisciplinary in nature, requiring the application many disciplines. An integrated tool called Multi Mission System Analysis for Planetary Entry Descent and Landing or M-SAPE is being developed as part of Entry Vehicle Technology project under In-Space Technology program. Integration of a multidisciplinary problem is a challenging task. Automation of the execution process and data transfer among disciplines can be accomplished to provide significant benefits. Thermal soak analysis and temperature predictions of various interior components of entry vehicle, including the impact foam and payload container are part of the solution that M-SAPE will offer to spacecraft designers. The present paper focuses on the thermal soak analysis of an entry vehicle design based on the Mars Sample Return entry vehicle geometry and discusses a technical approach to develop parametric models for thermal soak analysis that will be integrated into M-SAPE. One of the main objectives is to be able to identify the important parameters and to develop correlation coefficients so that, for a given trajectory, can estimate the peak payload temperature based on relevant trajectory parameters and vehicle geometry. The models are being developed for two primary thermal protection (TPS) materials: 1) carbon phenolic that was used for Galileo and Pioneer Venus probes and, 2) Phenolic Impregnated Carbon Ablator (PICA), TPS material for Mars Science Lab mission. Several representative trajectories were selected from a very large trade space to include in the thermal analysis in order to develop an effective parametric thermal soak model. The selected trajectories covered a wide range of heatload and heatflux combinations. Non-linear, fully transient, thermal finite element simulations were performed for the selected trajectories to generate the temperature histories at the interior of the vehicle. Figure 1 shows the finite element model that was used for the simulations. The results indicate that it takes several hours for the thermal energy to soak into the interior of the vehicle and achieve maximum payload temperatures. In addition, a strong correlation between the heatload and peak payload container temperature is observed that will help establishing the parametric thermal soak model.

Agrawal, Parul↗

SU-E-T-422: Fast Analytical Beamlet Optimization for Volumetric Intensity-Modulated Arc Therapy

Purpose: To implement a fast optimization algorithm on CPU/GPU heterogeneous computing platform and to obtain an optimal fluence for a given target dose distribution from the pre-calculated beamlets in an analytical approach. Methods: The 2D target dose distribution was modeled as an n-dimensional vector and estimated by a linear combination of independent basis vectors. The basis set was composed of the pre-calculated beamlet dose distributions at every 6 degrees of gantry angle and the cost function was set as the magnitude square of the vector difference between the target and the estimated dose distribution. The optimal weighting of the basis, which corresponds to the optimal fluence, was obtained analytically by the least square method. Those basis vectors with a positive weighting were selected for entering into the next level of optimization. Totally, 7 levels of optimization were implemented in the study.Ten head-and-neck and ten prostate carcinoma cases were selected for the study and mapped to a round water phantom with a diameter of 20cm. The Matlab computation was performed in a heterogeneous programming environment with Intel i7 CPU and NVIDIA Geforce 840M GPU. Results: In all selected cases, the estimated dose distribution was in a good agreement with the given target dose distribution and their correlation coefficients were found to be in the range of 0.9992 to 0.9997. Their root-mean-square error was monotonically decreasing and converging after 7 cycles of optimization. The computation took only about 10 seconds and the optimal fluence maps at each gantry angle throughout an arc were quickly obtained. Conclusion: An analytical approach is derived for finding the optimal fluence for a given target dose distribution and a fast optimization algorithm implemented on the CPU/GPU heterogeneous computing environment greatly reduces the optimization time.

60 APPLIED LIFE SCIENCES↗

PULSATION PERIOD VARIATIONS IN THE RRc LYRAE STAR KIC 5520878

Learned et al. proposed that a sufficiently advanced extra-terrestrial civilization may tickle Cepheid and RR Lyrae variable stars with a neutrino beam at the right time, thus causing them to trigger early and jogging the otherwise very regular phase of their expansion and contraction. This would turn these stars into beacons to transmit information throughout the galaxy and beyond. The idea is to search for signs of phase modulation (in the regime of short pulse duration) and patterns, which could be indicative of intentional, omnidirectional signaling. We have performed such a search among variable stars using photometric data from the Kepler space telescope. In the RRc Lyrae star KIC 5520878, we have found two such regimes of long and short pulse durations. The sequence of period lengths, expressed as time series data, is strongly autocorrelated, with correlation coefficients of prime numbers being significantly higher (p = 99.8%). Our analysis of this candidate star shows that the prime number oddity originates from two simultaneous pulsation periods and is likely of natural origin. Simple physical models elucidate the frequency content and asymmetries of the KIC 5520878 light curve. Despite this SETI null result, we encourage testing of other archival and future time-series photometry for signs of modulated stars. This can be done as a by-product to the standard analysis, and can even be partly automated.

79 ASTRONOMY AND ASTROPHYSICS↗

Small-scale conformity of the Virgo Cluster galaxies

We investigate the small-scale conformity in color between bright galaxies and their faint companions in the Virgo Cluster. Cluster member galaxies are spectroscopically determined using the Extended Virgo Cluster Catalog and the Sloan Digital Sky Survey Data Release 12. We find that the luminosity-weighted mean color of faint galaxies depends on the color of adjacent bright galaxy as well as on the cluster-scale environment (gravitational potential index). From this result for the entire area of the Virgo Cluster, it is not distinguishable whether the small-scale conformity is genuine or if it is artificially produced due to cluster-scale variation of galaxy color. To disentangle this degeneracy, we divide the Virgo Cluster area into three sub-areas so that the cluster-scale environmental dependence is minimized: A1 (central), A2 (intermediate), and A3 (outermost). We find conformity in color between bright galaxies and their faint companions (color–color slope significance S ∼ 2.73σ and correlation coefficient cc∼0.50) in A2, where the cluster-scale environmental dependence is almost negligible. On the other hand, the conformity is not significant or very marginal (S ∼ 1.75σ and cc∼0.27) in A1. The conformity is not significant either in A3 (S ∼ 1.59σ and cc∼0.44), but the sample size is too small in this area. These results are consistent with a scenario in which the small-scale conformity in a cluster is a vestige of infallen groups and these groups lose conformity as they come closer to the cluster center.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of baryon acoustic oscillations in the Lyman-α forest fluctuations in BOSS data release 9

We use the Baryon Oscillation Spectroscopic Survey (BOSS) Data Release 9 (DR9) to detect and measure the position of the Baryonic Acoustic Oscillation (BAO) feature in the three-dimensional correlation function in the Lyman-α flux fluctuations at a redshift z{sub eff} = 2.4. The feature is clearly detected at significance between 3 and 5 sigma (depending on the broadband model and method of error covariance matrix estimation) and is consistent with predictions of the standard ΛCDM model. We assess the biases in our method, stability of the error covariance matrix and possible systematic effects. We fit the resulting correlation function with several models that decouple the broadband and acoustic scale information. For an isotropic dilation factor, we measure 100 × (α{sub iso} − 1) = −1.6{sup +2.0+4.3+7.4}{sub −2.0−4.1−6.8} (stat.) ±1.0 (syst.) (multiple statistical errors denote 1,2 and 3 sigma confidence limits) with respect to the acoustic scale in the fiducial cosmological model (flat ΛCDM with Ω{sub m} = 0.27, h = 0.7). When fitting separately for the radial and transversal dilation factors we find marginalised constraints 100 × (α{sub ||} − 1) = −1.3{sup +3.5+7.6+12.3}{sub −3.3−6.7−10.2} (stat.) ±2.0 (syst.) and 100 × (α{sub p}erpendicular − 1) = −2.2{sup +7.4+17}{sub −7.1−15} (stat.) ±3.0 (syst.). The dilation factor measurements are significantly correlated with cross-correlation coefficient of ∼ −0.55. Errors become significantly non-Gaussian for deviations over 3 standard deviations from best fit value. Because of the data cuts and analysis method, these measurements give tighter constraints than a previous BAO analysis of the BOSS DR9 Lyman-α sample, providing an important consistency test of the standard cosmological model in a new redshift regime.

79 ASTRONOMY AND ASTROPHYSICS↗

THE PREDICTIVE POWER OF OHL'S PRECURSOR METHOD

Using linear regression techniques and correlation analysis, the predictive power of Ohl's method is shown to satisfy one of the following relationships. Either a successful prediction of cycle amplitude can be obtained if the correlation between the minimum aa geomagnetic index in the declining phase of a solar cycle and the sunspot maximum of the succeeding cycle becomes stronger, or the prediction error exceeds the expected prediction error if the correlation becomes weaker. The correlation coefficient has a declining secular variation, which leads to a weakening trend in predictive power, as well as a 44 year periodicity that may explain why the prediction method did not work well for solar cycle 23. As this finding only emerged twice in the {approx}100 year period studied, this 44 year periodicity may occur with a degree of uncertainty and may therefore need to be checked in the future. Two quantities, namely a prediction parameter and the prediction index, are proposed to analyze predictive power. Using the above properties, the success probability of a prediction result can be analyzed in advance.

79 ASTRONOMY AND ASTROPHYSICS↗

Satellite passive microwave rain rate measurement over croplands during spring, summer and fall

Rain-rate algorithms for spring, summer and fall that have been developed from comparisons between the brightness temperatures measured by the Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) and rain rates derived from operational WSR-57 radars over land are described. Data were utilized from a total of 25 SMMR passes and 234 radars, resulting in about 12,000 observations of about 1600 sq/km areas. Multiple correlation coefficients of 0.63, 0.80 and 0.75 are achieved for the spring, summer and fall algorithms, respectively. Most of this information is in the form of multifrequency contrast in brightness temperature, which is interpreted as a measurement of the degree to which the land-emitted radiation is attenuated by the rain systems. The SMMR 37-GHz channel has more information on rain rate than any other channel. By combining the lower frequency channels with the 37-GHz observations, variations in land and precipitation thermometric temperatures can be removed, leaving rain attenuation as the major effect on brightness temperature. Polarization screening at 37 GHz is found to be sufficient to screen out cases of wet ground, which is only important when the ground is relatively vegetation free. Heavy rain cases are found to be significant part of the algorithms' success, because of the strong microwve signatures (low-brightness temperatures) that result from the presence of precipitation-sized ice in the upper portions of heavily precipitating storms. If IR data are combined with the summer microwave data, an improved (0.85) correlation with radar rain rates is achieved.

Spencer, R. W.↗

A theoretical method to compute sequence dependent configurational properties in charged polymers and proteins

A general formalism to compute configurational properties of proteins and other heteropolymers with an arbitrary sequence of charges and non-uniform excluded volume interaction is presented. A variational approach is utilized to predict average distance between any two monomers in the chain. The presented analytical model, for the first time, explicitly incorporates the role of sequence charge distribution to determine relative sizes between two sequences that vary not only in total charge composition but also in charge decoration (even when charge composition is fixed). Furthermore, the formalism is general enough to allow variation in excluded volume interactions between two monomers. Model predictions are benchmarked against the all-atom Monte Carlo studies of Das and Pappu [Proc. Natl. Acad. Sci. U. S. A. 110, 13392 (2013)] for 30 different synthetic sequences of polyampholytes. These sequences possess an equal number of glutamic acid (E) and lysine (K) residues but differ in the patterning within the sequence. Without any fit parameter, the model captures the strong sequence dependence of the simulated values of the radius of gyration with a correlation coefficient of R{sup 2} = 0.9. The model is then applied to real proteins to compare the unfolded state dimensions of 540 orthologous pairs of thermophilic and mesophilic proteins. The excluded volume parameters are assumed similar under denatured conditions, and only electrostatic effects encoded in the sequence are accounted for. With these assumptions, thermophilic proteins are found—with high statistical significance—to have more compact disordered ensemble compared to their mesophilic counterparts. The method presented here, due to its analytical nature, is capable of making such high throughput analysis of multiple proteins and will have broad applications in proteomic studies as well as in other heteropolymeric systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗