Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Volumetrics of Hydrogen Storage by Physical Adsorption

Physical adsorption remains a promising method for achieving fast, reversible hydrogen storage at both ambient and cryogenic conditions. Research in this area has recently shifted to focus primarily on the volumetric (H 2 stored/delivered per volume) gains achieved within an adsorptive storage system over that of pure H 2 compression; however, the methodology for estimating a volumetric stored or delivered amount requires several assumptions related to the ultimate packing of the adsorbent material into an actual storage system volume. In this work, we critically review the different assumptions commonly employed, and thereby categorize and compare the volumetric storage and delivery across numerous different porous materials including benchmark metal-organic frameworks, porous carbons, and zeolites. In several cases, there is a significant gain in both storage and delivery by the addition of an adsorbent to the high-pressure H 2 storage system over that of pure compression, even at room temperature. Lightweight, low-density materials remain the optimal adsorbents at low temperature, while higher density, open metal-containing frameworks are necessary for high-density room temperature storage and delivery.

08 HYDROGEN↗

Space Launch System and Missions to Near Rectilinear Halo Orbits

The first major evolution of NASA’s Space Launch System (SLS) will begin its flights starting in the mid-2020’s. This new configuration, called Block 1B, replaces the Interim Cryogenic Propulsion Stage with a larger Exploration Upper Stage (EUS). The additional capability provided by the new upper stage will allow SLS to send heavier payloads into deep space. One destination of interest to the SLS program is called a Near Rectilinear Halo Orbit (NRHO). This is a type of lunar orbit with multiple advantages for deep space exploration. These benefits include Earth/lunar access, low station-keeping requirements, and high communication potential with Earth. Therefore, it is a leading candidate for the proposed Lunar Orbital Platform-Gateway (LOP-G). This paper will provide a detailed assessment of the SLS Block 1B requirements and capabilities for sending payloads to an NRHO. Analysts at Marshall Space Flight Center are producing a multi-year mission availability scan for the SLS Block 1B configuration to a predefined NRHO orbit. The analysis produces an optimized trajectory for each day of the scan window. A maximized payload and minimized propellant requirement are determined for each day. All maneuvers from launch to the end of the Trans-Lunar-Injection (TLI) are being modeled as finite burns. Injections into an NRHO are being modeled as impulsive maneuvers. The payload element is arbitrary, but includes sufficient mass to represent a large habitat or propulsion module. The resulting parameters of payload capability, delta-v requirements, and launch windows length vary over the course of the scan. Many launch days in the scan are eliminated in post-processing as they violate mission constraints such as payload mass and propellant usage to insert into an NRHO. Based off previous one-year scan results for the SLS Block 1B Design Analysis Cycle 2 (DAC-2), it is expected that there will be one to three days per week where the payload is able to insert into an NRHO within SLS constraints objectives. This scan provides results for longer than one-year, allowing analysts to better understand the launch availability and energy requirements of SLS Block 1B over time. The in-space mission design and scans utilize Copernicus, an n-body trajectory optimization tool originally developed out of the University of Texas at Austin with further development at Johnson Space Center in Houston, TX. To seed the in-space trajectory, Copernicus uses a plugin to call a database of SLS ascent trajectories optimized in the Program to Simulate Optimized Trajectories II (POST2). The ascent trajectories are developed using a framework that parametrizes payload mass and LEO inclination, and targets a 100 nmi (nautical mile) altitude circular parking orbit. Though this analysis is specific to the SLS program, it will provide a summary of mission design benefits and constraints associated with generic NRHO access, and may be applied to other programs or concepts that will utilize this orbit.

Statham, T. L.↗

Predictive process simulation of cryogenic implants for leading edge transistor design

Two cryogenic implant TCAD-modules have been developed: (i) A continuum-based compact model targeted towards a TCAD production environment calibrated against an extensive data-set for all common dopants. Ion-specific calibration parameters related to damage generation and dynamic annealing were used and resulted in excellent fits to the calibration data-set. (ii) A Kinetic Monte Carlo (kMC) model including the full time dependence of ion-exposure that a particular spot on the wafer experiences, as well as the resulting temperature vs. time profile of this spot. It was calibrated by adjusting damage generation and dynamic annealing parameters. The kMC simulations clearly demonstrate the importance of the time-structure of the beam for the amorphization process: Assuming an average dose-rate does not capture all of the physics and may lead to incorrect conclusions. The model enables optimization of the amorphization process through tool parameters such as scan speed or beam height.

36 MATERIALS SCIENCE↗

High-stability cryogenic scanning tunneling microscope based on a closed-cycle cryostat

We report on the design and operation of a cryogenic ultra-high vacuum (UHV) scanning tunneling microscope (STM) coupled to a closed-cycle cryostat (CCC). The STM is thermally linked to the CCC through helium exchange gas confined inside a volume enclosed by highly flexible rubber bellows. The STM is thus mechanically decoupled from the CCC, which results in a significant reduction of the mechanical noise transferred from the CCC to the STM. Noise analysis of the tunneling current shows current fluctuations up to 4% of the total current, which translates into tip-sample distance variations of up to 1.5 picometers. This noise level is sufficiently low for atomic-resolution imaging of a wide variety of surfaces. To demonstrate this, atomic-resolution images of Au(111) and NaCl(100)/Au(111) surfaces, as well as of carbon nanotubes deposited on Au(111), were obtained. Thermal drift analysis showed that under optimized conditions, the lateral stability of the STM scanner can be as low as 0.18 Å/h. Scanning Tunneling Spectroscopy measurements based on the lock-in technique were also carried out, and showed no detectable presence of noise from the closed-cycle cryostat. Using this cooling approach, temperatures as low as 16 K at the STM scanner have been achieved, with the complete cool-down of the system typically taking up to 12 h. These results demonstrate that the constructed CCC-coupled STM is a highly stable instrument capable of highly detailed spectroscopic investigations of materials and surfaces at the atomic scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Propellant Loading System Senior Design Implement in Computer Algorithm

Propellant loading from the Storage Tank to the External Tank is one of the very important and time consuming pre-launch ground operations for the launch vehicle. The propellant loading system is a complex integrated system involving many physical components such as the storage tank filled with cryogenic fluid at a very low temperature, the long pipe line connecting the storage tank with the external tank, the external tank along with the flare stack, and vent systems for releasing the excess fuel. Some of the very important parameters useful for design purpose are the prediction of pre-chill time, loading time, amount of fuel lost, the maximum pressure rise etc. The physics involved for mathematical modeling is quite complex due to the fact the process is unsteady, there is phase change as some of the fuel changes from liquid to gas state, then conjugate heat transfer in the pipe walls as well as between solid-to-fluid region. The simulation is very tedious and time consuming too. So overall, this is a complex system and the objective of the work is student's involvement and work in the parametric study and optimization of numerical modeling towards the design of such system. The students have to first become familiar and understand the physical process, the related mathematics and the numerical algorithm. The work involves exploring (i) improved algorithm to make the transient simulation computationally effective (reduced CPU time) and (ii) Parametric study to evaluate design parameters by changing the operational conditions

Bandyopadhyay, Alak↗

Aluminum 2195 T8 Gore Development for Space Launch System Core and Upper Stage

Gores are pie-shaped panels that are welded together to form the dome ends of rocket fuel tanks as shown in figure 1. Replacing aluminum alloy 2219 with aluminum (Al)-lithium (Li) alloy 2195 as the Space Launch System (SLS) cryogenic tank material would save enormous amounts of weight. In fact, it has been calculated that simply replacing Al 2219 gores with Al 2195 gores on the SLS core stage domes could save approximately 3,800 pound-mass. This is because the Al-Li 2195 alloy exhibits both higher mechanical properties and lower density than the SLS baseline Al 2219 alloy. Indeed, the known advantages of Al 2195 led to its use as a replacement for Al 2219 in the shuttle external tank program. The required thicknesses of Al 2195 gores for either SLS core stage tanks or upper stage tanks will depend on the specific design configurations. The required thicknesses or widths may exceed the current experience base in the manufacture of such gores by the stretch-forming process. Accordingly, the primary objective of this project was to enhance the formability of Al 2195 by optimizing the heat treatment and stretch-forming process for gore thicknesses up to 0.75 inches, which envelop the maximum expected gore thicknesses for SLS tank configurations.

Volz, Martin↗

Shubnikov–de Haas oscillations of biaxial-strain-tuned superconductors in pulsed magnetic field up to 60 T

Two-dimensional (2D) materials have gained increasing prominence not only in fundamental research but also in daily applications. However, to fully harness their potential, it is crucial to optimize their properties with an external parameter and track the electronic structure simultaneously. Magnetotransport over a wide magnetic field range is a powerful method to probe the electronic structure and, for metallic 2D materials, quantum oscillations superimposed on the transport signals encode Fermi surface parameters. In this manuscript, we utilize biaxial strain as an external tuning parameter and investigate the effects of strain on the electronic properties of two quasi-2D superconductors, MoTe 2 and RbV 3 Sb 5 , by measuring their magnetoresistance in pulsed magnetic fields up to 60 T. With a careful selection of insulating substrates, we demonstrate the possibility of both the compressive and tensile biaxial strains imposed on MoTe 2 and RbV 3 Sb 5 , respectively. For both systems, the applied strain has led to superconducting critical temperature enhancement compared to their free-standing counterparts, proving the effectiveness of this biaxial strain method at cryogenic temperatures. Clear quantum oscillations in the magnetoresistance—the Shubnikov–de Haas (SdH) effect—are obtained in both samples. In strained MoTe 2 , the magnetoresistance exhibits a nearly quadratic dependence on the magnetic field and remains non-saturating even at the highest field, whereas in strained RbV 3 Sb 5 , two SdH frequencies showed a substantial enhancement in effective mass values, hinting at a possible enhancement of charge fluctuations. Our results demonstrate that combining biaxial strain and pulsed magnetic field paves the way for studying 2D materials under unprecedented conditions.

2D materials↗

Low-cost Oxygen (LCO) for Small-scale Modular Gasification Systems

Development of a sorbent-based vacuum pressure swing adsorption oxygen production technology was undertaken. Newly developed perovskite ceramic sorbent materials have a higher O 2 adsorption capacity, lower operating temperatures (550-600 °C vs 800-850 °C), and an order of magnitude faster desorption rate than those used in earlier development efforts. These performance advancements lead to substantial savings in capital investment and operational costs. Cost of producing oxygen using the new sorbents can be considerably lower than a cryogenic air separation unit. Development of these new sorbents and design and fabrication of a pilot demonstration unit (PDU) encompassed lab-scale work, bench-scale testing and development, demonstration-scale sorbent manufacturing, procurement of plant components, and final assembly and testing of the PDU. The goal of the project was to develop an advanced oxygen production technology based on improved perovskite ceramic sorbents that results in significantly lower oxygen cost compared to commercial state of the art technologies. The pilot demonstration unit was constructed and operated, but the performance of the scaled-up sorbent and the PDU was hindered by the mechanical problems with the system. When the problems are accounted for, the results show that the PDU would be able to produce 95% oxygen at a rate exceeding one ton per day. The same mechanical problems also mean that the PDU system was not fully optimized, which would increase the productivity as well.

01 COAL, LIGNITE, AND PEAT↗

Shubnikov-de Haas oscillations of biaxial-strain-tuned superconductors in pulsed magnetic field up to 60 T

Two-dimensional (2D) materials have gained increasing prominence not only in fundamental research but also in daily applications. However, to fully harness their potential, it is crucial to optimize their properties with an external parameter and track the electronic structure simultaneously. Magnetotransport over a wide magnetic field range is a powerful method to probe the electronic structure and, for metallic 2D materials, quantum oscillations superimposed on the transport signals encode Fermi surface parameters. In this manuscript, we utilize biaxial strain as an external tuning parameter and investigate the effects of strain on the electronic properties of two quasi-2D superconductors, MoTe 2 and RbV 3 Sb 5 , by measuring their magnetoresistance in pulsed magnetic fields up to 60 T. With a careful selection of insulating substrates, we demonstrate the possibility of both the compressive and tensile biaxial strains imposed on MoTe 2 and RbV 3 Sb 5 , respectively. For both systems, the applied strain has led to superconducting critical temperature enhancement compared to their free-standing counterparts, proving the effectiveness of this biaxial strain method at cryogenic temperatures. Clear quantum oscillations in the magnetoresistance—the Shubnikov–de Haas (SdH) effect—are obtained in both samples. In strained MoTe 2 , the magnetoresistance exhibits a nearly quadratic dependence on the magnetic field and remains non-saturating even at the highest field, whereas in strained RbV 3 Sb 5 , two SdH frequencies showed a substantial enhancement in effective mass values, hinting at a possible enhancement of charge fluctuations. Our results demonstrate that combining biaxial strain and pulsed magnetic field paves the way for studying 2D materials under unprecedented conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling The Effects of Loading Scenario and Thermal Expansion Coefficient on Potential Failure of Cryo-compressed Hydrogen Vessels

A multiscale thermomechanical model for a simplified Type-3 cryogenic compressed hydrogen (H2) storage vessel is developed in this paper. The model accounts for the temperature-dependent elastic-plastic behavior of the vessel carbon/epoxy composite overwrap and aluminum alloy liner. The homogenized thermo-elastic-plastic behavior for the individual laminas of the vessel layup is obtained by an incremental Eshelby-Mori-Tanka approach associated with a micromechanical failure criterion to predict lamina failure while a standard elastic-plastic constitutive model is used to describe the behavior of a typical aluminum alloy assumed for the liner. The vessel response to external loadings is achieved by a finite element method. Four loading scenarios representing four thermomechanical cycles applied to the vessel are analyzed to evaluate constituent and lamina stresses as well as the associate failure criterion during the cycle according to these scenarios. The model can provide helpful guidance to mitigate thermal stresses by an adequate selection of loading scenario, optimizing the layup and by tailoring thermomechanical properties of the resin matrix.

36 MATERIALS SCIENCE↗

Mechanical Milling – Induced Microstructure Changes in Argyrodite LPSCl Solid-State Electrolyte Critically Affect Electrochemical Stability

Microstructure of argyrodite solid-state electrolyte (SSE) critically affects lithium metal electrodeposition/dissolution. While the stability of unmodified SSE is mediocre, once optimized state-of-the-art electrochemical performance is achieved (symmetric cells, full cells with NMC811) without secondary interlayers or functionalized current collectors. Planetary mechanical milling in wet media (m-xylene) is employed to alter commercial Li 6 PS 5 Cl (LPSCl) powder. Quantitative stereology demonstrates how milling progressively refines grain and pore size/distribution in the SSE compact, increases its density, and geometrically smoothens the SSE-Li interface. Mechanical indentation demonstrates that these changes lead to reduced site-to-site variation in the compact's hardness. Milled microstructures promote uniform early-stage electrodeposition on foil collectors and stabilize solid electrolyte interphase (SEI) reactivity. Analysis of half-cells with bilayer electrolytes demonstrates the importance of microstructure directly contacting current collector, with interface roughness due to pore and grain size distribution being key. For the first time, short-circuiting Li metal dendrite is directly identified, employing 1.5 mm diameter “mini” symmetrical cell and cryogenic focused ion beam (cryo-FIB) electron microscopy. The branching sheet-like dendrite traverses intergranularly, filling the interparticle voids and forming an SEI around it. Importantly, mesoscale modeling reveals the relationship between Li-SSE interface morphology and the onset of electrochemical instability, based on underlying reaction current distribution.

25 ENERGY STORAGE↗

Status and results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay [0$vββ$] of 130 Te. The detector consists of a segmented array of 988 natural TeO 2 cubic crystals arranged in a cylindrical compact structure of 19 towers. The detector construction was completed in August 2016 and data taking started in Spring 2017. Here, we present a brief description of the bolometric technique for rare events search and the CUORE detector, then we concentrate on the data analysis results. In this respect, we focus on the procedure for data processing and on the first 0$vββ$ results we obtained from a total TeO 2 exposure of 86.3 kg · yr. Next, we illustrate the main background sources and the CUORE background model, from which we obtain the most precise measurement of 130 Te 2$vββ$ half-life to date. Finally, we discuss the improvements achieved with 2018 and 2019 detector optimization campaigns and the current perspectives of our experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NASA Tech Briefs, March 2011

Topics covered include: Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation; Airborne Radar Interferometric Repeat-Pass Processing; Plug-and-Play Environmental Monitoring Spacecraft Subsystem; Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz; Wallops Ship Surveillance System; Source Lines Counter (SLiC) Version 4.0; Guidance, Navigation, and Control Program; Single-Frame Terrain Mapping Software for Robotic Vehicles; Auto Draw from Excel Input Files; Observation Scheduling System; CFDP for Interplanetary Overlay Network; X-Windows Widget for Image Display; Binary-Signal Recovery; Volumetric 3D Display System with Static Screen; MMIC Replacement for Gunn Diode Oscillators; Feature Acquisition with Imbalanced Training Data; Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads; Carbon Nanotube-Based Structural Health Monitoring Sensors; Wireless Inductive Power Device Suppresses Blade Vibrations; Safe, Advanced, Adaptable Isolation System Eliminates the Need for Critical Lifts; Anti-Rotation Device Releasable by Insertion of a Tool; A Magnetically Coupled Cryogenic Pump; Single Piezo-Actuator Rotary-Hammering Drill; Fire-Retardant Polymeric Additives; Catalytic Generation of Lift Gases for Balloons; Ionic Liquids to Replace Hydrazine; Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings; Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger; Multi-Mission Power Analysis Tool; Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications; Gravitational Wave Detection with Single-Laser Atom Interferometers; Titanium Alloy Strong Back for IXO Mirror Segments; Improved Ambient Pressure Pyroelectric Ion Source; Multi-Modal Image Registration and Matching for Localization of a Balloon on Titan; Entanglement in Quantum-Classical Hybrid; Algorithm for Autonomous Landing; Quantum-Classical Hybrid for Information Processing; Small-Scale Dissipation in Binary-Species Transitional Mixing Layers; Superpixel-Augmented Endmember Detection for Hyperspectral Images; Coding for Parallel Links to Maximize the Expected Value of Decodable Messages; and Microwave Tissue Soldering for Immediate Wound Closure.

Source record↗

Thermal Performance of a Cryogenic Fluid Management Cubesat Mission

Development for an in-space demonstration of a CubeS at as a Cryogenic Fluid Management (CFM) test bed is currently underway. The favorable economics of CubeSats make them appealing for technology development activity. While their size limits testing to smaller scales, many of the regimes relevant to CFM can still be achieved. The first demo flight of this concept, CryoCube®-1, will focus on oxygen liquefaction and low-gravity level sensing using Reduced Gravity CryoTracker®. An extensive thermal modeling effort has been underway to both demonstrate concept feasibility and drive the prototype design. The satellite will utilize both a sun- and earth-shield to passively cool its experimental tank below 115 K. An on-board gas generator will create high pressure gaseous oxygen, which will be throttled into a bottle in the experimental node and condensed. The resulting liquid will be used to perform various experiments related to level sensing. Modeling efforts have focused on the spacecraft thermal performance and its effects on condensation in the experimental node. Parametric analyses for both optimal and suboptimal conditions have been considered and are presented herein.

Berg, J. J.↗

High-volume tunable resonator for axion searches above 7 GHz

In this research, we present results from an experimental demonstration of a tunable thin-shell axion haloscope whose geometry decouples its overall volume from its resonant frequency, thereby evading the steep sensitivity degradation at high frequencies. An aluminum 2.6-l (41⁢λ 3 ) prototype, which tunes from 7.1 to 8.0 GHz, was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable TM 010 mode is clearly identified with a room-temperature quality factor, Q, of approximately 5000. The on-resonance E-field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of 0.57 across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume V $\gg$ λ 3 . We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the postinflationary axion parameter space (approximately 4 to 30 GHz) at Dine-Fischler-Srednicki-Zhitnitsky sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient laser-driven proton acceleration from cylindrical and planar cryogenic hydrogen jets

We report on recent experimental results deploying a continuous cryogenic hydrogen jet as a debris-free, renewable laser-driven source of pure proton beams generated at the 150 TW ultrashort pulse laser Draco. Efficient proton acceleration reaching cut-off energies of up to 20 MeV with particle numbers exceeding 109 particles per MeV per steradian is demonstrated, showing for the first time that the acceleration performance is comparable to solid foil targets with thicknesses in the micrometer range. Two different target geometries are presented and their proton beam deliverance characterized: cylindrical (Ø 5 μm) and planar (20 μm × 2 μm). In both cases typical Target Normal Sheath Acceleration emission patterns with exponential proton energy spectra are detected. Significantly higher proton numbers in laser-forward direction are observed when deploying the planar jet as compared to the cylindrical jet case. As a result, this is confirmed by two-dimensional Particle-in-Cell (2D3V PIC) simulations, which demonstrate that the planar jet proves favorable as its geometry leads to more optimized acceleration conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The AIRES Optical Design

AIRES (Airborne InfraRed Echelle Spectrometer) is the facility spectrometer for SOFIA (Stratospheric Observatory For Infrared Astronomy). AIRES is a long-slit (approximately 160 in) spectrometer designed to cover the 17 to 210-micron range with good sensitivity using three spectroscopic arrays. Initially, only the 30-130 micron, mid-wavelength array will be available. The instrument has a cryogenic K-mirror to perform field rotation and a slit-viewing camera (lambda < 28 microns, FOV = 160 in diameter) to image source morphology and verify telescope pointing. AIRES employs a large echelle grating to achieve a spectral resolving power (lambda/delta lambda) of approximately 1.0 x 10(exp 6)/lambda (sub mu), where lambda (sub mu) is the wavelength in microns. Hyperfine, Inc. has ruled and tested the AIRES' echelle; its wave-front error is 0.028 waves RMS (root mean square) at 10.6 microns. The instrument is housed in a liquid-helium cryostat which is constrained in diameter (approximately 1 m) and length (approximately 2 m) by the observatory. Hence, the length of the echelle (approximately 1.1 m) and the focal length of its collimator (approximately 5.2 m) severely drive the optical design and packaging. The final design uses diamond-turned aluminum optics and has up to 19 reflections inside the cryostat, depending on the optical path. This design was generated, optimized, and toleranced using Code V. The predicted performance is nearly diffraction-limited at 17 microns; the error budget is dominated by design residuals. Light loss due to slit rotation and slit curvature has been minimized. A thorough diffraction analysis with GLAD (G-Level Analysis Drawer) was used to size the mirrors and baffles; the internal light loss is shown to be a strong function of slit width.

Haas, Michael R.↗

Photo-fragmentation spectroscopy of benzylium and 1-phenylethyl cations

The electronic spectra of cold benzylium (C{sub 6}H{sub 5}-CH{sub 2}{sup +}) and 1-phenylethyl (C{sub 6}H{sub 5}-CH-CH{sub 3}{sup +}) cations have been recorded via photofragment spectroscopy. Benzylium and 1-phenylethyl cations produced from electrosprayed benzylamine and phenylethylamine solutions, respectively, were stored in a cryogenically cooled quadrupole ion trap and photodissociated by an OPO laser, scanned in parts of the UV and visible regions (600–225 nm). The electronic states and active vibrational modes of the benzylium and 1-phenylethyl cations as well as those of their tropylium or methyl tropylium isomers have been calculated with ab initio methods for comparison with the spectra observed. Sharp vibrational progressions are observed in the visible region while the absorption features are much broader in the UV. The visible spectrum of the benzylium cation is similar to that obtained in an argon tagging experiment [V. Dryza, N. Chalyavi, J. A. Sanelli, and E. J. Bieske, J. Chem. Phys. 137, 204304 (2012)], with an additional splitting assigned to Fermi resonances. The visible spectrum of the 1-phenylethyl cation also shows vibrational progressions. For both cations, the second electronic transition is observed in the UV, around 33 000 cm{sup −1} (4.1 eV) and shows a broadened vibrational progression. In both cases the S{sub 2} optimized geometry is non-planar. The third electronic transition observed around 40 000 cm{sup −1} (5.0 eV) is even broader with no apparent vibrational structures, which is indicative of either a fast non-radiative process or a very large change in geometry between the excited and the ground states. The oscillator strengths calculated for tropylium and methyl tropylium are weak. Therefore, these isomeric structures are most likely not responsible for these absorption features. Finally, the fragmentation pattern changes in the second and third electronic states: C{sub 2}H{sub 2} loss becomes predominant at higher excitation energies, for both cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗