Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

4D Proxy Imaging of Fracture Dilation and Stress Shadowing Using Electrical Resistivity Tomography During High Pressure Injections into a Dense Rock Formation

Fluid flow through fractured rock systems is governed in large part by the distribution, interconnectivity, and size of fracture apertures. In-situ stress is one of the primary factors controlling fracture aperture, and one that is altered significantly during high-pressure fluid injections or extractions. Interactions between stress, pore pressure, aperture, and fluid flow can result in complex and evolving poroelastic behavior with significant implications regarding the predictability and risk of developing and managing deep subsurface reservoirs (geothermal, fossil energy, and geologic carbon sequestration). In saturated crystalline rocks, bulk electrical conductivity is highly sensitive to porosity, and therefore to fracture aperture size and distribution. We demonstrate the use of time-lapse 3D electrical resistivity tomography for remotely monitoring stress induced changes in aperture distribution during high pressure injections into a fractured rock system at a scale of tens of meters. Results reveal a complex and continuously evolving stress field involving aperture dilations in the natural fracture system and aperture contractions in adjacent zones of shadow stress. Results provide information about the spatiotemporal changes in the system behavior and point to the potential of electrical imaging for autonomously and remotely monitoring evolving stress conditions by proxy through changes in bulk electrical conductivity.

electrical resisitivity tomography, stress, 4D Tim↗

Working With Your Utility Series: Interconnection Basics

This training provided information on interconnection basics for federal agencies developing distributed energy projects. Considerations covered included: Understanding interconnection processes and timelines, interconnection siting considerations, technology-specific interconnection issues, and interconnect agreements. This webinar is the first in a multi-part series on working with electric utilities to develop distributed energy projects on federal sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Distribution Level Wide Area Monitoring System for the Electric Power Grid–FNET/GridEye

The wide area monitoring system (WAMS) is considered a pivotal component of future electric power grids. As a pilot WAMS that has been operated for more than a decade, the frequency monitoring network FNET/GridEye makes use of hundreds of global positioning system-synchronized phasor measurement sensors to capture the increasingly complicated grid behaviors across the interconnected power systems. In this paper, the FNET/GridEye system is overviewed and its operation experiences in electric power grid wide area monitoring are presented. Particularly, the implementation of a number of data analytics applications will be discussed in details. FNET/GridEye lays a firm foundation for the later WAMS operation in the electric power industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TEAMER: Electrically Engaged Undulation (EEL) System

The Electrically Engaged UnduLation (EEL) system is a buoyancy-driven submersible device for powering oceanographic instruments. Physically, EEL is a slender body whose flexible spine is made up of energy units interconnected by uniaxial hinges. Each unit consists of a pair of piezoelectric elements that converts the bending stress into electrical current to a battery charging circuit. An outer plastic skin forms a seal against water and allows for flexibility at hinge locations. At the top is a bluff body with electronics that holds a ballast for buoyancy adjustment. The bluff body is also responsible for creating fluid instabilities in its wake. When gliding through the water (mode 2), the spine will flex in response to the alternating vortices that shed from the head. This "lock-in" phenomenon occurs when the frequency at which vortices shed resonates with the EEL natural frequency, during which the efficient gaits were found in species of sea snake, eels, and fish. For active propulsion, a single motor can be placed at the first segment and provide the oscillatory input for propulsion similar to a dolphin's kick. Such anguilliform swimming is both efficient and nearly silent compared to a spinning propeller. Ultimately, mimicking bio-locomotion provides a viable path to a drag-reduced, self-propelled energy harvesting system for ocean monitoring.

16 TIDAL AND WAVE POWER↗

Installation and Assembly, Electrical Ground Support Equipment (GSE), Specification for

This specification covers the general workmanship requirements and procedures for the complete installation and assembly of electrical ground support equipment (EGSE) such as terminal distributors, junction boxes, conduit and fittings, cable trays and accessories, interconnecting cables (including routing requirements), motor-control equipment, and necessary hardware as specified by the applicable contract and drawings.

Electrical and Electronics↗

Solar Cell Modules with Parallel Oriented Interconnections

Twenty-four solar modules, half of which were 48 cells in an all-series electrical configuration and half of a six parallel cells by eight series cells were provided. Upon delivery of environmentally tested modules, low power outputs were discovered. These low power modules were determined to have cracked cells which were thought to cause the low output power. The cracks tended to be linear or circular which were caused by different stressing mechanisms. These stressing mechanisms were fully explored. Efforts were undertaken to determine the causes of cell fracture. This resulted in module design and process modifications. The design and process changes were subsequently implemented in production.

Source record↗

Thermal, mechanical, and electrical properties of LSCo/mullite composite contact materials for solid oxide fuel cells

Lanthanum strontium cobaltite (LSCo) is considered as a good candidate cathode contact material for solid oxide fuel cells, due to high electrical conductivity. However, LSCo has a very large coefficient of thermal expansion (CTE) than the cells and metallic interconnects. As a result, poor mechanical stability is expected during thermal cycling. To minimize the CTE mismatch, we investigate a composite approach involving mixing LSCo with an inert material of low CTE, such as mullite at volume fractions from 0.1 to 0.4. Composite’s CTE shows a decreasing trend with increasing mullite volume fractions, and is consistent with model predictions. X-ray powder diffraction analysis of sintered LSCo/mullite composites exhibits no presence of other phases for samples aged for 500h at 800oC, indicating chemical compatibility. Electrical conductivity by a 4-pt method shows a decreasing trend with increasing mullite content. Contact strength of as-sintered and thermally cycled samples show that only the composite with 0.4 volume fraction has a measurable strength; the other composites have no strength. Overall, the composite approach is demonstrated in the LSCo/mullite system to lower the CTE and hence achieve thermal cycle stability. The addition of the inert phase to the LSCo matrix; however, also reduces the electrical conductivity.

Contact materials, LSCo, mullite, CTE, electrical ↗

Examination of Potential Benefits of an Energy Imbalance Market in the Western Interconnection

In the Western Interconnection, there is significant interest in improving approaches to wide-area coordinated operations of the bulk electric power system, in part because of the increasing penetration of variable generation. One proposed solution is an energy imbalance market. This study focused on that approach alone, with the goal of identifying the potential benefits of an energy imbalance market in the year 2020.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Intrinsic Stability of Thin-Film CdS/CdTe Modules

Stability of thin-film CdTe module is crucial to the advancement of the technology. Long-term stability studies are carried out under a variety of accelerated test conditions. Accelerated-life-tests (ALT) are performed in the laboratory to accelerate degradation and hence quantify performance change in reasonably short periods of time. ALT studies attempt to simulate the conditions a solar module experiences outdoors during its lifetime, and ALT results are correlated to outdoor test results to estimate module service lifetimes, nameplate parameters, and product warranty. To accelerate degradation, laboratory experiments are often performed at elevated temperature, voltage bias and under continuous illumination. In this study laboratory size cells (0.5 cm{sup 2}), mini-modules (15 cm x 15 cm) and full-size encapsulated modules (60 cm x 120 cm) that consist of monolithically interconnected cells were subjected to different levels of illumination, elevated temperatures and electrical biases for extended periods of time. Changes in efficiency, fill-factor (FF), open-circuit voltage (Voc) and short-circuit current (Isc) as a function stress time and stress conditions are discussed.

14 SOLAR ENERGY↗

Frequency Response Tool

According to the North American Electric Reliability Corporation (NERC) definition: "Frequency response is a measure of an Interconnection's ability to stabilize frequency immediately following the sudden loss of generation or load, and is a critical component of the reliable operation of the Bulk-Power System, particularly during disturbances and recoveries. Failure to maintain frequency can disrupt the operation of equipment and initiate disconnection of power plant equipment to prevent it from being damaged, which could lead to wide-spread blackouts." Frequency Response Tool automates the power system frequency response analysis process. The tool performs initial estimation of the system frequency parameters (initial frequency, minimum frequency, settling point). User can visually inspect and adjust these parameters. The tool also calculates the frequency response performance metrics of the system, archives the historic events and baselines the system performance. Frequency response performance characteristics of the system are calculated using phasor measurement unit (PMU) information. Methodology of the frequency response performance assessment implemented in the tool complies with the NERC Frequency response standard.

Etingov, Pavel↗

Residential PV-Energy Storage Testing Collaboration with SunPower: Cooperative Research and Development Final Report, CRADA Number CRD-14-569

Residential scale energy storage devices have shown great promise to add value and improve the ability to integrate distributed and variable generation into the distribution grid. Battery energy storage systems combined with PV and advanced inverters can provide many services. These include extended backup power in case of grid failure, reductions in feeder and system level peak load, system level net load ramp reduction, grid management services both locally (e.g., voltage management) and bulk system (e.g., reserves) level, and improved grid reliability through grid voltage and frequency support. Even though the cost of the energy storage systems are decreasing, one of the main challenges related to the widespread deployment of energy storage, as found by the U.S. Department of Energy (DOE), is utility acceptance of storage technologies. Various interconnection challenges exist when connecting distributed PV-energy storage into the electrical distribution grid in terms of safety, reliability and stability of the electric power systems. Some of the urgent challenges, as seen by the manufacturers and installers are: safety of the battery cells and the packs, performance of the power conversion systems, effect of bidirectional power flow on existing utility equipment and qualification of solutions such as volt-ampere reactive (VAR) support and frequency regulation. Under this project, National Renewable Energy Laboratory (NREL) researchers will work with SunPower to address these challenges by research, testing and analysis at Energy System Integration Facility (ESIF) and energy storage testing laboratory at NREL. NREL's unique power hardware-in-the-loop (PHIL) capability will be utilized to evaluate system-level issues such as reverse power flow and VAR support (if available) for these PV-energy storage systems. Through the analysis of test results, the proposed project will demonstrate use of ESIF capabilities in a way that advances both the DOE and SunPower's goals of moving clean, renewable energy technologies onto the electrical grid.

14 SOLAR ENERGY↗

Tehachapi Wind Energy Storage Project - Technology Performance Report #3

The TSP is located at SCE’s Monolith Substation in Tehachapi, California. The 8 MW, 4 hours (32 MWh) BESS is housed in a 6,300 square foot facility and 2 x 4 MW/4.5 MVA smart inverters are on a concrete pad adjacent to the BESS facility. The project will evaluate the capabilities of the BESS to improve grid performance and assist in the integration of large-scale intermittent generation, e.g., wind. Project performance was measured by 13 specific operational uses: providing voltage support and grid stabilization, decreasing transmission losses, diminishing congestion, increasing system reliability, deferring transmission investment, optimizing renewable-related transmission, providing system capacity and resources adequacy, integrating renewable energy (smoothing), shifting wind generation output, frequency regulation, spin/non-spin replacement reserves, ramp management, and energy price arbitrage. Most of the operations either shift other generation resources to meet peak load and other electricity system needs with stored electricity, or resolve grid stability and capacity concerns that result from the interconnection of intermittent generation. SCE also demonstrated the ability of lithium ion battery storage to provide nearly instantaneous maximum capacity for supply-side ramp rate control to minimize the need for fossil fuel-powered back-up generation. The project began in October, 2010 and will continue through December, 2016.

25 ENERGY STORAGE↗

AI-Enhanced Co-Design for Next-Generation Microelectronics: Innovating Innovation (Workshop Report)

The Artificial Intelligence Enhanced Co-Design for Next Generation Microelectronics virtual workshop was held April 4-5, 2023, and attended by subject matter experts from universities, industry, and national laboratories. This was the third in a series of workshops to motivate the research community to identify and address major challenges facing microelectronics research and production. The 2023 workshop focused on a set of topics from materials to computing algorithms, and included discussions on relevant federal legislation and such as the Creating Helpful Incentives to Produce Semiconductors and Science Act (CHIPS Act) which was signed into law in the summer of 2022. Talks at the workshop included edge computing in radiation environments, new materials for neuromorphic computing, advanced packaging for microelectronics, and new AI techniques. We also received project updates from several of the Department of Energy (DOE) microelectronics co-design projects funded in the fall of 2021, and from three of the Energy Frontier Research Centers (EFRCs) that had been funded in the fall of 2022. The workshop also conducted a set of breakout discussions around the five principal research directions (PRDs) from the 2018 Department of Energy workshop report: 1) define innovative material, device, and architecture requirements driven by applications, algorithms, and software; 2) revolutionize memory and data storage; 3) re-imagine information flow unconstrained by interconnects; 4) redefine computing by leveraging unexploited physical phenomena; 5) reinvent the electricity grid through new materials, devices, and architectures. We tasked each breakout group to consider one primary PRD (and other PRDs as relevant topics arose during discussions) and to address questions such as whether the research community has embraced co-design as a methodology and whether new developments at any level of innovation from materials to programming models requires the research community to reevaluate the PRDs developed back in 2018.

97 MATHEMATICS AND COMPUTING↗

High temperature, low mass solar blanket development

This paper presents methods of incorporating ultrathin silicon solar cells into photovoltaic blankets for space applications. This type of cell has the highest power-to-mass ratio and best performance under space radiation of any silicon solar cell. Interconnect materials and designs, and the results of the investigation of the applicability of parallel-gap resistance welding for interconnecting ultrathin cells are discussed. Data relating contact pull strength and cell electrical degradation to welding parameters such as time, voltage, and pressure are presented. Methods for bonding ultrathin cells to flexible substrates and for bonding thin covers to these cells are described, and the results of vacuum thermal cycling and thermal soak tests on prototype ultrathin cell test coupons are included.

Mesch, H. G.↗

InP tunnel junction for InGaAs/InP tandem solar cells

Chemical beam epitaxy (CBE) has been shown to allow the growth of high quality materials with reproducible complex compositional and doping profiles. The main advantage of CBE compared to metalorganic chemical vapor deposition (MOCVD), the most popular technique for InP-based photovoltaic device fabrication, is the ability to grow high purity epilayers at much lower temperatures (450-530 C). We have previously shown that CBE is perfectly suited toward the fabrication of complex photovoltaic devices such as InP/InGaAs monolithically integrated tandem solar cells, because its low process temperature preserves the electrical characteristics of the InGaAs tunnel junction commonly used as an ohmic interconnect. In this work using CBE for the fabrication of optically transparent (with respect to the bottom cell) InP tunnel diodes is demonstrated. Epitaxial growth were performed in a Riber CBE 32 system using PH3 and TMIn as III and V precursors. Solid Be (p-type) and Si (n-type) have been used as doping sources, allowing doping levels up to 2 x 10(exp -19)/cu cm and 1 x 10(exp -19)/cu cm for n and p type respectively. The InP tunnel junction characteristics and the influence of the growth's conditions (temperature, growth rate) over its performance have been carefully investigated. InP p(++)/n(++) tunnel junction with peak current densities up to 1600 A/sq cm and maximum specific resistivities (V(sub p)/I(sub p) - peak voltage to peak current ratio) in the range of 10(exp -4) Omega-sq cm were obtained. The obtained peak current densities exceed the highest results previously reported for their lattice matched counterparts, In(0.53)Ga( 0.47)As and should allow the realization of improved minimal absorption losses in the interconnect InP/InGaAs tandem devices for Space applications. Owing to the low process temperature required for the top cell, these devices exhibit almost no degradation of its characteristics after the growth of subsequent thick InP layer suggesting minimal doping cross diffusion in the narrow space-charge region (approximately 1-5 nm) of the device. The fabrication of tandem devices using InP tunnel diodes as interconnect is in progress and will be reported at the conference.

Vilela, M. F.↗