Search NASA⌕ Search

SEARCH · Search NASA

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Ecological optimality in water-limited natural soil-vegetation systems. II - Tests and applications

The long-term optimal climatic climax soil-vegetation system is defined for several climates according to previous hypotheses in terms of two free parameters, effective porosity and plant water use coefficient. The free parameters are chosen by matching the predicted and observed average annual water yield. The resulting climax soil and vegetation properties are tested by comparison with independent observations of canopy density and average annual surface runoff. The climax properties are shown also to satisfy a previous hypothesis for short-term optimization of canopy density and water use coefficient. Using these hypotheses, a relationship between average evapotranspiration and optimum vegetation canopy density is derived and is compared with additional field observations. An algorithm is suggested by which the climax soil and vegetation properties can be calculated given only the climate parameters and the soil effective porosity. Sensitivity of the climax properties to the effective porosity is explored.

Eagleson, P. S.↗

JT9D jet engine diagnostics program

Performance deterioration in the JT9D-7 is a flight sensitive phenomenon caused by one short term and two long term wear modes. The short term deterioration occurs primarily during airplane acceptance testing and therefore does not affect airline operation. The long term wear takes place continuously over the engine life so that the performance loss can be minimized by a sound maintenance program. Short term deterioration is primarily due to flight load induced blade and gas path seal wear which result in increased gas path running clearances. The wear occurs in all engine modules but has the most deleterious effect on the low pressure compressor and high pressure turbine performance. The wear occurs during conditions that combine minimum axisymmetric running clearances and maximum engine distortion or asymmetric closure.

Olsson, W. J.↗

Stability of a Ni/NiF 2 Reference Electrode with a Metallic Membrane for Use in Molten Fluoride Salts

In this study, an experimental high-temperature fluoride salt reference electrode (RE) developed by HiFunda LLC was tested in molten FLiNaK at 550 °C. The high-temperature reference electrode (HTRE), based on the Ni/NiF 2 redox couple, was tested over a period of 13 d for short-term stability, long-term stability, and electrochemical analysis capabilities. The HTRE was tested using open circuit potentiometry (OCP), cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS). The HTRE reference potential was measured against changes in salt composition by increasing FeF 2 concentrations in the melt across six additions from 0 to 0.1 mol% FeF 2 . The long-term stability of the electrode was then tested over ten days at a constant composition of 0.1 mol% FeF 2 . OCP, SWV, and CV were used to calculate an average potential drift between 7–10 mV per day. Using CV and SWV, the number of electrons transferred for iron reduction and the diffusion coefficient of Fe 2+ were measured.

Electrochemistry↗

COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies

Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.

Brusse, Jay A.↗

Port scanner and Testing Suite

This project addresses the challenge of identifying and managing open network ports across physical and virtual hosts. The current form of verifying ports in use required manually searching individual ports - a process that was both time- consuming and a potential bottleneck for deployment timelines. To resolve this, an automated port scanning tool was developed in Python. The tool supports simultaneous multiple port scans. To ensure functionality and long-term maintainability, a comprehensive testing suite was implemented using Python’s unittest framework. Edge cases, including valid port numbers, reversed ranges, and closed ports, were explicitly tested to ensure robust handling of real-world scenarios. The resulting tool reduces the time required to verify port security across a network, supporting both targeted and host checks and broader Classless Inter-Domain Routing (CIDR) -based network scans. This work demonstrates the value of automation and test-driven development in strengthening network security practices, and provides a foundation for future enhancements.

Rivera, Linda [Fermilab]↗

Thermal Cycling and High Temperature Reverse Bias Testing of Control and Irradiated Gallium Nitride Power Transistors

The power systems for use in NASA space missions must work reliably under harsh conditions including radiation, thermal cycling, and exposure to extreme temperatures. Gallium nitride semiconductors show great promise, but information pertaining to their performance is scarce. Gallium nitride N-channel enhancement-mode field effect transistors made by EPC Corporation in a 2nd generation of manufacturing were exposed to radiation followed by long-term thermal cycling and testing under high temperature reverse bias conditions in order to address their reliability for use in space missions. Result of the experimental work are presented and discussed.

thermal cycling tests↗

Polymer Additive Manufacturing for Marine Renewable Energy Applications: Best Practices, Research Trends, and Current Challenges

Additive manufacturing (AM) is a rapidly growing technology space, not only for prototyping, but is also becoming more feasible at larger scales and increasing component quantities. There are a large variety of AM processes and materials available to users and effectively applying those processes and materials to a specific use case can be challenging. One specific area where AM could be particularly beneficial is marine renewable energy (MRE). Not only is MRE a relatively nascent industry with a near-term need for rapid deployments and prototype testing, but developers could also see long-term benefits from the broad variety of environmentally resistant materials available and the ability to manufacture complex geometries that AM technologies offer. Over the past 4 years, AM materials have played an increasing role in the Advanced Materials project; a multi-year, multi-laboratory research project funded by the U.S. Department of Energy's Water Power Technologies Office, with the main goal of reducing barriers to the adoption of complex materials in the MRE industry. The primary focus of this project is to develop test methods and generate datasets to understand the long-term performance of advanced materials in marine environmental and address specific material challenges as they arise. This report provides an extensive overview of the research that has been performed specific to AM polymers as part of the Advanced Materials project. The intention of this document is to provide recommendations of best practices with regards to material selection, mechanical test method development, and design practices, lessons learned along the way, current research trends, and ongoing challenges with regards to AM polymers in marine environments. In particular, this report focuses on several key aspects: Material and process selection, Environmental conditioning and subsequent degradation quantification through mechanical characterization, Composite reinforcements on AM polymer substrates, Adhesion of instrumentation for mechanical characterization and loads measurements, Protective coatings for preventing biofouling and water ingress, Other MRE case studies where AM has proved particularly useful. Ultimately, we hope that the test methods that have been developed, data generated, and lessons learned from this research will be valuable to the MRE community (researchers and developers alike), as well as other industries, and can be used as a reference point as the respective MRE and AM industries continue to grow and mature.

16 TIDAL AND WAVE POWER↗

Particle Streak Velocimetry of Supersonic Nozzle Flows

A novel velocimetry technique to probe the exhaust flow of a laboratory scale combustor is being developed. The technique combines the advantages of standard particle velocimetry techniques and the ultra-fast imaging capabilities of a streak camera to probe high speed flows near continuously with improved spatial and velocity resolution. This "Particle Streak Velocimetry" technique tracks laser illuminated seed particles at up to 236 picosecond temporal resolution allowing time-resolved measurement of one-dimensional flows exceeding 2000 m/s as are found in rocket nozzles and many other applications. Developmental tests with cold nitrogen have been performed to validate and troubleshoot the technique with supersonic flows of much lower velocity and without background noise due to combusting flow. Flow velocities on the order of 500 m/s have been probed with titanium dioxide particles and a continuous-wave laser diode. Single frame images containing multiple streaks are analyzed to find the average slope of all incident particles corresponding to the centerline axial flow velocity. Long term objectives for these tests are correlation of specific impulse to theoretical combustion predictions and direct comparisons between candidate green fuels and the industry standard, monomethylhydrazine, each tested under identical conditions.

Willits, J. D.↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 . The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric transducer and two magnetostrictive transducers have demonstrated reliable operation under irradiation. The irradiation is ongoing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Aging Degradation Mechanisms of Alloy 709 for Sodium Fast Reactors

This project was initiated in October 2015 to investigate the creep and creep-fatigue behavior of Alloy 709 for structural components in Gen IV sodium cooled fast spectrum reactors. The goal of this project is to develop an understanding of the mechanisms responsible for the behavior of austenitic stainless steel alloy 709 under accelerated testing conditions to confidently predict long term creep and creep-fatigue behavior at the times (500,000 hours) and temperatures (550°C) of interest for fast reactor structural applications. Alloy 709 has exhibited significantly better creep resistance than Alloy 316H, which is currently specified in design of fast reactor structural components. However, the alloy has not been code qualified for elevated temperature nuclear design. The elevated temperature microstructure stability and creep and creep-fatigue behavior need to be better understood so service life can be accurately predicted. Alloy 709 was developed for fossil boiler applications, which operate at a higher temperature than the nuclear components. Thus, there is a strong need to characterize its creep and creep-fatigue behavior at these lower temperatures and corresponding longer service lifetimes. The overall objective of this project is to develop sufficient understanding of the mechanisms responsible for behavior of Alloy 709 under accelerated testing conditions to confidently predict long term creep and creep-fatigue behavior at the times (500,000 hours) and temperatures (550°C) of interest for fast reactor structural applications. The following report summarizes the findings of the creep-fatigue and creep behavior with respect to the research questions identified during the course of the project. Additionally, the training and professional development that occurred through the project and the products resulting from the project are summarized.

36 MATERIALS SCIENCE↗

Multi-Column Experimental Test Bed Using CaSDB MOF for Xe/Kr Separation

Processing of spent nuclear fuel produces off-gas from which several volatile radioactive components must be separated for further treatment or storage. As part of the Off-gas Sigma Team, parallel research at INL and PNNL has produced several promising sorbents for the selective capture of xenon and krypton from these off-gas streams. In order to design full-scale treatment systems, sorbents that are promising on a laboratory scale must be proven under process conditions to be considered for pilot and then full-scale use. To that end, a bench-scale multi-column system with capability to test multiple sorbents was designed and constructed at INL. This report details bench-scale testing of CaSDB MOF, produced at PNNL, and compares the results to those reported last year using INL engineered sorbents. Two multi-column tests were performed with the CaSDB MOF installed in the first column, followed with HZ-PAN installed in the second column. The CaSDB MOF column was placed in a Stirling cryocooler while the cryostat was employed for the HZ-PAN column. Test temperatures of 253 K and 191 K were selected for the first column while the second column was held at 191 K for both tests. Calibrated volume sample bombs were utilized for gas stream analyses. At the conclusion of each test, samples were collected from each column and analyzed for gas composition. While CaSDB MOF does appear to have good capacity for Xe, the short time to initial breakthrough would make design of a continuous adsorption/desorption cycle difficult, requiring either very large columns or a large number of smaller columns. Because of the tenacity with which Xe and Kr adhere to the material once adsorbed, this CaSDB MOF may be more suitable for use as a long-term storage solution. Further testing is recommended to determine if CaSDB MOF is suitable for this purpose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combined Silicon and Gallium Arsenide Solar Cell UV Testing

The near and long-term effect of UV on silicon solar cells is relatively understood. In an effort to learn more about the effects of UV radiation on the performance of GaAs/Ge solar cells, silicon and gallium arsenide on germanium (GaAs/Ge) solar cells were placed in a vacuum chamber and irradiated with ultraviolet light by a Spectrolab XT 10 solar simulator. Seventeen GaAs/Ge and 8 silicon solar cells were mounted on an 8 inch copper block. By having all the cells on the same test plate we were able to do direct comparison of silicon and GaAs/Ge solar cell degradation. The test article was attached to a cold plate in the vacuum chamber to maintain the cells at 25 degrees Celsius. A silicon solar cell standard was used to measure beam uniformity and any degradation of the ST-10 beam. The solar cell coverings tested included cells with AR-0213 coverglass, fused silica coverglass, BRR-0213 coverglass and cells without coverglass. Of interest in the test is the BRR-0213 coverglass material manufactured by OCLI. It has an added Infrared rejection coating to help reduce the solar cell operating temperature. This coverglass is relatively new and of interest to several current and future programs at Marshall. Due to moves of the laboratory equipment and location only 350 hours of UV degradation have been completed. During this testing a significant leveling off in the rate of degradation was reached. Data from the test and comparisons of the UV effect of the bare cells and cells with coverglass material will be presented.

Willowby, Douglas↗

Space Debris Symposium (A6.) Measurements and Space Surveillance (1.): Measurements of the Small Particle Debris Cloud from the 11 January, 2007 Chinese Anti-satellite Test

On January 11, 2007, the Chinese military conducted a test of an anti-satellite (ASAT) system, destroying their own Fengyun-1C spacecraft with an interceptor missile. The resulting hypervelocity collision created an unprecedented number of tracked debris - more than 2500 objects. These objects represent only those large enough for the US Space Surveillance Network (SSN) to track - typically objects larger than about 5-10 cm in diameter. There are expected to be even more debris objects at sizes too small to be seen and tracked by the SSN. Because of the altitude of the target satellite (865 x 845 km orbit), many of the debris are expected to have long orbital lifetimes and contribute to the orbital debris environment for decades to come. In the days and weeks following the ASAT test, NASA was able to use Lincoln Laboratory s Haystack radar on several occasions to observe portions of the ASAT debris cloud. Haystack has the capability of detecting objects down to less than one centimeter in diameter, and a large number of centimeter-sized particles corresponding to the ASAT cloud were clearly seen in the data. While Haystack cannot track these objects, the statistical sampling procedures NASA uses can give an accurate statistical picture of the characteristics of the debris from a breakup event. For years computer models based on data from ground hypervelocity collision tests (e.g., the SOCIT test) and orbital collision experiments (e.g., the P-78 and Delta-180 on-orbit collisions) have been used to predict the extent and characteristics of such hypervelocity collision debris clouds, but until now there have not been good ways to verify these models in the centimeter size regime. It is believed that unplanned collisions of objects in space similar to ASAT tests will drive the long-term future evolution of the debris environment in near-Earth space. Therefore, the Chinese ASAT test provides an excellent opportunity to test the models used to predict the future debris environment. For this study, Haystack detection events are compared to model predictions to test the model assumptions, including debris size distribution, velocity distribution, and assumptions about momentum transfer between the target and interceptor. In this paper we will present the results of these and other measurements on the size and extent of collisional breakup debris clouds.

Matney, Mark J.↗

Drying Simulated Advanced Gas Reactor Fuel: Proving the Concept - 17637

Spent Nuclear Fuel (SNF) reprocessing is due to cease in the UK in 2018 and a new interim storage method may be required if it is found that pond storage is not viable beyond the 25 year period which is currently understood to be safe. Dry storage has been used elsewhere in the world for zircaloy and aluminium clad fuel and has been proposed for use in the UK, however since the UK's fuel is predominantly stainless steel (SS) clad, testing will need to be carried out to ensure that drying methods are suitable. This will require representative samples for macro scale drying tests. To date, little long term stored fuel has been examined. As a result, work has been carried out to try and ascertain whether the corrosion associated with long term storage leads to significant bound water and whether through wall cracks can be formed in intact lengths of SS tube. It was found that unlike an aluminium simulant, corroded SS showed no sign of water loss as a result of oxide dehydration during controlled drying by thermogravimetric analysis, and consequently bound water could be disregarded. It was also found that through wall cracks could be produced in an intact length of SS tube which would be suitable for macro scale drying tests. Some initial macro scale drying tests have been carried out using an alternative test piece with preformed cracks, and three distinct drying regimes to complete dryness have been detected. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Uncertainty Analysis to Guide the Development of Accelerated Stress Tests (Presentation)

Extrapolation of accelerated testing to the long-term results expected in the field has uncertainty associated with the acceleration factors and the range of possible stresses in the field. When multiple stresses (such as temperature and humidity) can be used to increase the acceleration, the uncertainty may be reduced according to which stress factors are used to accelerate the degradation.

14 SOLAR ENERGY↗

Rectal Dose-Volume Histogram Parameters Are Associated With Long-Term Patient-Reported Gastrointestinal Quality of Life After Conventional and High-Dose Radiation for Prostate Cancer: A Subgroup Analysis of a Randomized Trial

Purpose: We examined whether rectal dose-volume histogram (DVH) parameters were associated with long-term patient-reported gastrointestinal (GI) quality of life (QOL) after conventional (70.2 GyE) or high-dose (79.2 GyE) radiation for prostate cancer. Methods and Materials: Of 64 men with localized prostate cancer alive with a minimum 7-year follow-up after treatment as part of a randomized trial with either 70.2 GyE or 79.2 GyE of external beam radiation at Massachusetts General Hospital, 56 men (88%) returned a QOL questionnaire, and 50 of those men had DVH information. The DVH parameters of the anterior rectal wall were correlated with patient-reported long-term GI QOL using Pearson correlation and t tests. Results: There was a trend toward an association between increased long-term GI dysfunction and higher V60 (p = 0.07), V65 (p = 0.06), V70 (p = 0.09), and V75 (p = 0.09). When dichotomized by their medians, a V60 > 54% (p = 0.04), V70 > 44% (p = 0.06), and V75 > 39% (p = 0.06) were associated with increased long-term GI dysfunction. There was no difference in long-term GI dysfunction between men on the conventional vs. high-dose arms (p = 0.49). Conclusions: Dose-volume histogram parameters of the anterior rectal wall were associated with long-term patient-reported GI QOL after prostate radiation, whereas the dose prescribed to the prostate was not, suggesting that DVH constraints, rather than total prescribed dose, may have the greatest impact on long-term bowel dysfunction, and therefore that continued dose escalation may be feasible if appropriate dose-volume constraints are met.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overview of the 6 Meter HIAD Inflatable Structure and Flexible TPS Static Load Test Series

To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). At the beginning of 2014, a 6m HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify the designs structural performance. The 6m HIAD structure was constructed in a stacked toroid configuration using nine inflatable torus segments composed of fiber reinforced thin films, which were joined together using adhesives and high strength textile woven structural straps to help distribute the loads throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for displacement of the inflatable structure as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The centerbody of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to provide many data sets including: deformed shape, shoulder deflection, strap loads, cord loads, inflation pressures, and applied static load.In this overview, the 6m HIAD static load test series will be discussed in detail, including the 6m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally initial results and conclusions from the test series.

inflatable aerodynamic decelerator↗

Overview of the 6m HIAD Inflatable Structure and Flexible TPS Static Load Test Series

To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). At the beginning of 2014, a 6m HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify the designs structural performace. The 6m HIAD structure was constructed in a stacked toroid configuration using nine inflatable torus segments composed of fiber reinforced thin films, which were joined together using adhesives and high strength textile woven structural straps to help distribute the loads throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for displacement of the inflatable structure as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The centerbody of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to provide many data sets including: deformed shape, shoulder deflection, strap loads, cord loads, inflation pressures, and applied static load.In this overview, the 6m HIAD static load test series will be discussed in detail, including the 6m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally initial results and conclusions from the test series.

TPS↗