Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Sandia Simple Particle Tracking (Sandia SPT) v. 1.0

Sandia SPT is designed as software to accompany a book chapter being published a methods chapter which provides an introduction on how to label and track individual proteins. The Sandia Simple Particle Tracking code uses techniques common to the image processing community, where its value is that it facilitates implementing the methods described in the book chapter by providing the necessary open-source code. The code performs single particle spot detection (or segmentation and localization) followed by tracking (or connecting the detected particles into trajectories). The book chapter, which along with the headers in each file, constitutes the documentation for the code is: Anthony, S.M.; Carroll-Portillo, A.; Timlon, J.A., Dynamics and Interactions of Individual Proteins in the Membrane of Living Cells. In Anup K. Singh (Ed.) Single Cell Protein Analysis Methods in Molecular Biology. Springer

Anthony, StephenM.↗

Sandia Simple Particle Tracking (Sandia SPT) v. 1.0

Sandia SPT is designed as software to accompany a book chapter being published a methods chapter which provides an introduction on how to label and track individual proteins. The Sandia Simple Particle Tracking code uses techniques common to the image processing community, where its value is that it facilitates implementing the methods described in the book chapter by providing the necessary open-source code. The code performs single particle spot detection (or segmentation and localization) followed by tracking (or connecting the detected particles into trajectories). The book chapter, which along with the headers in each file, constitutes the documentation for the code is: Anthony, S.M.; Carroll-Portillo, A.; Timlon, J.A., Dynamics and Interactions of Individual Proteins in the Membrane of Living Cells. In Anup K. Singh (Ed.) Single Cell Protein Analysis Methods in Molecular Biology. Springer

Anthony, Stephen M.↗

Effects of signal diffusion on x-ray phase contrast images

We discuss the problem of signal diffusion among neighbouring pixels in x-ray phase contrast imaging (XPCi) specifically for coded-aperture (CA) XPCi, but many of the discussed observations are directly transferable to other XPCi modalities. CA XPCi exploits the principle of pixel edge illumination by means of two CA masks. The first mask, placed in contact with the detector, creates insensitive regions between adjacent pixels; the second one, placed immediately before the sample, creates individual beams impinging on the boundaries between sensitive and insensitive regions on the detector, as created by the detector mask. In this way, edge illumination is achieved for all pixels of an area detector illuminated by a divergent and polychromatic beam generated by a conventional source. As the detector mask redefines the resolution properties of the detector, sample dithering can be used to effectively increase the system spatial resolution, without having to apply any post-processing procedure (e.g., deconvolution). This however creates artifacts in the form of secondary fringes (which have nothing to do with phase-related secondary fringes) if there is signal diffusion between adjacent pixels. In non-dithered images, signal diffusion between adjacent pixels causes a reduction in image contrast. This effect is investigated both theoretically and experimentally, and its direct implications on image quality are discussed. The interplay with the sample positioning with respect to the detector pixel matrix, which also has an effect on the obtained image contrast, is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, September 2009

opics covered include: Filtering Water by Use of Ultrasonically Vibrated Nanotubes; Computer Code for Nanostructure Simulation; Functionalizing CNTs for Making Epoxy/CNT Composites; Improvements in Production of Single-Walled Carbon Nanotubes; Progress Toward Sequestering Carbon Nanotubes in PmPV; Two-Stage Variable Sample-Rate Conversion System; Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas; Board Saver for Use with Developmental FPGAs; Circuit for Driving Piezoelectric Transducers; Digital Synchronizer without Metastability; Compact, Low-Overhead, MIL-STD-1553B Controller; Parallel-Processing CMOS Circuitry for M-QAM and 8PSK TCM; Differential InP HEMT MMIC Amplifiers Embedded in Waveguides; Improved Aerogel Vacuum Thermal Insulation; Fluoroester Co-Solvents for Low-Temperature Li+ Cells; Using Volcanic Ash to Remove Dissolved Uranium and Lead; High-Efficiency Artificial Photosynthesis Using a Novel Alkaline Membrane Cell; Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays; Micro-Horn Arrays for Ultrasonic Impedance Matching; Improved Controller for a Three-Axis Piezoelectric Stage; Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water; Micro-Organ Devices; Nonlinear Thermal Compensators for WGM Resonators; Dynamic Self-Locking of an OEO Containing a VCSEL; Internal Water Vapor Photoacoustic Calibration; Mid-Infrared Reflectance Imaging of Thermal-Barrier Coatings; Improving the Visible and Infrared Contrast Ratio of Microshutter Arrays; Improved Scanners for Microscopic Hyperspectral Imaging; Rate-Compatible LDPC Codes with Linear Minimum Distance; PrimeSupplier Cross-Program Impact Analysis and Supplier Stability Indicator Simulation Model; Integrated Planning for Telepresence With Time Delays; Minimizing Input-to-Output Latency in Virtual Environment; Battery Cell Voltage Sensing and Balancing Using Addressable Transformers; Gaussian and Lognormal Models of Hurricane Gust Factors; Simulation of Attitude and Trajectory Dynamics and Control of Multiple Spacecraft; Integrated Modeling of Spacecraft Touch-and-Go Sampling; Spacecraft Station-Keeping Trajectory and Mission Design Tools; Efficient Model-Based Diagnosis Engine; and DSN Simulator.

Source record↗

Responsive Image Inline Filter

RIIF is a contributed module for the Drupal php web application framework (drupal.org). It is written as a helper or sub-module of other code which is part of version 8 "core Drupal" and is intended to extend its functionality. It allows Drupal to resize images uploaded through the user-facing text editor within the Drupal GUI (a.k.a. "inline images") for various browser widths. This resizing is already done foe other images through the parent "Responsive Image" core module. This code extends that functionality to inline images.

Freeman, Ian↗

Inspection design using 2D phased array, TFM and cueMAP software

A simulation suite, cueMAP, has been developed to facilitate the design of inspection processes and sparse 2D array configurations. At the core of cueMAP is a Total Focusing Method (TFM) imaging algorithm that enables computer assisted design of ultrasonic inspection scenarios, including the design of bespoke array configurations to match the inspection criteria. This in-house developed TFM code allows for interactive evaluation of image quality indicators of ultrasonic imaging performance when utilizing a 2D phased array working in FMC/TFM mode. The cueMAP software uses a series of TFM images to build a map of resolution, contrast and sensitivity of imaging performance of a simulated reflector, swept across the inspection volume. The software takes into account probe properties, wedge or water standoff, and effects of specimen curvature. In the validation process of this new software package, two 2D arrays have been evaluated on 304n stainless steel samples, typical of the primary circuit in nuclear plants. Thick section samples have been inspected using a 1MHz 2D matrix array. Due to the processing efficiency of the software, the data collected from these array configurations has been used to investigate the influence sub-aperture operation on inspection performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Foundation Models for Zero-Shot Segmentation of Scientific Images without AI-Ready Data

Zero-shot and prompt-based models have excelled at visual reasoning tasks by leveraging large-scale natural image corpora, but they often fail on sparse and domain-specific scientific image data. We introduce Zenesis, a no-code interactive computer vision platform designed to reduce data readiness bottlenecks in scientific imaging workflows. Zenesis integrates lightweight multimodal adaptation for zero-shot inference on raw scientific data, human-in-the-loop refinement, and heuristic-based temporal enhancement. We validate our approach on Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) datasets of catalyst-loaded membranes. Zenesis outperforms baselines, achieving an average accuracy of 0.947, Intersection over Union (IoU) of 0.858, and Dice score of 0.923 on amorphous catalyst samples; and 0.987 accuracy, 0.857 IoU, and 0.923 Dice on crystalline samples. These results represent a significant performance gain over conventional methods such as Otsu thresholding and standalone models like the Segment Anything Model (SAM). Zenesis enables effective image segmentation in domains where annotated datasets are limited, offering a scalable solution for scientific discovery.

Mukherjee, Shubhabrata↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

Awake Animal Imaging Motion Tracking Software

The Awake Animal Motion Tracking Software code calculates the 3D movement of the head motion of a live, awake animal during a medical imaging scan. In conjunction with markers attached to the head, images acquired from multiple cameras are processed and marker locations precisely determined. Using off-line camera calibration data, the 3D positions of the markers are calculated along with a 6 degree of freedom position and orientation (pose) relative to a fixed initial position. This calculation is performed in real time at frame rates up to 30 frames per second. A time stamp with microsecond accuracy from a time base source is attached to each pose measurement.

Goddard, James↗

A balloon-borne imaging gamma-ray telescope

A balloon-borne coded-aperture gamma-ray telescope for galactic and extragalactic astronomy observations is described. The instrument, called Gamma Ray Imaging Payload (GRIP), is designed for measurements in the energy range from 30 keV to 5 MeV with an angular resolution of 0.6 deg over a 20 deg field of view. Distinguishing characteristics of the telescope are a rotating hexagonal coded-aperture mask and a thick NaI scintillation camera. Rotating hexagonal coded-apertures and the development of thick scintillation cameras are discussed.

Althouse, W. E.↗

Retina Image Screening and Analysis Software Version 2.0

The software allows physicians or researchers to ground-truth images of retinas, identifying key physiological features and lesions that are indicative of disease. The software features methods to automatically detect the physiological features and lesions. The software contains code to measure the quality of images received from a telemedicine network; create and populate a database for a telemedicine network; review and report the diagnosis of a set of images; and also contains components to transmit images from a Zeiss camera to the network through SFTP.

Tobin, Jr., Kenneth W.↗

ALMA CONTINUUM OBSERVATIONS OF A 30 Myr OLD GASEOUS DEBRIS DISK AROUND HD 21997

Circumstellar disks around stars older than 10 Myr are expected to be gas-poor. There are, however, two examples of old (30-40 Myr) debris-like disks containing a detectable amount of cold CO gas. Here we present Atacama Large Millimeter/Submillimeter Array (ALMA) and Herschel Space Observatory observations of one of these disks, around HD 21997, and study the distribution and origin of the dust and its connection to the gas. Our ALMA continuum images at 886 μm clearly resolve a broad ring of emission within a diameter of ∼4.''5, adding HD 21997 to the dozen debris disks resolved at (sub)millimeter wavelengths. Modeling the morphology of the ALMA image with a radiative transfer code suggests inner and outer radii of ∼55 and ∼150 AU, and a dust mass of 0.09 M {sub ⊕}. Our data and modeling hints at an extended cold outskirt of the ring. Comparison with the morphology of the CO gas in the disk reveals an inner dust-free hole where gas nevertheless can be detected. Based on dust grain lifetimes, we propose that the dust content of this gaseous disk is of secondary origin and is produced by planetesimals. Since the gas component is probably primordial, HD 21997 is one of the first known examples of a hybrid circumstellar disk, a thus-far little studied late phase of circumstellar disk evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep reinforcement learning of cell movement in the early stage of C.elegans embryogenesis

Motivation: Cell movement in the early phase of Caenorhabditis elegans development is regulated by a highly complex process in which a set of rules and connections are formulated at distinct scales. Previous efforts have demonstrated that agent-based, multi-scale modeling systems can integrate physical and biological rules and provide new avenues to study developmental systems. However, the application of these systems to model cell movement is still challenging and requires a comprehensive understanding of regulatory networks at the right scales. Recent developments in deep learning and reinforcement learning provide an unprecedented opportunity to explore cell movement using 3D time-lapse microscopy images. Results: We present a deep reinforcement learning approach within an agent-based modeling system to characterize cell movement in the embryonic development of C.elegans. Our modeling system captures the complexity of cell movement patterns in the embryo and overcomes the local optimization problem encountered by traditional rule-based, agent-based modeling that uses greedy algorithms. Here, we tested our model with two real developmental processes: the anterior movement of the Cpaaa cell via intercalation and the rearrangement of the superficial left-right asymmetry. In the first case, the model results suggested that Cpaaa’s intercalation is an active directional cell movement caused by the continuous effects from a longer distance (farther than the length of two adjacent cells), as opposed to a passive movement caused by neighbor cell movements. In the second case, a leader-follower mechanism well explained the collective cell movement pattern in the asymmetry rearrangement. These results showed that our approach to introduce deep reinforcement learning into agent-based modeling can test regulatory mechanisms by exploring cell migration paths in a reverse engineering perspective. Lastly, this model opens new doors to explore the large datasets generated by live imaging. Availability and implementation: Source code is available at https://github.com/zwang84/drl4cellmovement.

59 BASIC BIOLOGICAL SCIENCES↗

Introducing SpaceNet 9 - Cross-Modal Satellite Imagery Registration for Natural Disaster Responses

Computer vision algorithms are increasingly leveraged to accelerate geospatial analysis for disaster response and recovery. As the diversity of remote sensing imagery grows with optical, SAR, and other modalities, a perquisite for analytics is cross-modal image registration. There is a high potential to harness computer vision for this pre-processing requirement toward enabling downstream analytics such as heterogeneous change detection, automated feature extraction, and data fusion. Advancement in these areas has the potential to simplify data wrangling tasks and further accelerate disaster response timelines. The SpaceNet 9 challenge (launching in mid-2024) focuses on addressing the cross-modal image registration problem and demonstrating the utility of such modules on earthquake impacted scenarios. This paper describes the motivation for the SpaceNet 9 and provides a first overview of the dataset, the baseline algorithm, and implications for seeking cross-modal image registration in Earth observation. Code is available at https://github.com/SpaceNetChallenge/SpaceNet9.

Hansch, Ronny↗

RM2: rms error comparisons

The root-mean-square error performance measure is used to compare the relative performance of several widely known source coding algorithms with the RM2 image data compression system. The results demonstrate that RM2 has a uniformly significant performance advantage.

Rice, R. F.↗

Development of a numerical procedure to map a general 3-d body onto a near-circle

Conformal mapping is a classical technique utilized for solving problems in aerodynamics and hydrodynamics. Conformal mapping is utilized in the construction of grids around airfoils, engine inlets and other aircraft configurations. These shapes are transformed onto a near-circle image for which the equations of fluid motion are discretized on the mapped plane and solved numerically by utilizing the appropriate techniques. In comparison to other grid-generation techniques such as algerbraic or differential type, conformal mapping offers an analytical and accurate form even if the grid deformation is large. One of the most appealing features is that the grid can be constrained to remain orthogonal to the body after the transformation. Hence, the grid is suitable for analyzing the supersonic flow past a blunt object. The associated shock as a coordinate surface adjusts its position in the course of computation until convergence is reached. The present work applied conformal mapping to 3-D bodies with no axis of symmetry such as the Aerobraking Flight Experiment (AFE) vehicle, transforming the AFE shape onto a near-circle image. A numerical procedure and code are used to generate grids around the AFE body.

Hommel, M. J.↗

Engineering Voyager 2's encounter with Uranus

Changes made by radio control from the ground in the Voyager 2 spacecraft as it approached Uranus are described. Reduced power required that subsystems and heaters had to be switched on and off in carefully synchronized fashion. Low light levels required increased exposure times, so the jiggling of the spacecraft had to be minimized. Coding changes were made and image data were compressed to cope with the reduced bit rate at larger distances. Successful efforts to cope with failures in the primary radio receiver and in the computer instructions for image compression are described, as are changes made on the ground in the spacecraft navigation.

Laeser, Richard P.↗