Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Phase Transition Enthalpy Measurements of Organic and Organometallic Compounds. Sublimation, Vaporization and Fusion Enthalpies From 1880 to 2015. Part 1. C{sub 1} − C{sub 10}

A compendium of phase change enthalpies published in 2010 is updated to include the period 1880–2015. Phase change enthalpies including fusion, vaporization, and sublimation enthalpies are included for organic, organometallic, and a few inorganic compounds. Part 1 of this compendium includes organic compounds from C{sub 1} to C{sub 10}. Part 2 of this compendium, to be published separately, will include organic and organometallic compounds from C{sub 11} to C{sub 192}. Sufficient data are presently available to permit thermodynamic cycles to be constructed as an independent means of evaluating the reliability of the data. Temperature adjustments of phase change enthalpies from the temperature of measurement to the standard reference temperature, T = 298.15 K, and a protocol for doing so are briefly discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development of methods for primary mast cells in vitro and ex vivo: An historical review

Highlights: • Mast cells form a first-line defense of immune system against various challenges. • Over the past few decades, technologies for acquiring mast cells have been continually optimized. • The advantages and applicability of diverse mast cell models evaluated. • It is important to choose a proper cell source for mast cell-related experiments. Mast cells (MCs) are tissue-based stationary effector cells that form the immune system's first-line defense against various challenges. They are developed from the bone marrow-derived progenitors to complete their differentiation and maturation in the tissues where they eventually establish residence. MCs have been implicated in many diseases, such as allergy, parasitic infection, and neoplastic disorders. Immortalized MC lines, such as RBL-2H3, HMC-1, and LAD-2, are useful for investigating the biological functions of MC only to some extents due to the restriction of degranulation evaluation, in vivo injection and other factors. Over the past few decades, technologies for acquiring primarily MCs have been continually optimized, and novel protocols have been proposed. However, no relevant publications have analyzed and summarized these techniques. In this review, the classical approaches for extracting MCs are generalized, and new methods with potential values are introduced. We also evaluate the advantages and applicability of diverse MC models. Since MCs exhibit substantial plasticity and functional diversity due to different origins, it is both necessary and urgent to select a reliable and suitable source of MCs for a particular study.

60 APPLIED LIFE SCIENCES↗

PET optimization for improved assessment and accurate quantification of {sup 90}Y-microsphere biodistribution after radioembolization

Purpose: {sup 90}Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging {sup 90}Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for {sup 90}Y imaging and to optimize the PET protocol to improve the assessment and the quantification of {sup 90}Y-microsphere biodistribution after radioembolization. Methods: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a{sup 90}Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with {sup 90}Y. To evaluate the count rate performance, {sup 90}Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml {sup 90}Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres{sup ®}. The developed methodology was applied to ten patients after SIR-Spheres{sup ®} treatment acquiring a 10 min per bed PET. Results: The energy spectrum showed the{sup 90}Y bremsstrahlung radiation. The {sup 90}Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. {sup 90}Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the {sup 90}Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in {sup 90}Y PET acquisition, the optimal parameters for the standard OSEM+PSF reconstruction were only one iteration and a postreconstruction filter of 6 mm FWHM, for both TOF and non-TOF reconstructions. Moreover, when TOF is included, the signal to noise ratio increased and visibility achieved 100% by the experienced observers and 93.3% according to the Rose model of statistical detection. In 50% of patients, TOF allowed the visualization of {sup 90}Y radioembolized lesions not seen without TOF, confirming phantom results. Liver activity was accurately quantified, with no significant differences between reconstructed and actual delivered activity to the whole-liver [mean relative difference (10.2 ± 14.7)%]. Conclusions: Qualitative and quantitative{sup 90}Y PET imaging improved with the introduction of TOF in a PET/CT scanner, thereby allowing the visualization of microsphere deposition in lesions not visible in non-TOF images. This technique accurately quantifies the total activity delivered to the liver during radioembolization with {sup 90}Y-microspheres and allows dose estimation.

60 APPLIED LIFE SCIENCES↗

Weighted active space protocol for multireference machine-learned potentials

Multireference methods such as multiconfiguration pair-density functional theory accurately capture electronic correlation in systems with strong multiconfigurational character, but their cost precludes direct use in molecular dynamics. Combining these methods with machine-learned interatomic potentials (MLPs) can extend their reach. However, the sensitivity of multireference calculations to the choice of the active space complicates the consistent evaluation of energies and gradients across structurally diverse nuclear configurations. To overcome this limitation, we introduce the weighted active space protocol (WASP), a systematic approach to assign a consistent active space for a given system across uncorrelated configurations. By integrating WASP with MLPs and enhanced sampling techniques, we propose a data-efficient active learning cycle that enables the training of an MLP on multireference data. We demonstrated the approach on the TiC + -catalyzed C–H activation of methane, a reaction that poses challenges for Kohn–Sham density functional theory due to its significant multireference character. This framework enables accurate and efficient modeling of catalytic dynamics, establishing a paradigm for simulating complex reactive processes beyond the limits of conventional electronic-structure methods.

enhanced sampling↗

Application of the ESMACS Binding Free Energy Protocol to a Multi-Binding Site Lactate Dehydogenase A Ligand Dataset

Over the past two decades, the use of fragment-based lead generation has become a common, mature approach to identify tractable starting points in chemical space for the drug discovery process. This approach naturally involves the study of the binding properties of highly heterogeneous ligands. Such datasets challenge computational techniques to provide comparable binding free energy estimates from different binding modes. The performance of a range of statistically robust ensemble-based binding free energy calculation protocols, called ESMACS (enhanced sampling of molecular dynamics with approximation of continuum solvent), is evaluated. Ligands designed to target two binding pockets in the lactate dehydogenase, a target protein, which vary in size, charge, and binding mode, are studied. When compared to experimental results, excellent statistical rankings are obtained across this highly diverse set of ligands. In addition, three approaches to account for entropic contributions are investigated: 1) normal mode analysis, 2) weighted solvent accessible surface area (WSAS), and 3) variational entropy. Normal mode analysis and WSAS correlate strongly with each other—although the latter is computationally far cheaper—but do not improve rankings. Variational entropy corrects exaggerated discrimination of ligands bound in different pockets but creates three outliers which reduce the quality of the overall ranking.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial approaches in benchmarking and round robin testing for proton exchange membrane water electrolyzers

As ever increasing amounts of renewable electricity enter the energy supply mix on a regional, national and international basis, greater emphasis is being placed on energy conversion and storage technologies to deal with the oscillations, excess and lack of electricity. Hydrogen generation via proton exchange membrane water electrolysis (PEMWE) is one technology that offers a pathway to store large amounts of electricity in the form of hydrogen. The challenges to widespread adoption of PEMWE lie in their high capital and operating costs which both need to be reduced through R&D. An evaluation of reported performance data in literature for PEMWE reveals that there are excessive variations of in situ performance results that make it difficult to draw conclusions on the pathway forward to performance optimization and future R&D directions. In order to enable the meaningful comparison of in-situ performance evaluation across laboratories there is an obvious need for standardization of materials and testing protocols. Herein, we address this need by reporting the results of a round robin test effort conducted at the laboratories of five contributors to the IEA electrolysis annex 30. The effort utilized common sets of test articles, materials, test cells, and employed a set of shared test protocols. The maximum observed deviation between laboratories at 1 A cm-2 at cell temperatures of 60 and 80 degrees C, was 27 and 20 mV, respectively. The deviation of the results from laboratory to laboratory was a factor of 2-3 higher than the lowest deviation observed at one single lab and test station. However, the highest deviations observed were 1/10th of those extracted by a literature survey on similar material sets. The biggest takeaways are that cell temperature control appears to be the most significant source of deviation between results, while care must be taken with respect to break in conditions and cell electrical connections for meaningful performance data.

08 HYDROGEN↗

Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm{sup 3}, mean 19.65 cm{sup 3}. In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm{sup 3}, mean 1.59 cm{sup 3}. There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and fractionation approach to standard 6-week radiation therapy with a sequential boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly Efficient Training, Refinement, and Validation of a Knowledge-based Planning Quality-Control System for Radiation Therapy Clinical Trials

Purpose: To demonstrate an efficient method for training and validation of a knowledge-based planning (KBP) system as a radiation therapy clinical trial plan quality-control system. Methods and Materials: We analyzed 86 patients with stage IB through IVA cervical cancer treated with intensity modulated radiation therapy at 2 institutions according to the standards of the INTERTECC (International Evaluation of Radiotherapy Technology Effectiveness in Cervical Cancer, National Clinical Trials Network identifier: 01554397) protocol. The protocol used a planning target volume and 2 primary organs at risk: pelvic bone marrow (PBM) and bowel. Secondary organs at risk were rectum and bladder. Initial unfiltered dose-volume histogram (DVH) estimation models were trained using all 86 plans. Refined training sets were created by removing sub-optimal plans from the unfiltered sample, and DVH estimation models… and DVH estimation models were constructed by identifying 30 of 86 plans emphasizing PBM sparing (comparing protocol-specified dosimetric cutpoints V{sub 10} (percentage volume of PBM receiving at least 10 Gy dose) and V{sub 20} (percentage volume of PBM receiving at least 20 Gy dose) with unfiltered predictions) and another 30 of 86 plans emphasizing bowel sparing (comparing V{sub 40} (absolute volume of bowel receiving at least 40 Gy dose) and V{sub 45} (absolute volume of bowel receiving at least 45 Gy dose), 9 in common with the PBM set). To obtain deliverable KBP plans, refined models must inform patient-specific optimization objectives and/or priorities (an auto-planning “routine”). Four candidate routines emphasizing different tradeoffs were composed, and a script was developed to automatically re-plan multiple patients with each routine. After selection of the routine that best met protocol objectives in the 51-patient training sample (KBP{sub FINAL}), protocol-specific DVH metrics and normal tissue complication probability were compared for original versus KBP{sub FINAL} plans across the 35-patient validation set. Paired t tests were used to test differences between planning sets. Results: KBP{sub FINAL} plans outperformed manual planning across the validation set in all protocol-specific DVH cutpoints. The mean normal tissue complication probability for gastrointestinal toxicity was lower for KBP{sub FINAL} versus validation-set plans (48.7% vs 53.8%, P<.001). Similarly, the estimated mean white blood cell count nadir was higher (2.77 vs 2.49 k/mL, P<.001) with KBP{sub FINAL} plans, indicating lowered probability of hematologic toxicity. Conclusions: This work demonstrates that a KBP system can be efficiently trained and refined for use in radiation therapy clinical trials with minimal effort. This patient-specific plan quality control resulted in improvements on protocol-specific dosimetric endpoints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast charge implications: Pack and cell analysis and comparison

This study investigates the effect of 50-kW (about 2C) direct current fast charging on a full-size battery electric vehicle's battery pack in comparison to a pack exclusively charged at 3.3 kW, which is the common alternating current Level 2 charging power level. Comparable scaled charging protocols are also independently applied to individual cells at three different temperatures, 20 °C, 30 °C, and 40 °C, to perform a comparative analysis with the packs. Dominant cell-level aging modes were identified through incremental capacity analysis and compared with full packs to gain a clear understanding of additional key factors that affect pack aging. While the cell-level study showed a minor impact on performance due to direct current fast charging, the packs showed a significantly higher rate of capacity fade under similar charging protocols. This indicates that pack-level aging cannot be directly extrapolated from cell evaluation. With this being said, delayed fast charging, completing shortly before discharge, was found to have less of an impact on battery degradation than conventional alternating current Level 2 charging

25 ENERGY STORAGE↗

High-Performance Semiempirical Excited-State Molecular Dynamics Powered by Graphics Processing Units

Here, this Letter introduces excited-state molecular dynamics in PYSEQM, a GPU-accelerated semiempirical quantum chemistry engine implemented in PyTorch. The new module enables Born–Oppenheimer molecular dynamics (BOMD) using configuration-interaction singles and random phase approximation for excited states, allowing long trajectories and large statistical ensembles to be simulated efficiently on a single GPU. We also implement an extended Lagrangian excited-state BOMD (XL-ESMD) scheme that propagates auxiliary electronic variables, enabling relaxed ground and excited-state convergence thresholds without compromising energy conservation. The excited-state BOMD implementation scales smoothly from small chromophores to a nearly 900-atom dendrimer (taking 6.5 s per MD step). PYSEQM also supports batched execution, allowing many geometries or trajectories to be evaluated in a single GPU launch, substantially increasing throughput and making ensemble-based protocols routine. As a demonstration, we compute absorption, emission, and infrared spectra from trajectories propagated on the ground and first excited states. The XL-ESMD scheme yields identical spectra at significantly lower computational cost, establishing the role of extended Lagrangian based dynamics for efficient excited-state BOMD simulations. Beyond raw performance, PYSEQM’s PyTorch foundation provides automatic differentiation for forces, efficient GPU batching, and seamless interfacing with machine learning models. These capabilities position PYSEQM as a practical platform for machine learning-augmented excited-state dynamics and lay the foundation for future data-driven nonadiabatic excited-state dynamics modeling of ultrafast spectroscopic probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-Chain Lipids Facilitate Insertion of Large Nanoparticles into Membranes of Small Unilamellar Vesicles

Insertion of hydrophobic nanoparticles into phospholipid bilayers is limited to small particles that can incorporate into a hydrophobic membrane core between two lipid leaflets. Incorporation of nanoparticles above this size limit requires the development of challenging surface engineering methodologies. In principle, increasing the long-chain lipid component in the lipid mixture should facilitate incorporation of larger nanoparticles. Here, we explore the effect of incorporating very long phospholipids (C24:1) into small unilamellar vesicles on the membrane insertion efficiency of hydrophobic nanoparticles that are 5–11 nm in diameter. To this end, we improve an existing vesicle preparation protocol and utilized cryogenic electron microscopy imaging to examine the mode of interaction and evaluate the insertion efficiency of membrane-inserted nanoparticles. We also perform classical coarse-grained molecular dynamics simulations to identify changes in lipid membrane structural properties that may increase insertion efficiency. Furthermore, our results indicate that long-chain lipids increase the insertion efficiency by preferentially accumulating near membrane-inserted nanoparticles to reduce the thermodynamically unfavorable disruption of the membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-I-82: Improving CT Image Quality for Radiation Therapy Using Iterative Reconstruction Algorithms and Slightly Increasing Imaging Doses

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition AS Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-289: Dose-Volume-Effect Relationships for Lung Cancer Patients Treated with SBRT On a Prospective Protocol

Purpose: Stereotactic body radiotherapy (SBRT) is commonly used to treat early stage lung tumors. This study was designed to evaluate associations between dose, volume and clinical outcomes including analysis of both clinical toxicity scores and quality of life (QOL) data for non-small cell lung cancer patients treated with SBRT. Preliminary results are presented. Methods: Sixty-seven NSCLC patients, 46 primarily with early stage, and 21 with recurrent disease were treated with dose regimens consisting mainly of 12 Gy x 4 fractions, and 3 or 5 fractions at lower dose, for patients with recurrent disease (Table 1). Follow-up data is being collected at baseline, after treatment and at 3, 6, 12, 18 and 24 months post-treatment. Clinical follow-up data acquired to date was assessed using the Charlson Comorbidity Clinical and Toxicity Scoring forms. QOL data was evaluated using the EQ-5D, and FACT-TOI validated surveys. All outcomes surveys are collected within an “in-house” developed outcomes database. Results: The median follow-up was 3.5±0.8 months. Mean lung doses (MLD) were converted to BED-2 Gy using the linear-quadratic model with an alpha/beta=3.0. Average MLD was 3.7+3.1 Gy (range: 0.4–20.9 Gy). The percentages of patients with > grade 2 cough, dyspnea and fatigue were 13.3, 17.0, 6.3%, respectively. Preliminary analyses (at 3 months after SBRT) show a mild correlation between MLD > 2 Gy and > grade 2 cough (borderline significant) and dyspnea (significant, p<0.05). One patient was observed with a grade 3 cough. Given the short follow-up, tumor control is not yet assessable. Conclusion: The SBRT dose fractionation regimen of 12 Gy x 4 was well tolerated at early time points. Additional follow-up is required to assess the long-term clinical outcome efficacy and toxicity profiles of the dose regimen.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-10: Evaluation of a Novel Dedicated Breast PET System (Mammi-PET)

Purpose: To evaluate the performance characteristics of a novel dedicated breast PET system (Mammi-PET, Oncovision). The system has 2 detector rings giving axial/transaxial field of view of 8/17 cm. Each ring consists of 12 monolithic LYSO modules coupled to PSPMTs. Methods: Uniformity, sensitivity, energy and spatial resolution were measured according to NEMA standards. Count rate performance was investigated using a source of F-18 (1384uCi) decayed over 5 half-lives. A prototype PET phantom was imaged for 20 min to evaluate image quality, recovery coefficients and partial volume effects. Under an IRB-approved protocol, 11 patients who just underwent whole body PET/CT exams were imaged prone with the breast pendulant at 5–10 minutes/breast. Image quality was assessed with and without scatter/attenuation correction and using different reconstruction algorithms. Results: Integral/differential uniformity were 9.8%/6.0% respectively. System sensitivity was 2.3% on axis, 2.2% and 2.8% at 3.8 cm and 7.8 cm off-axis. Mean energy resolution of all modules was 23.3%. Spatial resolution (FWHM) was 1.82 mm and 2.90 mm on axis and 5.8 cm off axis. Three cylinders (14 mm diameter) in the PET phantom were filled with activity concentration ratios of 4:1, 3:1, and 2:1 relative to the background. Measured cylinder to background ratios were 2.6, 1.8 and 1.5 (without corrections) and 3.6, 2.3 and 1.5 (with attenuation/scatter correction). Five cylinders (14, 10, 6, 4 and 2 mm diameter) each with an activity ratio of 4:1 were measured and showed recovery coefficients of 1, 0.66, 0.45, 0.18 and 0.18 (without corrections), and 1, 0.53, 0.30, 0.13 and 0 (with attenuation/scatter correction). Optimal phantom image quality was obtained with 3D MLEM algorithm, >20 iterations and without attenuation/scatter correction. Conclusion: The MAMMI system demonstrated good performance characteristics. Further work is needed to determine the optimal reconstruction parameters for qualitative and quantitative applications.

60 APPLIED LIFE SCIENCES↗

Performance of three-dimensional printed nasopharyngeal swabs for COVID-19 testing

At the start of the COVID-19 pandemic, the US faced nationwide shortages of nasopharyngeal swabs due to both overwhelmed supply chains and an increase in demand. To address this shortfall, multiple 3D printed swabs were ultimately produced and sold for COVID-19 testing. In this work, we present a framework for mechanical and functional bench-testing of nasopharyngeal swabs using standard and widely available material testing equipment. Using this framework, we offer a comprehensive, quantitative comparison of the 3D printed swabs to benchmark their performance against traditional flocked swabs. The test protocols were designed to emulate the clinical use of the nasopharyngeal swabs and to evaluate potential failure modes. Overall, the 3D printed swabs performed comparably to, or outperformed, the traditional swabs in all mechanical tests. While traditional swabs outperformed some of the new 3D printed swabs in terms of sample uptake and retention, similar amounts of RNA were recovered from both 3D printed and traditional swabs.

3D printing↗

Hawaii-Okinawa Building Evaluations

NREL conducted energy evaluations at the Itoman City Hall building in Itoman, Okinawa Prefecture, Japan, and the Hawaii State Capitol building in Honolulu, Hawaii. This report summarizes the findings from the evaluations, including the best practices identified at each site and opportunities for improving energy efficiency and renewable energy. The findings from this evaluation are intended to inform energy efficient building design, energy efficiency technology, and management protocols for buildings in subtropical climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Expansion in ETF Grout Compositional Variants

In summary, the Base Case grout, Mix K, prepared according to the protocol provided (short stirring time after struvite precipitation of about 30 minutes) expanded when cured in a dry and damp sealed bag. Two variants, Mix M, 100 % slag in the dry mix, did not expand when prepared and cured under the same dry and damp conditions. Mix L, precipitated struvite removed, showed very slight expansion after curing 289 days for both dry and damp curing which was expressed as slight bulging at the bottom of the container. Mix N, 100 % dilution of the simulant, did not expand when cured under dry conditions or in a sealed container in damp conditions. However, a cylinder of Mix N cured in a container that was slit and taped back together did expand in damp conditions. This condition enabled the grout to be exposed to more moisture that the grout sample cured in the capped container and stored in the same zip top bag with the damp towel. This information is provided to support processing and containerization of the ETF ammonia grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗