Search NASA⌕ Search

SEARCH · Search NASA

Results for “method of cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

MAC/GMC Code Enhanced for Coupled Electromagnetothermoelastic Analysis of Smart Composites

Intelligent materials are those that exhibit coupling between their electromagnetic response and their thermomechanical response. This coupling allows smart materials to react mechanically (e.g., an induced displacement) to applied electrical or magnetic fields (for instance). These materials find many important applications in sensors, actuators, and transducers. Recently interest has arisen in the development of smart composites that are formed via the combination of two or more phases, one or more of which is a smart material. To design with and utilize smart composites, designers need theories that predict the coupled smart behavior of these materials from the electromagnetothermoelastic properties of the individual phases. The micromechanics model known as the generalized method of cells (GMC) has recently been extended to provide this important capability. This coupled electromagnetothermoelastic theory has recently been incorporated within NASA Glenn Research Center's Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC). This software package is user friendly and has many additional features that render it useful as a design and analysis tool for composite materials in general, and with its new capabilities, for smart composites as well.

Bednarcyk, Brett A.↗

Kinetic simulations of ignited mode cesium vapor thermionic converters

Cesium vapor thermionic converters are an attractive method of converting high-temperature heat directly to electricity, but theoretical descriptions of the systems have been difficult due to the multi-step ionization of Cs through inelastic electron–neutral collisions. This work presents particle-in-cell simulations of these converters, using a direct simulation Monte Carlo collision model to track 52 excited states of Cs. Here, these simulations show the dominant role of multi-step ionization, which also varies significantly based on both the applied voltage bias and pressure. The electron energy distribution functions are shown to be highly non-Maxwellian in the cases analyzed here. A comparison with previous approaches is presented, and large differences are found in ionization rates due especially to the fact that previous approaches have assumed Maxwellian electron distributions. Finally, an open question regarding the nature of the plasma sheaths in the obstructed regime is discussed. The one-dimensional simulations did not produce stable obstructed regime operation and thereby do not support the double-sheath hypothesis.

30 DIRECT ENERGY CONVERSION↗

Apparatus and method for determining state of change (SOC) and state of health (SOH) of electrical cells

Systems and methods for prediction of state of charge (SOH), state of health (SOC) and other characteristics of batteries using acoustic signals, includes determining acoustic data at two or more states of charge and determining a reduced acoustic data set representative of the acoustic data at the two or more states of charge. The reduced acoustic data set includes time of flight (TOF) shift, total signal amplitude, or other data points related to the states of charge. Machine learning models use at least the reduced acoustic dataset in conjunction with non-acoustic data such as voltage and temperature for predicting the characteristics of any other independent battery.

25 ENERGY STORAGE↗

Apparatus and method for determining state of change (SOC) and state of health (SOH) of electrical cells

Systems and methods for prediction of state of charge (SOH), state of health (SOC) and other characteristics of batteries using acoustic signals, includes determining acoustic data at two or more states of charge and determining a reduced acoustic data set representative of the acoustic data at the two or more states of charge. The reduced acoustic data set includes time of flight (TOF) shift, total signal amplitude, or other data points related to the states of charge. Machine learning models use at least the reduced acoustic dataset in conjunction with non-acoustic data such as voltage and temperature for predicting the characteristics of any other independent battery.

Steingart, Daniel Artemis↗

Comparative performance and technoeconomic analyses of two microalgae harvesting systems evaluated at a commercially relevant scale

Using a commercially scalable system designed for processing thousands of liters a day, here we evaluated the factors that affected the performance, energy consumption and capital/operating costs of both flocculation-based and filtration-based algal harvesting systems over a 16 month period. Coagulation efficiency was the primary driver of harvest efficiency in the flocculation-based method, while cell lysis was important for the filtration-based method. Culture (algae) age differentially influenced harvest efficiency through changes in cell fragility and stickiness. The average energy consumption of the flocculation-based method was 0.389 kWh/m 3 , while that for the filtration-based method was 4.343 kWh/m 3 . The average harvesting cost of the filtration-based method was 5.35 $\$$/m 3 , while for flocculation-based method it was 4.52 $\$$/m 3 . The concentration factor of filtration-based and flocculation-based method were 770–1086 and 407–448, respectively. For both harvesting methods, labor costs dominated and ranged from 55.84%–67.94% of total cost. Further system automation is a potential method to lower the harvesting cost. The filtration-based harvesting method could produce a better quality of algal biomass with higher concentration factors and less ash content, but needed more energy input, as compared with a flocculation-based method. This study highlights the importance of algal culture status to successful harvesting, and it also provides insight into developing more efficient harvesting technology with lower energy and capital cost.

59 BASIC BIOLOGICAL SCIENCES↗

Noiseless Vlasov–Poisson simulations with linearly transformed particles

We introduce a deterministic discrete-particle simulation approach, the Linearly-Transformed Particle-In-Cell (LTPIC) method, that employs linear deformations of the particles to reduce the noise traditionally associated with particle schemes. Formally, transforming the particles is justified by local first order expansions of the characteristic flow in phase space. In practice the method amounts of using deformation matrices within the particle shape functions; these matrices are updated via local evaluations of the forward numerical flow. Because it is necessary to periodically remap the particles on a regular grid to avoid excessively deforming their shapes, the method can be seen as a development of Denavit's Forward Semi-Lagrangian (FSL) scheme (Denavit, 1972 [8]). However, it has recently been established (Campos Pinto, 2012 [20]) that the underlying Linearly-Transformed Particle scheme converges for abstract transport problems, with no need to remap the particles; deforming the particles can thus be seen as a way to significantly lower the remapping frequency needed in the FSL schemes, and hence the associated numerical diffusion. To couple the method with electrostatic field solvers, two specific charge deposition schemes are examined, and their performance compared with that of the standard deposition method. Finally, numerical 1d1v simulations involving benchmark test cases and halo formation in an initially mismatched thermal sheet beam demonstrate some advantages of our LTPIC scheme over the classical PIC and FSL methods. Benchmarked test cases also indicate that, for numerical choices involving similar computational effort, the LTPIC method is capable of accuracy comparable to or exceeding that of state-of-the-art, high-resolution Vlasov schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of impurities and processing on silicon solar cells. Volume 1: Characterization methods for impurities in silicon and impurity effects data base

Two major topics are treated: methods to measure and evaluate impurity effects in silicon and comprehensive tabulations of data derived during the study. Discussions of deep level spectroscopy, detailed dark I-V measurements, recombination lifetime determination, scanned laser photo-response, conventional solar cell I-V techniques, and descriptions of silicon chemical analysis are presented and discussed. The tabulated data include lists of impurity segregation coefficients, ingot impurity analyses and estimated concentrations, typical deep level impurity spectra, photoconductive and open circuit decay lifetimes for individual metal-doped ingots, and a complete tabulation of the cell I-V characteristics of nearly 200 ingots.

Hopkins, R. H.↗

Large-cell Monte Carlo renormalization of irreversible growth processes

Monte Carlo sampling is applied to a recently formulated direct-cell renormalization method for irreversible, disorderly growth processes. Large-cell Monte Carlo renormalization is carried out for various nonequilibrium problems based on the formulation dealing with relative probabilities. Specifically, the method is demonstrated by application to the 'true' self-avoiding walk and the Eden model of growing animals for d = 2, 3, and 4 and to the invasion percolation problem for d = 2 and 3. The results are asymptotically in agreement with expectations; however, unexpected complications arise, suggesting the possibility of crossovers, and in any case, demonstrating the danger of using small cells alone, because of the very slow convergence as the cell size b is extrapolated to infinity. The difficulty of applying the present method to the diffusion-limited-aggregation model, is commented on.

Nakanishi, H.↗

Scalable fabrication and coating methods for perovskite solar cells and solar modules

Since the report in 2012 of a solid-state perovskite solar cell (PSC) with a power-conversion efficiency (PCE) of 9.7% and a stability of 500 h, intensive efforts have been made to increase the certified PCE, reaching 25.2% in 2019. The PCE of PSCs now exceeds that of conventional thin-film solar-cell technologies, and the rate at which this increase has been achieved is unprecedented in the history of photovoltaics. Moreover, the development of moisture-stable and heat-stable materials has increased the stability of PSCs. Small-area devices (<1 cm2) are typically fabricated using a spin-coating method; however, this approach may not be suitable for the preparation of the large-area (>100 cm2) substrates required for commercialization. Thus, materials and methods need to be developed for coating large-area PSCs. In this Review, we discuss solution-based and vapour-phase coating methods for the fabrication of large-area perovskite films, examine the progress in performance and the parameters affecting the properties of large-area coatings, and provide an overview of the methodologies for achieving high-efficiency perovskite solar modules.

14 SOLAR ENERGY↗

Quantitative method of measuring cancer cell urokinase and metastatic potential

The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated urokinase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

Morrison, Dennis R.↗

Efficient Nonthermal Ion and Electron Acceleration Enabled by the Flux-Rope Kink Instability in 3D Nonrelativistic Magnetic Reconnection

The relaxation of field-line tension during magnetic reconnection gives rise to a universal Fermi acceleration process involving the curvature drift of particles. However, the efficiency of this mechanism is limited by the trapping of energetic particles within flux ropes. Using 3D fully kinetic simulations, we demonstrate that the flux-rope kink instability leads to strong field-line chaos in weak-guide-field regimes where the Fermi mechanism is most efficient, thus allowing particles to transport out of flux ropes and undergo further acceleration. As a consequence, both ions and electrons develop clear power-law energy spectra that contain a significant fraction of the released energy. The low-energy bounds are determined by the injection physics, while the high-energy cutoffs are limited only by the system size. Furthermore, these results have strong relevance to observations of nonthermal particle acceleration in space and astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

MAC/GMC 4.0 User's Manual: Keywords Manual

This document is the second volume in the three volume set of User's Manuals for the Micromechanics Analysis Code with Generalized Method of Cells Version 4.0 (MAC/GMC 4.0). Volume 1 is the Theory Manual, this document is the Keywords Manual, and Volume 3 is the Example Problem Manual. MAC/GMC 4.0 is a composite material and laminate analysis software program developed at the NASA Glenn Research Center. It is based on the generalized method of cells (GMC) micromechanics theory, which provides access to the local stress and strain fields in the composite material. This access grants GMC the ability to accommodate arbitrary local models for inelastic material behavior and various types of damage and failure analysis. MAC/GMC 4.0 has been built around GMC to provide the theory with a user-friendly framework, along with a library of local inelastic, damage, and failure models. Further, applications of simulated thermo-mechanical loading, generation of output results, and selection of architectures to represent the composite material have been automated in MAC/GMC 4.0. Finally, classical lamination theory has been implemented within MAC/GMC 4.0 wherein GMC is used to model the composite material response of each ply. Consequently, the full range of GMC composite material capabilities is available for analysis of arbitrary laminate configurations as well. This volume describes the basic information required to use the MAC/GMC 4.0 software, including a 'Getting Started' section, and an in-depth description of each of the 22 keywords used in the input file to control the execution of the code.

Bednarcyk, Brett A.↗

MAC/GMC 4.0 User's Manual: Example Problem Manual

This document is the third volume in the three volume set of User's Manuals for the Micromechanics Analysis Code with Generalized Method of Cells Version 4.0 (MAC/GMC 4.0). Volume 1 is the Theory Manual, Volume 2 is the Keywords Manual, and this document is the Example Problems Manual. MAC/GMC 4.0 is a composite material and laminate analysis software program developed at the NASA Glenn Research Center. It is based on the generalized method of cells (GMC) micromechanics theory, which provides access to the local stress and strain fields in the composite material. This access grants GMC the ability to accommodate arbitrary local models for inelastic material behavior and various types of damage and failure analysis. MAC/GMC 4.0 has been built around GMC to provide the theory with a user-friendly framework, along with a library of local inelastic, damage, and failure models. Further, application of simulated thermo-mechanical loading, generation of output results, and selection of architectures to represent the composite material, have been automated in MAC/GMC 4.0. Finally, classical lamination theory has been implemented within MAC/GMC 4.0 wherein GMC is used to model the composite material response of each ply. Consequently, the full range of GMC composite material capabilities is available for analysis of arbitrary laminate configurations as well. This volume provides in-depth descriptions of 43 example problems, which were specially designed to highlight many of the most important capabilities of the code. The actual input files associated with each example problem are distributed with the MAC/GMC 4.0 software; thus providing the user with a convenient starting point for their own specialized problems of interest.

Bednarcyk, Brett A.↗

Effect of polarity on beam and plasma target formation in a dense plasma focus

Dense plasma focus (DPF) devices are conventionally operated with a polarity such that the inner electrode (IE) is the anode. It has been found that interchanging the polarity of the electrodes (i.e., IE as the cathode) can cause an order of magnitude decrease in the neutron yield. This polarity riddle has previously been studied empirically through several experiments and is yet not well understood. Herein, we have performed kinetic simulations using the particle-in-cell modeling to investigate the problem. This is the first time that both polarities have been studied with simulations in great detail. In our simulations, we have modeled the entire beam and plasma target formation processes, but we did not consider differences in break-down conditions caused by the two polarities. We have found that when using reverse polarity ions are still accelerated and, in fact, attain similar energy spectra as in the standard polarity case. The difference is that the fields are flipped and thus ions are accelerated in the opposite direction. So, in the reverse polarity case, the majority of the “plasma target” (formed by the imploding plasma) is in the opposite direction of the beam, and thus, the beam hits the IE and produces few neutrons. With a better inner electrode configuration, reverse polarity is able to create a high-quality ion beam as well as a high-density target. Both can be comparable to that generated by standard polarity. Furthermore, we will show that it is easier to add an additional solid catcher target to a DPF device with reverse polarity, potentially enabling it to generate more neutrons than standard polarity.

Plasma sheaths↗

Impacts of intentional mycoplasma contamination on CHO cell bioreactor cultures

Mycoplasma contamination events in biomanufacturing facilities can result in loss of production and costly cleanups. Mycoplasma may survive in mammalian cell cultures with only subtle changes to the culture and may penetrate the 0.2 µm filters often used in the primary clarification of harvested cell culture fluid. Culture cell-based and indicator cell-based assays that are used to detect mycoplasma are highly sensitive but can take up to 28 days to complete and cannot be used for real-time decision making during the biomanufacturing process. To support real-time measurements of mycoplasma contamination, there is a push to explore nucleic acid testing. However, cell-based methods measure growth or colony forming units and nucleic acid testing measures genome copy number; this has led to ambiguity regarding how to compare the sensitivity of the methods. In addition, the high risk of conducting experiments wherein one deliberately spikes mycoplasma into bioreactors has dissuaded commercial groups from performing studies to explore the multiple variables associated with the upstream effects of a mycoplasma contamination in a manufacturing setting. Here we studied the ability of Mycoplasma arginini to persist in a single-use, perfusion rocking bioreactor system containing a Chinese hamster ovary (CHO) DG44 cell line expressing a model monoclonal immunoglobulin G1 (IgG1) antibody. We examined M. arginini growth and detection by culture methods, as well as the effects of M. arginini on mammalian cell health, metabolism, and productivity. We compared process parameters and controls normally measured in bioreactors including dissolved oxygen, gas mix, and base addition to maintain pH, to examine parameter changes as potential indicators of contamination. Our work showed that M. arginini affects CHO cell growth profile, viability, nutrient consumption, oxygen use, and waste production at varying timepoints after M. arginini introduction to the culture. Importantly, how the M. arginini contamination impacts the CHO cells is influenced by the concentration of CHO cells and rate of perfusion at the time of M. arginini spike. Careful evaluation of dissolved oxygen, pH control parameters, ammonia, and arginine over time may be used to indicate Mycoplasma contamination events in biomanufacturing facilities can result in loss of production and costly cleanups. Mycoplasma may survive in mammalian cell cultures with only subtle changes to the culture and may penetrate the 0.2 µm filters often used in the primary clarification of harvested cell culture fluid. Culture cell-based and indicator cell-based assays that are used to detect mycoplasma are highly sensitive but can take up to 28 days to complete and cannot be used for real-time decision making during the biomanufacturing process. To support real-time measurements of mycoplasma contamination, there is a push to explore nucleic acid testing. However, cell-based methods measure growth or colony forming units and nucleic acid testing measures genome copy number; this has led to ambiguity regarding how to compare the sensitivity of the methods. In addition, the high risk of conducting experiments wherein one deliberately spikes mycoplasma into bioreactors has dissuaded commercial groups from performing studies to explore the multiple variables associated with the upstream effects of a mycoplasma contamination in a manufacturing setting. Here we studied the ability of Mycoplasma arginini to persist in a single-use, perfusion rocking bioreactor system containing a Chinese hamster ovary (CHO) DG44 cell line expressing a model monoclonal immunoglobulin G1 (IgG1) antibody. We examined M. arginini growth and detection by culture methods, as well as the effects of M. arginini on mammalian cell health, metabolism, and productivity. We compared process parameters and controls normally measured in bioreactors including dissolved oxygen, gas mix, and base addition to maintain pH, to examine parameter changes as potential indicators of contamination. Our work showed that M. arginini affects CHO cell growth profile, viability, nutrient consumption, oxygen use, and waste production at varying timepoints after M. arginini introduction to the culture. Importantly, how the M. arginini contamination impacts the CHO cells is influenced by the concentration of CHO cells and rate of perfusion at the time of M. arginini spike. Careful evaluation of dissolved oxygen, pH control parameters, ammonia, and arginine over time may be used to indicate Mycoplasma contamination events in biomanufacturing facilities can result in loss of production and costly cleanups. Mycoplasma may survive in mammalian cell cultures with only subtle changes to the culture and may penetrate the 0.2 µm filters often used in the primary clarification of harvested cell culture fluid. Culture cell-based and indicator cell-based assays that are used to detect mycoplasma are highly sensitive but can take up to 28 days to complete and cannot be used for real-time decision making during the biomanufacturing process. To support real-time measurements of mycoplasma contamination, there is a push to explore nucleic acid testing. However, cell-based methods measure growth or colony forming units and nucleic acid testing measures genome copy number; this has led to ambiguity regarding how to compare the sensitivity of the methods. In addition, the high risk of conducting experiments wherein one deliberately spikes mycoplasma into bioreactors has dissuaded commercial groups from performing studies to explore the multiple variables associated with the upstream effects of a mycoplasma contamination in a manufacturing setting. Here we studied the ability of Mycoplasma arginini to persist in a single-use, perfusion rocking bioreactor system containing a Chinese hamster ovary (CHO) DG44 cell line expressing a model monoclonal immunoglobulin G1 (IgG1) antibody. We examined M. arginini growth and detection by culture methods, as well as the effects of M. arginini on mammalian cell health, metabolism, and productivity. We compared process parameters and controls normally measured in bioreactors including dissolved oxygen, gas mix, and base addition to maintain pH, to examine parameter changes as potential indicators of contamination. Our work showed that M. arginini affects CHO cell growth profile, viability, nutrient consumption, oxygen use, and waste production at varying timepoints after M. arginini introduction to the culture. Importantly, how the M. arginini contamination impacts the CHO cells is influenced by the concentration of CHO cells and rate of perfusion at the time of M. arginini spike. Careful evaluation of dissolved oxygen, pH control parameters, ammonia, and arginine over time may be used to indicate mycoplasma contamination in CHO cell cultures in a bioreactor before a read-out from a traditional method.

59 BASIC BIOLOGICAL SCIENCES↗

Ion density waves driving the formation of filamentary dust structures

The PlasmaKristall-4 (PK-4) experiment on the International Space Station allows for the study of the 3-dimensional interaction between plasma and dust particles. Previous simulations of the PK-4 environment have discovered fast moving ionization waves in the dc discharge. These ionization waves vary the plasma parameters by up to an order of magnitude, which may affect the mechanisms responsible for the self-organization of chains seen in the PK-4 experiment. Here, we adapt a molecular dynamics simulation to employ temporally varying plasma conditions in order to investigate the effect on the dust charging and electrostatic potential. In order to describe the differences between the average of the plasma conditions and the time-varying plasma condition, we present a model to reproduce the interaction that takes into account the negative potential from the dust grain and the positive potential from the ion wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗