Search NASA⌕ Search

SEARCH · Search NASA

Results for “load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Comparison of Two Load Prediction Methods for Strain-Gage Balances

Data from a high-capacity semi-span balance is used to perform a detailed comparison of the load prediction accuracy of two strain-gage balance load prediction methods. Both methods independently obtain their load prediction equations from multivariate least squares fits of balance calibration data. The first method is called Non-Iterative Method. This approach directly uses regression models of the individual load components of a balance for the load prediction. The second method is called Iterative Method. This alternate approach uses a load iteration equation for the load prediction that is constructed from the regression models of the gage outputs of the balance. Basic characteristics of the two methods are reviewed. Afterwards, both methods are applied to calibration and check load data of the chosen balance. Finally, selected analysis results are compared. These comparisons confirmed that the load prediction accuracy of the two methods is the same for all practical purposes.

wind tunnel test↗

Dual strain gage balance system for measuring light loads

A dual strain gage balance system for measuring normal and axial forces and pitching moment of a metric airfoil model imparted by aerodynamic loads applied to the airfoil model during wind tunnel testing includes a pair of non-metric panels being rigidly connected to and extending towards each other from opposite sides of the wind tunnel, and a pair of strain gage balances, each connected to one of the non-metric panels and to one of the opposite ends of the metric airfoil model for mounting the metric airfoil model between the pair of non-metric panels. Each strain gage balance has a first measuring section for mounting a first strain gage bridge for measuring normal force and pitching moment and a second measuring section for mounting a second strain gage bridge for measuring axial force.

Roberts, Paul W.↗

Development of a dual strain gage balance system for measuring light loads

A strain-gage-balance (SGB) force-measurement system is described which was designed to meet light-load requirements for an airfoil model tested in the NASA Langley low-turbulence pressure tunnel (LTPT). This system was developed to obtain direct force data needed to verify calculated pressure/force correlations used in previous aerodynamic tests. The three-component force-measurement system was designed so that the SGBs would simultaneously support and measure the following loads: weight of the airfoil (approximately 3.0 lbf); 8.0 lbf of lift; 0.5 lbf of drag; and 16.0 in. lbf of pitching moment. In addition to these design loads, the system was required to withstand 100-percent overload on all three components. The system comprises an airfoil, two SGBs, a thermal flexure, and a mounting plate. The installation of the system in the LTPT is also discussed.

Roberts, Paul W.↗

An MILP-Based Distributed Energy Management for Coordination of Networked Microgrids

An MILP-based distributed energy management for the coordination of networked microgrids is proposed in this paper. Multiple microgrids and the utility grid are coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) update their schedules separately. Then, the price signals are updated according to the generation–load mismatch and distributed to MCs and DMS for the next iteration. The iteration continues until the generation–load mismatch is small enough, i.e., the generation and load are balanced under agreed price signals. Through the proposed distributed energy management, various microgrids and the utility grid with different economic, resilient, emission and socio-economic objectives are coordinated with generation–load balance guaranteed and the microgrid customers’ privacy preserved. In particular, a piecewise linearization technique is employed to approximate the augmented Lagrange term in the alternating direction method of multipliers (ADMM) algorithm. Thus, the subproblems are transformed into mixed integer linear programming (MILP) problems and efficiently solved by open-source MILP solvers, which would accelerate the adoption and deployment of microgrids and promote clean energy. The proposed MILP-based distributed energy management is demonstrated through various case studies on a networked microgrids test system with three microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation, Analysis, and Application of Internal Strain-Gage Balance Data

Experimental processes, analytical methods, and numerical algorithms are described that may be used to predict the forces and moments of an internal strain–gage balance during a wind tunnel test. First, the control volume model of a strain–gage balance and the concepts of load state, load space, and output space are introduced. These important abstractions provide a better understanding of fundamental characteristics of different balance load prediction approaches. Then, the description of strain–gage balance data and the definition of the primary bridge sensitivity are discussed. Afterwards, basic elements of the calibration of a typical six–component balance are reviewed. Two fundamentally different balance load prediction methods, the processing of check loads, and related topics are also discussed. Three real–world balance data examples are reviewed in great detail to illustrate typical analysis results for a variety of strain–gage balance designs. Finally, important observations are summarized and recommendations are provided. – Additional information and detailed mathematical derivations can be found in the appendices of the document. They include the following topics: balance terminology, definitions of important statistical metrics, balance axis system conventions, balance load transformations, the combined load diagram, electrical output format options, bi–directional output characteristics, determination of the natural zeros, derivation of two balance load prediction methods, description of two tare load iteration algorithms, modeling of balance temperature effects, basics of three–component moment balances, definition of the percent contribution, detection of linear and near–linear dependencies in balance calibration data, a regression model search algorithm, balance interactions, and other related information.

strain-gage balance↗

Flight Measurements of Horizontal-Tail Loads on the Bell X-5 Research Airplane at a Sweep Angle of 58.7 Deg

A flight investigation was made at altitudes of 40,000, 25,000 and 15,000 feet to determine the horizontal-tail loads of the Bell X-5 research airplane at a sweep angle of 58.7 deg over the lift range of the airplane for Mach numbers from 0.61 to 1.00. The horizontal-tail loads were found to be nonlinear with lift throughout the lift ranges tested at all Mach numbers except at a Mach number of 1.00. The balancing tail loads reflected the changes which occur in the wing characteristics with increasing angle of attack. The nonlinearities were, in general, more pronounced at the higher angles of attack near the pitch-up where the balancing tail loads indicate that the wing-fuselage combination becomes unstable. No apparent effects of altitude on the balancing tail loads were evident over the comparable lift ranges of these tests at altitudes from 40,000 feet to 15,000 feet. Comparisons of balancing tail loads obtained from flight and windtunnel tests indicated discrepancies in absolute magnitudes, but the general trends of the data agree. Some differences in absolute magnitude may be accounted for by the tail load carried inboard of the strain-gage station and the load induced on the fuselage by the presence of the tail. These loads were not measured in flight.

Reed, Robert D↗

Evaluation, Analysis, and Application of Internal Strain-Gage Balance Data

Experimental processes, analytical methods, and numerical algorithms are described that may be used to predict the forces and moments of an internal strain-gage balance during a wind tunnel test. First, the control volume model of a strain-gage balance and the concepts of load state, load space, and output space are introduced. These important abstractions provide a better understanding of fundamental characteristics of different balance load prediction approaches. Then, the description of strain-gage balance data and the definition of the primary gage sensitivity is discussed. Afterwards, basic elements of the calibration of a typical six-component balance are reviewed. Two fundamentally different balance load prediction methods, the processing of check loads, and related topics are also discussed. Three real-world balance data examples are reviewed in great detail to illustrate typical analysis results for a variety of strain-gage balance designs. Finally, important observations are summarized and recommendations are provided. Additional information and detailed mathematical derivations can be found in the appendices of the document. They include the following topics: balance terminology, definitions of important statistical metrics, balance axis system conventions, balance load transformations, the combined load diagram, electrical output format options, bi-directional gage output characteristics, determination of the natural zeros, derivation of two balance load prediction methods, description of two tare load iteration algorithms, modeling of balance temperature effects, basics of three-component moment balances, definition of the percent contribution, detection of linear and near-linear dependencies in balance calibration data, a regression model term selection algorithm, and other related topics.

wind tunnel test↗

Application of the Concepts of Load State, Load Space, and Output Space to Strain-Gage Balances

The concepts of load state, load space, and output space are used to describe elements of the development of a load prediction process for a six–component strain–gage balance. The use of these terms adds clarity during the selection of the independent and dependent variables for the development of the load prediction process. First, the control volume model of a strain–gage balance is reviewed as it helps better understand the role of loads, outputs, and state variables during the load prediction. Then, the description of the absolute load datum in both the load space and the output space is discussed. It is concluded that the use of the difference between a raw output and the natural zero of a balance gage has a key advantage for the definition of the output space. In that case, the origin of the output space will also describe the absolute load datum of the balance. Finally, details of the application of the concepts of load state, load space, and output space to two commonly used balance load prediction methods are discussed.

strain-gage balance↗

SSME alternate turbopump (pump section) axial load analysis

A flow balancing computer program constructed to calculate the axial loads on the Space Shuttle Main Engine (SSME) alternate turbopumps (ATs) pump sections are described. The loads are used in turn to determine load balancing piston design requirements. The application of the program to the inlet section, inducer/impeller/stage, bearings, seals, labyrinth, damper, piston, face and corner, and stationary/rotating surfaces is indicated. Design analysis results are reported which show that the balancing piston's designs are adequate and that performance and life will not be degraded by the turbopump's axial load characteristics.

Crease, G. A.↗

Self-balancing beam permits safe, easy load handling under overhang

The use of a self-balancing I-beam with a counterweight and motor simplifies moving heavy loads that are inaccessible for cranes. The beam cannot be overloaded, as the counterweight will not balance the load, and thus acts as an automatic safety device.

Edwards, O. H.↗

Analysis of Sting Balance Calibration Data Using Optimized Regression Models

Calibration data of a wind tunnel sting balance was processed using a search algorithm that identifies an optimized regression model for the data analysis. The selected sting balance had two moment gages that were mounted forward and aft of the balance moment center. The difference and the sum of the two gage outputs were fitted in the least squares sense using the normal force and the pitching moment at the balance moment center as independent variables. The regression model search algorithm predicted that the difference of the gage outputs should be modeled using the intercept and the normal force. The sum of the two gage outputs, on the other hand, should be modeled using the intercept, the pitching moment, and the square of the pitching moment. Equations of the deflection of a cantilever beam are used to show that the search algorithm s two recommended math models can also be obtained after performing a rigorous theoretical analysis of the deflection of the sting balance under load. The analysis of the sting balance calibration data set is a rare example of a situation when regression models of balance calibration data can directly be derived from first principles of physics and engineering. In addition, it is interesting to see that the search algorithm recommended the same regression models for the data analysis using only a set of statistical quality metrics.

Ulbrich, Norbert↗

Monitoring dynamic loads on wind tunnel force balances

Two devices have been developed at NASA Langley to monitor the dynamic loads incurred during wind-tunnel testing. The Balance Dynamic Display Unit (BDDU), displays and monitors the combined static and dynamic forces and moments in the orthogonal axes. The Balance Critical Point Analyzer scales and sums each normalized signal from the BDDU to obtain combined dynamic and static signals that represent the dynamic loads at predefined high-stress points. The display of each instrument is a multiplex of six analog signals in a way that each channel is displayed sequentially as one-sixth of the horizontal axis on a single oscilloscope trace. Thus this display format permits the operator to quickly and easily monitor the combined static and dynamic level of up to six channels at the same time.

Ferris, Alice T.↗

Recovery act: development of design and simulation tool for hybrid geothermal heat pump system

The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7[1]. The simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the undersized well field.

15 GEOTHERMAL ENERGY↗

Comparative study of control strategies for hybrid GSHP system in the cooling dominated climate

The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7 [1]. In the end, the simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the reduced size well field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Human-in-the-Loop Evaluation of Multi-Sector Planning in Mixed Equipage Airspace (MSP III)

A human-in-the-loop (HITL) simulation was conducted in May 2010 to determine the feasibility and value 01 conducting multi-sector planning (MSP) operations in a mixed equipage environment. Aircraft were categorized as equipped or unequipped based on the presence or absence of an air-ground data communications (Data Comm) capability for receiving auto-loadable clearances and transfer of communication messages from the air navigation service provider (ANSP). The purpose of the study was to determine the feasibility and possible benefits of introducing multi-sector planning in a mixed equipage context, or whether Data Comm equipage was required for MSP operations. Each test scenario presented one of three different equipage levels to the controllers (10%, 50% or 90% equipped aircraft), so that the operational impact of different equipage levels could be observed. Operational feasibility assessment addressed two related questions: (1) are MSP operations feasible for unequipped aircraft, and (2) are they feasible in a mixed equipage context. Similarly, two categories of potential benefits were explored: (1) system performance improvements (e.g., throughput, workload) associated with MSP at different equipage levels, and (2) the possibility of providing differential service for equipage through MSP operations. Tool requirements (for both planning and controller stations), as well as planning and coordination procedures - within facility (traffic management unit/operational area) and within sector (R-Side/D-Side) - were two other topics addressed in the study. Overall, results suggested that MSP operations were feasible in a mixed equipage environment and that the tools were effective with both equipped and unequipped aircraft. Using the MSP tools, traffic management coordinators were able to manage controller task load, effectively balancing throughput with complexity and controller task load at each of the three equipage levels tested.

Smith, Nancy↗

Balancing Power Absorption Against Structural Loads With Viscous Drag and Power-Takeoff Efficiency Considerations

The focus of this paper is to balance power absorption against structural loading for a novel fixed-bottom oscillating surge wave energy converter in both regular and irregular wave environments. The power-to-load ratio will be evaluated using pseudospectral control (PSC) to determine the optimum power-takeoff (PTO) torque based on a multiterm objective function. This paper extends the pseudospectral optimal control problem to not just maximize the time-averaged absorbed power but also include measures for the surge-foundation force and PTO torque in the optimization. The objective function may now potentially include three competing terms that the optimizer must balance. Separate weighting factors are attached to the surge-foundation force and PTO control torque that can be used to tune the optimizer performance to emphasize either power absorption or load shedding. To correct the pitch equation of motion, derived from linear hydrodynamic theory, a quadratic-viscous-drag torque has been included in the system dynamics; however, to continue the use of quadratic programming solvers, an iteratively obtained linearized drag coefficient was utilized that provided good accuracy in the predicted pitch motion. Furthermore, the analysis considers the use of a nonideal PTO unit to more accurately evaluate controller performance. The PTO efficiency is not directly included in the objective function but rather the weighting factors are utilized to limit the PTO torque amplitudes, thereby reducing the losses resulting from the bidirectional energy flow through a nonideal PTO. Furthermore, results from PSC show that shedding a portion of the available wave energy can lead to greater reductions in structural loads, peak-to-average power ratio, and reactive power requirement.

16 TIDAL AND WAVE POWER↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

14 SOLAR ENERGY↗