Search NASA⌕ Search

SEARCH · Search NASA

Results for “error impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Arctic sea ice leads from advanced very high resolution radiometer images

A large number of advanced very high resolution radiometer (AVHRR) images from throughout 1989 are analyzed to determine lead characteristics. The units of analysis are square 200-km cells, and there are 270 such cells in the data set. Clouds are masked manually. Leads determine from images of the potential open water delta, a scaled version of the surface temperature or albedo that weights thin ice by its thermal or brightness impact. The lead fraction is determined as the mean delta, the monthly mean lead fraction ranges from 0.02 in winter to 0.06 in summer in the central Arctic and is near 0.08 in the winter in the peripheral seas. A method of accounting for lead width sampling errors due to the finite sample areas is introduced. In the central Arctic the observed mean lead width for a threshold of delta = 0.1 ranges from 2 or 3 km (near the resolution of the instrument) in the winter to 6 km in the summer. In the peripheral seas it is about 5 km in the winter. Width distributions are often more heavily weighted in the tail than exponential distributions and are well approximated by a power law. The along-track, number density power law N = aw(exp -6) has a mean exponent of b = 1.60 (standard deviation 0.18) and shows some seasonal variability. Mean floe widths in the central Arctic are 40 to 50 km in the winter, dropping to about 10 km in the summer. For floes the power law has a mean exponent of 0.93 and exhibits a clearer annual cycle. Lead orientation is determined with a method based on the direction of maximum extent.

Lindsay, R. W.↗

Error field correction strategies in preparation to MAST-U operation

In magnetic fusion devices, unwanted non-axisymmetric magnetic field perturbations, known as error fields (EF), can have detrimental effects on plasma stability and confinement. Such EFs may originate from several sources, such as axi-symmetric coil misalignments, coil feeds, 3D structures in the wall surrounding the plasma, presence of ferromagnetic materials near the plasma surface, blanket materials in future devices. To minimize their impact on plasma performance and on the available operational space, it is important to identify the EF sources and develop EF control strategies. MAST Upgrade (MAST-U) is a spherical tokamak which will operate in the near future after a series of enhancements from the previous MAST experiment. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal eld (P) and divertor (D) coils. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal field (P) and divertor (D) coils, whose magnetic eld measurements were available when writing this paper. Such measurements reveal that P and D coils are 3D deformed and thus are responsible for intrinsic EFs, with mainly n=1 and n=2 toroidal mode numbers. In preparation to MAST-U operation, both passive and active EF control strategies have been adopted for n=1 and n=2 EFs compensation. Passive EF control consisted of installing finely each D and P coil within MAST-U device so as to minimize the intrinsic n=1 EF amplitude. The optimal coil alignment has been determined based on magnetic eld measurements and the corresponding 3D electro-magnetic modelling, and envisaged coil shift and tilt of 3.2 mm and 0.7 mrad, respectively, in the case of P coil named P4. Conversely, active control will be use during MAST-U operation to reduce the n=2 EF which is associated mainly with P4 and P5, as well. Since these coils have been re-used from the MAST device, studies attempting n=2 EF control, based on MAST plasmas, have been modelled utilizing the MARS-F code to interpret experimental results in MAST and to give hints for future n=2 EF control studies in MAST-U. Here, a model-based control set for n=2 EF control has been identified which would allow for the minimization of rotation braking, of the resonant magnetic field at the q=2 and of the plasma displacement in MAST-U, simultaneously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contact Versus Non-Contact Measurement of a Helicopter Main Rotor Composite Blade

The dynamic characterization of lightweight structures is particularly complex as the impact of the weight of sensors and instrumentation (cables, mounting of exciters...) can distort the results. Varying mass loading or constraint effects between partial measurements may determine several errors on the final conclusions. Frequency shifts can lead to erroneous interpretations of the dynamics parameters. Typically these errors remain limited to a few percent. Inconsistent data sets however can result in major processing errors, with all related consequences towards applications based on the consistency assumption, such as global modal parameter identification, model-based damage detection and FRF-based matrix inversion in substructuring, load identification and transfer path analysis [1]. This paper addresses the subject of accuracy in the context of the measurement of the dynamic properties of a particular lightweight structure. It presents a comprehensive comparative study between the use of accelerometer, laser vibrometer (scanning LDV) and PU-probe (acoustic particle velocity and pressure) measurements to measure the structural responses, with as final aim the comparison of modal model quality assessment. The object of the investigation is a composite material blade from the main rotor of a helicopter. The presented results are part of an extensive test campaign performed with application of SIMO, MIMO, random and harmonic excitation, and the use of the mentioned contact and non-contact measurement techniques. The advantages and disadvantages of the applied instrumentation are discussed. Presented are real-life measurement problems related to the different set up conditions. Finally an analysis of estimated models is made in view of assessing the applicability of the various measurement approaches for successful fault detection based on modal parameters observation as well as in uncertain non-deterministic numerical model updating.

36 MATERIALS SCIENCE↗

Tensor-decomposition techniques for ab initio nuclear structure calculations: From chiral nuclear potentials to ground-state energies

The computational resources needed to generate the ab initio solution of the nuclear many-body problem for increasing mass number and/or accuracy necessitates innovative developments to improve upon (i) the storage of many-body operators and (ii) the scaling of many-body methods used to evaluate nuclear observables. The storing and efficient handling of many-body operators with high particle ranks is currently one of the major bottlenecks limiting the applicability range of ab initio studies with respect to mass number and accuracy. Recently, the application of tensor decomposition techniques to many-body tensors has proven highly beneficial to reduce the computational cost of ab initio calculations in quantum chemistry and solid-state physics. The impact of applying state-of-the-art tensor factorization techniques to modern nuclear Hamiltonians derived from chiral effective field theory is investigated. Subsequently, the error induced by the tensor decomposition of the input Hamiltonian on ground-state energies of closed-shell nuclei calculated via second-order many-body perturbation theory is benchmarked. The first proof-of-principles application of tensor-decomposition techniques to the nuclear Hamiltonian is performed. Two different tensor formats are investigated by systematically benchmarking the approximation error on matrix elements stored in various bases of interest. The analysis is achieved while including normal-ordered three-nucleon interactions that are nowadays used as input to the most advanced ab initio calculations in medium-mass nuclei. With the aid of the factorized Hamiltonian, the second-order perturbative correction to ground-state energies is decomposed and the scaling properties of the underlying tensor network are discussed. The employed tensor formats are found to lead to an efficient data compression of two-body matrix elements of the nuclear Hamiltonian. In particular, the sophisticated tensor hypercontraction scheme yields low tensor ranks with respect to both harmonic-oscillator and Hartree-Fock single-particle bases. It is found that the tensor rank depends on the two-body total angular momentum J for which one performs the decomposition, which is itself directly related to the sparsity of the corresponding tensor. Furthermore, including normal-ordered two-body contributions originating from three-body interactions does not compromise the efficient data compression. Ultimately, the use of factorized matrix elements authorizes controlled approximations of the exact second-order ground-state energy corrections. In particular, a small enough error is obtained from low-rank factorizations in He4,O16, and Ca40. It is presently demonstrated that tensor-decomposition techniques can be efficiently applied to systematically approximate the nuclear many-body Hamiltonian in terms of lower-rank tensors. Beyond the input Hamiltonian, tensor-decomposition techniques can be envisioned to scale down the cost of state-of-the-art nonperturbative many-body methods in order to extend ab initio studies to (i) higher precisions, (ii) larger masses, and (iii) nuclei of doubly open-shell character.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical deep space communication via relay satellite

The possible use of an optical for high rate data transmission from a deep space vehicle to an Earth-orbiting relay satellite while RF links are envisioned for the relay to Earth link was studied. A preliminary link analysis is presented for initial sizing of optical components and power levels, in terms of achievable data rates and feasible range distances. Modulation formats are restricted to pulsed laser operation, involving bot coded and uncoded schemes. The advantage of an optical link over present RF deep space link capabilities is shown. The problems of acquisition, pointing and tracking with narrow optical beams are presented and discussed. Mathematical models of beam trackers are derived, aiding in the design of such systems for minimizing beam pointing errors. The expected orbital geometry between spacecraft and relay satellite, and its impact on beam pointing dynamics are discussed.

Gagliardi, R. M.↗

TPSAS-NF1676L-32030-DND

Composite structures are often difficult to inspect due to the anisotropic nature of the material systems and the range of flaws and defects that can arise in the manufacturing process. NASA?s Advanced Composites Project, a public-private partnership between government, universities and industry, seeks to address improved methods, tools, and protocols to reduce the development and certification timeline for composite materials and structures. The rapid inspection of composites is one of the three focused research areas of the project. One deliverable of the project is to develop an NDE Methods and Capabilities Handbook. This Handbook provides a publically available guidance document that facilitates the selection of appropriate NDE techniques and provides recommended protocols for detecting and characterizing common flaw types in solid laminate polymer matrix composite (PMC) structures. The Handbook will reduce the time required to develop qualified inspection processes for composite aircraft structures during the development, certification, and manufacturing phases by providing a reference that helps minimize trial and error and provides guidance on best practices, techniques, and settings, for specific flaw types and geometries. The Handbook will include an NDE Guidance Matrix that provides an applicability rating for NDE techniques as they apply to given flaw types. NDE techniques will include, but is not limited to ultrasound, laser based ultrasound, infrared thermography, and x-ray CT. Flaw types will include, but are not limited to porosity, delamination, voids, AFP defects and impact damage. The Handbook will contain details that support the applicability rating including, but not limited to, specimen details, inspection parameters, data analysis techniques, inspection efficiency (speed & cost), and limitations. This presentation will describe key Handbook activities with examples of the techniques and flaw types examined by the Advanced Composite Consortium members.

Patricia A Howell↗

Analysis of the Accuracy of Actuation Electronics in the Laser Interferometer Space Antenna Pathfinder

The Laser Interferometer Space Antenna Pathfinder (LPF) main observable, labelled∆g, is the differential force per unit mass acting on the two test masses in free fall condition, after the contribution of all non-gravitational forces have been compensated. At low frequencies the differential force is compensated by an applied electrostatic actuation force,which then must be subtracted from the measured acceleration to obtain∆g. Any inaccuracy in the actuation force contaminates the residual acceleration. This study investigates the accuracy of the electrostatic actuation system and its impact on the LPF main observable. It is shown that the inaccuracy is mainly caused by the rounding errors in the waveform processing and also by the random error caused by the analog to digital converter (ADC) random noise in the control loop. Both errors are one order of magnitude smaller than the resolution of the commanded voltages. We developed a simulator based on the LPF design to compute the close-to-reality actuation voltages and consequently, the resulting actuation forces. The simulator is applied in post-processing the LPF data.

M. Armano↗

Processing behavior evolution of recycled polypropylene: An integrated experimental and Computer-Aided engineering simulation study

Polypropylene (PP) comprises 21% of global plastics production and 18% of plastics waste, yet less than 1% of solid-waste PP is recycled in the United States (U.S.), representing significant environmental and economic challenges. Mechanical recycling, the most prevalent recycling method, subject's materials to thermomechanical stresses, which typically degrade polymer properties, affecting the quality of polymer products. This study replicates the impact of mechanical recycling through multiple extrusion cycles to examine the effects on PP's processing behavior. Dynamic scanning calorimetry (DSC) measurements showed stable melting behavior across all processing conditions, while crystallization analysis exhibited consistent shifts in kinetic parameters. Rheological characterization demonstrated progressive viscosity reductions through successive cycles, particularly pronounced at elevated reprocessing temperatures. Here, the integration of this experimental data into injection molding simulations showed that recycled PP maintains viable processing characteristics. Our findings establish quantitative correlations between processing history and material behavior, enabling optimization of processing parameters directly rather than relying on trial-and-error approaches. While these results reflect idealized recycling conditions with minimal contamination, they provide a framework for understanding fundamental property evolution during mechanical recycling.

42 ENGINEERING↗

3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification

Purpose: To evaluate methods of pretreatment IMRT analysis, using real measurements performed with a commercial 2D detector array, for clinical relevance and accuracy by comparing clinical DVH parameters. Methods: We divided the work into two parts. The first part consisted of six in-phantom tests aimed to study the sensitivity of the different analysis methods. Beam fluences, 3D dose distribution, and DVH of an unaltered original plan were compared to those of the delivered plan, in which an error had been intentionally introduced. The second part consisted of comparing gamma analysis with DVH metrics for 17 patient plans from various sites. Beam fluences were measured with the MapCHECK 2 detector, per-beam planar analysis was performed with the MapCHECK software, and 3D gamma analysis and the DVH evaluation were performed using 3DVH software. Results: In a per-beam gamma analysis some of the tests yielded false positives or false negatives. However, the 3DVH software correctly described the DVH of the plan which included the error. The measured DVH from the plan with controlled error agreed with the planned DVH within 2% dose or 2% volume. We also found that a gamma criterion of 3%/3 mm was too lax to detect some of the forced errors. Global analysis masked some problems, while local analysis magnified irrelevant errors at low doses. Small hotspots were missed for all metrics due to the spatial resolution of the detector panel. DVH analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results, with the exception of very small volume structures such as the eyes and the lenses. Target coverage (D{sub 98} and D{sub 95}) of the measured plan was systematically lower than that predicted by the treatment planning system, while other DVH characteristics varied depending on the parameter and organ. Conclusions: We found no correlation between the gamma index and the clinical impact of a discrepancy for any of the gamma index evaluation possibilities (global, local, 2D, or 3D). Some of the tests yielded false positives or false negatives in a per-beam gamma analysis. However, they were correctly accounted for in a DVH analysis. We also showed that 3DVH software is reliable for our tests, and is a viable method for correlating planar discrepancies with clinical relevance by comparing the measured DVH of target and OAR's with clinical tolerance.

60 APPLIED LIFE SCIENCES↗

Extensive sensitivity study of PWR fuel assay data - 14301

Accurate calculations of the isotopic composition of spent nuclear fuel play a fundamental role in several parts of nuclear energy. An important example is the use of burnup credit in criticality safety analysis, where the results gained from depletion calculations are used to determine the fuel composition in subsequent criticality calculations. The work presented here is a sensitivity study for depletion calculations of high-burnup fuel samples from the Vandellos II PWR that entails an unusually detailed evaluation of assay data. In addition to investigating the impacts of experimental uncertainties on the calculated isotopic composition, the consequences of various modelling approaches are studied to give quantitative estimations of the impact on accuracy. Furthermore, the reactivity of the calculated fuel composition is tracked, because this is the integral characteristic of the irradiated fuel that one is actually interested in for burnup credit applications. While the sensitivity study is performed only for one of the nine experimental samples of the Vandellos II assay data, the lessons learned lead to evaluation models with different levels of model detail for all fuel samples. The results show that the discrepancies between the measured and calculated isotopic compositions are considerably larger than the uncertainties inherent in the measurement and the calculation method would indicate. This is not unexpected, since large discrepancies are a common result of assay data recalculations. However, the unusually extensive sensitivity study performed here allows to exclude some possible sources of error: since the influence of experimental uncertainties like fuel assembly geometry and reactor parameters on the isotopic composition is shown to be small, one valuable conclusion of this study is to focus more on the measurement uncertainties of the chemical assay itself, and the nuclear data that the calculation is based upon. The study also demonstrates that using the reactivity of the depleted fuel as an additional comparison point between measurement and calculation can provide some orientation regarding the importance of the manifold influences on calculation results. Tracking this integral characteristic of the depleted fuel is very helpful in focusing on the actual impact of the depletion calculation uncertainties on criticality safety. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cosmology from cosmic shear with Dark Energy Survey Science Verification data

We present the first constraints on cosmology from the Dark Energy Survey (DES), using weak lensing measurements from the preliminary Science Verification (SV) data. We use 139 square degrees of SV data, which is less than 3% of the full DES survey area. Using cosmic shear 2-point measurements over three redshift bins we find σ 8 (m=0.3) 0.5 = 0:81 ± 0:06 (68% confidence), after marginalising over 7 systematics parameters and 3 other cosmological parameters. Furthermore, we examine the robustness of our results to the choice of data vector and systematics assumed, and find them to be stable. About 20% of our error bar comes from marginalising over shear and photometric redshift calibration uncertainties. The current state-of-the-art cosmic shear measurements from CFHTLenS are mildly discrepant with the cosmological constraints from Planck CMB data. Our results are consistent with both datasets. Our uncertainties are ~30% larger than those from CFHTLenS when we carry out a comparable analysis of the two datasets, which we attribute largely to the lower number density of our shear catalogue. We investigate constraints on dark energy and find that, with this small fraction of the full survey, the DES SV constraints make negligible impact on the Planck constraints. The moderate disagreement between the CFHTLenS and Planck values of σ 8 (Ω m =0.3) 0.5 is present regardless of the value of w.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature induced distortions in space telescope mirrors

In this paper, it is illustrated how measured instantaneous coefficients of thermal expansion (CTE) can be accurately taken into account when modeling the structural behavior of space based optical systems. In particular, the importance of including CTE spatial variations in the analysis of optical elements is emphasized. A comparison is made between the CTE's of three optical materials commonly used in the construction of space mirrors (ULE, Zerodur, and beryllium). The overall impact that selection of any one of these materials has on thermal distortions is briefly discussed. As an example of how temperature dependent spatial variations in thermal strain can be accurately incorporated in the thermo-structural analysis of a precision optical system, a finite element model is developed, which is used to estimate the thermally induced distortions in the Hubble Space Telescope's (HST) primary mirror. In addition to the structural analysis, the optical aberrations due to thermally induced distortions are also examined. These calculations indicate that thermal distortions in HST's primary mirror contribute mainly to defocus error with a relatively small contribution to spherical aberration.

Nied, H. F.↗

An investigation into the milliarcsecond attitude control errors of Hubble Space Telescope

An analysis of the fine pointing errors of the Hubble Space Telescope (HST), in the range from 1 to 15 milliarcsecs, is reported on. The emphasis is on the study of the performance characteristics of the pointing control system, fine guidance sensors and the optical telescope assembly, which produce relative attitude and astrometric measurement errors. Since the first servicing mission in December 1993, the HST relative short term position stability is of the order of 3 milliarcsecs RMS when averaged over 1 min intervals. At this level of accuracy, longer term systematic attitude errors in this range can have a noticeable impact on the telescope's observations. The various error sources are described, including: internal temperature effects; spacecraft structure temperature effects; calibration procedures, and computational inaccuracies.

Bradley, A. J.↗

Three dimensional cluster analysis for atom probe tomography using Ripley’s K-function and machine learning

The size and structure of spatial molecular and atomic clustering can significantly impact material properties and is therefore important to accurately quantify. Ripley’s K-function (K(r)), a measure of spatial correlation, can be used to perform such quantification when the material system of interest can be represented as a marked point pattern. This work demonstrates how machine learning models based on K (r)-derived metrics can accurately estimate cluster size and intra-cluster density in simulated three dimensional (3D) point patterns containing spherical clusters of varying size; over 90% of model estimates for cluster size and intra-cluster density fall within 11% and 18% error of the true values, respectively. These K (r)-based size and density estimates are then applied to an experimental APT reconstruction to characterize MgZn clusters in a 7000 series aluminum alloy. Here we find that the estimates are more accurate, consistent, and robust to user interaction than estimates from the popular maximum separation algorithm. Using K (r) and machine learning to measure clustering is an accurate and repeatable way to quantify this important material attribute.

36 MATERIALS SCIENCE↗

SU-E-J-119: What Effect Have the Volume Defined in the Alignment Clipbox for Cervical Cancer Using Automatic Registration Methods for Cone- Beam CT Verification?

Purpose: To investigate the impact of different clipbox volumes with automated registration techniques using commercially available software with on board volumetric imaging(OBI) for treatment verification in cervical cancer patients. Methods: Fifty cervical cancer patients received daily CBCT scans(on-board imaging v1.5 system, Varian Medical Systems) during the first treatment week and weekly thereafter were included this analysis. A total of 450 CBCT scans were registered to the planning CTscan using pelvic clipbox(clipbox-Pelvic) and around PTV clip box(clipbox- PTV). The translations(anterior-posterior, left-right, superior-inferior) and the rotations(yaw, pitch and roll) errors for each matches were recorded. The setup errors and the systematic and random errors for both of the clip-boxes were calculated. Paired Samples t test was used to analysis the differences between clipbox-Pelvic and clipbox-PTV. Results: . The SD of systematic error(σ) was 1.0mm, 2.0mm,3.2mm and 1.9mm,2.3mm, 3.0mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. The average random error(Σ)was 1.7mm, 2.0mm,4.2mm and 1.7mm,3.4mm, 4.4mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. But, only the SI direction was acquired significantly differences between two image registration volumes(p=0.002,p=0.01 for mean and SD). For rotations, the yaw mean/SD and the pitch SD were acquired significantly differences between clipbox-Pelvic and clipbox-PTV. Conclusion: The defined volume for Image registration is important for cervical cancer when 3D/3D match was used. The alignment clipbox can effect the setup errors obtained. Further analysis is need to determine the optimal defined volume to use the image registration in cervical cancer. Conflict of interest: none.

60 APPLIED LIFE SCIENCES↗

Analysis of solar receiver flux distributions for US/Russian solar dynamic system demonstration on the MIR Space Station

The United States and Russia have agreed to jointly develop a solar dynamic (SD) system for flight demonstration on the Russian MIR space station starting in late 1997. Two important components of this SD system are the solar concentrator and heat receiver provided by Russia and the U.S., respectively. This paper describes optical analysis of the concentrator and solar flux predictions on target receiver surfaces. The optical analysis is performed using the code CIRCE2. These analyses account for finite sun size with limb darkening, concentrator surface slope and position errors, concentrator petal thermal deformation, gaps between petals, and the shading effect of the receiver support struts. The receiver spatial flux distributions are then combined with concentrator shadowing predictions. Geometric shadowing patterns are traced from the concentrator to the target receiver surfaces. These patterns vary with time depending on the chosen MIR flight attitude and orbital mechanics of the MIR spacecraft. The resulting predictions provide spatial and temporal receiver flux distributions for any specified mission profile. The impact these flux distributions have on receiver design and control of the Brayton engine are discussed.

Kerslake, Thomas W.↗

Automated Inadvertent Intruder Application

The Environmental Analysis and Performance Modeling group of Savannah River National Laboratory (SRNL) conducts performance assessments of the Savannah River Site (SRS) low-level waste facilities to meet the requirements of DOE Order 435.1. These performance assessments, which result in limits on the amounts of radiological substances that can be placed in the waste disposal facilities, consider numerous potential exposure pathways that could occur in the future. One set of exposure scenarios, known as inadvertent intruder analysis, considers the impact on hypothetical individuals who are assumed to inadvertently intrude onto the waste disposal site. Inadvertent intruder analysis considers three distinct scenarios for exposure referred to as the agriculture scenario, the resident scenario, and the post-drilling scenario. Each of these scenarios has specific exposure pathways that contribute to the overall dose for the scenario. For the inadvertent intruder analysis, the calculation of dose for the exposure pathways is a relatively straightforward algebraic calculation that utilizes dose conversion factors. Prior to 2004, these calculations were performed using an Excel spreadsheet. However, design checks of the spreadsheet calculations revealed that errors could be introduced inadvertently when copying spreadsheet formulas cell by cell and finding these errors was tedious and time consuming. This weakness led to the specification of functional requirements to create a software application that would automate the calculations for inadvertent intruder analysis using a controlled source of input parameters. This software application, named the Automated Inadvertent Intruder Application, has undergone rigorous testing of the internal calculations and meets software QA requirements. The Automated Inadvertent Intruder Application was intended to replace the previous spreadsheet analyses with an automated application that was verified to produce the same calculations and results. The application was extended to calculate full decay chains for a given parent so that an intruder calculation could be performed without any input from transport calculations, i.e. the intruder analysis was decoupled from groundwater analysis. Once this full decay chain capability was in place, the application was extended to perform a transient calculation of the dose to an intruder over a specified time range, from which the maximum dose in time was determined. Use of the transient calculation to find the maximum dose in time was a significant step forward in automating and simplifying the inadvertent intruder analysis. In conclusion: an automated application has been developed to perform inadvertent intruder analysis for SRS low-level waste facilities. The application performs a transient analysis to find the maximum dose in time for each parent considered. Due to its ease of use and the standardization of input and methods, the Automated Inadvertent Intruder Application has been adopted as standard practice for inadvertent intruder analysis at SRS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring $\nu_\mu$ Disappearance with the MINOS Experiment

The MINOS Experiment consists of two steel-scintillator calorimeters, sampling the long baseline NuMI muon neutrino beam. It was designed to make a precise measurement of the ‘atmospheric’ neutrino mixing parameters, Δm 2 atm . and sin 2 (2 atm .). The Near Detector measures the initial spectrum of the neutrino beam 1km from the production target, and the Far Detector, at a distance of 735 km, measures the impact of oscillations in the neutrino energy spectrum. Work performed to validate the quality of the data collected by the Near Detector is presented as part of this thesis. This thesis primarily details the results of a v μ disappearance analysis, and presents a new sophisticated fitting software framework, which employs a maximum likelihood method to extract the best fit oscillation parameters. The software is entirely decoupled from the extrapolation procedure between the detectors, and is capable of fitting multiple event samples (defined by the selections applied) in parallel, and any combination of energy dependent and independent sources of systematic error. Two techniques to improve the sensitivity of the oscillation measurement were also developed. The inclusion of information on the energy resolution of the neutrino events results in a significant improvement in the allowed region for the oscillation parameters. The degree to which sin 2 (2θ )= 1.0 could be disfavoured with the exposure of the current dataset if the true mixing angle was non-maximal, was also investigated, with an improved neutrino energy reconstruction for very low energy events. The best fit oscillation parameters, obtained by the fitting software and incorporating resolution information were: | Δm 2 | = 2.32 +0.12 -0.08 ×10 -3 eV 2 and sin 2 (2θ ) > 0.90(90% C.L.). The analysis provides the current world best measurement of the atmospheric neutrino mass splitting Δm 2 . The alternative models of neutrino decay and decoherence are disfavoured by 7.8σ and 9.7σ respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗