Search NASA⌕ Search

SEARCH · Search NASA

Results for “dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Analysis of the Effects of a Flexible Ramping Ancillary Service Product on Power System Operations: Preprint

The recent increased interest in utilizing variable generation (VG) resources such as wind and solar in power systems has motivated investigations into new operating procedures. Although these resources provide desirable value to a system (e.g., no fuel costs or emissions), interconnecting them provides unique challenges. Their variable, non-controllable nature in particular requires significant attention, because it directly results in increased power system variability and uncertainty. One way to handle this is via new operating reserve schemes. Operating reserves provide upward and downward generation and ramping capacity to counteract uncertainty and variability prior to their realization. For instance, uncertainty and variability in real-time dispatch can be accounted for in the hour-ahead unit commitment. New operating reserve methodologies that specifically account for the increased variability and uncertainty caused by VG are currently being investigated and developed by academia and industry. This paper examines one method inspired by the new operating reserve product being proposed by the California Independent System Operator. The method is based on examining the potential ramping requirements at any given time and enforcing those requirements via a reserve demand curve in the market-clearing optimization as an additional ancillary service product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational Impacts of Operating Reserve Demand Curves on Production Cost and Reliability

The electric power industry landscape is continually evolving. As emerging technologies such as wind, solar, electric vehicles, and energy storage systems become more cost-effective and present in the system, traditional power system operating strategies will need to be reevaluated. The presence of wind and solar generation (commonly referred to as variable generation) may result in an increase in the variability and uncertainty of the net load profile. One mechanism to mitigate this is to schedule and dispatch additional operating reserves. These operating reserves aim to ensure that there is enough capacity online in the system to account for the increased variability and uncertainty occurring at finer temporal resolutions. A new operating reserve strategy, referred to as flexibility reserve, has been introduced in some regions. A similar implementation is explored in this paper, and its implications on power system operations are analyzed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Assessment of Power Systems With Uncertain Renewable Generation: Preprint

The transient stability of a power system depends heavily on its operational state at the moment of a fault. In systems where the penetration of renewable generation is significant, the dispatch of the conventional fleet of synchronous generators is uncertain at the time of dynamic security analysis. Hence, the assessment of transient stability requires the solution of a system of nonlinear ordinary differential equations with unknown initial conditions and inputs. To this end, we set forth a computational framework that relies on Taylor polynomials, where variables are associated with the level of renewable generation. This paper describes the details of the method and illustrates its application on a nine-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

REopt Lite Web Tool Evaluates Photovoltaics and Battery Storage

Building on the success of the REopt renewable energy integration and optimization platform, NREL has developed a free, publicly available web version of REopt called REopt Lite. REopt Lite evaluates the economics of grid-connected photovoltaics (PV) and battery storage at a site. It allows building owners to identify the system sizes and battery dispatch strategy that minimize their life cycle cost of energy. This web tool also estimates the amount of time a PV and storage system can sustain the site's critical load during a grid outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

When Solar+Storage Make Sense

An NREL presentation details the benefits and challenges of solar plus storage systems. Benefits can include reduced utility bills, reduced demand charges, and increased resilience, or the ability to meet critical load during grid outages. Challenges can include dispatching and islanding controls, and quantifying the benefits of resilience. Decision support tools, such as NREL's REopt, aid the energy planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrolysis' Potential Value for Supporting the Electrical Grid

The H2@Scale concept includes a value proposition for electrolysis that benefits both hydrogen markets and the electricity system. Electrolysis has the potential to be an alternative low-cost hydrogen source by using low-price electricity that may be available for only a limited number of hours annually. It also has the potential to provide value to the grid through use of that low-cost electricity. By doing so, electrolysis can create a price floor which could support additional investment in low-cost, dispatch-constrained electricity (LDE) generation such as photovoltaic solar, wind, and nuclear. The rapid-response characteristics of low-temperature electrolysis enables it to also provide ancillary services to the grid such as operating reserves and frequency control. We evaluate the economic performance of water electrolysis in a selection of electricity markets - both current and potential future markets. To perform that evaluation, we collect locational marginal prices (LMPs) in each market, calculate levelized hydrogen costs, and compare them to cost estimates of producing hydrogen via steam methane reforming of natural gas. Those calculations also include electolyzer capital and operating costs. We perform the calculations across a range of capacity factors to identify the minimum levelized hydrogen cost in that range. We discuss the implications of that capacity factor for each market analyzed. For a couple of the analyzed electricity markets, we include the potential value of providing ancillary services in the calculation and discuss those impacts. LDE generation has been shown to suppress electricity prices because it generates electricity when the resource is available (i.e., the sun is shining, wind is blowing, nuclear heat is being produced) and the generation cannot be reduced without an economic penalty. Price suppression is likely to reduce investment in those technologies due to reductions in projected income of each marginal unit. If electrolyzers are willing to pay for the LDE, it could provide a price floor for electricity. We analyze how setting a price for LDE could impact the electricity generation fleet, the availability of LDE, and the potential levelized costs of producing hydrogen using that LDE. Among other results, we will present a set of supply curves showing potential production costs and availability for hydrogen produced from LDE in a future with high penetrations of renewable electricity on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluate Distributed Energy Technologies for Cost Savings and Resilience With REopt Lite

NREL's REopt Lite TM web tool evaluates the economics of grid connected photovoltaics (PV), wind, and battery storage at a site. It allows users to identify the system sizes and battery dispatch strategy that minimize a site's life cycle cost of energy, and it estimates the amount of time a PV, wind, battery, and diesel generator system can sustain the site's critical load during a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recent Improvements in PV+Battery Modeling in NREL's System Advisor Model

This poster covers recent updates to the NREL System Advisor Model's battery model that can be coupled to the PV model to add value to both front of meter and behind the meter systems. Topics include new dispatch algorithms focusing on smoothing the output of a PV plant to meet ramp rate requirements and responding to price signals to maximize system revenue, validated battery lifetime models, grid outage simulations and resiliency metrics, and the new levelized cost of storage (LCOS) metric. We will also share preliminary results from NREL analysis projects using these features.

battery↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Rapid Procedure Development Approach for Multi-stage Validation of Novel Nuclear Power Plant Systems

The integration of renewable energy sources into the modern grid introduces variability in generation, challenging nuclear reactors to remain economically viable amid low wholesale electricity prices. To address this, Idaho National Laboratory?s Flexible Plant Operation and Generation program explores alternative revenue streams, including commoditizing excess thermal energy. A Thermal Power Dispatch (TPD) system enables steam extraction from the secondary loop for industrial uses like hydrogen production via high-temperature steam electrolysis.

99 - GENERAL AND MISCELLANEOUS↗

Decarbonization of the Electric Power Sector and Implications for Low-Cost Hydrogen Production from Water Electrolysis

Increasing development of wind and solar generation in the power sector can create economic opportunities for the deployment of water electrolyzers that produce hydrogen. Temporal variation in the marginal cost of energy in future decarbonized grids can make it favorable for electrolyzers to dispatchably ramp hydrogen production up and down in response to low- and high-cost times. Using this strategy, low-cost hydrogen production is enabled by electrolyzers that are low-capital cost and tolerant to frequent on/off cycling. Ramping down hydrogen production to a designated turndown ratio can avoid performance degradation caused by on/off cycling by not shutting the electrolyzer completely off. This comes with a slight cost penalty which can be minimized if the turndown ratio is low (i.e., the system ramps down hydrogen production to close to zero). These results suggest that electrolyzers integrated into future power systems are likely to benefit from the ability to ramp operation up and down quickly and operate in a standby mode. This analysis forms a basis for comparative tradeoffs between electrolyzer capital cost, operating strategy, and system durability and demonstrates the importance of considering all three factors in technoeconomic analysis.

capital cost↗

OpenABLext: An automatic code generation framework for agent-based simulations on CPU-GPU-FPGA heterogeneous platforms

The execution of agent-based simulations (ABSs) on hardware accelerator devices such as graphics processing units (GPUs) has been shown to offer great performance potentials. However, in heterogeneous hardware environments, it can become increasingly difficult to find viable partitions of the simulation and provide implementations for different hardware devices. To automate this process, we present OpenABLext, an extension to OpenABL, a model specification language for ABSs. By providing a device-aware OpenCL backend, OpenABLext enables the co-execution of ABS on heterogeneous hardware platforms consisting of central processing units, GPUs, and field programmable gate arrays (FPGAs).We present a novel online dispatching method that efficiently profiles partitions of the simulation during run-time to optimize the hardware assignment while using the profiling results to advance the simulation itself. In addition, OpenABLext features automated conflict resolution based on user-specified rules, supports graph-based simulation spaces, and utilizes an efficient neighbor search algorithm. We show the improved performance of OpenABLext and demonstrate the potential of FPGAs in the context of ABS. We illustrate how co-execution can be used to further lower execution times. OpenABLext can be seen as an enabler to tap the computing power of heterogeneous hardware platforms for ABS.

97 MATHEMATICS AND COMPUTING↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Comparison of removal and spatial mark‐resight models for estimating wild pig density

Density estimation is critical to effectively manage invasive species and elucidate areas of highest concern. For wild pigs (Sus scrofa), the ability to estimate density is complicated because of their variable home range sizes and social structure. Common methods for estimating density (e.g., mark-recapture) may be unsuitable in management applications because additional data needs to be collected before and after management. Removal models offer a suitable alternative to estimate density changes following management and can be applied broadly across areas where management of wild pigs is ongoing. We collected wild pig removal and camera trap data from 25 private properties ranging in size from approximately 0.5 km 2 to 95 km 2 across 3 ecoregions in South Carolina, USA, from 2020–2023. We compared factors affecting consistency and precision of property-level density estimates between removal and spatial mark-resight (SMR) models. In general, excluding 1 large outlier, density estimates from removal models were between 0.60 and 15.85 wild pigs/km 2 (median = 5.34) with a median coefficient of variation (CV) of 0.76 and 95% confidence intervals for the CV between 0.70 and 0.94. Similarly, excluding 1 large outlier, density estimates from SMR were between 0.22 and 30.97 wild pigs/km 2 (median = 5.48) with a median CV of 0.39 and 95% confidence intervals for the CV between 0.38 and 1.20. We found the precision of removal models was affected primarily by the number of wild pigs dispatched in the removal period (3 months) and the ecoregion in which they were removed. None of the covariates, including the number of recaptures (a corresponding measure of sample size), influenced precision of the SMR models, although recaptures did influence the density estimates. At the individual property level, density estimates from our 2 estimators were dissimilar from each other in approximately 80% of instances, although none of the covariates we examined influenced dissimilarity. Our results provide unique insight into how sample size affects density estimates using 2 common methods and into novel SMR models that incorporate both marked and unmarked detections. In addition, the density estimates in this study can be used as a reference for wild pig densities in common land cover types throughout the southeastern United States.

60 APPLIED LIFE SCIENCES↗

Hydro power flexibility for power systems with variable renewable energy sources: an IEA Task 25 collaboration: Hydro power flexibility for power systems

Hydro power is one of the most flexible sources of electricity production. Power systems with considerable amounts of flexible hydro power potentially offer easier integration of variable generation, e.g., wind and solar. However, there exist operational constraints to ensure mid-/long-term security of supply while keeping river flows and reservoirs levels within permitted limits. In order to properly assess the effective available hydro power flexibility and its value for storage, a detailed assessment of hydro power is essential. Due to the inherent uncertainty of the weather-dependent hydrological cycle, regulation constraints on the hydro system, and uncertainty of internal load as well as variable generation (wind and solar), this assessment is complex. Hence, it requires proper modeling of all the underlying interactions between hydro power and the power system, with a large share of other variable renewables. A summary of existing experience of wind integration in hydro-dominated power systems clearly points to strict simulation methodologies. Recommendations include requirements for techno-economic models to correctly assess strategies for hydro power and pumped storage dispatch. These models are based not only on seasonal water inflow variations but also on variable generation, and all these are in time horizons from very short term up to multiple years, depending on the studied system. Another important recommendation is to include a geographically detailed description of hydro power systems, rivers' flows, and reservoirs as well as grid topology and congestion.

13 HYDRO ENERGY↗

Porting Adaptive Ensemble Molecular Dynamics Workflows to the Summit Supercomputer

Molecular dynamics (MD) simulations must take very small (femtosecond) integration steps in simulation-time to avoid numerical errors. Efficient use of parallel programming models and accelerators in state-of-the art MD programs now is pushing Moore’s limit for time-per-MD step. As a result, directly simulating timescales beyond milliseconds will not be attainable directly, even at exascale. However, concepts from statistical physics can be used to combine many parallel simulations to provide information about longer timescales and to adequately sample the simulation space, while preserving details about the dynamics of the system. Implementing such an approach requires a workflow program that allows adaptable steering of task assignments based on extensive statistical analysis of intermediate results. Here we report the implementation of such an adaptable workflow program to drive simulations on the Summit IBM Power System AC922, a pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF). We compare to experiences on Titan, Summit’s predecessor, report the performance of the workflow and its components, and describe the porting process. We find that using a workflow program managed by a Mongo database can provide the fault tolerance, scalable performance, task dispatch rate, and reconfigurability required for robust and portable implementation of ensemble simulations such as are used in enhanced-sampling molecular dynamics. This type of workflow generator can also be used to provide adaptive steering of ensemble simulations for other applications in addition to MD.

Ossyra, John R.↗

OpenACC Unified Programming Environment for Multi-hybrid Acceleration with GPU and FPGA

Accelerated computing in HPC such as with GPU, plays a central role in HPC nowadays. However, in some complicated applications with partially different performance behavior is hard to solve with a single type of accelerator where GPU is not the perfect solution in these cases. We are developing a framework and transpiler allowing the users to program the codes with a single notation of OpenACC to be compiled for multi-hybrid accelerators, named MHOAT (Multi-Hybrid OpenACC Translator) for HPC applications. MHOAT parses the original code with directives to identify the target accelerating devices, currently supporting NVIDIA GPU and Intel FPGA, dispatching these specific partial codes to background compilers such as NVIDIA HPC SDK for GPU and OpenARC research compiler for FPGA, then assembles binaries for the final object with FPGA bitstream file. In this paper, we present the concept, design, implementation, and performance evaluation of a practical astrophysics simulation code where we successfully enhanced the performance up to 10 times faster than the GPU-only solution.

Boku, Taisuke↗

A cross-platform execution engine for the quantum intermediate representation

Hybrid languages like the quantum intermediate representation (QIR) are essential for programming systems that mix quantum and conventional computing models, while execution of these programs is often deferred to a system-specific implementation. Here, we develop the QIR Execution Engine (QIR-EE) for parsing, interpreting, and executing QIR across multiple hardware platforms. QIR-EE uses LLVM to execute hybrid instructions specifying quantum programs and, by design, presents extension points that support customized runtime and hardware environments. We demonstrate an implementation that uses the XACC quantum hardware-accelerator library to dispatch prototypical quantum programs on different commercial quantum platforms and numerical simulators, and we validate execution of QIR-EE on IonQ, Quantinuum, and IBM hardware. Our results highlight the efficiency of hybrid executable architectures for handling mixed instructions, managing mixed data, and integrating with quantum computing frameworks to realize cross-platform execution.

LLVM↗