Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Central Stars of Planetary Nebulae in the LMC

In FUSE cycle 2's program B001 we studied Central Stars of Planetary Nebulae (CSPN) in the Large Magellanic Could. All FUSE observations have been successfully completed and have been reduced, analyzed and published. The analysis and the results are summarized below. The FUSE data were reduced using the latest available version of the FUSE calibration pipeline (CALFUSE v2.2.2). The flux of these LMC post-AGB objects is at the threshold of FUSE's sensitivity, and thus special care in the background subtraction was needed during the reduction. Because of their faintness, the targets required many orbit-long exposures, each of which typically had low (target) count-rates. Each calibrated extracted sequence was checked for unacceptable count-rate variations (a sign of detector drift), misplaced extraction windows, and other anomalies. All the good calibrated exposures were combined using FUSE pipeline routines. The default FUSE pipeline attempts to model the background measured off-target and subtracts it from the target spectrum. We found that, for these faint objects, the background appeared to be over-estimated by this method, particularly at shorter wavelengths (i.e., < 1000 A). We therefore tried two other reductions. In the first method, subtraction of the measured background is turned off and and the background is taken to be the model scattered-light scaled by the exposure time. In the second one, the first few steps of the pipeline were run on the individual exposures (correcting for effects unique to each exposure such as Doppler shift, grating motions, etc). Then the photon lists from the individual exposures were combined, and the remaining steps of the pipeline run on the combined file. Thus, more total counts for both the target and background allowed for a better extraction.

Bianchi, Luciana↗

Planetary Science with Balloon-Borne Telescopes

The National Aeronautics and Space Administration (NASA) and the planetary science community have recently been exploring the potential contributions of stratospheric balloons to the planetary science field. A study that was recently concluded explored the roughly 200 or so science questions raised in the Planetary Decadal Survey report and found that about 45 of those questions are suited to stratospheric balloon based observations. In September of 2014, a stratospheric balloon mission called BOPPS (which stands for Balloon Observation Platform for Planetary Science) was flown out of Fort Sumner, New Mexico. The mission had two main objectives, first, to observe a number of planetary targets including one or more Oort cloud comets and second, to demonstrate the applicability and performance of the platform, instruments, and subsystems for making scientific measurements in support planetary science objectives. BOPPS carried two science instruments, BIRC and UVVis. BIRC is a cryogenic infrared multispectral imager which can image in the.6-5 m range using an HgCdTe detector. Narrow band filters were used to allow detection of water and CO2 emission features of the observed targets. The UVVis is an imager with the science range of 300 to 600 nm. A main feature of the UVVis instrument is the incorporation of a guide camera and a Fine Steering Mirror (FSM) system to reduce image jitter to less than 100 milliarcseconds. The BIRC instrument was used to image targets including Oort cloud comets Siding Spring and Jacques, and the dwarf planet 1 Ceres. BOPPS achieved the first ever earth based CO2 observation of a comet and the first images of water and CO2 of an Oort cloud comet (Jacques). It also made the first ever measurement of 1Ceres at 2.73 m to refine the shape of the infrared water absorption feature on that body. The UVVis instrument, mounted on its own optics bench, demonstrated the capability for image correction both from atmospheric disturbances as well as some of the residual motion from the gondola that was not addressed by the gondolas coarse pointing systems. The mission met its primary science and engineering objectives. The results of the BOPPS mission will feed into the body of science knowledge but also feed into future planning for more science from balloon-borne platforms. A notional platform called Gondola for High-Altitude Planetary Science (GHAPS) has been explored and this concept platform can address a number of important decadal questions. This paper provides a summary of the assessment of potential balloon borne observations for planetary science purposes including where potential science contributions can be expected, the necessary performance characteristics of the platform, and other features required or desired. The BOPPS mission is summarized including descriptions of the main elements and key science and engineering results. The paper then briefly describes GHAPS, and the salient features that can make it a valuable tool for future planetary observations.

Telescope↗

SU-E-T-417: A Method for Predicting and Correcting the Dosimetric Effect of a Radiotherapy Treatment Couch in Actual Treatment Position

Purpose: Although radiation attenuation by the treatment couch can be included in the calculation of radiotherapy dose, difference between planned and actual treatment couch positions can generate significant dose discrepancies. We propose a method to predict and correct the dosimetric effect of the couch in actual treatment position. Methods: The couch transmission factor, T, varies with beam angle, G, couch lateral position, x, and vertical position, y, i.e., T=T(x,y,G). If T(x,y,G) is known for a fixed couch vertical position y=h, the transmission of central-axis beam (CAX) T(x,y,G) can be obtained by T(x,y,G)=T(x{sup +},h,G), where x{sup +}=x-(y-h)tan(G) and G is the angle between the beam and the vertical axis. Similarly, the transmission of any off-CAX point can be obtained using a similar formula. We measured CAX couch transmission at a fixed couch vertical position over the couch lateral motion range for all gantry angles by continuously scanning rotating arc beams. A 2D couch transmission correction matrix can thus be generated from T(x,h,G) for each treatment field for the actual couch position. By applying the transmission correction matrix to the planned field dose, the couch effect can be predicted and corrected. To verify this method, we measured couch transmission T(x, y=10cm, G=225°)(225°=IEC 135°) and compared to that obtained from equivalent T(x{sup +}, y=3cm, G=225°) over the range of lateral motion with a step size of 2 cm . Results: The measured couch transmission factors T(x, y=10cm, G=225°) are in excellent agreement with those obtained from the equivalent T(x{sup +}, y=3cm, G=225°). The mean difference is 0.00406±0.00135. Conclusion: The couch transmission correction matrix for any couch position and beam angle can be obtained from one set of scanning measurements at a fixed couch vertical position. The dosimetric effect of the treatment couch can be predicted and corrected by applying the couch transmission correction to the planned dose.

60 APPLIED LIFE SCIENCES↗

Charged particle motion in the vicinity of a neutral plane

The motion of a charged particle in a 2-dimensional neutral sheet with linear magnetic field variation is analyzed by Hamiltonian methods. From the basic Hamiltonian formulation, results of Sonnerup are recovered and given intuitive interpretation. The transformed Hamiltonian is used to derive the correct frequency of oscillation and serves as the basis of analytical treatment of perturbed versions of the motion, e.g. with electric field added. For 2-dimensional fields with slightly differing configurations - in particular, with added small field component orthogonal to the sheet, with an X-type null or with a chain of null points - two alternative methods are developed, reducing the problem either to motion in a 2-dimensional potential or to a pair of coupled oscillators.

Stern, D.↗

DYNAMICAL CENTERS AND NONCIRCULAR MOTIONS IN THINGS GALAXIES: IMPLICATIONS FOR DARK MATTER HALOS

We present harmonic decompositions of the velocity fields of 19 galaxies from The H I Nearby Galaxy Survey (THINGS) which quantify the magnitude of the noncircular motions in these galaxies and yield observational estimates of the elongations of the dark matter halo potentials. Additionally, we present accurate dynamical center positions for these galaxies. We show that the positions of the kinematic and photometric centers of the large majority of the galaxies in our sample are in good agreement. The median absolute amplitude of the noncircular motions, averaged over our sample, is 6.7 km s{sup -1}, with {approx}90% of the galaxies having median noncircular motions of less than {approx}9 km s{sup -1}. As a fraction of the total rotation velocity, this translates into 4.5% on average. The mean elongation of the gravitational potential, after a statistical correction for an unknown viewing angle, is 0.017 {+-} 0.020, which is consistent with a round potential. Our derived noncircular motions and elongations are smaller than what is needed to bring cold dark matter (CDM) simulations in agreement with the observations. In particular, the amplitudes of the noncircular motions are not high enough to hide the steep central mass-density profiles predicted by CDM simulations. We show that the amplitudes of the noncircular motions decrease toward lower luminosities and later Hubble types.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recursive diagonalization of quantum Hamiltonians to all orders in ({Dirac_h}/2{pi})

We present a diagonalization method for generic matrix valued Hamiltonians based on a formal expansion in power of ({Dirac_h}/2{pi}). Considering ({Dirac_h}/2{pi}) as a running parameter, a differential equation connecting two diagonalization processes for two very close values of ({Dirac_h}/2{pi}) is derived. The integration of this differential equation allows the recursive determination of the series expansion in powers of ({Dirac_h}/2{pi}) for the diagonalized Hamiltonian. This approach results in effective Hamiltonians with Berry-phase corrections of higher order in ({Dirac_h}/2{pi}), and deepens previous works on the semiclassical diagonalization of quantum Hamiltonians, which led notably to the discovery of the intrinsic spin Hall effect. As physical applications we consider spinning massless particles in isotropic inhomogeneous media and show that both the energy and the velocity get quantum corrections of order ({Dirac_h}/2{pi}){sup 2}. We also derive formally to all orders in ({Dirac_h}/2{pi}) the energy spectrum and the equations of motion of Bloch electrons in an external electric field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The motion of the earth-moon system in modern tabular ephemerides. II - Inertial motion, mean longitude of the sun, and general precession in longitude

Properties of astronomical time scales (ET and UT) are considered, with particular emphasis on correctly determining of-date longitude as the sum of inertial mean longitude of the sun relative to the mean equinox of a fixed epoch (1950.0), and the general precession in longitude accumulated since the epoch. The inertial mean longitude and motion (relative to the mean equinox) are derived from tabular ephemerides such as the Jet Propulsion Laboratories' DE 102 and DE 96, by comparisons with subroutines based on Newcomb's perturbation theory. An unresolved inconsistency of approximately 1 second per century among the mean inertial motion of DE 102, IAU precession speed (1976), and the classical Newcomb of-date mean motion is found. Interpretation difficulties arising from the use of different systems of Ephemeris Time are also discussed.

Stumpff, P.↗

Experimental validation of the van Herk margin formula for lung radiation therapy

Purpose: To validate the van Herk margin formula for lung radiation therapy using realistic dose calculation algorithms and respiratory motion modeling. The robustness of the margin formula against variations in lesion size, peak-to-peak motion amplitude, tissue density, treatment technique, and plan conformity was assessed, along with the margin formula assumption of a homogeneous dose distribution with perfect plan conformity.Methods: 3DCRT and IMRT lung treatment plans were generated within the ORBIT treatment planning platform (RaySearch Laboratories, Sweden) on 4DCT datasets of virtual phantoms. Random and systematic respiratory motion induced errors were simulated using deformable registration and dose accumulation tools available within ORBIT for simulated cases of varying lesion sizes, peak-to-peak motion amplitudes, tissue densities, and plan conformities. A detailed comparison between the margin formula dose profile model, the planned dose profiles, and penumbra widths was also conducted to test the assumptions of the margin formula. Finally, a correction to account for imperfect plan conformity was tested as well as a novel application of the margin formula that accounts for the patient-specific motion trajectory.Results: The van Herk margin formula ensured full clinical target volume coverage for all 3DCRT and IMRT plans of all conformities with the exception of small lesions in soft tissue. No dosimetric trends with respect to plan technique or lesion size were observed for the systematic and random error simulations. However, accumulated plans showed that plan conformity decreased with increasing tumor motion amplitude. When comparing dose profiles assumed in the margin formula model to the treatment plans, discrepancies in the low dose regions were observed for the random and systematic error simulations. However, the margin formula respected, in all experiments, the 95% dose coverage required for planning target volume (PTV) margin derivation, as defined by the ICRU; thus, suitable PTV margins were estimated. The penumbra widths calculated in lung tissue for each plan were found to be very similar to the 6.4 mm value assumed by the margin formula model. The plan conformity correction yielded inconsistent results which were largely affected by image and dose grid resolution while the trajectory modified PTV plans yielded a dosimetric benefit over the standard internal target volumes approach with up to a 5% decrease in the V20 value.Conclusions: The margin formula showed to be robust against variations in tumor size and motion, treatment technique, plan conformity, as well as low tissue density. This was validated by maintaining coverage of all of the derived PTVs by 95% dose level, as required by the formal definition of the PTV. However, the assumption of perfect plan conformity in the margin formula derivation yields conservative margin estimation. Future modifications to the margin formula will require a correction for plan conformity. Plan conformity can also be improved by using the proposed trajectory modified PTV planning approach. This proves especially beneficial for tumors with a large anterior–posterior component of respiratory motion.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-207-01: Markerless Respiratory Motion Tracking with Contrast Enhanced Thoracic Cone Beam CT Projections

Purpose: To develop a novel technique to enhance the image contrast of clinical cone beam CT projections and extract respiratory signals based on anatomical motion using the modified Amsterdam Shroud (AS) method to benefit image guided radiation therapy. Methods: Thoracic cone beam CT projections acquired prior to treatment were preprocessed to increase their contrast for better respiratory signal extraction. Air intensity on raw images was firstly estimated and then applied to correct the projections to generate new attenuation images that were subsequently improved with deeper anatomy feature enhancement through taking logarithm operation, derivative along superior-inferior direction, respectively. All pixels on individual post-processed two dimensional images were horizontally summed to one column and all projections were combined side by side to create an AS image from which patient’s respiratory signal was extracted. The impact of gantry rotation on the breathing signal rendering was also investigated. Ten projection image sets from five lung cancer patients acquired with the Varian Onboard Imager on 21iX Clinac (Varian Medical Systems, Palo Alto, CA) were employed to assess the proposed technique. Results: Application of the air correction on raw projections showed that more than an order of magnitude of contrast enhancement was achievable. The typical contrast on the raw projections is around 0.02 while that on attenuation images could greater than 0.5. Clear and stable breathing signal can be reliably extracted from the new images while the uncorrected projection sets failed to yield clear signals most of the time. Conclusion: Anatomy feature plays a key role in yielding breathing signal from the projection images using the AS technique. The air correction process facilitated the contrast enhancement significantly and attenuation images thus obtained provides a practical solution to obtaining markerless breathing motion tracking.

60 APPLIED LIFE SCIENCES↗

A parton picture of de Sitter space during slow-roll inflation

It is well-known that expectation values in de Sitter space are afflicted by infra-red divergences. Long ago, Starobinsky proposed that infra-red effects in de Sitter space could be accommodated by evolving the long-wavelength part of the field according to the classical equations of motion plus a stochastic source term. I argue that - when quantum-mechanical loop corrections are taken into account - the separate universe picture of superhorizon evolution in de Sitter space is equivalent, in a certain leading-logarithm approximation, to Starobinsky's stochastic approach. In particular the time evolution of a box of de Sitter space can be understood in exact analogy with the DGLAP evolution of partons within a hadron, which describes a slow logarithmic evolution in the distribution of the hadron's constituent partons with the energy scale at which they are probed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computation of potential flows with embedded vortex rings and applications to helicopter rotor wakes

A finite difference scheme for solving the motion of a number of vortex rings is developed. The method is an adaptation of the 'cloud-in-cell' technique to axisymmetric flows, and is thus a combined Eulerian-Lagrangian technique. A straightforward adaptation of the cloud-in-cell scheme to an axisymmetric flow field is shown to introduce a grid dependent self-induced velocity to each vortex ring. To correct this behavior the potential is considered to consist of two parts, a local and a global field. An improved difference formula is derived, allowing the accurate calculation of the potential at points near vortex locations. The local potential is then subtracted before calculating the velocity, leaving only the influences of the remaining vortices. The correct self-induced velocity is then explicitly added to the vortex velocity. Calculations of the motion of one and two vortex rings are performed, demonstrating the ability of the new method to eliminate the grid dependence of the self-induced velocity. The application of the method to the calculation of helicopter rotor flows in hover is attempted.

Roberts, T. W.↗

Time Dependence of Intrafraction Patient Motion Assessed by Repeat Stereoscopic Imaging

Purpose: To quantify intrafraction patient motion and its time dependence in immobilized intracranial and extracranial patients. The data can be used to optimize the intrafraction imaging frequency and consequent patient setup correction with an image guidance and tracking system, and to establish the required safety margins in the absence of such a system. Method and Materials: The intrafraction motion of 32 intracranial patients, immobilized with a thermoplastic mask, and 11 supine- and 14 prone-treated extracranial spine patients, immobilized with a vacuum bag, were analyzed. The motion was recorded by an X-ray, stereoscopic, image-guidance system. For each group, we calculated separately the systematic (overall mean and SD) and the random displacement as a function of elapsed intrafraction time. Results: The SD of the systematic intrafraction displacements increased linearly over time for all three patient groups. For intracranial-, supine-, and prone-treated patients, the SD increased to 0.8, 1.2, and 2.2 mm, respectively, in a period of 15 min. The random displacements for the prone-treated patients were significantly higher than for the other groups, namely 1.6 mm (1 SD), probably caused by respiratory motion. Conclusions: Despite the applied immobilization devices, patients drift away from their initial position during a treatment fraction. These drifts are in general small if compared with conventional treatment margins, but will significantly contribute to the margin for high-precision radiation treatments with treatment times of 15 min or longer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broadband (0–5 Hz) Fully Deterministic 3D Ground‐Motion Simulations of a Magnitude 7.0 Hayward Fault Earthquake: Comparison with Empirical Ground‐Motion Models and 3D Path and Site Effects from Source Normalized Intensities

We report on high‐performance computing (HPC) fully deterministic simulation of ground motions for a moment magnitude (⁠Mw⁠) 7.0 scenario earthquake on the Hayward fault resolved to 5 Hz using the SW4 finite‐difference code. We computed motions obeying physics‐based 3D wave propagation at a regional scale with an Mw 7.0 kinematic rupture model generated following Graves and Pitarka (2016). Both plane‐layered (1D) and 3D Earth models were considered, with 3D subsurface material properties and topography interpolated from a model of the U.S. Geological Survey (USGS). The resulting ground‐motion intensities cover a broader frequency range than typically considered in regional‐scale simulations, including higher frequencies relevant for engineering analysis of structures. Median intensities for sites across the domain are within the reported between‐event uncertainties (⁠τ⁠) of ground‐motion models (GMMs) across spectral periods 0.2–10 s (frequencies 0.1–5 Hz). The within‐event standard deviation ϕ of ground‐motion intensity measurement residuals range 0.2–0.5 natural log units with values consistently larger for the 3D model. Source‐normalized ratios of intensities (3D/1D) reveal patterns of path and site effects that are correlated with known geologic structure. These results demonstrate that earthquake simulations with fully deterministic wave propagation in 3D Earth models on HPC platforms produce broadband ground motions with median and within‐event aleatory variability consistent with empirical models. Systematic intensity variations for the 3D model caused by path and site effects suggest that these epistemic effects can be estimated and removed to reduce variation in site‐specific hazard estimates. This study motivates future work to evaluate the validity of the USGS 3D model and investigate the development of path and site corrections by running more scenarios.

Rodgers, Arthur J.↗

Barbero-Immirzi parameter as a scalar field: K-inflation from loop quantum gravity?

We consider a loop-quantum gravity inspired modification of general relativity, where the Holst action is generalized by making the Barbero-Immirzi (BI) parameter a scalar field, whose value could be dynamically determined. The modified theory leads to a nonzero torsion tensor that corrects the field equations through quadratic first derivatives of the BI field. Such a correction is equivalent to general relativity in the presence of a scalar field with nontrivial kinetic energy. This stress energy of this field is automatically covariantly conserved by its own dynamical equations of motion, thus satisfying the strong equivalence principle. Every general relativistic solution remains a solution to the modified theory for any constant value of the BI field. For arbitrary time-varying BI fields, a study of cosmological solutions reduces the scalar-field stress energy to that of a pressureless perfect fluid in a comoving reference frame, forcing the scale-factor dynamics to be equivalent to those of a stiff equation of state. Upon ultraviolet completion, this model could provide a natural mechanism for k inflation, where the role of the inflaton is played by the BI field and inflation is driven by its nontrivial kinetic energy instead of a potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct atomic fabrication and dopant positioning in Si using electron beams with active real-time image-based feedback

We report that semiconductor fabrication is a mainstay of modern civilization, enabling the myriad applications and technologies that underpin everyday life. However, while sub-10 nanometer devices are already entering the mainstream, the end of the Moore's law roadmap still lacks tools capable of bulk semiconductor fabrication on sub-nanometer and atomic levels, with probe-based manipulation being explored as the only known pathway. Here we demonstrate that the atomic-sized focused beam of a scanning transmission electron microscope can be used to manipulate semiconductors such as Si on the atomic level, inducing growth of crystalline Si from the amorphous phase, reentrant amorphization, milling, and dopant front motion. These phenomena are visualized in real-time with atomic resolution. We further implement active feedback control based on real-time image analytics to automatically control the e-beam motion, enabling shape control and providing a pathway for atom-by-atom correction of fabricated structures in the near future. Lastly, these observations open a new epoch for atom-by-atom manufacturing in bulk, the long-held dream of nanotechnology.

36 MATERIALS SCIENCE↗

Ab initio calculations of the rate of carrier trapping and release at dopant sites in NaI: Tl beyond the harmonic approximation

We present ab initio calculations of electron capture and release coefficients as a function of temperature for Tl dopants in the widely used scintillator NaI, which is a soft ionic crystal. The modelled capture and release events occur by transitions mediated by multiple phonon absorption and emission between states with significantly different local geometries around the trapping site. We demonstrate that such transitions are not well-described by the normal harmonic approximation to the nuclear dynamics. We avoid the harmonic approximation by numerically solving the vibrational Schrödinger equation for the motion along/of a single effective phonon coordinate. The localized trapped state is not correctly described by semilocal density functionals, so we employ a hybrid functional tuned to reproduce the band gap and lattice constant of the host material. Our calculations, which combine plane-wave and cluster electronic structure methods in a novel way, are in reasonable agreement with available experimental data for detrapping and predict an unusual temperature dependence for trapping rates.

Prange, Micah P.↗

{delta}-mediated pion production in nuclei

We present a fully relativistic formalism for describing neutrino-induced {delta}-mediated single-pion production in nuclei. We assess the ambiguities stemming from the {delta} interactions and quantify the uncertainties in the axial form-factor parameters by comparing with the available bubble-chamber neutrino-scattering data. To include nuclear effects, we turn to a relativistic plane-wave impulse approximation (RPWIA) using realistic bound-state wave functions derived in the Hartree approximation to the {sigma}-{omega} Walecka model. For neutrino energies larger than 1 GeV, we show that a relativistic Fermi-gas model with appropriate binding-energy correction produces results that are comparable to the RPWIA that naturally includes Fermi motion, nuclear-binding effects, and the Pauli exclusion principle. Including {delta} medium modifications roughly halves the RPWIA cross section. Calculations for primary (prior to undergoing final-state interactions) pion production are presented for both electron- and neutrino-induced processes, and a comparison with electron-scattering data and other theoretical approaches is included. We infer that the total {delta}-production strength is underestimated by about 20 to 25%, a fraction that is due to the pionless decay modes of the {delta} in a medium. The model presented in this work can be naturally extended to include the effect of final-state interactions in a relativistic and quantum-mechanical way.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗