Search NASA⌕ Search

SEARCH · Search NASA

Results for “modularization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Modular space station program option

The study to determine whether a viable space station experiment program of 5 to 10 years duration could be defined that would reduce the projected program cost of $6 billion is presented. The options considered are limited to a six-man capability. The identification and description of the options, impact assessment of these options on the space station design, and the costs and schedules for encompassing each option are summarized. It is concluded that viable space station programs of 5 to 10 years duration are attainable; however, the 10-year program offers a significantly greater return on the investment.

Source record↗

Modular space station phase B extension: Mass properties

The MSS system, capable of supporting a six-man crew, is described as consisting of four common station modules, two special modules (core and power), and a cargo module arranged in a cruciform. The station buildup, and space station subsystems including environmental control life support, electrical power, guidance and control are also described. The MSS system weights are presented for design-to-weight, closeout weights, and shuttle payload weights.

Duffey, L. A.↗

Control and protection system for paralleled modular static inverter-converter systems

A control and protection system was developed for use with a paralleled 2.5-kWe-per-module static inverter-converter system. The control and protection system senses internal and external fault parameters such as voltage, frequency, current, and paralleling current unbalance. A logic system controls contactors to isolate defective power conditioners or loads. The system sequences contactor operation to automatically control parallel operation, startup, and fault isolation. Transient overload protection and fault checking sequences are included. The operation and performance of a control and protection system, with detailed circuit descriptions, are presented.

Birchenough, A. G.↗

Thermal control system for a spacecraft modular housing

The development of a thermal control system for a spacecraft module is discussed. The wall structures are composed of superinsulation in some cases and of thermally conductive material in other cases. Heat pipes are installed to provide a path of heat transfer from the interior of the module to space. The design of the system makes it possible to maintain a relatively uniform temperature throughout the module with side variations of the amount of heat dissipated by the components within the module.

Eby, R. J.↗

Reuseable lightweight modular multi-layer insulation for space shuttle

The adaptation of the Self Evacuating Multilayer Insulation System to the space shuttle orbiter liquid hydrogen tanks was investigated. Small scale material screening tests and subscale panel tests demonstrated the potential of the insulation to withstand the anticipated 100 flight cycles. The composition of the material and the process for producing the finished insulation are described. Results of the various tests to determine the durability of the material are presented.

Burr, K. F.↗

A modular Space Station/Base electrical power system - Requirements and design study.

The requirements and procedures necessary for definition and specification of an electrical power system (EPS) for the future space station are discussed herein. The considered space station EPS consists of a replaceable main power module with self-contained auxiliary power, guidance, control, and communication subsystems. This independent power source may 'plug into' a space station module which has its own electrical distribution, control, power conditioning, and auxiliary power subsystems. Integration problems are discussed, and a transmission system selected with local floor-by-floor power conditioning and distribution in the station module. This technique eliminates the need for an immediate long range decision on the ultimate space base power sources by providing capability for almost any currently considered option.

Eliason, J. T.↗

Atmosphere-entry behavior of a modular, disk-shaped, isotope heat source.

The authors have studied the entry and impact behavior of an isotope heat source for space nuclear power that disassembles into a number of modules which would enter the earth's atmosphere separately if a flight aborted. These modules are disk-shaped units, each with its own reentry heat shield and protective impact container. In normal operation, the disk modules are stacked inside the generator, but during a reentry abort they separate and fly as individual units of low ballistic coefficient. Flight tests at hypersonic speeds have confirmed that a stack of disks will separate and assume a flat-forward mode of flight. Free-fall tests of single disks have demonstrated a nominal impact velocity of 30 m/sec at sea level for a practical range of ballistic coefficients.

Vorreiter, J. W.↗

Flange design for large-scale modular assembly jigs

Technique incorporates weld-free method for securing flanges to projecting ends of unmachined box-beam framework so flanged structure may be reused without modification. One such framework may be readily assembled to another by simply matching flanges together and passing connecting members between preformed holes in structures.

Gilman, M. M.↗

Random-access technique for modular bathymetry data storage in a continental shelf wave refraction program

A study was conducted of an alternate method for storage and use of bathymetry data in the Langley Research Center and Virginia Institute of Marine Science mid-Atlantic continental-shelf wave-refraction computer program. The regional bathymetry array was divided into 105 indexed modules which can be read individually into memory in a nonsequential manner from a peripheral file using special random-access subroutines. In running a sample refraction case, a 75-percent decrease in program field length was achieved by using the random-access storage method in comparison with the conventional method of total regional array storage. This field-length decrease was accompanied by a comparative 5-percent increase in central processing time and a 477-percent increase in the number of operating-system calls. A comparative Langley Research Center computer system cost savings of 68 percent was achieved by using the random-access storage method.

Poole, L. R.↗

The MIST (Minus Integration and Subsystems Test) Laboratory: A testbed for the MIUS (Modular Integrated Utility System) program

The MIUS program develops an economically feasible integrated utility system. The MIUS concept integrates utility services in order to achieve resource, energy and environmental benefits. A testbed integrated utility system, called the MIST laboratory, was completed early in 1974 and has begun a long term program to develop data for MIUS. A description of the MIST is presented and the critical design issues which can only be verified by test, are discussed in detail.

Beckham, W. S., Jr.↗