Search NASASearch

SEARCH · Search NASA

Results for “design of experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,251 records · Page 37

Piloting Vertical Flight Aircraft: A Conference on Flying Qualities and Human Factors

This document contains papers from a specialists' meeting entitled "Piloting Vertical Flight Aircraft. A Conference on Flying Qualities and Human Factors." The conference was co-sponsored by the American Helicopter Society--San Francisco Bay Chapter, and the NASA Ames Research Center. It was held January 20-22, 1993 at the Sheraton Hotel Fisherman's Wharf, San Francisco, California. Vertical flight aircraft, including helicopters and a variety of Vertical Takeoff and Landing (VTOL) concepts, place unique requirements on human perception, control, and performance for the conduct of their design missions. The intent of this conference was to examine, for these vehicles, advances in: (1) design of flight control systems for ADS-33C standards; (2) assessment of human factors influences of cockpit displays and operational procedures; (3) development of VTOL design and operational criteria; and (4) development of theoretical methods or models for predicting pilot-vehicle performance and mission suitability. Recognizing that human capabilities and limitations form an integral aspect of the operations for these classes of vehicles, a secondary goal of the conference was to provide an initial venue for enhanced interaction between human factors and handling qualities specialists.

Helicopter

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]

The Galileo probe Li/SO2 battery: The safest battery on Jupiter

The unique power requirement of NASA's Galileo Jupiter Probe are most readily met by a Li/SO2 battery; however, because this battery system is not space flight proven, extensive effort was required to qualify this device from the stand point of performance and safety. Due to the rather checkered safety record of the Li/SO2 system, safety has been foremost among the design considerations and has been addressed at the cell, battery and system level. The mission requirements which led to the choice of the Li/SO2 battery and the safety engineering which went into the battery and power system design are described.

Marcoux, L. S.

The Role of Nuclear Data Sensitivities in Prompt α-Eigenvalue Predictions of Delayed Critical Benchmarks

Alpha (α) eigenvalues, which describe the logarithmic time derivative of the neutron population in a multiplying system, are integral to time-dependent behavior and diagnostic applications. However, uncertainties in the evaluated nuclear data can significantly impact the accuracy of transport simulations for such quantities. This work explores the use of machine learning models to predict two key outputs, α-eigenvalues and keff bias, using input features derived from α-eigenvalue sensitivities to nuclear data. The criticality safety benchmark models used in this study come from the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Three models, random forest, XGBoost, and NGBoost, are trained on both energy-resolved and energy-summed α sensitivities. For the α-eigenvalue bias prediction, NGBoost achieved the highest R 2 (0.9476) using energy-resolved features, while XGBoost performed best using summed sensitivities. In contrast, when predicting the keff bias, all the models showed moderate predictive capability (best R 2 ≈ 0.72), as the mapping from the static α-sensitivities to the static keff bias was less direct. SHAP (SHapley Additive exPlanations) analysis was used to interpret the model predictions. Across both prediction tasks, the features associated with neutron capture [H-1 (n, γ)], uranium scattering reactions (such as 235 U elastic/inelastic), and actinide capture/fission reactions (such as 239 Pu and 234 U) were consistently identified as the most impactful. This highlights the key role of specific nuclear reactions and energy ranges in shaping both time-dependent and steady-state criticality behavior. These results demonstrated that α-sensitivities, despite being computed for time-dependent metrics, can provide valuable insights for predicting both α-eigenvalues and the keff bias. Moreover, machine learning models offer a promising pathway for uncovering important nuclear data dependencies and guiding future data evaluation efforts.

Nuclear data

Risks of Depress as a Fire Suppression Technique in Spacecraft

Spacecraft are designed to prevent fires through careful material selection and configuration control combined with electrical design controls and isolation of ignition sources. Despite these best efforts, fire risk still exists due to the potential for configuration changes with the introduction of crew and the potential for a ‘failure of imagination’ by designers in anticipating all fuel and ignition sources. Therefore, fire suppression is a critical capability for any crewed spacecraft as a last resort for crew survival. Many spacecraft suppression methods have relied on fire suppressants such as compressed carbon dioxide, nitrogen, and water. A proposed alternative is depressurization of the cabin as a method to extinguish a fire. Limited testing was conducted during Skylab and showed that depress could result in stirring the air flow and aggravating a fire before extinguishing. However, limited information was available on how the test was conducted. To better characterize the approach, testing was conducted at NASA’s White Sands Test Facility to evaluate the effect of depressurization on material extinguishment. The results showed that depressurization does not provide a safe and effective fire suppression capability. The testing approach, results, and conclusions are described and discussed.

Toni Griego

Battery charge control with temperature compensated voltage limit

Battery charge control for orbiting spacecraft with mission durations from three to ten years, is a critical design feature that is discussed. Starting in 1974, the General Electric Space Systems Division designed, manufactured and tested battery systems for six different space programs. Three of these are geosynchronous missions, two are medium altitude missions and one is a near-earth mission. All six power subsystems contain nickel cadmium batteries which are charged using a temperature compensated voltage limit. This charging method was found to be successful in extending the life of nickel cadmium batteries in all three types of earth orbits. Test data and flight data are presented for each type of orbit.

Thierfelder, H. E.

Air-Breathing Aerospace Plane Development Essential: Hypersonic Propulsion Flight Tests

Hypersonic airbreathing propulsion utilizing scramjets can change transatmospheric accelerators for low earth-to-orbit and return transportation. The value and limitation of ground tests, of flight tests, and of computations are presented, and scramjet development requirements are discussed. It is proposed that near full-scale hypersonic propulsion flight tests are essential for developing computational design technology so that it can be used for designing this system. In order to determine how these objectives should be achieved, some lessons learned from past programs are presented. A conceptual two-stage-to-orbit (TSTO) prototype/experimental aerospace plane is recommended as a means of providing access-to-space and for conducting flight tests.

Unmeel B Mehta

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Scan‐Path‐ and Initial‐State‐Dependent Superdomain Switching in (111)‐Oriented PZT

Polarization switching in ferroelectric materials arises from the collective evolution of complex domain hierarchies, yet deterministic control over these processes remains challenging. Here, we investigate scan-path- and initial-state-dependent switching in epitaxial (111)-oriented PbZr 0.2 Ti 0.8 O 3 thin films using automated AFM-based writing combined with quantitative 3D piezoresponse force microscopy. We show that the scan trajectory acts as an experimentally accessible control parameter for superdomain formation. Box-in-box raster scans reproducibly stabilize ordered stripe superdomains with a reduced subset of symmetry-allowed variants, whereas spiral trajectories generate frustrated mixed-variant states with a broader distribution of final microstructures. Automated pulsing experiments further show that the local superdomain configuration at the nucleation site strongly influences the final written morphology. Phase-field modeling qualitatively reproduces the contrast between representative initial-state geometries and supports the role of compatibility constraints among competing ferroelastic pathways. These findings establish scan-path and initial-state engineering as practical handles to program ferroic order in hierarchical ferroelectric domain structures.

Vasudevan, Rama K. [Oak Ridge National Laboratory

Fifth Aerospace Mechanisms Symposium

Conference of structural design principles and mechanical engineering methods for aerospace mechanisms used in orbital and space flights

Bowden W Ward

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Update on Development of 360V, 28kWh Lithium-Ion Battery

Engineering unit submodule batteries (EUSB) the 360V, 28kWh EAPU battery were designed and assembled by COM DEV. These submodules consist of Sony Li-Ion 18650HC cells in a 5P-41S array yielding 180V, 1.4 kWh. Tests of these and of substrings and single cells at COM DEV and at JSC under various performance and abuse conditions demonstrated that performance requirements can be met. The thermal vacuum tests demonstrated that the worst case hot condition is the design driver. Deficiencies in the initial diode protection scheme of the battery were identified as a result of test failures. Potential solutions to the scheme are under development and will be presented.

Davies, Francis

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig

Progress on Shape Memory Alloy Actuator Development for Active Clearance Control

Results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine has been conducted. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 in. Design results show that an actuator comprised of 10 wires 2 in. in length is adequate for control at critical engine operating points and still exhibit acceptable failsafe operability and cycle life. A proportional-integral- derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

Jonathan DeCastro