Flow and Heat Transfer Tests in New Loop at 2757 kPa (400 psi)

A helium flow and heat transfer experiment has been designed for the new helium flow loop facility at LANL. This new facility is centered on an Aerzen GM 12.4 Root’s blower, selected for operation at higher pressure, up to 2757 kPa, and mass flow rate, up to 400 g/s. This replaces the previous Tuthill PD plus 3206 blower and loop limited to 2067 kPa (300 psi) and 100 g/s. The resistively heated test piece is comprised of 7 electric heaters with embedded thermocouples. The plant design for the Mo100 to Mo99 targets requires sharp bends and geometry changes in the helium flow tube immediately before and after the target. An idealized fully developed flow configuration with straight entry and exit will be tested and compared with an option that employs rectangular tubing to make the bend at a radius consistent with and practical for the actual plant design. The current plant design, with circular tubing and a sudden contraction to rectangular just prior to target entrance, will also be tested. This requires some modification of the test piece, as described in the report.

42 ENGINEERING↗

Testing of a Loop Heat Pipe Subjected to Variable Accelerating Forces

This paper presents viewgraphs of the functionality of a loop heat pipe that was subjected to variable accelerating forces. The topics include: 1) Summary of LHP (Loop Heat Pipe) Design Parameters; 2) Picture of the LHP; 3) Schematic of Test Setup; 4) Test Configurations; 5) Test Profiles; 6) Overview of Test Results; 7) Start-up; 8) Typical Start-up without Temperature Overshoot; 9) Start-up with a Large Temperature Overshoot; 10) LHP Operation Under Stationary Condition; 11) LHP Operation Under Continuous Acceleration; 12) LHP Operation Under Periodic Acceleration; 13) Effects of Acceleration on Temperature Oscillation and Hysteresis; 14) Temperature Oscillation/Hysteresis vs Spin Rate; and 15) Summary.

Ku, Jentung↗

Dyno-in-the-Loop: An Innovative Hardware-in-the-Loop Development and Testing Platform for Emerging Mobility Technologies

Today’s transportation is quickly transforming with the nascent advent of connectivity, automation, shared-mobility, and electrification. These technologies will not only affect our safety and mobility, but also our energy consumption, and environment. As a result, it is of unprecedented importance to understand the overall system impacts due to the introduction of these emerging technologies and concepts. Existing modeling tools are not able to effectively capture the implications of these technologies, not to mention accurately and reliably evaluating their effectiveness with a reasonable scope. To address these gaps, a dynamometer-in-the-loop (DiL) development and testing approach is proposed which integrates test vehicle(s), chassis dynamometer, and high fidelity traffic simulation tools, in order to achieve a balance between the model accuracy and scalability of environmental analysis for the next generation of transportation systems. With this DiL platform, a connected eco-operation system for the plug-in hybrid electric bus (PHEB) has been developed and tested, which can optimize the vehicle dynamics (and potentially powertrain control via smart energy management) to reduce the operational energy consumption as well as tailpipe emissions of the target PHEB. The system performance has been evaluated on the DiL platform with respect to a variety of traffic congestion levels. The results have shown that the developed system can save fuel by more than 13% while reducing the electricity consumption by 2% in the test scenarios.

Wu, Guoyuan↗

Functional and performance tests of two capillary pumped loop engineering models

This paper presents the results of the functional and performance tests for two capillary pumped loop (CPL) engineering models. Both CPL systems are aluminum/ammonia transport systems which contain eight parallel evaporators and six parallel condensers in a single loop. Tests conducted include the transport limit, heat load shearing between evaporators, liquid inventory/temperature control by the reservoir, pressure priming under heat load, diode function of condensers, and isolation of a single deprimed evaporator. Consistent performance results were obtained for both systems. Transport capabilities of up to 70 kw-m with individual evaporators managing up to 1.7 kw, with a corresponding input heat flux of 15w/sq cm, were demonstrated. These tests demonstrated the ability of a CPL system to operate over a wide range of conditions and thus established the viability of these systems for high power thermal management of large spacecraft, such as the NASA Space Station.

Ku, J.↗

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe↗

Testing and Simulation of an Updated Cartridge Loop Vehicle

The Versatile Test Reactor (VTR) is a sodium-cooled, fast-spectrum test reactor that is being developed in the United States and will support a variety of irradiation test vehicle configurations, including cartridge loops. This work includes out-of-pile experimental results from a single-phase, natural circulation cartridge loop vehicle with geometry relevant to VTR irradiation sites, as well as comparisons between the experimental results and results predicted using the TRAC/RELAP Advanced Computational Engine (TRACE) modeling tool. The experiments were conducted in the thermosyphon test loop (TSTL) facility at Oak Ridge National Laboratory. Comparisons are also made between the current experimental data and results from natural circulation experiments previously conducted in the TSTL in a cartridge vehicle that is similar in design but has smaller flow areas. This cartridge vehicle and the experimental program were developed to add to the single-phase, natural circulation data collected in the previous iteration of the cartridge loop design, which supports future irradiation experiments and adds to a database that is useful for validating computer models. Comparisons of experimental results to TRACE model predictions is a pertinent step in validating the computational tool for supporting future irradiation experiment design and safety calculations, and comparisons to previous cartridge loop results highlight the impact of the design changes made to the test vehicle. The experiments conducted include several steady state tests and transients, including power ramp, loss of offsite power, and loss of external flow scenarios. This work shows that TRACE can accurately predict temperatures and flow conditions in the cartridge loop and the updated vehicle design achieves higher mass flow rates at the same steady state power levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Experimental Study of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

This paper presents a comprehensive experimental study of the loop operating temperature in a loop heat pipe (LHP) which has two parallel evaporators and two parallel condensers. In a single evaporator LHP, it is well known that the loop operating temperature is a function of the heat load, the sink temperature and the ambient temperature. The objective of the present study emphasizes on the stability of the loop operating temperature and parameters that affects the loop operation. Tests results show that the loop operating temperature is a function of the total system heat load, sink temperature, ambient temperature, and beat load distribution between the two evaporators. Under most conditions, only one compensation chamber (CC) contains two-phase fluid and controls the loop operating temperature, and the other CC is completely filled with liquid. Moreover, as the test condition changes, control of the loop operating temperature often shifted from one CC to another. In spite of complex interactions between various components, the test loop has demonstrated very robust operation even during fast transients.

Ku, Jentung↗

Evaporation from a meniscus within a capillary tube in microgravity

The following represents a summary of progress made on the project 'Evaporation from a Capillary Meniscus in Microgravity' being conducted at the University of Dayton during the period 1 Dec. 1992 to 30 Nov. 1993. The efforts during this first year of the grant focused upon the following specific tasks: (1) application of a 3-D scattering particle image velocimetry technique to thin film velocity field measurement; (2) modeling the thermo-fluid behavior of the evaporating meniscus in 0-g within large diameter capillaries; (3) conceptualization of the space flight test cell (loop) configuration; (4) construction of prototypes of the test loop configuration; (5) conduct of experiments in 0-g in the 2.2 second drop tower at NASA-LeRC to study evaporation from a capillary meniscus within a square cuvette; and (6) investigation of the effect of vibrations on the stability of the meniscus. An overview of the work completed within these six task areas is presented.

Hallinan, K. P.↗

Boiling-Water Reactor Testing Capability in the Advanced Test Reactor

I-Loop is an irradiation facility that is currently being installed at the Advanced Test Reactor. It is a two-loop test facility capable of performing Light Water Reactor (LWR) irradiations in prototypic coolant conditions. The two loops are being installed to be capable of both Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) pressure, temperature, and chemistry environments. Each loop is nominally dedicated as a BWR or PWR for simplicity of operations. In-reactor water loop testing that an I-Loop provides is key to the deployment of new accident tolerant fuel technologies and other advanced LWR fuel concepts. Currently, pressurized water loops are the only testing facilities available to test BWR fuel concepts. Their test environments are non-prototypic at higher pressure/temperature and at single-phase fluid flow conditions. This void in the LWR test bed capabilities is one that the I-Loop is uniquely situated to provide. This report discusses the mechanical design, thermal hydraulic calculations, and neutronic calculations of a proposed standard experiment of accident tolerant BWR fuel concepts. Mechanical design examines the geometry and features of the main components. Thermal hydraulic calculations examine the modeling and results of the two-phase flow options available. Lastly, neutronic calculations examine the Monte Carlo analysis of enrichment, heat rates, and flux spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design, development and test of a capillary pump loop heat pipe

The development of a capillary pump loop (CPL) heat pipe, including computer modeling and breadboard testing, is presented. The computer model is a SINDA-type thermal analyzer, combined with a pressure analyzer, which predicts the transients of the CPL heat pipe during operation. The breadboard is an aluminum/ammonia transport system which contains multiple parallel evaporator and condenser zones within a single loop. Test results have demonstrated the practicality and reliability of such a design, including heat load sharing among evaporators, liquid inventory/temperature control feature, and priming under load. Transport capability for this system is 65 KW-M with individual evaporator pumps managing up to 1.7 KW at a heat flux of 15 W/sq cm. The prediction of the computer model for heat transport capabilities is in good agreement with experimental results.

Kroliczek, E. J.↗

Testing of a Loop Heat Pipe Subjective to Variable Accelerations: Start-up - Part 1

The effect of accelerating forces on the performance of loop heat pipes (LHP) is of interest and importance to terrestrial and space applications. They are being considered for cooling of military combat vehicles and for spinning spacecraft. In order to investigate the effect of an accelerating force on LHP operation, a miniature LHP was installed on a spin table. Variable accelerating forces were imposed on the LHP by spinning the table at different angular speeds. Several patterns of accelerating forces were applied, i.e. continuous spin at different speeds and periodic spin at different speeds and frequencies. The resulting accelerations ranged from 1.17 g's to 4.7 g's. This paper presents the first part of the experimental study, i.e. the effects of a centrifugal force on the LHP start-up. Tests were conducted by varying the heat load to the evaporator, sink temperature, magnitude and frequency of centrifugal force, and LHP orientation relative to the direction of the accelerating force. The accelerating force seems to have little effect on the loop start-up in terms of temperature overshoot and superheat at boiling incipience. Changes in these parameters seem to be stochastic with or without centrifugal accelerating forces. The LHP started successfully in all tests.

Ku, Jentung↗

Testing of a Loop Heat Pipe Subjective to Variable Accelerations: Temperature Stability - Part 2

The effect of accelerating forces on the performance of loop heat pipes (LHP) is of interest and importance to terrestrial and space applications. LHP's are being considered for cooling of military combat vehicles and for spinning spacecraft. In order to investigate the effect of an accelerating force on LHP operation, a miniature LHP was installed on a spin table. Variable accelerating forces were imposed on the LHP by spinning the table at different angular speeds. Several patterns of accelerating forces were applied, i.e. continuous spin at different speeds and periodic spin at different speeds and frequencies. The resulting accelerations ranged from 1.17 g's to 4.7 g's. This paper presents the second part of the experimental study, i.e. the effect of an accelerating force on the LHP operating temperature. It has been known that in stationary tests the LHP operating temperature is a function of the evaporator power and the condenser sink temperature when the compensation temperature is not actively controlled. Results of this test program indicate that any change in the accelerating force will result in a chance in the LHP operating temperature through its influence on the fluid distribution in the evaporator, condenser and compensation chamber. However, the effect is not universal, rather it is a function of other test conditions. A steady, constant acceleration may result in an increase or decrease of the operating temperature, while a periodic spin will lead to a quasi-steady operating temperature over a sufficient time interval. In addition, an accelerating force may lead to temperature hysteresis and changes in the temperature oscillation. In spite of all these effects, the LHP continued to operate without any problems in all tests.

Ku, Jentung↗

Thermal Vacuum Test of GLAS Propylene Loop Heat Pipe Development Model

This paper presents viewgraphs on Thermal Vacuum Tests of the GLAS (Geoscience Laser Altimeter System) Propylene Loop Heat Pipe Development Model. The topics include: 1) Flight LHP System (Laser); 2) Test Design and Objectives; 3) DM (Development Model) LHP (Loop Heat Pipe) Test Design; 4) Starter Heater and Coupling Blocks; 5) CC Control Heaters and PRT; 6) Heater Plates (Shown in Reflux Mode); 7) Startup Tests; 8) CC Control Heater Power Tests for CC Temperature Control; and 9) Control Temperature Stability.

Baker, Charles↗

Advanced Photovoltaic Inverter Functionality using 500 kW Power Hardware-in-Loop Complete System Laboratory Testing: Preprint

With the increasing penetration of distribution connected photovoltaic (PV) systems, more and more PV developers and utilities are interested in easing future PV interconnection concerns by mitigating some of the impacts of PV integration using advanced PV inverter controls and functions. This paper describes the testing of a 500 kW PV inverter using Power Hardware-in-Loop (PHIL) testing techniques. The test setup is described and the results from testing the inverter in advanced functionality modes, not commonly used in currently interconnected PV systems, are presented. PV inverter operation under PHIL evaluation that emulated both the DC PV array connection and the AC distribution level grid connection are shown for constant power factor (PF) and constant reactive power (VAr) control modes. The evaluation of these modes was completed under varying degrees of modeled PV variability.

14 SOLAR ENERGY↗

Topics in the AdS/CFT Correspondence: Precision tests with Wilson loops, quantum black holes and dualities

The Anti de Sitter/Conformal Field Theory (AdS/CFT) correspondence conjectures a mathematical equivalence between string theories and gauge theories. This correspondence and its generalizations allow to address difficult problems of strongly coupled field theory dynamics using weakly couple gravity. It also allows to tackle fundamental questions of gravity, such as black hole entropy, using field theories. The research supported by this grant focused on quantum aspects of the AdS/CFT correspondence at sub-leading level. Various results were obtained for expectation values of supersymmetric Wilson loops and for sub-leading entropy corrections of certain asymptotically AdS black holes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated Coronal Loop Identification Using Digital Image Processing Techniques

The results of a master thesis project on a study of computer algorithms for automatic identification of optical-thin, 3-dimensional solar coronal loop centers from extreme ultraviolet and X-ray 2-dimensional images will be presented. These center splines are proxies of associated magnetic field lines. The project is pattern recognition problems in which there are no unique shapes or edges and in which photon and detector noise heavily influence the images. The study explores extraction techniques using: (1) linear feature recognition of local patterns (related to the inertia-tensor concept), (2) parametric space via the Hough transform, and (3) topological adaptive contours (snakes) that constrains curvature and continuity as possible candidates for digital loop detection schemes. We have developed synthesized images for the coronal loops to test the various loop identification algorithms. Since the topology of these solar features is dominated by the magnetic field structure, a first-order magnetic field approximation using multiple dipoles provides a priori information in the identification process. Results from both synthesized and solar images will be presented.