Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Using ARM Measurements to Understand and Reduce the Double ITCZ Biases in the Community Atmospheric Model

1. Understanding of the observed variability of ITCZ in the equatorial eastern Pacific. The annual mean precipitation in the eastern Pacific has a maximum zonal band north of the equator in the ITCZ where the maximum SST is located. During the boreal spring (referring to February, March, and April throughout the present paper), because of the accumulated solar radiation heating and oceanic heat transport, a secondary maximum of SST exists in the southeastern equatorial Pacific. Associated with this warm SST is also a seasonal transitional maximum of precipitation in the same region in boreal spring, exhibited as a weak double ITCZ pattern in the equatorial eastern Pacific. This climatological seasonal variation, however, varies greatly from year to year: double ITCZ in the boreal spring occurs in some years but not in other years; when there a single ITCZ, it can appear either north, south or at the equator. Understanding this observed variability is critical to find the ultimate cause of the double ITCZ in climate models. Seasonal variation of ITCZ south of the eastern equatorial Pacific: By analyzing data from satellites, field measurements and atmospheric reanalysis, we have found that in the region where spurious ITCZ in models occurs, there is a “seasonal cloud transition” — from stratocumulus to shallow cumulus and eventually to deep convection —in the South Equatorial Pacific (SEP) from September to April that is similar to the spatial cloud transition from the California coast to the equator. This seasonal transition is associated with increasing sea surface temperature (SST), decreasing lower tropospheric stability and large-scale subsidence. This finding of seasonal cloud transition points to the same source of model errors in the ITCZ simulations as in simulation of stratocumulus-cumulus-deep convection transition. It provides a test for climate models to simulate the relationships between clouds and large-scale atmospheric fields in a region that features a spurious double Inter-tropical Convergence Zone (ITCZ) in most models. This work is recently published in Yu et al. (2016). Interannual variation of ITCZ south of the eastern equatorial Pacific: By analyzing data from satellites, field measurements and atmospheric reanalysis, we have characterized the interannual variation of boreal spring precipitation in the eastern tropical Pacific and found the cause of the observed interannual variability. We have shown that ITCZ in this region can occur as a single ITCZ along the Equator, single ITCZ north of the Equator, single ITCZ south of the Equator, and double ITCZ on both sides of the Equator. We have found that convective instability only plays a secondary role in the ITCZ interannual variability. Instead, the remote impact of the Pacific basin-wide SST on the horizontal gradient of surface pressure and wind convergence is the primary driver of this interannual variability. Results point to the need to include moisture convergence in convection schemes to improve the simulation of precipitation in the eastern tropical Pacific. This result has been recently submitted for publication (Yu and Zhang 2016). 2. Improvement of model parameterizations to reduce the double ITCZ bias We analyzed the current status of climate model performance in simulating precipitation in the equatorial Pacific. We have found that the double ITCZ bias has not been reduced in CMIP5 models relative to CMIP4 models. We have characterized the dynamic structure of the common bias by using precipitation, sea surface temperature, surface winds and sea-level. Results are published in Zhang et al. (2015): Since cumulus convection plays a significant role in the double ITCZ behavior in models, we have used measurements from ARM and other sources to carry out a systematic analysis of the roles of shallow and deep convection in the CAM. We found that in both CAM4 and CAM5, when the intensity of deep convection decreases as a result of parameterization change, the intensity of shallow convection increases, leading to very different changes in precipitation partitions but little change in the total precipitation. The different precipitation partition however can manifest themselves in other measures of model performances including temperature and humidity. This study points to the need to treat model physical parameterizations as integrated system rather than individual components. Results from this study are published in Wang and Zhang (2013). Since shallow convection interacts with the deep convection scheme and surface turbulence to trigger the double ITCZ, we studied methods to improve the shallow convection scheme in climate models. We investigated the bulk budgets of the vertical velocity and its parameterization in convective cores, convective updrafts, and clouds by using large-eddy simulation (LES) of four shallow convection cases including one from ARM. We proposed optimal forms of the Simpson and Wiggert equation to calculate the vertical velocity in bulk mass flux convection schemes for convective cores, convective updrafts, and convective clouds as parameterization schemes. The new scheme is published in Wang and Zhang (2014). By using long-term radar-based ground measurements from ARM, we derived a scale-aware inhomogeneity parameterization of cloud liquid water in climate models. We found a relationship between the inhomogeneity parameter and the model grid size as well as atmospheric stability. This relationship is implemented in the CESM to describe the subgrid-scale cloud inhomogeneity. Relative to the default CESM with the finite-volume dynamic core at 2-degree resolution, the new parameterization leads to smaller cloud inhomogeneity and larger cloud liquid-water path in high latitudes, and the opposite effect in low latitudes, with the regional impact on shortwave cloud radiation effect of up to 10 W/m 2 . This is due to both the smaller (larger) grid size in high (low) latitudes in the longitude-latitude grid setting of CESM and the more stable (unstable) atmosphere. This parameterization is expected lead to more realistic simulation of tropical precipitation in high-resolution models. Results from this study are reported in Xie and Zhang (2015).

54 ENVIRONMENTAL SCIENCES↗

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)↗

Evaluating Transactive Controls of Integrated Transmission and Distribution Systems using the Framework for Network Co-Simulation

With an ever-evolving power grid, concerns regarding how to maintain system stability, efficiency, and reliability remain constant because of increasing uncertainties and decreasing rotating inertia. To alleviate some of these concerns, demand response represents a viable solution and is virtually an untapped resource in the current power grid. This work describes a hierarchical control framework that allows coordination between distributed energy resources and demand response. This control framework is composed of two control layers: a coordination layer that ensures aggregations of resources are coordinated to achieve system objectives and a device layer that controls individual resources to assure the predetermined power profile is tracked in real time. Large-scale simulations are executed to study the hierarchical control, requiring advancements in simulation capabilities. Technical advancements necessary to investigate and answer control interaction questions, including the Framework for Network Co-Simulation platform and Arion modeling capability, are detailed. Insights into the interdependencies of controls across a complex system and how they must be tuned, as well as validation of the effectiveness of the proposed control framework, are yielded using a large-scale integrated transmission system model coupled with multiple distribution systems.

demand response↗

From Event Data to Wind Power Plant DQ Admittance and Stability Risk Assessment

This paper presents a dynamic event data-based stability risk assessment method for power grids with high penetrations of inverter-based resources (IBRs). This method relies on obtaining the IBRs' DQ admittance through dynamic event data and computing the system's eigenvalues based on the admittance models. Two critical technologies are employed in this research, including time-domain and frequency-domain data fitting and dq-frame voltage and current signal derivation. The first technology is key to obtaining the s-domain expressions from the transient response data, and the s-domain DQ admittance model from the frequency-domain measurements. The second technology is key to obtaining the dq-frame voltage and current signals from either the three-phase instantaneous measurements or the phasor measurement unit (PMU) data. The method is illustrated using data generated from a Type-4 wind power plant modeled in PSCAD. This paper demonstrates the technical feasibility of the proposed approach.

17 WIND ENERGY↗

NASA Langley FUN3D Analyses in Support of the 1st AIAA Stability and Control Prediction Workshop

This work summarizes the results of FUN3D analyses conducted for the 1st AIAA Stability and Control Workshop on behalf of participants from the NASA Langley Research Center. The workshop was created to establish best practices for the prediction of stability and control derivatives using computational fluid dynamics and assess the limitations of these methods when those best practices are applied. The inaugural workshop considered the ONERA version of the NASA/Boeing Common Research Model, which includes the wing, body, horizontal tail, and a vertical tail designed by ONERA. Wind tunnel data at small sideslip angles remain unpublished and served as ‘blind’ data for computational comparisons. The present research generated workshop test case data using the NASA FUN3D code, which is a parallelized, unstructured, node-based, finite-volume discretization, Reynolds-averaged Navier-Stokes flow solver. Steady- state numerical simulations were conducted for workshop test cases investigating the following: grid convergence, Mach number effect on static stability, wind tunnel sting increments, static stability-derivative calculations, and a sideslip angle sweep. Results were generated for two series of unstructured, mixed-element grids, one set provided by the workshop and another set created using the HeldenMesh grid generation software. The results provided include total- and component-level breakdowns of the force and moment coefficients, in addition to sectional pressure distributions for the wing and tail components for comparisons to wind tunnel data.

CFD↗

Tri-Sectional Approximation of the Shortest Path to Long-Term Voltage Stability Boundary with Distributed Energy Resources

Ensuring long-term voltage stability is critical for reliable operations of power grids. High share of distributed energy resources (DERs) can create complicated system operation modes that may invalidate the traditional long-term voltage stability analysis based on typical operation modes. To address this challenge, this paper investigates how to compute the shortest path to the voltage stability boundary in the DER aggregated load space with large dispersion. Instead of working in the Euclidean space, we establish the analysis and computations on the algebraic power flow manifold to better capture the curvature change of the shortest path along the direction of losing stability. A modified optimal control framework is presented for obtaining the ground-truth of the smooth shortest path on the manifold. To efficiently and accurately solve for the shortest path, we further leverage the geometric features of the power flow manifold and propose a tri-sectional approximation model that is scalable for large-scale systems. Several numerical examples, up to the 1354-bus system, with different DER penetration levels and high dimensional renewable power injection variations are evaluated. The simulation results demonstrate that the tri-sectional approximation achieves high accuracy and efficiency to approximate the shortest path to the voltage stability boundary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AN INTELLIGENT SENSOR FRAMEWORK FOR THE POWER GRID

The number of sensors connected to the electric power system is expected to grow by several orders of magnitude by 2020. However, the information networks which will transmit and analyze the resulting data are ill-equipped to handle the resulting volume with reliable real-time delivery. Without the ability to manage and use this data, deploying sensors such as phasor measurement units in the transmission system and smart meters in the distribution system will not result in the desired improvements in the power grid. The ability to exploit the massive data being generated by new sensors would allow for more efficient flow of power and increased survivability of the grid. Additionally, the power systems of today are not capable of managing two-way power flow to accommodate distributed generation capabilities due to concerns about system stability and lack of system flexibility. The research that we are performing creates a framework to add 'intelligence' to the sensors and actuators being used today in the electric power system. Sensors that use our framework will be capable of sharing information through the various layers of the electric power system to enable two-way information flow to help facilitate integration of distributed resources. Several techniques are considered including use of peer-to-peer communication as well as distributed agents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems: Preprint

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Note: Triggering behavior of a vacuum arc plasma source

Axial symmetry of discharge is very important for application of vacuum arc plasma. It is discovered that the triggering method is a significant factor that would influence the symmetry of arc discharge at the final stable stage. Using high-speed multiframe photography, the transition processes from cathode-trigger discharge to cathode-anode discharge were observed. It is shown that the performances of the two triggering methods investigated are quite different. Arc discharge triggered by independent electric source can be stabilized at the center of anode grid, but it is difficult to achieve such good symmetry through resistance triggering. It is also found that the triggering process is highly correlated to the behavior of emitted electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

A Global Real-Time Superlab: Enabling High Penetration of Power Electronics in the Electric Grid

The Global Real-Time Superlaboratory (Global RT Superlab) represents a vendor-neutral distributed platform based on the virtual interconnection of digital real-time simulators (DRTSs) and hardware-in-the-loop (HIL) setups hosted at eight geographically distributed laboratories in the United States and Europe (Figure 1). This article describes the efforts toward the realization of this largescale virtual infrastructure and explains a demonstration of the multilab setup for simulation and testing of next-generation global power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cooperative Game Theory-based Approach to Under-frequency Load Shedding Control

This paper proposes a cooperative game theory-based under-frequency load shedding (UFLS) approach for frequency stability and control in power systems. UFLS is a crucial factor for frequency stability and control especially in power grids with high penetration of renewable energy sources and restructured power systems. Conventional UFLS methods, most of which are off-line, usually shed fixed amounts of predetermined loads based on a predetermined schedule which can lead to over or under curtailment of load. This paper presents a co-operative game theory-based two-stage strategy to effectively and precisely determine locations and amounts of loads to be shed for UFLS control. In the first stage, the total amount of loads to be shed, also referred to as deficit in generation or the disturbance power, is computed using the initial rate of change of frequency (ROCOF) referred to the equivalent inertial center. In the second stage, the Shapley value, one of the solution concepts of cooperative game theory, is used to determine load shedding amounts and locations. The proposed method is implemented on the reduced 9-bus 3-machine Western Electricity Coordinating Council (WECC) system and simulated on Real-time Digital Simulators (RTDS). The results show that the proposed UFLS approach can effectively return the system to normal state after disturbances.

42 ENGINEERING↗

ML-Based Power System Stability Assessment Considering Network Topology Changes: WECC 20,000+ Bus System Case Study

Modern power grids are fast-changing and thus require real-time monitoring and online stability assessment. With the rapid development of machine learning (ML) techniques, using data-driven models to provide fast and accurate estimations of power system stability marginal information, such as frequency nadir for frequency stability and critical clearing time (CCT) for transient stability, have become possible. However, despite the numerous research on ML-based methods for frequency nadir and CCT prediction, there is limited work on the impact of different network topology changes. Furthermore, most previous studies only focused on small or synthetic systems, and there is a lack of research on actual large power system models. In this paper, the above issues are addressed by studying the actual U.S. Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. Massive simulations are conducted in PowerWorld Simulator to study the impact of various topology change scenarios on both frequency stability and transient stability. System operating information is extracted from the success dispatch cases of various network topologies to generate a comprehensive dataset for ML-based models. Two ML methods, random forest (RF) and multilayer perceptron (MLP) neural network, are trained and tested for both frequency nadir prediction and CCT prediction. Test results have proven the models are capable of online stability assessment for large power networks such as the WECC system with sufficient accuracy.

critical clearing time↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗