Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Model reduction for fractured porous media: a machine learning approach for identifying main flow pathways

Discrete fracture networks (DFN) are often used to model flow and transport in fractured porous media. The accurate resolution of flow and transport behavior on a large DFN involving thousands of fractures is computationally expensive. This makes uncertainty quantification studies of quantities of interest such as travel time through the network computationally intractable, since hundreds to thousands of runs of the DFN model are required to get bounds on the uncertainty of the predictions. Prior works on the subject demonstrated that the complexity of a DFN could be reduced by considering a sub-network of it (often termed a “backbone” sub-network), one whose flow and transport properties were then shown to be similar to that of the full network. The technique is tantamount to partitioning the complete set of fractures of a network into two disjoint sets, one of which is the backbone sub-network while the other its complement. It is in this context that we present a system-reduction technique for DFNs using supervised machine learning via a Random Forest Classifier that selects a backbone sub-network from the full set of fractures. The in-sample errors (in terms of precision and recall scores) of the trained classifier are found to be very accurate indicators of the out-of-sample errors, thus exhibiting that the classifier generalizes well to test data. Moreover, this system-reduction technique yields sub-networks as small as 12% of the full DFN that still recover transport characteristics of the full network such as the peak dosage and tailing behavior for late times. Most importantly, the sub-networks remain connected, and their size can be controlled by a single dimensionless parameter. Furthermore, measures of KL-divergence and KS-statistic for the breakthrough curves of the sub-networks with respect to the full network show physically realistic trends in that the measures decrease monotonically as the size of the sub-networks increase. In conclusion, the computational efficiency gained by this technique depends on the size of the sub-network, but large reductions in computational time can be expected for small sub-networks, yielding as much as 90% computational savings for sub-networks that are as small as 10-12% of the full network.

97 MATHEMATICS AND COMPUTING↗

TH-A-19A-04: Latent Uncertainties and Performance of a GPU-Implemented Pre-Calculated Track Monte Carlo Method

Purpose: Assessing the performance and uncertainty of a pre-calculated Monte Carlo (PMC) algorithm for proton and electron transport running on graphics processing units (GPU). While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from recycling a limited number of tracks in the pre-generated track bank is missing from the literature. With a proper uncertainty analysis, an optimal pre-generated track bank size can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pre-generated for electrons and protons using EGSnrc and GEANT4, respectively. The PMC algorithm for track transport was implemented on the CUDA programming framework. GPU-PMC dose distributions were compared to benchmark dose distributions simulated using general-purpose MC codes in the same conditions. A latent uncertainty analysis was performed by comparing GPUPMC dose values to a “ground truth” benchmark while varying the track bank size and primary particle histories. Results: GPU-PMC dose distributions and benchmark doses were within 1% of each other in voxels with dose greater than 50% of Dmax. In proton calculations, a submillimeter distance-to-agreement error was observed at the Bragg Peak. Latent uncertainty followed a Poisson distribution with the number of tracks per energy (TPE) and a track bank of 20,000 TPE produced a latent uncertainty of approximately 1%. Efficiency analysis showed a 937× and 508× gain over a single processor core running DOSXYZnrc for 16 MeV electrons in water and bone, respectively. Conclusion: The GPU-PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty below 1%. The track bank size necessary to achieve an optimal efficiency can be tuned based on the desired uncertainty. Coupled with a model to calculate dose contributions from uncharged particles, GPU-PMC is a candidate for inverse planning of modulated electron radiotherapy and scanned proton beams. This work was supported in part by FRSQ-MSSS (Grant No. 22090), NSERC RG (Grant No. 432290) and CIHR MOP (Grant No. MOP-211360)

07 ISOTOPE AND RADIATION SOURCES↗

Diagnostics of Data-Driven Models: Uncertainty Quantification of PM7 Semi-Empirical Quantum Chemical Method

Abstract We report an evaluation of a semi-empirical quantum chemical method PM7 from the perspective of uncertainty quantification. Specifically, we apply Bound-to-Bound Data Collaboration, an uncertainty quantification framework, to characterize (a) variability of PM7 model parameter values consistent with the uncertainty in the training data and (b) uncertainty propagation from the training data to the model predictions. Experimental heats of formation of a homologous series of linear alkanes are used as the property of interest. The training data are chemically accurate , i.e., they have very low uncertainty by the standards of computational chemistry. The analysis does not find evidence of PM7 consistency with the entire data set considered as no single set of parameter values is found that captures the experimental uncertainties of all training data. A set of parameter values for PM7 was able to capture the training data within ±1 kcal/mol, but not to the smaller level of uncertainty in the reported data. Nevertheless, PM7 was found to be consistent for subsets of the training data. In such cases, uncertainty propagation from the chemically accurate training data to the predicted values preserves error within bounds of chemical accuracy if predictions are made for the molecules of comparable size. Otherwise, the error grows linearly with the relative size of the molecules.

42 ENGINEERING↗

Limitations of Rb-82 weight-adjusted dosing accuracy at low doses

Introduction: Weight-adjusted dosing is important to maintain accurate quantification for dynamic cardiac three-dimensional positron emission tomography (PET). However, the manufacturer of the only Food and Drug Administration approved rubidium-82 (Rb-82) generator (CardioGen-82, Bracco Diagnostics, Inc.) recommends recalibration after each change in dose which is inefficient in a busy clinical PET lab. The objective of this study was to evaluate the accuracy of Rb-82 dosing without this recalibration. Methods: After daily calibration to either 30 mCi (1110 MBq) or 12 mCi (444 MBq), Rb-82 doses between 6 and 45 mCi (222-1665 MBq) were eluted and measured on an external dose calibrator. This was repeated for four generators at weeks 1, 2, or 4 of the generator cycle. The measurements were compared with values reported by the infusion system. Results: For requested doses less than 30 mCi, the measured dose was consistently lower than the requested dose, ranging from −3.2 mCi at 25 mCi to −5.5 mCi at 10 mCi. The error exceeded 10% for doses less than or equal to 26 mCi for the 30 mCi calibration. Residual activity in the infusion system dead volume accounted for the discrepancy between requested and delivered doses for calibration to 30 mCi but not 12 mCi. Conclusions: The CardioGen-82 infusion system is capable of accurate weight-adjusted doses without recalibration for Rb-82 doses as low as 26 mCi when calibrated to 30 mCi. For doses less than 26 mCi, the generator-reported residual activity within the infusion system can be used to correct the delivered dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Post-landing major element quantification using SuperCam laser induced breakdown spectroscopy

The SuperCam instrument on the Perseverance Mars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions and spectra are normalized to minimize signal fluctuations and effects of target distance. In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositions of diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g., silicates, sulfates, carbonates, oxides), more unusual compositions (e.g., Mn ore and sodalite), and replicates of the sintered SuperCam calibration targets (SCCTs) onboard the rover. For each major element (SiO 2 , TiO 2 , Al 2 O 3 , FeO T , MgO, CaO, Na 2 O, K 2 O), the database was subdivided into five “folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining four folds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3 m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep learning approaches for instantaneous laser absorptance prediction in additive manufacturing

Abstract The quantification of absorbed light is essential for understanding laser-material interactions and melt pool dynamics in order to minimize defects in additively manufactured metal components. The geometry of a vapor depression formed during laser melting is closely related to laser energy absorption. This relationship has been observed by the state-of-the-art in situ high-speed synchrotron X-ray visualization and integrating sphere radiometry. These two techniques create a temporally resolved dataset consisting of vapor depression images and corresponding laser absorptance. In this work, we propose two different approaches to predict instantaneous laser absorptance. The end-to-end approach uses deep convolutional neural networks to learn implicit features of X-ray images automatically and predict the laser energy absorptance. The two-stage approach uses a semantic segmentation model to engineer geometric features and predict absorptance using classical regression models. While having distinct advantages, both approaches achieved a consistently low mean absolute error of less than 3.3%.

Chemistry↗

Radiochemical Sensor for Continuous and Remote Liquid Effluents Monitoring

On-line radioactivity monitoring in liquid effluents is an increasing need according to the international regulations at present. Classical activity determination procedures include the sequence of sampling, chemical treatment, measurement and data treatment. These steps are man-power consuming, generate a great amount of waste and introduce an important delay between the potential pollution event and its detection and quantification. To overcome these limitations, we have developed a radiochemical sensor for liquid effluents capable of sending information about the specific activity and volume of a contamination episode to a remote position, on line and continuously. The capabilities of the sensor developed here allow detecting and quantifying contamination pulses of alpha, beta and gamma emitters of different volumes and activity levels included in a continuous stream. Sensor receptor includes two detection systems, one addressed to determine alpha, beta and gamma events and the other to detect sample gamma emissions. Detailed sensor structure will be shown at the conference because patent is in process at this moment. Detection efficiencies (%) obtained in the alpha-beta-gamma system for the range of contamination volumes considered (2- 300 ml) are: 1.6 - 3.2%, for Pu-240; 22.2 - 58.4%, for Sr-90/Y-90 and 8.8 -17.7%, for Cs-134. In the gamma system, values for Cs-134 detection range from 0.6% to 1.3%. Prediction errors obtained show that sensor is capable to detect Sr-90/Y-90 contamination pulses of at least 2 ml and 3 Bq/ml with a relative error lower of 10% in activity and 60% in volume. When contamination pulse increases up to 7 ml, relative errors decrease to 5% for both magnitudes. For Pu-240 and Cs-134, when contamination pulses are of at least 7 ml and 300 Bq/ml, the relative errors obtained in determinations performed in the alpha-beta-gamma system are lower than 10% in activity and 20 % in volume. The same errors are obtained in the gamma system for Cs-134 when contamination pulses are higher than 7 ml and activities up to 1300 Bq/ml. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LaSDI: Parametric Latent Space Dynamics Identification

Enabling fast and accurate physical simulations with data has become an important area of computational physics to aid in inverse problems, design-optimization, uncertainty quantification, and other various decision-making applications. This paper presents a data-driven framework for parametric latent space dynamics identification procedure that enables fast and accurate simulations. The parametric model is achieved by building a set of local latent space model and designing an interaction among them. An individual local latent space dynamics model achieves accurate solution in a trust region. By letting the set of trust region to cover the whole parameter space, our model shows an increase in accuracy with an increase in training data. Herein we introduce two different types of interaction mechanisms, i.e., point-wise and region-based approach. Both linear and nonlinear data compression techniques are used. We illustrate the framework of Latent Space Dynamics Identification (LaSDI) enable a fast and accurate solution process on various partial differential equations, i.e., Burgers’ equations, radial advection problem, and nonlinear heat conduction problem, achieving 0 (100)x speed-up and 0 (1)% relative error with respect to the corresponding full order models.

97 MATHEMATICS AND COMPUTING↗

Leveraging visible and near-infrared spectroelectrochemistry to calibrate a robust model for Vanadium(IV/V) in varying nitric acid and temperature levels

Spectroelectrochemistry and optimal design of experiments can be used to rapidly build accurate models for species quantification and enable a greater level of process awareness. Optical spectroscopy can provide vital elemental and molecular information, but several hurdles must be overcome before it can become a widely adopted analytical method for remote analysis in the nuclear field. Analytes with varying oxidation state, acid concentration, and fluctuating temperature must be efficiently accounted for to minimize time and resources in restrictive hot cell environments. The classic one-factor-at-a-time approach is not suitable for frequent calibration/maintenance operations in this setting. Therefore, a novel alternative was developed to characterize a system containing vanadium(IV/V) (0.01–0.1 M), nitric acid (0.1–4 M), and varying temperatures (20–45 °C). Here, spectroelectrochemistry methods were used to acquire a sample set selected by optimal design of experiments. This new approach allows for the accurate analysis of vanadium and HNO 3 concentration by leveraging UV–Vis–NIR absorption spectroscopy with robust and accurate chemometric models. The top model's root mean squared error of prediction percent values were 3.47%, 4.06%, 3.40%, and 10.9% for V(IV), V(V), HNO 3 , and temperature, respectively. These models, efficiently developed using the designed approach, exhibited strong predictive accuracy for vanadium and acid with varying oxidation states and temperature using only spectrophotometry, which advances current technology for real-world hot cell applications. Additionally, Nernstian analysis of the V(IV/V) standard potential was performed using traditional absorbance methods and multivariate curve resolution (MCR). The successful tests demonstrated that MCR Nernst tests may be valuable in highly convoluted spectral systems to better understand the redox processes' behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-CD-207-02: Quantification of Breast Lesion Compositions Using Low-Dose Spectral Mammography: A Feasibility Study

Purpose: To investigate the feasibility of measuring breast lesion composition with spectral mammography using physical phantoms and bovine tissue. Methods: Phantom images were acquired with a spectral mammography system with a silicon-strip based photon-counting detector. Plastic water and adipose-equivalent phantoms were used to calibrate the system for dual-energy material decomposition. The calibration phantom was constructed in range of 2–8 cm thickness and water densities in the range of 0% to 100%. A non-linear rational fitting function was used to calibrate the imaging system. The phantom studies were performed with uniform background phantom and non-uniform background phantom. The breast lesion phantoms (2 cm in diameter and 0.5 cm in thickness) were made with water densities ranging from 0 to 100%. The lesion phantoms were placed in different positions and depths on the phantoms to investigate the accuracy of the measurement under various conditions. The plastic water content of the lesion was measured by subtracting the total decomposed plastic water signal from a surrounding 2.5 mm thick border outside the lesion. In addition, bovine tissue samples composed of 80 % lean were imaged as background for the simulated lesion phantoms. Results: The thickness of measured and known water contents was compared. The rootmean-square (RMS) errors in water thickness measurements were 0.01 cm for the uniform background phantom, 0.04 cm for non-uniform background phantom, and 0.03 cm for 80% lean bovine tissue background. Conclusion: The results indicate that the proposed technique using spectral mammography can be used to accurately characterize breast lesion compositions.

60 APPLIED LIFE SCIENCES↗

GrainNN: A neighbor-aware long short-term memory network for predicting microstructure evolution during polycrystalline grain formation

High fidelity simulations of grain formation in alloys are an indispensable tool for process-to-mechanical-properties characterization. Such simulations, however, can be computationally expensive as they require fine spatial and temporal discretizations. Their cost becomes an obstacle to parametric studies and ensemble runs and ultimately makes downstream tasks like optimal control and uncertainty quantification challenging. To enable such downstream tasks, we introduce GrainNN, an efficient and accurate reduced-order model for epitaxial grain growth in additive manufacturing conditions. GrainNN is a sequence-to-sequence long-short-term-memory (LSTM) deep neural network that evolves the dynamics of manually crafted features. Its innovations are (1) an attention mechanism with grain-microstructure-specific transformer architecture; and (2) an overlapping combination of several clones of the network to generalize to grain configurations that are different from those used for training. This design enables GrainNN to predict grain formation for unseen physical parameters, grain number, domain size and geometry. Furthermore, GrainNN not only reconstructs the quantities of interest but also can be pointwise accurate. In our numerical experiments, we use a polycrystalline phase field method to both generate the training data and assess GrainNN. For multiparametric, ensemble simulations with many grains, GrainNN can be orders of magnitude faster than phase field simulations, while delivering 5%–15% pointwise error. Additionally, this speedup includes the cost of the phase field simulations for generating training data.

36 MATERIALS SCIENCE↗

Resilient Observer Design for Cyber-Physical Systems with Data-Driven Measurement Pruning

Resilient observer design for Cyber-Physical Systems (CPS) in the presence of adversarial false data injection attacks (FDIA) is an active area of research. The existing state-of-the-art algorithms tend to break down as more and more knowledge of the system is built into the attack model; also as the percentage of attacked nodes increases. From the view of optimization theory, the problem is often cast as a classical error correction problem for which a theoretical limit of has been established as the maximum percentage attacked nodes for which state recovery is guaranteed. Beyond this limit, the performance of -minimization based schemes, for instance, deteriorates rapidly. Similar performance degradation occurs for other types of resilient observers beyond certain percentages of attacked nodes. In order to increase the corresponding percentage of attacked nodes for which state recoveries can be guaranteed, researchers have begun to incorporate prior information into the underlying resilient observer design framework. For the most pragmatic cases, this prior information is often obtained through a data-driven machine learning process. Existing results have shown a strong positive correlation between the maximum attacked percentages that can be tolerated and the accuracy of the data-driven model. Motivated by these results, this chapter examines the case for pruning algorithms designed to improve the Positive Prediction Value (PPV) of the resulting prior information, given stochastic uncertainty characteristics of the underlying machine learning model. Theoretical quantification of the achievable improvement is given. Simulation results show that the pruning algorithm significantly increases the maximum correctable percentage of attacked nodes, even for machine learning model whose prediction power is comparable to the random flip of a coin.

Resilient Observer, Cyber-physical Systems, Data-D↗

Data Assimilation for Robust UQ Within Agent-Based Simulation on HPC Systems

Agent-based simulation provides a powerful tool for in silico system modeling. However, these simulations do not provide built-in methods for uncertainty quantification (UQ). Within these types of models a typical approach to UQ is to run multiple realizations of the model then compute aggregate statistics. This approach is limited due to the compute time required for a solution. When faced with an emerging biothreat, public health decisions need to be made quickly and solutions for integrating near real-time data with analytic tools are needed. We propose an integrated Bayesian UQ framework for agent-based models based on sequential Monte Carlo sampling. Given streaming or static data about the evolution of an emerging pathogen this Bayesian framework provides a distribution over the parameters governing the spread of a disease through a population. These estimates of the spread of a disease may be provided to public health agencies seeking to abate the spread. By coupling agent-based simulations with Bayesian modeling in a data assimilation, our proposed framework provides a powerful tool for modeling dynamical systems in silico. We propose a method which reduces model error and provides a range of realistic possible outcomes. Moreover, our method addresses two primary limitations of ABMs: the lack of UQ and an inability to assimilate data. Our proposed framework combines the flexibility of an agent-based model with UQ provided by the Bayesian paradigm in a workflow which scales well to HPC systems. We provide algorithmic details and results on a simulated outbreak with both static and streaming data.

Spannaus, Adam [ORNL] (ORCID:0000000225213657)↗

Extended Forward Sensitivity Analysis for Uncertainty Quantification

This report presents the forward sensitivity analysis method as a means for quantification of uncertainty in system analysis. The traditional approach to uncertainty quantification is based on a “black box” approach. The simulation tool is treated as an unknown signal generator, a distribution of inputs according to assumed probability density functions is sent in and the distribution of the outputs is measured and correlated back to the original input distribution. This approach requires large number of simulation runs and therefore has high computational cost. Contrary to the “black box” method, a more efficient sensitivity approach can take advantage of intimate knowledge of the simulation code. In this approach equations for the propagation of uncertainty are constructed and the sensitivity is solved for as variables in the same simulation. This “glass box” method can generate similar sensitivity information as the above “black box” approach with couples of runs to cover a large uncertainty region. Because only small numbers of runs are required, those runs can be done with a high accuracy in space and time ensuring that the uncertainty of the physical model is being measured and not simply the numerical error caused by the coarse discretization. In the forward sensitivity method, the model is differentiated with respect to each parameter to yield an additional system of the same size as the original one, the result of which is the solution sensitivity. The sensitivity of any output variable can then be directly obtained from these sensitivities by applying the chain rule of differentiation. We extend the forward sensitivity method to include time and spatial steps as special parameters so that the numerical errors can be quantified against other physical parameters. This extension makes the forward sensitivity method a much more powerful tool to help uncertainty analysis. By knowing the relative sensitivity of time and space steps with other interested physical parameters, the simulation can be run at appropriate time and space steps that ensure numerical sensitivities will not affect the confidence of the physical parameter sensitivity results. Two well defined benchmark problems, thermal wave and nonlinear diffusion, are utilized to demonstrate the extended forward sensitivity analysis method. All the physical solutions, parameter sensitivity solutions, even time step sensitivity in one case, have analytical forms, which allows the verification to be done in the strictest sense. A pilot code, Extended Forward sensitivity Analysis pilot code (EFA), has been developed to implement the above work.

97 MATHEMATICS AND COMPUTING↗

Quantification and assessment of the atmospheric boundary layer height measured during the AWAKEN experiment by a scanning LiDAR

The atmospheric boundary layer (ABL) height plays a key role in many atmospheric processes as one of the dominant flow length scales. However, a systematic quantification of the ABL height over the entire range of scales (i.e., with periods ranging from one minute to one year) is still lacking in literature. In this work, the ABL height is quantified based on high-resolution measurements collected by a scanning pulsed Doppler LiDAR during the recent American WAKE experimeNt (AWAKEN) campaign. The high availability of ABL height estimates (≈2200 collected over one year and each of them based on 10-min averaged statistics) allows to robustly assess five different ABL height models, i.e., one for convective thermal conditions and four for stable conditions. Thermal condition is quantified by a stability parameter spanning three orders of magnitude and probed by near-ground 3D sonic anemometry. The free-atmosphere stability, quantified by the Brunt–Väisälä frequency, is both calculated from simultaneous radiosonde measurements and obtained from the best fit of two of the chosen ABL height models. Good agreement is found between the data and three of the chosen models, quantified by mean absolute errors on the ABL height between 281 and 585 m. Furthermore, the seasonal variability of the convective ABL height model parameters (−15% to +23% with respect to the year baseline) agrees with the variability of buoyancy-generated turbulence caused by the variation in solar radiation throughout the year.

17 WIND ENERGY↗

Stochastic finite difference lattice Boltzmann method for steady incompressible viscous flows

With the advent of state-of-the-art computers and their rapid availability, the time is ripe for the development of efficient uncertainty quantification (UQ) methods to reduce the complexity of numerical models used to simulate complicated systems with incomplete knowledge and data. The spectral stochastic finite element method (SSFEM) which is one of the widely used UQ methods, regards uncertainty as generating a new dimension and the solution as dependent on this dimension. A convergent expansion along the new dimension is then sought in terms of the polynomial chaos system, and the coefficients in this representation are determined through a Galerkin approach. This approach provides an accurate representation even when only a small number of terms are used in the spectral expansion; consequently, saving in computational resource can be realized compared to the Monte Carlo (MC) scheme. Recent development of a finite difference lattice Boltzmann method (FDLBM) that provides a convenient algorithm for setting the boundary condition allows the flow of Newtonian and non-Newtonian fluids, with and without external body forces to be simulated with ease. Also, the inherent compressibility effect in the conventional lattice Boltzmann method, which might produce significant errors in some incompressible flow simulations, is eliminated. As such, the FDLBM together with an efficient UQ method can be used to treat incompressible flows with built in uncertainty, such as blood flow in stenosed arteries. The objective of this paper is to develop a stochastic numerical solver for steady incompressible viscous flows by combining the FDLBM with a SSFEM. Validation against MC solutions of channel/Couette, driven cavity, and sudden expansion flows are carried out.

97 MATHEMATICS AND COMPUTING↗

Goal-oriented a-posteriori estimation of model error as an aid to parameter estimation

In this work, a Bayesian model calibration framework is presented that utilizes goal-oriented a-posterior error estimates in quantities of interest (QoIs) for classes of high-fidelity models characterized by PDEs. It is shown that for a large class of computational models, it is possible to develop a computationally inexpensive procedure for calibrating parameters of high-fidelity models of physical events when the parameters of low-fidelity (surrogate) models are known with acceptable accuracy. The main ingredients in the proposed model calibration scheme are goal-oriented a-posteriori estimates of error in QoIs computed using a so-called lower fidelity model compared to those of an uncalibrated higher fidelity model. The estimates of error in QoIs are used to define likelihood functions in Bayesian inversion analysis. A standard Bayesian approach is employed to compute the posterior distribution of model parameters of high-fidelity models. As applications, parameters in a quasi-linear second-order elliptic boundary-value problem (BVP) are calibrated using a second-order linear elliptic BVP. In a second application, parameters of a tumor growth model involving nonlinear time-dependent PDEs are calibrated using a lower fidelity linear tumor growth model with known parameter values.

A-posterior estimates↗

SU-C-17A-05: Quantification of Intra-Fraction Motion of Breast Tumors Using Cine-MRI

Purpose: Magnetic resonance imaging (MRI) enables direct characterization of intra-fraction motion ofbreast tumors, due to high softtissue contrast and geometric accuracy. The purpose is to analyzethis motion in early-stage breast-cancer patients using pre-operative supine cine-MRI. Methods: MRI was performed in 12 female early-stage breast-cancer patients on a 1.5-T Ingenia (Philips)wide-bore scanner in supine radiotherapy (RT) position, prior to breast-conserving surgery. Twotwodimensional (2D) T2-weighted balanced fast-field echo (cine-MRI) sequences were added tothe RT protocol, oriented through the tumor. They were alternately acquired in the transverse andsagittal planes, every 0.3 s during 1 min. A radiation oncologist delineated gross target volumes(GTVs) on 3D contrast-enhanced MRI. Clinical target volumes (CTV = GTV + 15 mm isotropic)were generated and transferred onto the fifth time-slice of the time-series, to which subsequents lices were registered using a non-rigid Bspline algorithm; delineations were transformed accordingly. To evaluate intra-fraction CTV motion, deformation fields between the transformed delineations were derived to acquire the distance ensuring 95% surface coverage during scanning(P95%), for all in-plane directions: anteriorposterior (AP), left-right (LR), and caudal-cranial(CC). Information on LR was derived from transverse scans, CC from sagittal scans, AP fromboth sets. Results: Time-series with registration errors - induced by motion artifacts - were excluded by visual inspection. For our analysis, 11 transverse, and 8 sagittal time-series were taken into account. Themedian P95% calculated in AP (19 series), CC (8), and LR (11) was 1.8 mm (range: 0.9–4.8), 1.7mm (0.8–3.6), and 1.0 mm (0.6–3.5), respectively. Conclusion: Intra-fraction motion analysis of breast tumors was achieved using cine-MRI. These first results show that in supine RT position, motion amplitudes are limited. This information can be used for adaptive RT planning, and to develop preoperative partial-breast RT strategies, such asablative RT for early-stage breast-cancer patients.

60 APPLIED LIFE SCIENCES↗