Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Investigation of 2D photonic crystal structure based channel drop filter using quad shaped photonic crystal ring resonator for CWDM system

In this paper, the design & performance of two dimensional (2-D) photonic crystal structure based channel drop filter is investigated using quad shaped photonic crystal ring resonator. In this paper, Photonic Crystal (PhC) based on square lattice periodic arrays of Gallium Indium Phosphide (GaInP) rods in air structure have been investigated using Finite Difference Time Domain (FDTD) method and photonic band gap is being calculated using Plane Wave Expansion (PWE) method. The PhC designs have been optimized for telecommunication wavelength λ= 1571 nm by varying the rods lattice constant. The number of rods in Z and X directions is 21 and 20, with lattice constant 0.540 nm it illustrates that the arrangement of Gallium Indium Phosphide (GaInP) rods in the structure which gives the overall size of the device around 11.4 µm × 10.8 µm. The designed filter gives good dropping efficiency using 3.298, refractive index. The designed structure is useful for CWDM systems. This device may serve as a key component in photonic integrated circuits. The device is ultra compact with the overall size around 123 µm{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IOTA : integration optimization, triage and analysis tool for the processing of XFEL diffraction images

Serial femtosecond crystallography (SFX) uses an X-ray free-electron laser to extract diffraction data from crystals not amenable to conventional X-ray light sources owing to their small size or radiation sensitivity. However, a limitation of SFX is the high variability of the diffraction images that are obtained. As a result, it is often difficult to determine optimal indexing and integration parameters for the individual diffraction images. Presented here is a software package, called IOTA , which uses a grid-search technique to determine optimal spot-finding parameters that can in turn affect the success of indexing and the quality of integration on an image-by-image basis. Integration results can be filtered using a priori information about the Bravais lattice and unit-cell dimensions and analyzed for unit-cell isomorphism, facilitating an improvement in subsequent data-processing steps.

Chemistry↗

Calibration of coronary calcium scores determined using iterative image reconstruction (AIDR 3D) at 120, 100, and 80 kVp

Purpose: Computed tomography (CT) radiation dose reduction is frequently achieved by applying lower tube voltages and using iterative reconstruction (IR). For calcium scoring, the reference protocol at 120 kVp with filtered back projection (FBP) is still used, because kVp and IR may influence the Agatston score (AS) and volume score (VS). The authors present a two-step method to optimize dose: first, to determine the lowest feasible exposure and highest noise thresholds; second, to define a calibration method that ensures that the AS and VS are similar to the reference protocol. Methods: AS and VS were measured for an anthropomorphic thoracic phantom that includes a calcium calibration module. The phantom was scanned on a 320-row CT scanner, at tube voltages of 120 kVp using FBP, and 120, 100, and 80 kVp using adaptive iterative dose reduction (AIDR 3D) reconstruction. The minimum CTDIs were determined based on three objective quality criteria. Calibration was performed to estimate adjusted CT number thresholds for the lower kVp acquisitions. Finally, the accuracies of the total and individual insert scores at dose level close to the minimum CTDI level were investigated and compared to low (FBP{sub LD} − 120) and high (FBP{sub HD} − 120) dose reference protocols (based on ten repeated acquisitions for each group). Results: IR allows the exposure to be reduced by 69% at 120 kVp, with no significant effect on the total scores when averaged over all included dose steps and compared to FBP-120 (AS: 693 vs 699, p = 0.182; VS: 588 vs 587 mm{sup 3}, p = 0.569). Also when averaged over ten repeated scans and compared to FBP{sub HD} − 120 (AS: 709 vs 704, p = 0.435; VS: 604 vs 601 mm{sup 3}, p = 0.479), there is no statistical significant effect. Reducing the peak tube voltage allows even greater dose reductions: 73% at 100 kVp and 76% at 80 kVp. The calibrated CT number thresholds for analysis at 120, 100, and 80 kVp were, respectively, 130, 133, and 160 HU for the Agatston score, and 130, 132, and 140 HU for the volume score. Following the calibration, the mean scores of the four groups with dose variation were not significantly different from the reference protocol, at 100 kVp (AS: 698 vs 699, p = 0.818; VS: 584 vs 587 mm{sup 3}, p = 0.365) or at 80 kVp (AS: 698 vs 699, p = 0.996; VS: 586 vs 587 mm{sup 3}, p = 0.827). Similarly, there was no significant score difference with FBP{sub LD} − 120 during repeated scanning: 100 kVp (AS: 690 vs 694, p = 0.394; VS: 579 vs 585 mm{sup 3}, p = 0.168) and 80 kVp (AS: 703 vs 694, p = 0.115; VS: 588 vs 585 mm{sup 3}, p = 0.613). Compared to FBP{sub HD} − 120 group, the relative score deviation for the accuracy of the 400 and 800 mg/cm{sup 3} HA inserts with 3 and 5 mm diameter is less than 7%. However, the relative deviation of the smaller 1 mm inserts is poorer (up to 41% deviations for scores <3). Conclusions: With iterative reconstruction using AIDR 3D, deviations of the total Agatston and volume scores remain within 4% of the reference protocol. The 1 mm inserts were detected as calcification, but scores less than ten tend to be underestimated. Following the calibration process, the application of IR in combination with reduced tube voltages allows up to 76% lower radiation dose.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-07: High-Resolution, High-Sensitivity Imaging and Quantification of Intratumoral Distributions of Gold Nanoparticles Using a Benchtop L-Shell XRF Imaging System

Purpose: To demonstrate the ability to perform high-resolution imaging and quantification of sparse distributions of gold nanoparticles (GNPs) within ex vivo tumor samples using a highly-sensitive benchtop L-shell x-ray fluorescence (XRF) imaging system. Methods: An optimized L-shell XRF imaging system was assembled using a tungsten-target x-ray source (operated at 62 kVp and 45 mA). The x-rays were filtered (copper: 0.08 mm & aluminum: 0.04 mm) and collimated (lead: 5 cm thickness, 3 cm aperture diameter) into a cone-beam in order to irradiate small samples or objects. A collimated (stainless steel: 4 cm thickness, 2 mm aperture diameter) silicon drift detector, capable of 2D translation, was placed at 90° with respect to the beam to acquire XRF/scatter spectra from regions of interest. Spectral processing involved extracting XRF signal from background, followed by attenuation correction using a Compton scatter-based normalization algorithm. Calibration phantoms with water/GNPs (0 and 0.00001–10 mg/cm{sup 3}) were used to determine the detection limit of the system at a 10-second acquisition time. The system was then used to map the distribution of GNPs within a 12×11×2 mm{sup 3} slice excised from the center of a GNP-loaded ex vivo murine tumor sample; a total of 110 voxels (2.65×10{sup −3} cm{sup 3}) were imaged with 1.3-mm spatial resolution. Results: The detection limit of the current cone-beam benchtop L-shell XRF system was 0.003 mg/cm{sup 3} (3 ppm). Intratumoral GNP concentrations ranging from 0.003 mg/cm{sup 3} (3 ppm) to a maximum of 0.055 mg/cm{sup 3} (55 ppm) and average of 0.0093 mg/cm{sup 3} (9.3 ppm) were imaged successfully within the ex vivo tumor slice. Conclusion: The developed cone-beam benchtop L-shell XRF imaging system can immediately be used for imaging of ex vivo tumor samples containing low concentrations of GNPs. With minor finetuning/optimization, the system can be directly adapted for performing routine preclinical in vivo imaging tasks. Supported by NIH/NCI grant R01CA155446 This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

Scalable Parallel Methods for Analyzing Metagenomics Data at Extreme Scale

The field of bioinformatics and computational biology is currently experiencing a data revolution. The exciting prospect of making fundamental biological discoveries is fueling the rapid development and deployment of numerous cost-effective, high-throughput next-generation sequencing technologies. The result is that the DNA and protein sequence repositories are being bombarded with new sequence information. Databases are continuing to report a Moore’s law-like growth trajectory in their database sizes, roughly doubling every 18 months. In what seems to be a paradigm-shift, individual projects are now capable of generating billions of raw sequence data that need to be analyzed in the presence of already annotated sequence information. While it is clear that data-driven methods, such as sequencing homology detection, are becoming the mainstay in the field of computational life sciences, the algorithmic advancements essential for implementing complex data analytics at scale have mostly lagged behind. Sequence homology detection is central to a number of bioinformatics applications including genome sequencing and protein family characterization. Given millions of sequences, the goal is to identify all pairs of sequences that are highly similar (or “homologous”) on the basis of alignment criteria. While there are optimal alignment algorithms to compute pairwise homology, their deployment for large-scale is currently not feasible; instead, heuristic methods are used at the expense of quality. In this dissertation, we present the design and evaluation of a parallel implementation for conducting optimal homology detection on distributed memory supercomputers. Our approach uses a combination of techniques from asynchronous load balancing (viz. work stealing, dynamic task counters), data replication, and exact-matching filters to achieve homology detection at scale. Results for a collection of 2.56M sequences show parallel efficiencies of ~75-100% on up to 8K cores, representing a time-to-solution of 33 seconds. We extend this work with a detailed analysis of single-node sequence alignment performance using the latest CPU vector instruction set extensions. Preliminary results reveal that current sequence alignment algorithms are unable to fully utilize widening vector registers.

59 BASIC BIOLOGICAL SCIENCES↗

Learning reference governor for cycle-to-cycle combustion control with misfire avoidance in spark-ignition engines at high exhaust gas recirculation–diluted conditions

Cycle-to-cycle feedback control is employed to achieve optimal combustion phasing while maintaining high levels of exhaust gas recirculation by adjusting the spark advance and the exhaust gas recirculation valve position. The control development is based on a control-oriented model that captures the effects of throttle position, exhaust gas recirculation valve position, and spark timing on the combustion phasing. Under the assumption that in-cylinder pressure information is available, an adaptive extended Kalman filter approach is used to estimate the exhaust gas recirculation rate into the intake manifold based on combustion phasing measurements. The estimation algorithm is adaptive since the cycle-to-cycle combustion variability (output covariance) is not known a priori and changes with operating conditions. A linear quadratic regulator controller is designed to maintain optimal combustion phasing while maximizing exhaust gas recirculation levels during load transients coming from throttle tip-in and tip-out commands from the driver. During throttle tip-outs, however, a combination of a high exhaust gas recirculation rate and an overly advanced spark, product of the dynamic response of the system, generates a sequence of misfire events. In this work, an explicit reference governor is used as an add-on scheme to the closed-loop system in order to avoid the violation of the misfire limit. The reference governor is enhanced with model-free learning which enables it to avoid misfires after a learning phase. Experimental results are reported which illustrate the potential of the proposed control strategy for achieving an optimal combustion process during highly diluted conditions for improving fuel efficiency.

42 ENGINEERING↗

Proactive Frequency Stability Scheme: A Distributed Framework Based on Particle Filters and Synchrophasors

The reactive nature of traditional under-frequency load shedding schemes can lead to delayed response and unnecessary loss of load. This work presents a proactive framework for power system frequency stability. Bayesian filters and synchrophasors are leveraged to produce predictions after disturbances are detected. By being able to estimate the future state of frequency corrective actions can be taken before the system reaches a critical condition. This proactive approach makes it possible to optimize the response to a disturbance, which results in a decrease in the amount of compensation utilized. The framework is tested via Matlab simulations based on Kundur’s Two-Area System, and the IEEE 14-Bus System. Performance metrics are provided and evaluated against other contemporary solutions found in literature. During testing this framework outperformed other solutions by drastically reducing the amount of load dropped during compensation.

42 ENGINEERING↗

Improved mid infrared detector for high spectral or spatial resolution and synchrotron radiation use

When using bright, small effective size sources, such as synchrotron radiation light beam, for broadband spectroscopy at spectral or spatial high resolution for mid-IR FTIR measurements, a marked detectivity improvement can be achieved by setting up a device matching the detector optical étendue to that of the source. Further improvement can be achieved by reducing the background unmodulated flux and other intrinsic noise sources using a lower temperature cryogen, such as liquid helium. By the combined use of cooled apertures, cold reimaging optics, filters and adapted detector polarization, and preamplification electronics, the sensitivity of a HgCdTe photoconductive IR detector can be improved by a significant factor with respect to standard commercial devices (more than one order of magnitude on average over 6–20 μm region) and the usable spectral range extended to longer wavelengths. The performances of such an optimized detector developed on the AILES Beamline at SOLEIL are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum calculations on water in the KcsA channel cavity with permeant and non-permeant ions

Different ions in the pore of the KcsA channel behave differently, and we relate this to their solvation. We show that the selectivity is dependent, in part, on the solvation in the cavity (sometimes referred to as the vestibule, it is the region containing water molecules between the intracellular gate and the selectivity filter at the extracellular end of the pore). We have shown earlier that potassium is more dependent at the upper end of the cavity region on solvation by the threonines there, while sodium ion has more water molecules as ligands. In addition, sodium ion is placed asymmetrically, while potassium is nearly exactly symmetric with respect to the four-fold symmetry of the channel. We have now extended these calculations to rubidium and cesium ions, and find that rubidium solvation resembles that of potassium (and both are permeant ions), while cesium resembles sodium (and both are non-permeant), in terms of the geometry of up to eight hydrating, and four non-hydrating, water molecules. In each case, a maximum of 12 water molecules are relevant to the calculation. The placement of the water molecules in the two cases is essentially the same as found from the electron density in the X-ray structure of Zhou and MacKinnon. For Na+ and K+, we show that energy decreases from bulk to the cavity to the lowest position in the selectivity filter (accurate energy could not be calculated for the heavier ions). A separate calculation shows that fixing the Na+ ion at the position of the K+ minimum, followed by re-optimization produced a significantly modified system, not something that could be produced by thermal fluctuations. Moving the K+ into the Na+ position in the upper cavity led to a small increase in energy, ≈ 3 kBT, but was accompanied by large shifts in the positions of hydrating waters, which would create a major kinetic barrier. Therefore, thermal fluctuations could not invalidate the conclusions of the main calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

A novel nondestructive diagnostic method for mega-electron-volt ultrafast electron diffraction

Abstract A real-time, nondestructive, Bragg-diffracted electron beam energy, energy-spread and spatial-pointing jitter monitor is experimentally verified by encoding the electron beam energy and spatial-pointing jitter information into the mega-electron-volt ultrafast electron diffraction pattern. The shot-to-shot fluctuation of the diffraction pattern is then decomposed to two basic modes, i.e., the distance between the Bragg peaks as well as its variation (radial mode) and the overall lateral shift of the whole pattern (drift mode). Since these two modes are completely decoupled, the Bragg-diffraction method can simultaneously measure the shot-to-shot energy fluctuation from the radial mode with 2·10 −4 precision and spatial-pointing jitter from the drift mode having wide measurement span covering energy jitter range from 10 −4 to 10 −1 . The key advantage of this method is that it allows us to extract the electron beam energy spread concurrently with the ongoing experiment and enables online optimization of the electron beam especially for future high charge single-shot ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) experiments. Furthermore, real-time energy measurement enables the filtering process to remove off-energy shots, improving the resolution of time-resolved UED. As a result, this method can be applied to the entire UED user community, beyond the traditional electron beam diagnostics of accelerators used by accelerator physicists.

43 PARTICLE ACCELERATORS↗

Selection biases in empirical p(z) methods for weak lensing

To measure the mass of foreground objects with weak gravitational lensing, one needs to estimate the redshift distribution of lensed background sources. This is commonly done in an empirical fashion, i.e. with a reference sample of galaxies of known spectroscopic redshift, matched to the source population. In this paper, we develop a simple decision tree framework that, under the ideal conditions of a large, purely magnitude-limited reference sample, allows an unbiased recovery of the source redshift probability density function p(z), as a function of magnitude and colour. We use this framework to quantify biases in empirically estimated p(z) caused by selection effects present in realistic reference and weak lensing source catalogues, namely (1) complex selection of reference objects by the targeting strategy and success rate of existing spectroscopic surveys and (2) selection of background sources by the success of object detection and shape measurement at low signal to noise. For intermediate-to-high redshift clusters, and for depths and filter combinations appropriate for ongoing lensing surveys, we find that (1) spectroscopic selection can cause biases above the 10 per cent level, which can be reduced to ≈5 per cent by optimal lensing weighting, while (2) selection effects in the shape catalogue bias mass estimates at or below the 2 per cent level. Finally, this illustrates the importance of completeness of the reference catalogues for empirical redshift estimation.

79 ASTRONOMY AND ASTROPHYSICS↗

Generation of isolated attosecond pulses in the far field by spatial filtering with an intense few-cycle mid-infrared laser

We report theoretical calculations of high-order harmonic generation (HHG) of Xe with the inclusion of multielectron effects and macroscopic propagation of the fundamental and harmonic fields in an ionizing medium. By using the time-frequency analysis we show that the reshaping of the fundamental laser field is responsible for the continuum structure in the HHG spectra. We further suggest a method for obtaining an isolated attosecond pulse (IAP) by using a filter centered on axis to select the harmonics in the far field with different divergence. We also discuss the carrier-envelope-phase dependence of an IAP and the possibility to optimize the yield of the IAP. With intense few-cycle mid-infrared lasers, this offers a possible method for generating isolated attosecond pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimizing Kernel Machines Using Deep Learning

Building highly non-linear and non-parametric models is central to several state-of-the-art machine learning systems. Kernel methods form an important class of techniques that induce a reproducing kernel Hilbert space (RKHS) for inferring non-linear models through the construction of similarity functions from data. These methods are particularly preferred in cases where the training data sizes are limited and when prior knowledge of the data similarities is available. Despite their usefulness, they are limited by the computational complexity and their inability to support end-to-end learning with a task specific objective. On the other hand, deep neural networks have become the de facto solution for end-to-end inference in several learning paradigms. In this article, we explore the idea of using deep architectures to perform kernel machine optimization, for both computational efficiency and end-to-end inferencing. To this end, we develop the DKMO (Deep Kernel Machine Optimization) framework, that creates an ensemble of dense embeddings using Nystrõm kernel approximations and utilizes deep learning to generate task-specific representations through the fusion of the embeddings. Intuitively, the filters of the network are trained to fuse information from an ensemble of linear subspaces in the RKHS. Furthermore, we introduce the kernel dropout regularization to enable improved training convergence. Finally, we extend this framework to the multiple kernel case, by coupling a global fusion layer with pre-trained deep kernel machines for each of the constituent kernels. Using case studies with limited training data, and lack of explicit feature sources, we demonstrate the effectiveness of our framework over conventional model inferencing techniques.

97 MATHEMATICS AND COMPUTING↗

Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product Report

Objective analysis (OA) is a method of mapping unstructured data to a structured grid. In the context of scanning radar data, OA is used to interpolate data in antenna coordinates (range, azimuth, and elevation) onto a regularly spaced Cartesian grid (Trapp and Doswell 2000). The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product (VAP) uses the Python ARM Radar Toolkit (Py-ART), a data model-driven interactive architecture for working with weather radar data, to map the data to a Cartesian grid (Helmus and Collis 2016). MMCG, with Py-ART built in, has the ability to take radar data in antenna coordinates and map the gates to a Cartesian grid using inverse distance weight functions such as Cressman (square) and Barnes (exponential), but also can filter the data during the interpolation. MMCG also allows arbitrary formulations for the radius of influence, which are matched to particular radar scanning strategies. This creates a complex parameter space for optimizing the retention of storm structure detail while minimizing artifacts. MMCG takes data processed with ARM’s Corrected Precipitation Radar Moments in Antenna Coordinates (CMAC) VAP and maps it to a Cartesian grid as the output product. A variety of fields that have been mapped to the Cartesian grid are then saved to plots to complement each grid file.

54 ENVIRONMENTAL SCIENCES↗

An Iterative Approach for Solving the SCOPF Problem Applying LP, SOCP, and NLP Subproblems

We propose to develop efficient algorithms and software for the SCOPF problem. We will employ an iterative approach that will: a) use linear subproblems and other active set filtering techniques to identify the most important contingencies and drastically reduce the SCOPF model size; b) solve SOCP relaxations of the reduced SCOPF to converge to the neighborhood of the global optimal solution and establish a lower bound on the solution, and; c) use a non-convex, nonlinear interior-point solver, Artelys Knitro, to converge quickly to the optimal solution. To identify the most effective approach, we will experiment with several techniques to identify the tradeoffs between contingency subproblem complexity and fast solvability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In‐Silico Device Performance Prediction of Cosensitizer Dye Pairs for Dye‐Sensitized Solar Cells

Abstract Endeavors in the field of dye‐sensitized solar cells (DSCs) have shown great promise when adopting a data‐driven approach to materials discovery, such as successful molecular‐scale predictions of light‐harvesting chromophores. However, predictions of DSC dyes would become much more sophisticated if a molecular‐to‐macroscopic DSC device prediction methodology existed. Thereby, a fully computational pipeline is presented that predicts device‐performance parameters of DSCs which contain varying dye combinations. Optimal pairing of complementary dyes is identified via a data‐driven workflow that affords cosensitized DSCs with maximum power‐conversion efficiencies. Six high‐performing DSC dyes are paired with partner dyes that are screened from a database of 8488 compounds using sequential heuristic filters. Existing models that predict short‐circuit‐current density ( J SC ) and open‐circuit voltage ( V OC ) parameters are adapted to predict singly sensitized and cosensitized DSC performance. The predictions for J sc values of singly sensitized devices match experimental literature values with comparable accuracy to more computationally costly methods. Five out of six dye pairings are predicted to have greater J SC values when cosensitized compared to their corresponding singly sensitized devices, including two pairs that show strong J sc boosts of +13% and +12% when cosensitized. Thus, the prospect of an entirely in‐silico prediction pipeline for DSC performance that can be used to realize the fully automated design of optimized cosensitized DSCs is demonstrated.

14 SOLAR ENERGY↗

Nonlinear Ensemble Filtering with Diffusion Models: Application to the Surface Quasigeostrophic Dynamics

The intersection between classical data assimilation methods and novel machine learning techniques has attracted significant interest in recent years. Here, we explore another promising solution in which diffusion models are used to formulate a robust nonlinear ensemble filter for sequential data assimilation. Unlike standard machine learning methods, the proposed ensemble score filter (EnSF) is completely training free and can efficiently generate a set of analysis ensemble members. Here, in this study, we apply the EnSF to a surface quasigeostrophic model and compare its performance against the popular local ensemble transform Kalman filter (LETKF), which makes Gaussian assumptions in the analysis step. Numerical tests demonstrate that EnSF maintains stable performance in the absence of localization and for a variety of experimental settings. We find that while LETKF maintains optimal performance in the case of linear observations of the entire state and a perfect model, EnSF shows improvements over LETKF when nonlinear observations are assimilated and the system is subject to unexpected model errors. A spectral decomposition of the analysis results in this nonlinear observation regime shows that the largest improvements over LETKF occur at large scales (small wavenumbers), where LETKF lacks sufficient ensemble spread. Overall, this initial application of EnSF to a geophysical model of intermediate complexity motivates further development of the algorithm for more realistic problems.

Artificial intelligence↗