Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

How Dusty Is Alpha Centauri? Excess or Non-excess over the Infrared Photospheres of Main-sequence Stars

Context. Debris discs around main-sequence stars indicate the presence of larger rocky bodies. The components of the nearby, solar-type binary Centauri have metallicities that are higher than solar, which is thought to promote giant planet formation. Aims. We aim to determine the level of emission from debris around the stars in the Cen system. This requires knowledge of their photospheres.Having already detected the temperature minimum, Tmin, of CenA at far-infrared wavelengths, we here attempt to do the same for the moreactive companion Cen B. Using the Cen stars as templates, we study the possible eects that Tmin may have on the detectability of unresolveddust discs around other stars. Methods.We used Herschel-PACS, Herschel-SPIRE, and APEX-LABOCA photometry to determine the stellar spectral energy distributions in thefar infrared and submillimetre. In addition, we used APEX-SHeFI observations for spectral line mapping to study the complex background around Cen seen in the photometric images. Models of stellar atmospheres and of particulate discs, based on particle simulations and in conjunctionwith radiative transfer calculations, were used to estimate the amount of debris around these stars. Results. For solar-type stars more distant than Cen, a fractional dust luminosity fd LdustLstar 2 107 could account for SEDs that do not exhibit the Tmin eect. This is comparable to estimates of fd for the Edgeworth-Kuiper belt of the solar system. In contrast to the far infrared,slight excesses at the 2:5 level are observed at 24 m for both CenA and B, which, if interpreted as due to zodiacal-type dust emission, wouldcorrespond to fd (13) 105, i.e. some 102 times that of the local zodiacal cloud. Assuming simple power-law size distributions of the dustgrains, dynamical disc modelling leads to rough mass estimates of the putative Zodi belts around the Cen stars, viz.4106 M$ of 4 to 1000 msize grains, distributed according to n(a) a3:5. Similarly, for filled-in Tmin emission, corresponding Edgeworth-Kuiper belts could account for103 M$ of dust. Conclusions. Our far-infrared observations lead to estimates of upper limits to the amount of circumstellar dust around the stars CenA and B.Light scattered andor thermally emitted by exo-Zodi discs will have profound implications for future spectroscopic missions designed to searchfor biomarkers in the atmospheres of Earth-like planets. The far-infrared spectral energy distribution of Cen B is marginally consistent with thepresence of a minimum temperature region in the upper atmosphere of the star. We also show that an Cen A-like temperature minimum mayresult in an erroneous apprehension about the presence of dust around other, more distant stars.

metallicities↗

Comparing Planetary Helicopter Brownout Observations with Numerical Predictions for Ingenuity

Ingenuity is considered the Martian equivalent of the Wright Flyer. Its sustained flights on Mars proved that non-terrestrial powered flight is possible, even on planets with thin atmospheres. However, Ingenuity was small and carried no payload. Future planetary rotorcraft will be bigger and heavier to accomplish new scientific and exploratory goals. On dusty planets, the associated increase in rotor thrust poses a potential challenge well known to helicopter pilots who have flown in desert environments: dust clouds forming during take-off and landing due to rotor wash, referred to as brownout. This work evaluates the effectiveness of existing numerical simulation models in predicting the severity of this phenomenon for planetary rotorcraft. We compare the output of a CFD-based dust mobilization model with data recently gathered using image processing techniques of Ingenuity’s flights. The simulation results suggest that the sensitivity of the wall friction velocity to the rotorcraft height may be lower than previously assessed. We further evaluate the sensitivity of the total mass of mobilized dust to other model parameters such as the sandblasting efficiency and the saltation threshold velocity. Finally, we discuss the limitations of this comparison due to uncertainty in both the observation and the numerical model.

HEC↗

Fidelity Analysis of Sampled Imaging Systems

Many modeling, simulation and performance analysis studies of sampled imaging systems are inherently incomplete because they are conditioned on a discrete-input, discrete-output model that only accounts for blurring during image acquisition and additive noise. For those sampled imaging systems where the effects of digital image acquisition, digital filtering and reconstruction are significant, the modeling, simulation and performance analysis should be based on a more comprehensive continuous-input, discrete-processing, continuous-output end-to-end model. This more comprehensive model should properly account for the low-pass filtering effects of image acquisition prior to sampling, the potentially important noiselike effects of the aliasing caused by sampling, additive noise due to device electronics and quantization, the generally high-boost filtering effects of digital processing, and the low-pass filtering effects of image reconstruction. This model should not, however, be so complex as to preclude significant mathematical analysis, particularly the mean-square (fidelity) type of analysis so common in linear system theory. We demonstrate that, although the mathematics of such a model is more complex, the increase in complexity is not so great as to prevent a complete fidelity-metric analysis at both the component level and at the end-to-end system level: that is, computable mean-square-based fidelity metrics are developed by which both component-level and system-level performance can be quantified. In addition, we demonstrate that system performance can be assessed qualitatively by visualizing the output image as the sum of three component images, each of which relates to a corresponding fidelity metric. The cascaded, or filtered, component accounts for the end-to-end system filtering of image acquisition, digital processing, and image reconstruction; the random noise component accounts for additive random noise, modulated by digital processing and image reconstruction filtering; and the aliased noise component accounts for the frequency folding effect of sampling, modulated by digital processing and image reconstruction filtering.

Park, Stephen K.↗

Three Dimensional Imaging with Multiple Wavelength Speckle Interferometry

We present the design, modeling, construction, and results of a three-dimensional imager based upon multiple-wavelength speckle interferometry. A surface under test is illuminated with tunable laser light in a Michelson interferometer configuration while a speckled image is acquired at each laser frequency step. The resulting hypercube is Fourier transformed in the frequency dimension and the beat frequencies that result map the relative offsets of surface features. Synthetic wavelengths resulting from the laser tuning can probe features ranging from 18 microns to hundreds of millimeters. Three dimensional images will be presented along with modeling results.

speckle interferometry↗

Harnessing Artificial Intelligence for Medical Diagnosis and Treatment During Space Exploration Missions

From May 8th to June 9th, 2023, I had the opportunity to participate in an experiential learning experience at Johnson Space Center in Houston, TX with Exploration Medical Capability (ExMC), an element of the NASA Human Research Program. During this research experience, I was not only able to work on the above titled research project, but also gain an immense exposure to the field of aerospace medicine, make numerous connections within the field, tour NASA facilities, as well as travel to the Aerospace Medical Association Annual Conference (AsMA) in New Orleans. To briefly introduce my project, it is well understood that the medical capabilities available to crew medical officers (CMOs) on the International Space Station will be different than the capabilities available and needed during deep space exploration missions to the Moon, Mars, and beyond. Ground support is particularly limited due to distance, communication delays (or lack of communication), and lack of resupply. Therefore, to support medical care by CMOs on these missions, robust clinical decision support systems (CDSSs) must be designed. The recent publication and public launch of generative artificial intelligence (AI) tools based upon large language models (LLM) such as ChatGPT provides the opportunity to create a smart assistant for onboard triage, diagnosis, and treatment of medical conditions. Ultimately, the overall purpose of the project was to research what AI tools currently exist or are in development, and to see how they might be implemented onboard during exploration class spaceflights of the future. The ExMC element is actively developing several tools to be used in preparation for and during deep space exploration missions. One of those tools, known as IMPACT, is a probabilistic risk assessment model which can be used to propose a desired medical system (based on mass and volume) and suggest the clinical outcomes likely to occur for a design reference mission (DRM). The group recently presented the IMPACT model and a DRM of interest titled “Modified Long Duration Lunar Orbital and Lunar Surface” (mLDLOLS) at the recent AsMA conference. The mLDLOLS mock mission is a 9 month and 6-day deep space exploration mission consisting of time in Moon’s orbit (3 months on the Gateway space station), on the lunar surface (3 months within habitat), and another 3 months on Gateway before return to Earth. For this DRM, IMPACT ultimately outlined a preferred medical system that was then associated with medical conditions considered to be most likely based on frequency, most likely to cause astronaut task time loss (TTL), most likely to cause return to definitive care (RTDC), and most likely cause loss of crew life (LOCL). IMPACT also highlighted the medical capabilities/skills that would be required to care for those medical conditions, such as performing a history of present illness or musculoskeletal exam with ultrasound. The primary objective of the project was to perform a survey of the AI tools and systems applicable to the conditions outlined for the proposed mLDLOLS mission. Using PubMed (including most relevant MeSH terms) and Google Scholar, we then created a robust annotated bibliography organized by condition. The 56-page and over 500 reference annotated bibliography was subsequently used to create a review outline that would become the basis for drafting of a future publication. For the review outline, we took those medical conditions researched within the annotated bibliography (condition-based approach) and deployed a systems-based approach, combining those medical conditions and related tools into ten categories. These categories included general/all-purpose CDSSs, tools to diagnose or manage respiratory, dermatologic, neurologic, auditory and vestibular, ophthalmic, musculoskeletal, infection-associated, and gynecologic conditions, as well as tools that could be deployed in the setting of trauma/emergency. With the completion of the 30-page outline, we then began drafting the review paper. To conclude the research experience, I presented the findings from our survey to the ExMC Clinical and Science team. With these objectives, I ultimately learned about the number of AI tools that exist today to assist medical professionals with the triage, diagnosis, and management of several medical conditions. These tools can span from chatbot assistants to help triage knee pain to vision transformer models that can identify ophthalmic conditions based on ocular surface images captured with a cell phone. We also highlighted the current gaps that exist in the literature alongside the advancements that are needed to make the desired CDSS for deep space exploration missions. With this experience, I certainly confirmed an existing career goal and identified several additional skills needed to become an aerospace medical doctor including knowledge of critical care in an extreme medicine setting, aerospace engineering and human integration systems, artificial intelligence, machine learning, and risk models. I also identified numerous transferable skills for this career goal including the basic knowledge of medicine (MD), deployment of the scientific method for critical thought about new scientific questions (PhD), review of published literature, including creating an annotated bibliography (PhD), as well as detailed scientific writing (PhD). The results of my research will likely guide the design of an all-encompassing onboard medical assistant for use during deep space exploration missions of the future. I plan on sharing the outcomes from this experience with my peers at a student seminar in the Fall semester on August 30th. During the seminar, I will detail the project, my experience at NASA and AsMA, as well as offer best practice guidelines for students entertaining similar experiences or careers. In conclusion, I would like to thank the WVU School of Medicine, Research and Graduate Education office, as well as NASA ExMC for the unwavering support of this life-changing experience.

Ryan A. Lacinski↗

Long-term spatial distributions and trends of the latent heat fluxes over the global cropland ecosystem using multiple satellite-based models

Estimating cropland latent heat flux (LE) from continental to global scales is vital to modeling crop production and managing water resources. Over the past several decades, numerous LE models were developed, such as the moderate resolution imaging spectroradiometer LE (MOD16) algorithm, revised remote sensing-based Penman–Monteith LE algorithm (RRS), the Priestley–Taylor LE algorithm of the Jet Propulsion Laboratory (PT-JPL) and the modified satellite-based Priestley-Taylor LE algorithm (MS-PT). However, these LE models have not been directly compared over the global cropland ecosystem using various algorithms. In this study, we evaluated the performances of these four LE models using 34 eddy covariance (EC) sites. The results showed that mean annual LE for cropland varied from 33.49 to 58.97 W/m2 among the four models. The inter-annual LE slightly increased during 1982– 2009 across the global cropland ecosystem. All models had acceptable performances with the coefficient of determination (R2 ) ranging from 0.4 to 0.7 and a root mean squared error (RMSE) of approximately 35 W/m2 . MS-PT had good overall performance across the cropland ecosystem with the highest R2 , lowest RMSE and a relatively low bias. The reduced performances of MOD16 and RRS, with R2 ranging from 0.4 to 0.6 and RMSEs from 30 to 39 W/m2 , might be attributed to empirical parameters in the structure algorithms and calibrated coefficients.

54 ENVIRONMENTAL SCIENCES↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

A New View of Mars

During the last 8 years the US has successfully sent 2 major spacecraft to Mars 1z?der= planet. The Mars Global Surveyor spacecraft (IGS), which started operating at Mars in Sept 1977 and Mars Odyssey spacecraft that started operating in Jan 2002, are both operational and collecting data, including 1.5 meter pixel imagery, them spectrometry, magnetometry, altimeter/radiometry, gamma ray and neutron counts. imaging spectrometry, and gravity. The two orbiters are conceptually similar to Earth orbiting spacecraft in that their primary purpose is to observe, monitor, and measure a variety of parameters about the planet and report any changes that might be occurring on the surfaces and in the atmosphere. As a result we now have detailed physical descriptions of the shape, topography, magnetism. surface roughness, thermal inertia, atmospheric pressure and temperature, the distribution of hydrogen in the top meter of the crust, models for the planetary interior based upon data, and an image set that portrays much of the history of the past 3 billion years. understand how the planet came to be this way.

Smith, David E.↗

Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability

Purpose: The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. Methods: A multisized image quality phantom (37, 30, 23, 18.5, and 12 cm physical diameter) was imaged on a SOMATOM Force scanner (Siemens Medical Solutions) under variable dose, kVp, and tube current modulation settings. Images were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) with iterative strengths of 3, 4, and 5. Image quality was assessed in terms of the noise power spectrum (NPS), task transfer function (TTF), and detectability index for a range of detection tasks (contrasts of approximately 45, 90, 300, −900, and 1000 HU, and 2–20 mm diameter) based on a non-prewhitening matched filter model observer with eye filter. Results: Image noise magnitude decreased with decreasing phantom size, increasing dose, and increasing ADMIRE strength, offering up to 64% noise reduction relative to FBP. Noise texture in terms of the NPS was similar between FBP and ADMIRE (<5% shift in peak frequency). The resolution, based on the TTF, improved with increased ADMIRE strength by an average of 15% in the TTF 50% frequency for ADMIRE-5. The detectability index increased with increasing dose and ADMIRE strength by an average of 55%, 90%, and 163% for ADMIRE 3, 4, and 5, respectively. Assessing the impact of mA modulation for a fixed average dose over the length of the phantom, detectability was up to 49% lower in smaller phantom sections and up to 26% higher in larger phantom sections for the modulated scan compared to a fixed tube current scan. Overall, the detectability exhibited less variability with phantom size for modulated scans compared to fixed tube current scans. Conclusions: Image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose. The use of tube current modulation resulted in more consistent image quality with changing phantom size.

60 APPLIED LIFE SCIENCES↗

Ringing Artifact Reduction Method for Ultrasound Reconstruction Using Multi-Agent Consensus Equilibrium

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing Technique (SAFT) rapidly produce acceptable results but with significant artifacts. Recently, ultrasound model-based iterative reconstruction (UMBIR) approaches have shown significant improvements over SAFT. However, even these methods produce ringing artifacts due to the high fractional-bandwidth of the excitation signal.In this paper, we propose a ringing artifact reduction method for ultrasound image reconstruction that uses a multi-agent consensus equilibrium (RARE-MACE) framework. Our approach integrates a physics-based forward model that accounts for the propagation of a collimated ultrasonic beam in multi-layered media, a spatially varying image prior, and a denoiser designed to suppress the ringing artifacts that are characteristic of reconstructions from high-fractional bandwidth ultrasound sensor data. We test our method on simulated and experimental measurements and show substantial improvements in image quality compared to SAFT and UMBIR.

Alanazi, Abdulrahman M↗

Tightly-coupled camera/LiDAR integration for point cloud generation from GNSS/INS-assisted UAV mapping systems

Unmanned aerial vehicles (UAVs) equipped with integrated global navigation satellite systems/inertial navigation systems (GNSS/INS) together with cameras and/or LiDAR sensors are being widely used for topographic mapping in a variety of applications such as precision agriculture, coastal monitoring, and archaeological documentation. Integration of image-based and LiDAR point clouds can provide a comprehensive 3D model of the area of interest. For such integration, ensuring a good alignment between data from the different sources is critical. Although many works have been conducted on this topic, there is still a need for a rigorous integration approach that minimizes the discrepancy between camera and LiDAR data caused by inaccurate system calibration parameters and/or trajectory artifacts. This study proposes an automated tightly-coupled camera/LiDAR integration workflow for GNSS/INS-assisted UAV systems. The proposed strategy is conducted in three main steps. First, an image-based point cloud is generated using a LiDAR/GNSS/INS-assisted structure from motion (SfM) strategy. Then, feature correspondences between image-based and LiDAR point clouds are automatically identified. Finally, an integrated-bundle adjustment procedure including image points, LiDAR raw measurements, and GNSS/INS information is conducted to minimize the discrepancy between point clouds from different sensors while estimating system calibration parameters and refining the trajectory information. The proposed SfM strategy and integration framework are evaluated using five datasets. The SfM results show that using LiDAR data can facilitate feature matching and further increase the number of reconstructed 3D points. The experimental results also illustrate that the developed automated camera/LiDAR integration strategy is capable of accurately estimating system calibration parameters to achieve good alignment among camera/LiDAR data from single/multiple systems. Finally, an absolute accuracy in the range of 3–5 cm is achieved for the image/LiDAR point clouds after the integration process.

42 ENGINEERING↗

Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed. Methods: Density variations across the cortex were modeled as a function of the cortical thickness and density, location of the cortex, density of surrounding tissues, and imaging blur. High resolution micro-CT data of cadaver proximal femurs were analyzed to determine a relationship between cortical thickness and density. This thickness-density relationship was used as prior information to be incorporated in the model to obtain accurate measurements of cortical thickness and density from clinical CT volumes. The method was validated using micro-CT scans of 23 cadaver proximal femurs. Simulated clinical CT images with different voxel sizes were generated from the micro-CT data. Cortical thickness and density were estimated from the simulated images using the proposed method and compared with measurements obtained using the micro-CT images to evaluate the effect of voxel size on the accuracy of the method. Then, 19 of the 23 specimens were imaged using a clinical CT scanner. Cortical thickness and density were estimated from the clinical CT images using the proposed method and compared with the micro-CT measurements. Finally, a case-control study including 20 patients with osteoporosis and 20 age-matched controls with normal bone density was performed to evaluate the proposed method in a clinical context. Results: Cortical thickness (density) estimation errors were 0.07 ± 0.19 mm (−18 ± 92 mg/cm{sup 3}) using the simulated clinical CT volumes with the smallest voxel size (0.33 × 0.33 × 0.5 mm{sup 3}), and 0.10 ± 0.24 mm (−10 ± 115 mg/cm{sup 3}) using the volumes with the largest voxel size (1.0 × 1.0 × 3.0 mm{sup 3}). A trend for the cortical thickness and density estimation errors to increase with voxel size was observed and was more pronounced for thin cortices. Using clinical CT data for 19 of the 23 samples, mean errors of 0.18 ± 0.24 mm for the cortical thickness and 15 ± 106 mg/cm{sup 3} for the density were found. The case-control study showed that osteoporotic patients had a thinner cortex and a lower cortical density, with average differences of −0.8 mm and −58.6 mg/cm{sup 3} at the proximal femur in comparison with age-matched controls (p-value < 0.001). Conclusions: This method might be a promising approach for the quantification of cortical bone thickness and density using clinical routine imaging techniques. Future work will concentrate on investigating how this approach can improve the estimation of mechanical strength of bony structures, the prevention of fracture, and the management of osteoporosis.

60 APPLIED LIFE SCIENCES↗

Format for Interchange and Display of 3D Terrain Data

Visible Scalable Terrain (ViSTa) is a software format for production, interchange, and display of three-dimensional (3D) terrain data acquired by stereoscopic cameras of robotic vision systems. ViSTa is designed to support scalability of data, accuracy of displayed terrain images, and optimal utilization of computational resources. In a ViSTa file, an area of terrain is represented, at one or more levels of detail, by coordinates of isolated points and/or vertices of triangles derived from a texture map that, in turn, is derived from original terrain images. Unlike prior terrain-image software formats, ViSTa includes provisions to ensure accuracy of texture coordinates. Whereas many such formats are based on 2.5-dimensional terrain models and impose additional regularity constraints on data, ViSTa is based on a 3D model without regularity constraints. Whereas many prior formats require external data for specifying image-data coordinate systems, ViSTa provides for the inclusion of coordinate-system data within data files. ViSTa admits highspeed loading and display within a Java program. ViSTa is designed to minimize file sizes and maximize compressibility and to support straightforward reduction of resolution to reduce file size for Internet-based distribution.

Backes, Paul↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular Distribution Models for Top-of-Atmosphere Radiative Flux Estimation from the Clouds and the Earth's Radiant Energy System Instrument on the Tropical Rainfall Measuring Mission Satellite: Methodology - Part 1

Clouds and the Earth s Radiant Energy System (CERES) investigates the critical role that clouds and aerosols play in modulating the radiative energy flow within the Earth-atmosphere system. CERES builds upon the foundation laid by previous missions, such as the Earth Radiation Budget Experiment, to provide highly accurate top-of-atmosphere (TOA) radiative fluxes together with coincident cloud and aerosol properties inferred from high-resolution imager measurements. This paper describes the method used to construct empirical angular distribution models (ADMs) for estimating shortwave, longwave, and window TOA radiative fluxes from CERES radiance measurements on board the Tropical Rainfall Measuring Mission satellite. To construct the ADMs, multiangle CERES measurements are combined with coincident high-resolution Visible Infrared Scanner measurements and meteorological parameters from the European Centre for Medium-Range Weather Forecasts data assimilation product. The ADMs are stratified by scene types defined by parameters that have a strong influence on the angular dependence of Earth's radiation field at the TOA. Examples of how the new CERES ADMs depend upon the imager-based parameters are provided together with comparisons with existing models.

Loeb, N. G.↗

A FIRST ESTIMATE OF RADIO HALO STATISTICS FROM LARGE-SCALE COSMOLOGICAL SIMULATION

We present a first estimate based on a cosmological gas dynamics simulation of galaxy cluster radio halo counts to be expected in forthcoming low-frequency radio surveys. Our estimate is based on a FLASH simulation of the {Lambda}CDM model for which we have assigned radio power to clusters via a model that relates radio emissivity to cluster magnetic field strength, intracluster turbulence, and density. We vary several free parameters of this model and find that radio halo number counts vary by up to a factor of two for average magnetic fields ranging from 0.2 to 3.1 {mu}G. However, we predict significantly fewer low-frequency radio halos than expected from previous semi-analytic estimates, although this discrepancy could be explained by frequency-dependent radio halo probabilities as predicted in reacceleration models. We find that upcoming surveys will have difficulty in distinguishing models because of large uncertainties and low number counts. Additionally, according to our modeling we find that expected number counts can be degenerate with both reacceleration and hadronic secondary models of cosmic-ray generation. We find that relations between radio power and mass and X-ray luminosity may be used to distinguish models, and by building mock radio sky maps we demonstrate that surveys such as LOFAR may have sufficient resolution and sensitivity to break this model degeneracy by imaging many individual clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Properties of the North and South Polar Layered Deposits

One of the many questions of Martian exploration is to uncover the history of Mars, through analysis of the polar layered deposits (PLD). Martian polar ice caps hold most of the exposed water ice on the surface of Mars and yet their history and physical processes involved in their formation are unclear. We will attempt to contribute to our knowledge of the composition and stratigraphy of the PLD. In this work we present the latest imaging data acquired by the Mars Odyssey THermal EMission Imaging System (THEMIS) [1] and place it into context of the Mars Global Surveyor (MGS) data. We have discussed the North Polar data in [5]. This work concentrates on data acquired over the South pole of Mars and compares properties of North and South PLD. We are primarily interested in properties of the layers in both ice caps : their continuity, morphology and stratigraphy. These questions can be addressed by THEMIS VIS color images, along with MOC high resolution data and MOLA Digital Elevation Models (DEM). We will investigate thermophysical properties of the layered deposits employing THEMIS IR images. Based on the data obtained by the orbiting spacecraft and described here, we will attempt to expose major directions for modeling and further understanding of the physical processes involved in the formation of the polar layered terrain

Ivanov, A. B.↗

TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

60 APPLIED LIFE SCIENCES↗