Search NASA⌕ Search

SEARCH · Search NASA

Results for “environmental sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Corrective Action Investigation Plan for Corrective Action Unit 561: Waste Disposal Areas, Nevada Test Site, Nevada with ROTC 1, Revision 0

Corrective Action Unit (CAU) 561 is located in Areas 1, 2, 3, 5, 12, 22, 23, and 25 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 561 is comprised of the 10 corrective action sites (CASs) listed below: • 01-19-01, Waste Dump • 02-08-02, Waste Dump and Burn Area • 03-19-02, Debris Pile • 05-62-01, Radioactive Gravel Pile • 12-23-09, Radioactive Waste Dump • 22-19-06, Buried Waste Disposal Site • 23-21-04, Waste Disposal Trenches • 25-08-02, Waste Dump • 25-23-21, Radioactive Waste Dump • 25-25-19, Hydrocarbon Stains and Trench These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on April 28, 2008, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 561. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS. The scope of the Corrective Action Investigation for CAU 561 includes the following activities: • Move surface debris and/or materials, as needed, to facilitate sampling. • Conduct radiological surveys. • Perform exploratory excavations. • Perform field screening. • Collect and submit environmental samples for laboratory analysis to determine the nature and extent of any contamination released by each CAS. • Collect samples of source material to determine the potential for a release. • Collect samples of potential remediation wastes. • Collect quality control samples.

54 ENVIRONMENTAL SCIENCES↗

Synthesis of Functionalized Superparamagnetic Iron Oxide Nanoparticles from a Common Precursor and their Application as Heavy Metal and Actinide Sorbents

We describe the use of a simple and versatile technique to generate a series of ligand stabilized iron oxide nanoparticles containing different functionalities with specificities toward heavy metals and actinides at the periphery of the stabilizing ligand shell from a common, easy to synthesize precursor nanoparticle. The resulting nanoparticles are designed to contain affinity ligands that make them excellent sorbent materials for a variety of heavy metals from contaminated aqueous systems such as river water and ground water as well as actinides from clinical samples such as blood and urine. Functionalized superparamagnetic nanoparticles make ideal reagents for extraction of heavy metal and actinide contaminants from environmental and clinical samples since they are easily removed from the media once bound to the contaminant by simply applying a magnetic field. In addition, these engineered nanomaterials have an inherently high active surface area (often > 100 m2/g) making them ideal sorbent materials for these types of applications

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Making and using porous acrylonitrile-based hydrogel particles to treat water

Novel compositions of matter synthesized from acrylonitrile and crosslinker, and subsequently coated with various hydrophilic monomers, can be used in the remediation of uranyl ions from groundwater, drinking water, or wastewater and as part of a system for measurement of uranium in environmental and biological samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supplemental Environmental Projects - Accord Pueblo Outreach: Storm Water Sampling Equipment Transfer to Pueblo of Santa Clara

A Settlement Agreement and Stipulated Final Order (Settlement Agreement) between the New Mexico Environment Department (NMED), U.S. Department of Energy (DOE), and Los Alamos National Security, LLC (LANS), collectively, the Parties, for the purposes of resolving Compliance Order No. HWB-14-20 (the Compliance Order), issued on December 6, 2014, related to Los Alamos National Laboratory (LANL) resulted in the development of five Supplemental Environmental Projects (SEPs). One of these SEPs is the Accord Pueblo Outreach.

54 ENVIRONMENTAL SCIENCES↗

Supplemental Environmental Projects - Accord Pueblo Outreach: Storm Water Sampling Equipment Transfer to Pueblo of Cochiti

A Settlement Agreement and Stipulated Final Order (Settlement Agreement) between the New Mexico Environment Department (NMED), U.S. Department of Energy (DOE), and Los National Security, LLC (LANS, collectively, the Parties, for the purposes of resolving Compliance Order No. HWB-14-20 (the Compliance Order), issued of December 6, 2014, related to Los Alamos National Laboratory (LANL or the Laboratory) resulted in the development of five Supplemental Environmental Projects (SEPs). An element of one of these SEPs is the Accord Pueblo Outreach.

54 ENVIRONMENTAL SCIENCES↗

Supplemental Environmental Projects - Accord Pueblo Outreach: Storm Water Sampling Equipment Transfer to Pueblo of Jemez

A Settlement Agreement and Stipulated Final Order (Settlement Agreement) between the New Mexico Environment Department (NMED), U.S. Department of Energy (DOE), and Los National Security, LLC (LANS, collectively, the Parties, for the purposes of resolving Compliance Order No. HWB-14-20 (the Compliance Order), issued of December 6, 2014, related to Los Alamos National Laboratory (LANL or the Laboratory) resulted in the development of five Supplemental Environmental Projects (SEPs). An element of one of these SEPs is the Accord Pueblo Outreach.

54 ENVIRONMENTAL SCIENCES↗

Supplemental Environmental Projects - Accord Pueblo Outreach: Storm Water Sampling Equipment Transfer to Pueblo of San Ildefonso

A Settlement Agreement and Stipulated Final Order (Settlement Agreement) between the New Mexico Environment Department (NMED), U.S. Department of Energy (DOE), and Los National Security, LLC (LANS, collectively, the Parties, for the purposes of resolving Compliance Order No. HWB-14-20 (the Compliance Order), issued of December 6, 2014, related to Los Alamos National Laboratory (LANL or the Laboratory) resulted in the development of five Supplemental Environmental Projects (SEPs). An element of one of these SEPs is the Accord Pueblo Outreach.

54 ENVIRONMENTAL SCIENCES↗

Groundwater and Leachate Monitoring and Sampling at ERDF, CY 2009

This document reports the findings of the groundwater and leachate monitoring and sampling at the Environmental restoration Disposal Facility for calendar year 2009. The purpose of this annual monitoring report is to evaluate the conditions of and identify trends for groundwater beneath the ERDF and report leachate results in fulfillment of the requirements specified in the ERDF ROD and the ERDF Amended ROD.

54 ENVIRONMENTAL SCIENCES↗

Spacelab Charcoal Analyses

This report describes analytical methods and results obtained from chemical analysis of 31 charcoal samples in five sets. Each set was obtained from a single scrubber used to filter ambient air on board a Spacelab mission. Analysis of the charcoal samples was conducted by thermal desorption followed by gas chromatography/mass spectrometry (GC/MS). All samples were analyzed using identical methods. The method used for these analyses was able to detect compounds independent of their polarity or volatility. In addition to the charcoal samples, analyses of three Environmental Control and Life Support System (ECLSS) water samples were conducted specifically for trimethylamine.

Slivon, L. E.↗

Making an s1G Self-Preserving Environmental DNA (eDNA) Filter from Sustainable Materials

Environmental DNA (eDNA) sampling of aquatic environments is a powerful new tool for resource managers to use in detecting the presence of rare and endangered species. The use of eDNA for species detection is quickly becoming an industry-standard methodology in environmental science, and the technology sector is moving quickly to create purpose-built tools for eDNA sampling. Smith-Root, Inc. pioneered the new technology of self-preserving eDNA filters that automatically preserve the DNA captured on filters by desiccating the internal filter membrane. This capability saves the sampling technician significant time in the field and drastically reduces the potential for sample contamination. One main constraint of this new technology, however, is the necessity of single-use plastics for eDNA sampling. Single-use designs are employed because sampling equipment must be devoid of potential contaminating DNA, and the time required to sterilize equipment is often not cost-effective for practitioners. Thus, this technology is creating a significant new source of plastic waste—something that eDNA practitioners, and society, would like to avoid. This project explores the use of alternative bio based polymers and composites as replacements for incumbent industrial standards for eDNA filtration systems, with an emphasis on ease of processing and biodegradable options. 8 candidate materials, 3 for the top filter housing and 5 for the bottom filter housing, were investigated to replace incumbent housing materials. Of the 8 candidates, 2 materials were identified for future investigation which met performance requirements, were bio-based and could potentially offer better disposal options like soil degradation or composting, features sought by the customers of these products. The top housing candidate, material 1, has comparable performance to the incumbent material and equally manufacturable. The bottom housing candidate, material 6, improved desiccation performance by 81% after 1 hour in comparison to the incumbent material, is 100% bio-based, compostable and can be sourced domestically throughout the U.S.A.

36 MATERIALS SCIENCE↗

Corrective Action Investigation Plan for Corrective Action Unit 370: T-4 Atmospheric Test Site, Nevada Test Site, Nevada with ROTC-1, Revision 0

Corrective Action Unit (CAU) 370 is located in Area 4 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 370 is comprised of Corrective Action Site (CAS) 04-23-01, Atmospheric Test Site T-4. This site is being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and/or implement a corrective action. Additional information will be obtained by conducting a corrective action investigation (CAI) before evaluating corrective action alternatives and selecting the appropriate corrective action for this CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The investigation results may also be used to evaluate improvements in the Soils Project strategy to be implemented. The site will be investigated based on the data quality objectives (DQOs) developed on December 10, 2007, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Desert Research Institute; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 370. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to the CAS. The scope of the CAI for CAU 370 includes the following activities: • Move surface debris and/or materials, as needed, to facilitate sampling. • Conduct radiological surveys. • Perform field screening. • Collect and submit environmental samples for laboratory analysis to determine whether contaminants of concern are present. • If contaminants of concern are present, collect samples to define the extent of the contamination. • Collect samples of investigation-derived waste including debris deemed to be potential source material, as needed, for waste management purposes.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Investigation Plan for Corrective Action Unit 562: Waste Systems Nevada Test Site, Nevada, Revision 0

Corrective Action Unit 562 is located in Areas 2, 23, and 25 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 562 is comprised of the 13 corrective action sites (CASs) listed below: • 02-26-11, Lead Shot • 02-44-02, Paint Spills and French Drain • 02-59-01, Septic System • 02-60-01, Concrete Drain • 02-60-02, French Drain • 02-60-03, Steam Cleaning Drain • 02-60-04, French Drain • 02-60-05, French Drain • 02-60-06, French Drain • 02-60-07, French Drain • 23-60-01, Mud Trap Drain and Outfall • 23-99-06, Grease Trap • 25-60-04, Building 3123 Outfalls These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on December 11, 2008, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 562. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS. The scope of the corrective action investigation for CAU 562 includes the following activities: • Move surface debris and/or materials, as needed, to facilitate sampling. • Conduct radiological surveys. • Perform field screening. • Collect and submit environmental samples for laboratory analysis to determine the nature and extent of any contamination released by each CAS. • Collect samples of source material to determine the potential for a release. • Collect samples of potential remediation wastes. • Collect quality control samples. This Corrective Action Investigation Plan has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; DOE, Environmental Management; U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996; as amended February 2008). Under the Federal Facility Agreement and Consent Order, this Corrective Action Investigation Plan will be submitted to the Nevada Division of Environmental Protection for approval. Fieldwork will be conducted following approval of the plan.

54 ENVIRONMENTAL SCIENCES↗

Environmental Monitoring Plan (Revision 6)

The purpose of environmental monitoring is to promote the early identification of, and response to, potential adverse environmental impacts associated with Lawrence Livermore National Laboratory (LLNL) operations. Environmental monitoring supports the Integrated Safety Management System (ISMS), International Organization for Standardization (ISO) 14001 Environmental Management Systems standard, and U. S. Department of Energy (DOE) Order 458.1, Radiation Protection of the Public and the Environment. Specifically, environmental monitoring enables LLNL to detect, characterize, and respond to releases from LLNL activities; assess impacts; estimate dispersal patterns in the environment; characterize the pathways of exposure to members of the public; characterize the exposures and doses to individuals and to the population; and to evaluate the potential impacts to the biota in the vicinity of LLNL. Environmental monitoring is also a major component of compliance demonstration for permits and other regulatory requirements. The Environmental Monitoring Plan (EMP) addresses the sample collection and analytical work supporting environmental monitoring to ensure the following: (1) A consistent system for collecting, assessing, and documenting environmental data of known and documented quality; (2) A validated and consistent approach for sampling and analysis of samples to ensure laboratory data meets program-specific needs and requirements within the framework of a performance-based approach for analytical laboratory work; and (3) An integrated sampling approach to avoid duplicative data collection. LLNL prepares the EMP because it provides an organizational framework for ensuring that environmental monitoring work, which is integral to the implementation of LLNL's Environmental Management System, is conducted appropriately. Furthermore, the Environmental Monitoring Plan helps LLNL ensure compliance with DOE Order 231.1 Change 2, Environment, Safety and Health Reporting, which require the publication of an annual report that characterizes the site's environmental management performance. To summarize, the general regulatory drivers for this environmental monitoring plan are ISO 14001, DOE Order 458.1, and DOE Order 231.1. The environmental monitoring addressed by this plan includes preoperational characterization and assessment, effluent and surveillance monitoring, and permit and regulatory compliance monitoring. Additional environmental monitoring is conducted at LLNL as part of compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA, also known as Superfund). LLNL coordinates its ground water surveillance monitoring program with the CERCLA monitoring program to gain sampling efficiencies.

54 ENVIRONMENTAL SCIENCES↗

Environmental Monitoring Plan, Revision 5

The purpose of environmental monitoring is to promote the early identification of, and response to, potential adverse environmental impacts associated with Lawrence Livermore National Laboratory (LLNL) operations. Environmental monitoring supports the Integrated Safety Management System (ISMS), International Organization for Standardization (ISO) 14001 Environmental Management Systems standard, and U. S. Department of Energy (DOE) Order 450.1A, Environmental Protection Program. Specifically, in conformance with DOE Order 450.1A, Attachment 1, paragraph 1(b)(5), environmental monitoring enables LLNL to detect, characterize, and respond to releases from LLNL activities; assess impacts; estimate dispersal patterns in the environment; characterize the pathways of exposure to members of the public; characterize the exposures and doses to individuals and to the population; and to evaluate the potential impacts to the biota in the vicinity of LLNL. Environmental monitoring also serves to demonstrate compliance with permits and other regulatory requirements. The Environmental Monitoring Plan (EMP) addresses the sample collection and analytical work supporting environmental monitoring to ensure the following: (1) A consistent system for collecting, assessing, and documenting environmental data of known and documented quality. (2) A validated and consistent approach for sampling and analysis of samples to ensure laboratory data meets program-specific needs and requirements within the framework of a performance-based approach for analytical laboratory work. (3) An integrated sampling approach to avoid duplicative data collection. Until its cancellation in January 2003, DOE Order 5400.1 required the preparation of an environmental monitoring plan. Neither DOE Order 450.1A nor the ISO 14001 standard are as prescriptive as DOE Order 5400.1, in that neither expressly requires an EMP. However, LLNL continues to prepare the EMP because it provides an organizational framework for ensuring that this work, which is integral to the implementation of LLNL's Environmental Management System, is conducted appropriately. Furthermore, the Environmental Monitoring Plan helps LLNL ensure compliance with DOE Order 5400.5, Radiation Protection of the Public and the Environment, and DOE Order 231.1 Change 2, Environment, Safety and Health Reporting, which require the publication of an annual report that characterizes the site's environmental management performance. To summarize, the general regulatory drivers for this environmental monitoring plan are ISO 14001, DOE Order 450.1A, DOE Order 5400.5, and DOE Order 231.1. The environmental monitoring addressed by this plan includes preoperational characterization and assessment, effluent and surveillance monitoring, and permit and regulatory compliance monitoring. Additional environmental monitoring is conducted at LLNL as part of compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA, also known as Superfund). LLNL coordinates its ground water surveillance monitoring program with the CERCLA monitoring program to gain sampling efficiencies. (See LLNL [1992] and LLNL [2008] for information about LLNL's CERCLA activities).

54 ENVIRONMENTAL SCIENCES↗

Characterization of Senecavirus A Isolates Collected From the Environment of U.S. Sow Slaughter Plants

Vesicular disease caused by Senecavirus A (SVA) is clinically indistinguishable from foot-and-mouth disease (FMD) and other vesicular diseases of swine. When a vesicle is observed in FMD-free countries, a costly and time-consuming foreign animal disease investigation (FADI) is performed to rule out FMD. Recently, there has been an increase in the number of FADIs and SVA positive samples at slaughter plants in the U.S. The objectives of this investigation were to: (1) describe the environmental burden of SVA in sow slaughter plants; (2) determine whether there was a correlation between PCR diagnostics, virus isolation (VI), and swine bioassay results; and (3) phylogenetically characterize the genetic diversity of contemporary SVA isolates. Environmental swabs were collected from three sow slaughter plants (Plants 1-3) and one market-weight slaughter plant (Plant 4) between June to December 2020. Of the 426 samples taken from Plants 1-3, 304 samples were PCR positive and 107 were VI positive. There was no detection of SVA by PCR or VI at Plant 4. SVA positive samples were most frequently found in the summer (78.3% June-September, vs. 59.4% October-December), with a peak at 85% in August. Eighteen PCR positive environmental samples with a range of C t values were selected for a swine bioassay: a single sample infected piglets ( n = 2). A random subset of the PCR positive samples was sequenced; and phylogenetic analysis demonstrated co-circulation and divergence of two genetically distinct groups of SVA. These data demonstrate that SVA was frequently found in the environment of sow slaughter plants, but environmental persistence and diagnostic detection was not indicative of whether a sampled was infectious to swine. Consequently, a more detailed understanding of the epidemiology of SVA and its environmental persistence in the marketing chain is necessary to reduce the number of FADIs and aide in the development of control measures to reduce the spread of SVA.

59 BASIC BIOLOGICAL SCIENCES↗

A systematic approach to resolve high impedance of multifunctional energy storage composites

Previous work has proposed and characterized the structural and electrical performance of Multifunctional Energy Storage Composite (MESC) structures: structural elements with embedded lithium-ion batteries which were developed by the Structures and Composite Laboratory (SACL) at Stanford University. This work conducts a comprehensive parametric study over the design variables in the manufacturing process to determine the root cause of increased DC impedance compared to commercial pouch cell batteries. Several MESC samples were assembled under various controlled environmental temperatures and pressures. The samples underwent Hybrid Peak Pulse Characterization (HPPC) to approximate the DC impedance as a function of state of charge (SOC). Failure limits of the battery with respect to assembly temperature and pressure were tested, and an MESC manufacturing simulation model was constructed in Abaqus to validate the manufacturing limits. Samples assembled without enough temperature or pressure failed due to a lack of structural integrity or hermetic seal. Conversely, samples which underwent elevated temperatures and pressures resulted in high DC impedance due to nonuniform electrolyte wetting. This work resolves the primary concern of MESC by achieving comparable DC impedance to commercial pouch cells of the same chemistry and testing procedure.

25 ENERGY STORAGE↗

HYDROGEN EFFECTS ON FRACTURE TOUGHNESS OF TYPE 316L STAINLESS STEEL FROM 175 K TO 425 K

The effects of hydrogen on the fracture-toughness properties of Type 316L stainless steel from 175 K to 425 K were measured. Fracture-toughness samples were fabricated from Type 316L stainless steel forgings and hydrogen-charged with hydrogen at 34 MPa and 623 K for two weeks prior to testing. The effect of hydrogen on the J-Integral vs. crack extension behavior was measured at various temperatures by fracturing non-charged and hydrogen-charged samples in an environmental chamber. Hydrogen-charged steels had lower toughness values than non-charged ones, but still retained good toughness properties. The fracture-toughness values of hydrogen-charged samples tested near ambient temperature were about 70% of non-charged values. For hydrogen-charged samples tested at 225 K and 425 K, the fracture-toughness values were 50% of the non-charged values. In all cases, fracture occurred by microvoid nucleation and coalescence, although the hydrogen-charged samples had smaller and more closely spaced microvoids. The results suggest that hydrogen effects on toughness are greater at 225 K than they are at ambient temperature because of strain-induced martensite formation. At 425 K, the hydrogen effects on toughness are greater than they are at ambient temperature because of the higher mobility of hydrogen.

08 HYDROGEN↗