Search NASA⌕ Search

SEARCH · Search NASA

Results for “fractionalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Clinical Evaluation of a Laser Surface Scanning System in 120 Patients for Improving Daily Setup Accuracy in Fractionated Radiation Therapy

Purpose: To evaluate the clinical suitability of a specific optical surface imaging system to detect setup errors in fractionated radiation therapy. Methods and Materials: The setup correction accuracy of a 3-dimensional laser imaging system was analyzed for 6 different tumor locations with 20 patients each. For each patient, the setup corrections of the megavoltage computed tomography (MVCT) images of a TomoTherapy unit (TomoTherapy, Madison, WI) were compared with those of the laser system for the first 10 fractions. For the laser system, the reference surface either was obtained from the DICOM (Digital Imaging and Communications in Medicine) surface structure delineated on the planning computed tomography images or was acquired with the system itself at the first fraction after the MVCT-based setup correction. Data analysis was performed for both reference types. Results: By use of the DICOM reference image, systematic shifts between 3 and 9 mm were found, depending on the tumor location. For the optical reference, no clinically relevant systematic shifts were found. MVCT-based setup corrections were detected with high accuracy, and only small movements were observed during treatment. Conclusions: Using a reference image acquired with the laser system itself after MVCT-based setup correction appears more reliable than importing the DICOM reference surface. After generation of the optical reference, the laser system may be used to derive setup corrections over a certain number of fractions, but additional radiologic imaging may still be necessary on a regular basis (eg, weekly) or if the corrections of the optical system appear implausibly large. Nevertheless, such a combined application may help to reduce the imaging dose for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative Biological Effectiveness of Carbon Ions in a Rat Prostate Carcinoma In Vivo: Comparison of 1, 2, and 6 Fractions

Purpose: To determine the relative biological effectiveness (RBE) and the effective α/β ratio for local tumor control of a radioresistant rat prostate tumor (Dunning subline R3327-AT1) after 6 fractions of carbon ions and photons. Methods and Materials: A total of 82 animals with tumors in the distal thigh were treated with 6 fractions of either photons or carbon ions, by use of increasing dose levels and a 2-cm spread-out Bragg peak. Endpoints of the study were local control (no tumor recurrence within 300 days) and volumetric changes after irradiation. The resulting values for dose at 50% tumor control probability were used to determine RBE values. Including data for 1 and 2 fractions from a previous study, we estimated α/β ratios. Results: For 6 fractions, the values for dose at 50% tumor control probability were 116.6 ± 3.0 Gy for photons and 43.7 ± 2.3 Gy for carbon ions and the resulting RBE was 2.67 ± 0.15. The α/β ratio was 84.7 ± 13.8 Gy for photons and 66.0 ± 21.0 Gy for carbon ions. Using these data together with the linear-quadratic model, we estimated the maximum RBE to be 2.88 ± 0.27. Conclusions: The study confirmed the increased effectiveness of carbon ions relative to photons over the whole dose range for a highly radioresistant tumor. The maximum RBE below 3 is in line with other published in vivo data. The RBE values may be used to benchmark RBE models. Hypoxia seems to have a major impact on the radiation response, although this still has to be confirmed by dedicated experiments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Posttraumatic Stress Disorder After High-Dose-Rate Brachytherapy for Cervical Cancer With 2 Fractions in 1 Application Under Spinal/Epidural Anesthesia: Incidence and Risk Factors

Purpose: To investigate the psychological consequences of high-dose-rate brachytherapy with 2 fractions in 1 application under spinal/epidural anesthesia in the treatment of locally advanced cervical cancer. Methods and Materials: In 50 patients with locally advanced cervical cancer, validated questionnaires were used for prospective assessment of acute and posttraumatic stress disorder (ASD/PTSD) (Impact of Event Scale–Revision), anxiety/depression (Hospital Anxiety and Depression Scale), quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30/Cervical Cancer 24), physical functioning (World Health Organization performance status), and pain (visual analogue scale), before and during treatment and 1 week and 3 months after treatment. Qualitative interviews were recorded in open format for content analysis. Results: Symptoms of ASD occurred in 30% of patients 1 week after treatment; and of PTSD in 41% 3 months after treatment in association with this specific brachytherapy procedure. Pretreatment predictive variables explain 82% of the variance of PTSD symptoms. Helpful experiences were the support of the treatment team, psychological support, and a positive attitude. Stressful factors were pain, organizational problems during treatment, and immobility between brachytherapy fractions. Conclusions: The specific brachytherapy procedure, as performed in the investigated mono-institutional setting with 2 fractions in 1 application under spinal/epidural anesthesia, bears a considerable risk of traumatization. The source of stress seems to be not the brachytherapy application itself but the maintenance of the applicator under epidural anesthesia in the time between fractions. Patients at risk may be identified before treatment, to offer targeted psycho-social support. The patients' open reports regarding helpful experiences are an encouraging feedback for the treatment team; the reported stressful factors serve as a basis for improvement of patient management, especially regarding pain control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

30 Gy or 34 Gy? Comparing 2 Single-Fraction SBRT Dose Schedules for Stage I Medically Inoperable Non-Small Cell Lung Cancer

Purpose: To review outcomes of 2 single-fraction lung stereotactic body radiation therapy (SBRT) schedules used for medically inoperable early stage lung cancer. Methods and Materials: Patients in our institution have been treated on and off protocols using single-fraction SBRT (30 Gy and 34 Gy, respectively). All patients had node-negative lung cancer measuring ≤5 cm and lying ≥2 cm beyond the trachea-bronchial tree and were treated on a Novalis/BrainLAB system with the ExactTrac positioning system for daily image guidance. Results: For the interval from 2009 to 2012, 80 patients with 82 lesions were treated with single-fraction lung SBRT. Fifty-five patients (69%) and 25 patients (31%) received 30 Gy and 34 Gy, respectively. In a comparison of 30 Gy and 34 Gy cohorts, patient and tumor characteristics were balanced and median follow-up in months was 18.7 and 17.8, respectively. The average heterogeneity-corrected mean doses to the target were 33.75 Gy and 37.94 Gy for the 30-Gy and 34-Gy prescriptions, respectively. Comparing 30-Gy and 34-Gy cohorts, 92.7% and 84.0% of patients, respectively, experienced no toxicity (P was not significant), and had neither grade 3 nor higher toxicities. For the 30-Gy and 34-Gy patients, rates of 1-year local failure, overall survival, and lung cancer-specific mortality were 2.0% versus 13.8%, 75.0% versus 64.0%, and 2. 1% versus 16.0%, respectively (P values for differences were not significant). Conclusions: This is the largest single-fraction lung SBRT series yet reported. and it confirms the safety, efficacy, and minimal toxicity of this schedule for inoperable early stage lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Fraction Carbon-Ion Radiation Therapy for Patients 80 Years of Age and Older With Stage I Non-Small Cell Lung Cancer

Purpose: In an aging society, many senior citizens want less invasive treatment because of potential medical complications. The National Institute of Radiological Sciences has started to treat stage I lung cancer with single-fraction carbon-ion radiation therapy (CIRT) as a dose escalation prospective phase 1/2 trial. We evaluated the efficacy and safety of CIRT for patients 80 years of age and older, undergoing single-fraction CIRT. Methods and Materials: Peripheral non-small cell lung cancer patients who were treated with single-fraction CIRT were prospectively followed. We analyzed the data from among these patients 80 years of age and older. Results: There were 70 patients. Median age was 83 years (range: 80-89) and median follow-up period was 42.7 months (range: 12-128 months). Three-year local control, cause-specific survival, and overall survival rates were 88.0%, 81.6%, and 72.4%, respectively. Five-year local control, cause-specific survival, and overall survival rates were 85.8%, 64.9%, and 39.7%, respectively. There were no adverse effects higher than grade 2 either in the acute or late phase in terms of skin and lung. Analgesic agents were necessary for only 5 patients (7.1%), to relieve muscular or rib fracture pain caused by irradiation. Conclusions: Single-fraction CIRT was low-risk and effective, even for the elderly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for early-stage breast cancer in the adjuvant setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly Accelerated Irradiation in 5 Fractions (HAI-5): Feasibility in Elderly Women With Early or Locally Advanced Breast Cancer

Purpose: To investigate, in a prospective phase 1 to 2 trial, the safety and feasibility of delivering external beam radiation therapy in 5 fractions to the breast or thoracic wall, including boost and/or lymph nodes if needed, to women aged ≥65 years with breast cancer. Methods and Materials: Ninety-five patients aged ≥65 years, referred for adjuvant radiation therapy, were treated in 5 fractions over 12 days with a total dose of 28.5 Gy/5.7 Gy to the breast or thoracic wall and, if indicated, 27 Gy/5.4 Gy to the lymph node regions and 32.5 Gy/6.5 Gy to 34.5 Gy/6.9 Gy to the tumor bed. The primary endpoint was clinically relevant dermatitis (grade ≥2). Results: Mean follow-up time was 5.6 months, and mean age was 73.6 years. Clinically relevant dermatitis was observed in 11.6% of patients and only occurred in breast irradiation with boost (17.5% grade 2-3 vs 0% in the no-boost group). Although doses were high, treatment delivery with intensity modulated radiation therapy was swift, except for complex treatments, including lymph nodes for which single-arc volumetric modulated arc therapy was needed to reduce beam-on time. Conclusion: Accelerated radiation therapy in 5 fractions was technically feasible and resulted in low acute toxicity. Clinically relevant erythema was only observed in patients receiving a boost, but still at an acceptable rate. Although the follow-up is still short, the results on acute toxicity after accelerated radiation therapy were encouraging. A 5-fraction schedule is well tolerated in the elderly and may lower the threshold for radiation therapy in this population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1/2 Trial of 5-Fraction Stereotactic Radiosurgery With 5-mm Margins With Concurrent and Adjuvant Temozolomide in Newly Diagnosed Supratentorial Glioblastoma: Health-Related Quality of Life Results

Purpose: We report a longitudinal assessment of health-related quality of life (HRQOL) in patients with glioblastoma (GBM) treated on a prospective dose escalation trial of 5-fraction stereotactic radiosurgery (25-40 Gy in 5 fractions) with concurrent and adjuvant temozolomide. Methods: HRQOL was assessed using the European Organization for Research and Treatment of Cancer (EORTC) quality of life questionnaire core-30 (QLQ-C30) general, the EORTC quality of life questionnaire-brain cancer specific module (QLQ-BN20), and the M.D. Anderson Symptom Inventory–Brain Tumor (MDASI-BT). Questionnaires were completed at baseline and at every follow-up visit after completion of radiosurgery. Changes from baseline for 9 predefined HRQOL measures (global quality of life, physical functioning, social functioning, emotional functioning, motor dysfunction, communication deficit, fatigue, insomnia, and future uncertainty) were calculated at every time point. Results: With a median follow-up time of 10.4 months (range, 0.4-52 months), 139 total HRQOL questionnaires were completed by the 30 patients on trial. Compliance with HRQOL assessment was 76% at 12 months. Communication deficit significantly worsened over time, with a decline of 1.7 points per month (P=.008). No significant changes over time were detected in the other 8 scales of our primary analysis, including global quality of life. Although 8 patients (27%) experienced adverse radiation effects (ARE) on this dose escalation trial, it was not associated with a statistically significant decline in any of the primary HRQOL scales. Disease progression was associated with communication deficit, with patients experiencing an average worsening of 13.9 points per month after progression compared with 0.7 points per month before progression (P=.01). Conclusion: On this 5-fraction dose escalation protocol for newly diagnosed GBM, overall HRQOL remained stable and appears similar to historical controls of 30 fractions of radiation therapy. Tumor recurrence was associated with worsening communication deficit, and ARE did not correlate with a decline in HRQOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Micron-sized spinel crystals in high level waste glass compositions: Determination of crystal size and crystal fraction

The compositions utilized for immobilization of nuclear waste are controlled using glass property models to avoid the deleterious effects of crystallization in the high-level waste (HLW) vitrification melters. The type and size of the crystals that precipitate during melter operations (typically at 1150 °C) and idling (~ 1000 °C) are significantly impacted by glass composition and thermal history. This study was conducted to measure the impact of melt composition and heat treatment temperature on crystal size and fraction. A matrix of 31 multi-component glasses canvasing the expected Hanford HLW compositional space was developed and the glasses fabricated and heat treated at 850 = T = 950°C. The crystal filling fraction values, as determined by X-ray diffraction, varied from 0.2 to 41.0 wt%. Spinel filling fraction values ranged from 0.0 to 13.8 wt%. One glass of the matrix did not precipitate spinel and contained 0.2 wt% RuO 2 , which was assumed to be undissolved from the melting process. All compositions contained crystals in the as-quenched glass. All of the spinel based crystals present in the glasses were less than 10 µm in diameter, as determined by scanning electron microscopy. Composition and temperature dependent models were generated using the resulting data and the best model fit was obtained by only considering spinel filling fractions (R 2 = 0.83). Two glasses were unable to be characterized due to an inability to process the glass under the conditions of this study. Those glasses were utilized to give insight into a potential multi-component constraint to aid in future statistical composition designs.

Lonergan, C. E.↗

A facile electron microscopy method for measuring precipitate volume fractions in AlCuMg alloys

Precipitate volume fraction is an important parameter to estimate the strength of precipitation-hardened metals. In this study, a facile method was applied to measure the precipitate volume fractions in an age-hardened AlCuMg alloy. In this method, the precipitate volume fraction values can be obtained by multiplying the volume precipitate number densities with the averaged precipitate volumes, which can be easily measured in scanning electron microscopy and transmission electron microscopy, respectively. Compared with the conventional method, in which the specimen thickness has to be measured in transmission electron microscopy, the method proposed in this study is more facile to perform. - Highlights: Black-Right-Pointing-Pointer We have proposed a facile method to measure precipitate volume fractions for precipitation-hardened metals. Black-Right-Pointing-Pointer This technique works well for the square-shaped {theta} Prime -phase nano-precipitates in 2xxx aluminum alloys. Black-Right-Pointing-Pointer Interesting is that the proposed method is easy for materials scientists and engineers to perform.

36 MATERIALS SCIENCE↗

A quantifiable and automated volume fraction characterization technique for secondary and tertiary γ′ precipitates in Ni-based superalloys

Highlights: • A new, automated γ′ volume fraction characterization technique has been introduced for Ni-base superalloys. • New image processing techniques can automatically and accurately segment γ′ precipitates from the surrounding γ matrix. • CALPHAD and γ′ phase extraction measurements validate the new characterization technique. - Abstract: Ni-based superalloys are extensively used in high temperature, high stress applications. The presence of coherent γ′-Ni{sub 3}Al precipitates provides the requisite elevated temperature strength and creep resistance in these alloys. Therefore, quantification of the precipitate size distribution and volume fraction is essential for accurate model predictions and future alloy design. Current γ′ volume fraction characterization techniques suffer from a lack of precision and repeatability. Without a reproducible procedure, unacceptable variations and errors have plagued the past 6 decades of superalloys research and have inhibited the implementation of accurate precipitation models for these alloys. Through the use of high resolution, low kV, scanning electron microscopy and state-of-the-art image post-processing, a new, accurate γ′ characterization technique is presented. Using the new technique, secondary γ′ volume fractions in superalloy ME3 were calculated, and confirmed through phase extraction, thus opening the possibility for validation of presently used superalloy precipitation databases.

36 MATERIALS SCIENCE↗

Estimating the fraction of progeny virions that must incorporate APOBEC3G for suppression of productive HIV-1 infection

The contest between the host factor APOBEC3G (A3G) and the HIV-1 protein Vif presents an attractive target of intervention. The extent to which the A3G–Vif interaction must be suppressed to tilt the balance in favor of A3G remains unknown. We employed stochastic simulations and mathematical modeling of the within-host dynamics and evolution of HIV-1 to estimate the fraction of progeny virions that must incorporate A3G to render productive infection unsustainable. Using three different approaches, we found consistently that a transition from sustained infection to suppression of productive infection occurred when the latter fraction exceeded ∼0.8. The transition was triggered by A3G-induced hypermutations that led to premature stop codons compromising viral production and was consistent with driving the basic reproductive number, R{sub 0}, below unity. The fraction identified may serve as a quantitative guideline for strategies targeting the A3G–Vif axis. - Highlights: • We perform simulations and mathematical modeling of the role of APOBEC3G in suppressing HIV-1 infection. • In three distinct ways, we estimate that when over 80% of progeny virions carry APOBEC3G, productive HIV-1 infection would be suppressed. • Our estimate of this critical fraction presents quantitative guidelines for strategies targeting the APOBEC3G–Vif axis.

60 APPLIED LIFE SCIENCES↗

Linking Manganese Fractions and Organic Carbon in Soils of Contrasting Land Use Systems

Manganese (Mn) is an essential micronutrient that influences carbon (C) cycling by binding or oxidizing soil organic matter. Mn fractions in soil and their plant availability depend largely on soil pH, which is commonly altered by agricultural practices. Fractions of Mn in soils range from readily available (e.g., bioavailable Mn, exchangeable Mn) to stabilized (e.g., Mn-oxide minerals, Mn contained in silicates). Furthermore, the distribution of soil Mn with depth was assessed in contrasting land use systems (organic agriculture, conventional agriculture, and unmanaged forest) using a sequential extraction method that targets Mn fractions ranging in bioavailability. Both agricultural sites had similar amounts of total Mn but had available Mn (1–7% of total Mn) lower than that of the unmanaged forested site (15% of total Mn). Manganese and organic C were generally positively correlated, but this relationship depended on soil depth, Mn fractions, and concentrations, while land management change had little influence.

Crops↗

Improved Li + Transport in Polyacetal Electrolytes: Conductivity and Current Fraction in a Series of Polymers

Polymer electrolytes mitigate safety concerns surrounding flammable liquid electrolytes in lithium-ion batteries. Poly(ethylene oxide) (PEO) electrolytes demonstrate viable conductivity values (~1 × 10 -3 S/cm) at elevated temperatures (>70 °C) but a relatively low Li + current fraction (≤0.2) because strong Li + coordination inhibits cation mobility. We have developed a series of polyacetal electrolytes by systematically varying methylene oxide (MO) and ethylene oxide (EO) units in the polymer backbone. These materials maintain high oxygen-to-carbon ratios like PEO but offer improved ion transport, revealing trends of decreasing conductivity and increasing current fraction with respect to polymer composition. In particular, the increasing current fraction measured via the Bruce-Vincent method suggests that MO units improve Li+ mobility relative to anion mobility. Here, we calculate an overall efficacy (product of conductivity and current fraction) for each polymer/salt composition and identify two polymers - P(EO-MO) and P(EO-2MO) - that outperform PEO at high and low salt concentrations, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oxidative Catalytic Fractionation of Lignocellulosic Biomass under Non-alkaline Conditions

Biomass pretreatment methods are commonly used to isolate carbohydrates from biomass, but they often lead to modification, degradation, and/or low yields of lignin. Catalytic fractionation approaches provide a possible solution to these challenges by separating the polymeric sugar and lignin fractions in the presence of a catalyst that promotes cleavage of the lignin into aromatic monomers. In this work, we demonstrate an oxidative fractionation method conducted in the presence of a heterogeneous non-precious-metal Co-N-C catalyst and O 2 in acetone as the solvent. The process affords a 15 wt% yield of phenolic products bearing aldehydes (vanillin, syringaldehyde) and carboxylic acids (p-hydroxybenzoic acid, vanillic acid, syringic acid), complementing the alkylated phenols obtained from existing reductive catalytic fractionation methods. The oxygenated aromatics derived from this process have appealing features for use in polymer synthesis and/or biological funneling to value-added products, and the non-alkaline conditions associated with this process support preservation of the cellulose, which remains insoluble at reaction conditions and is recovered as a solid.

09 BIOMASS FUELS↗

Moment analysis for spatiotemporal fractional dispersion

The evolution of the first five nonnegative integer‐order spatial moments (corresponding to the mass, mean, variance, skewness, and kurtosis) are investigated systematically for spatiotemporal nonlocal, fractional dispersion. Three commonly used fractional‐order transport equations, including the time fractional advection‐dispersion equation (Time‐FADE), the fractal mobile‐immobile (MIM) equation, and the fully fractional advection‐dispersion equation (FFADE), are considered. Analytical solutions verify our numerical results and reveal the anomalous evolution of the moments. Following Adams and Gelhar's (1992) work on the classical ADE, we find that a simultaneous analysis of all moments is critical in discriminating between different nonlocal models. The evolution of dispersion among the subdiffusive to superdiffusive rates is then further explored numerically by a non‐Markovian random walk particle‐tracking method that can be used for any heterogeneous boundary or initial value problem in three dimensions. Both the analytical and the numerical results also show the similarity (at the early time) and the difference (at the late time) of moment growth for solutes in different phases (mobile versus total) described by the MIM models. Further simulations of the 1‐D bromide snapshots measured at the MADE experiments, using all three models with parameters fitted by the observed zeroth to fourth moments, indicate that (1) both the time and space nonlocality strongly affect the solute transport at the MADE site, (2) all five spatial moments should be considered in transport model selection and calibration because those up to the variance cannot effectively discriminate between nonlocal models, and (3) the log concentration should be used when evaluating the plume leading edge and the effects of space nonlocality.

58 GEOSCIENCES↗

Fractional correlated insulating states at one-third filled magic angle twisted bilayer graphene

Abstract The observation of superconductivity and correlated insulating states in twisted bilayer graphene has motivated much theoretical progress at integer fillings. However, little attention has been given to fractional fillings. Here we show that the three-peak structure of Wannier orbitals, dictated by the symmetry and topology of flat bands, facilitates the emergence of a state we name a “fractional correlated insulator” at commensurate fractional filling of ν = n ± 1/3. Specifically for the filling of 1/3 electrons per moiré unit cell, we show that short-range interactions lead to an extensive entropy due to the “breathing” degree of freedom of an irregular honeycomb lattice that emerges through defect lines. The leading further-range interaction lifts this degeneracy and selects a ferromagnetic nematic state that breaks AB/BA sublattice symmetry. The proposed fractional correlated insulating state might underlie the suppression of superconductivity at ν = 2 − 1/3 filling observed in ref. 1 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗