Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Multiple Uplinks Per Antenna (MUPA) Signal Acquisition Schemes

The Deep Space Network (DSN) currently makes use of the technique of Multiple Spacecraft per Antenna (MSPA) where a single antenna is used to track multiple spacecraft downlinks within its beam, such as in the case of multiple spacecraft orbiting Mars at 8.4 GHz (X-band). It is desired to extend this technique to the uplink where a single station is used to send a signal to multiple spacecraft in order to make more efficient use of ground resources. This would be applicable to numerous smallsat constellations being considered for future missions or to future spacecraft at Venus, Mars, or more distant destinations that are all within the half-power beamwidth of a single 34-m diameter antenna. In one scheme, each spacecraft’s command sequences would be time multiplexed onto a single uplink frequency. Each spacecraft would lock onto the uplink signal and would accept only commands intended for it via special identifier codes. Each spacecraft would also emit a downlink signal to the ground that is coherent with the uplink signal but would have its own allocated frequency channel and identifier information. A couple of key challenges associated with using this technique need to be addressed. Because of the single uplink frequency, coherent turnaround for two-way Doppler and ranging would not conform to established ratios, thus the radios employed by the spacecraft would need to be capable of variable turnaround ratios. In addition, because of the different orbits or spacecraft trajectories, the relative Doppler shifts and rates can be large with respect to the common uplink signal whose frequency would lie at the centroid of the frequencies of the expected received signals of the constellation. This would be problematic with standard analog spacecraft radios whose acquisition bandwidths are relatively small (~1.7 kHz) relative to the large frequency offsets (~100 kHz) expected using the single frequency uplink technique. With the advent of software defined radios (SDRs), signal frequency search algorithms can be utilized within the flight software and/or programmable hardware (e.g., FPGAs) that can easily acquire and track signals with large frequency offsets and varying dynamics. Such techniques could include FFT search algorithms, step-and-sweep search algorithms, or onboard frequency steering making use of trajectory vectors uplinked to each member spacecraft. Other challenges include mitigation of potential interference between received signals. We have identified several software defined radios that are in different stages of development and whose key parameters have been tabulated. We have examined each radio’s capabilities with respect to acquiring and tracking signals with large frequency offsets. Such analyses made use of previous studies supplemented with specially designed tests using both simulation tools and/or existing testbeds. We have compared signal acquisition times computed from provided algorithms along with measured values derived from tests using existing hardware and simulation tools for the purpose of conducting tradeoff studies between the various radio designs and software/firmware programming approaches.

Abraham, Douglas S.↗

Mechanical Design of a High Energy Beam Absorber for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab

A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type SRF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two beam absorbers. The facility is designed to accommodate up to 6 cryomodules, which would produce a 75kW beam at 1.5GeV; this is the driving design condition for the beam absorbers. The beam absorbers consist of water-cooled graphite, aluminum and copper layers contained in a helium-filled enclosure. This paper describes the mechanical implementation of the beam absorbers, with a focus on thermal design and analysis. The potential for radiation-induced degradation of the graphite is discussed.

43 PARTICLE ACCELERATORS↗

Hyper-Velocity Nanoparticle Plasma Jet as Fast Probe for Runaway Electrons in Tokamak Disruptions

The large energy focalized deposition of the runaway electron (RE) beam on the first wall can potentially yield to destructive effects on the reactor vessel during the explosive instability of a major disruption in a large tokamak (e.g. RE beam estimation is multi-MA of ~10 MeV energy in ITER.) Impurity injection is seen as an effective way to suppress REs after thermal quench (TQ). Injected material in solid state is advantageous, but it must be in small size grain form, with large surface-to-mass ratio to facilitate its rapid ablation within plasma. However, the results using shattered pellet injection (SPI), a technique aiming to satisfy these condition, indicated that the relatively unexplored RE evolution phases and RE beam-plasma interaction are far from being properly diagnosed and fully understood. We proposed the idea to probe REs with a pulsed power hyper-velocity large-mass nanoparticle plasma jet (NPPJ). NPPJ provides a high specific surface area and swift injection to core, hence fast increase of three basic parameters: 1) the electron density ne (bound and free through ionization, if the cold post-TQ plasma has a still high enough T e ), 2) the effective charge (Z eff ) which rises both the dynamical friction force and plasma resistivity, and, finally, 3) the value of the (Dreicer and critical) threshold E-field above which electrons are accelerated and become REs. But the fast transient phenomena of RE ”seed” creation, RE ”avalanche” multiplication, and RE beam formation and interaction with the background plasma all take place dominantly in the core plasma, where the induction E-field has its maximum. Thus, the RE probe success requires a rapid (1 - 2 ms) injection of sufficient mass able to penetrate through the strong toroidal magnetic field (2 - 5 T) over a long distance (~1 - 2 m) with a large assimilation fraction in the core plasma. As a RE probe, NPPJ is a unique combination of fast response with trigger-to-delivery time of few milliseconds, large mass-velocity (>75 mg at several km/s) and deep injection into post-TQ central plasma. The Objectives of this Category #1 project (concept development) were as follows: 1: We investigated the essential basic physics aspects of creating a plasma with ~10 15 to 10 16 cm -3 boron nitride (BN) NP density suited for a pulsed power plasma gun acceleration to several km/s. We concluded that, for RE NPPJ probe, BN (diameter Ø10 to 100 nm NPs) are in all respects usable. 2: We advanced solutions to get BN NPPJ by adapting FAR-TECH’s technology for C 60 NPPJ. 3: We developed self-consistent models for RE current density j RE (R; t) evolution in the TQ aftermath, with fast and simultaneous increase of n e (R; t) and Z eff (R; t) > 1 upon the specific injection of C 60 (i.e. C ions) and BN NP (i.e. B and N ions), respectively. We showed that prompt post-TQ injection and high velocity are of essence in RE probe diagnostics and suppression. 4: We used the in-house HEM-2D code to simulate the C$_{60}^{q+}$ NPPJ transverse penetration through tokamak-level B-field (BT ~2 to 5 T) and distance (~1 to 2m), with fragmentation of C$_{60}^{q+}$ and developed the algorithm for BN Q+ NPPJ ablative sublimation of BN Q+ NP by the collisions with post-TQ plasma electrons. HEM-2D results indicated that fragmenting C$_{60}^{1+}$ NPPJ penetrates up to ~60 cm in 100 us when injecting at 1.6 ms after TQ and gradually released C 2 fragments and C ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A finite element model investigation of ultrasonic array performance for inspecting polycrystalline materials

Microstructural noise has long hindered ultrasonic NDE of polycrystalline materials. In recent years however, arrays have enabled new possibilities to advance ultrasonic inspection of these materials. A Finite Element (FE) model is used to explore the different phenomena caused by grain scattering which may hinder detection of defects by an array. These include multiple scattering and beam deviation due to anisotropy; two aspects of the physics which are often required to be ignored in analytical models due to theoretical assumptions or computational limitations. We rely on a GPU based FE solver, Pogo, to provide fast computation and thereby enable parametric studies. The impact on array detection performance when varying center-frequency and aperture size is investigated. Preliminary results show that there exists an optimum for both the array aperture and frequency for inspection of these materials.

36 MATERIALS SCIENCE↗

Stitching-error reduction in gratings by shot-shifted electron-beam lithography

Calculations of the grating spatial-frequency spectrum and the filtering properties of multiple-pass electron-beam writing demonstrate a tradeoff between stitching-error suppression and minimum pitch separation. High-resolution measurements of optical-diffraction patterns show a 25-dB reduction in stitching-error side modes.

Integrated optics semiconductor lasersgratings↗

SU-E-T-305: Dosimetric Comparison of Cyberknife Versus Linac Based VMAT Stereotactic Treatment Planning for Localised Prostate Cancer

Purpose: The purpose of this study was to compare dosimetric indices of Cyberknife versus Linac for localised prostate cancer Methods: In this study, twenty patients were taken from Cyberknife Multiplan TPS v 4.6.0. All these patients underwent hypo fractionated boost treatment for localised prostate cancer in Cyberknife with the prescription dose of 18Gy in 3 fractions. For each patient VMAT stereotactic plans were generated in Monaco TPS v 5.0 using Elekta beam modulator MLC machine for 6MV photon beam. The plans quality were evaluated by comparing dosimetry indices such that D95, D90, D5 for target volume and V100, V80, V50, V30 for critical organs. The p values were calculated for target and OAR to ascertain the significant differences. Results: For each case, D95 of target coverage was achieved with 100% prescription dose with p value of 0.9998. The p value for D90, D5 and V100 for linac and Cyberknife plans was 0.9938, 0.9918 and 0.9838 respectively. For rectum, rectum-PTV and bladder doses were significantly less in Cyberknife compared to linac plans. For rectum, rectum-PTV and bladder at V100 the p value is 0.2402, 0.002, and 0.1615 respectively. Other indices V80, V50 and V30 were comparable in both plans. Conclusion: This study demonstrated that both linac and Cyberknife plans were shown adequate target coverage, while in Cyberknife the treatment time is longer and more MUs to be delivered. However, better conformity, lesser doses to the critical organs and dose gradient outside target for localised prostate treatment were achieved in Cyberknife plans due to multiple non coplanar beam arrangements.

60 APPLIED LIFE SCIENCES↗

Instrumentation for Sensitive Gas Measurements

An improved instrument for optical absorption spectroscopy utilizes off-axis paths in an optical cavity in order to increase detection sensitivity while suppressing resonance effects. The instrument is well suited for use in either cavity ring-down spectroscopy (CRDS) [in which one pulses an incident light beam and measures the rate of decay of light in the cavity] or integrated cavity output spectroscopy (ICOS) [in which one uses a continuous-wave incident light beam and measures the power of light in the cavity as a function of wavelength]. Typically, in optical absorption spectroscopy, one seeks to measure absorption of a beam of light in a substance (usually a gas or liquid) in a sample cell. In CRDS or ICOS, the sample cell is placed in (or consists of) an optical cavity, so that one can utilize multiple reflections of the beam to increase the effective optical path length through the absorbing substance and thereby increase the sensitivity for measuring absorption. If an absorbing substance is not present in the optical cavity, one can utilize the multiple passes of the light beam to increase the sensitivity for measuring absorption and scattering by components of the optical cavity itself. It is desirable to suppress the effects of resonances in the cavity in order to make the spectral response of the cavity itself as nearly constant as possible over the entire wavelength range of interest. In the present instrument, the desired flattening of the spectral response is accomplished by utilizing an off-axis beam geometry to effectively decrease the frequency interval between longitudinal electromagnetic modes of the cavity, such that the resulting transmission spectrum of the cavity is nearly continuous: in other words, the cavity becomes a broad-band optical device.

OKeefe, Anthony↗

Improving magnitude and phase comparison metrics for frequency response functions using cross-correlation and log-frequency shifting

This paper provides a new method for matching dominant features of Frequency Response Functions (FRFs). In particular, this paper proposes a slicing and shifting method where the key features (in this case, resonant amplitudes) of a baseline FRF are compared with a similar FRF using cross-correlation and a Log-Frequency Shift (LFS). Here, the goal is to provide an alternative to classic point-to-point methods for FRF comparison and instead to match the dominant features of two FRFs in a way similar to visual inspection. This enables existing FRF comparison metrics to then be applied with greater fidelity. Additionally, this paper introduces the Phase Similarity Metric (PSM) for comparing phases of two FRFs and illustrates the improvement of using LFS for phase comparisons as well. This paper uses a cantilever beam experiment in multiple configurations to provide a benchmark case for FRF comparison improvements.

42 ENGINEERING↗

The performance of the γ-ray tracking array GRETINA for γ-ray spectroscopy with fast beams of rare isotopes

The gamma-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The gamma-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the gamma-ray analysis in terms of Doppler reconstruction and spectral quality. Finally, the results reported in this work were obtained from GRETINA consisting of 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbital Angular Momentum-based Space Division Multiplexing for High-capacity Underwater Optical Communications

To increase system capacity of underwater optical communications, we employ the spatial domain to simultaneously transmit multiple orthogonal spatial beams, each carrying an independent data channel. In this paper, we show up to a 40-Gbit/s link by multiplexing and transmitting four green orbital angular momentum (OAM) beams through a single aperture. Moreover, we investigate the degrading effects of scattering/turbidity, water current, and thermal gradient-induced turbulence, and we find that thermal gradients cause the most distortions and turbidity causes the most loss. We show systems results using two different data generation techniques, one at 1064 nm for 10-Gbit/s/beam and one at 520 nm for 1-Gbit/s/beam; we use both techniques since present data-modulation technologies are faster for infrared (IR) than for green. For the 40-Gbit/s link, data is modulated in the IR, and OAM imprinting is performed in the green using a specially-designed metasurface phase mask. For the 4-Gbit/s link, a green laser diode is directly modulated. Lastly, we show that inter-channel crosstalk induced by thermal gradients can be mitigated using multi-channel equalisation processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling Solid Rayleigh-Taylor Growth

Intense impulses applied to solid materials result in high strain rates, strong plastic strains and significant temperature increments. Data in such regimes would allow confidence in extending material strength models to strain rates of 10{sup 6}-10{sup 7} s{sup -1}. High explosives can be used to accelerate a plate with a perturbation on the side facing the HE, resulting in a Rayleigh-Taylor-like perturbation growth that depends on amplitude and wavelength of the initial surface perturbation, strength of the material, time dependence of the driving pressure force, and temperature of the material. Such experiments have been conducted on perturbed copper plates at LANL, using the LANSCE proton radiography beam to obtain multiple frames of data for each experiment. The results of numerical simulations of these experiments using a 2-D ALE code are presented.

36 MATERIALS SCIENCE↗

Maximal charge injection of consecutive electron pulses with uniform temporal pulse separation

A charge sheet model is proposed for the study of the space-charge limited density of consecutive electron pulses injected to in a diode with uniform temporal pulse separation. Based on the model, an analytical formula is derived for expressing the dependency of the charge density limit on the gap spacing, gap voltage, and pulse separation. The theoretical results are verified by numerical solutions up to electron energy of a few MeV, including relativistic effects. The model can be applied to the design of multiple-pulse electron beams for time resolved electron microscopy and free electron lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-voltage harmonic multiplying gyrotron traveling-wave amplifier in G band

Harmonic multiplying operation in a gyrotron traveling-wave amplifier (gyro-TWA) permits for magnetic field reduction and frequency multiplication. Lowering a beam voltage is an important step toward miniaturization of a harmonic multiplying gyro-TWA. However, the additional degree of freedom that is provided by the multitude cyclotron harmonics in a low-voltage harmonic multiplying gyro-TWA still easily generates various competing modes. An improved mode-selective circuit, using circular waveguides with various radii, can provide the rejection points within the frequency range to suppress competing modes. Simulated results reveal that the mode-selective circuit can provide an attenuation of more than 14 dB to suppress the competing modes. Furthermore, the performance of the gyro-TWA is analyzed for studying the sensitivity of the saturated output power and full width at half maximum bandwidth of the gyro-TWA to the beam voltage and the magnetic field. A stable low-voltage harmonic multiplying gyro-TWA with the mode-selective circuit is predicted to yield a peak output power of 24 kW at 200.4 GHz, corresponding to a saturated gain of 56 dB at an interaction efficiency of 20%. The full width at half maximum bandwidth is 3.0 GHz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thresholds of absolute two-plasmon-decay and stimulated Raman scattering instabilities driven by multiple broadband lasers

Here, thresholds for the absolute stimulated Raman scattering (SRS) and two-plasma decay (TPD) instabilities driven by multiple broadband laser beams are evaluated using 3-D simulations at conditions relevant to inertial confinement fusion experiments. Multibeam TPD and SRS backscatter are found to be easier to mitigate with bandwidth than the corresponding single-beam instabilities. A relative bandwidth of 1% increases the threshold for absolute SRS backscatter by a factor of 4 at conditions relevant to ongoing National Ignition Facility experiments and should be sufficient to keep all of the absolute instabilities below threshold in experiments with similar conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-angle Precession Electron Diffraction (MAPED): A Versatile Approach to 4D-STEM Precession

Precession of a converged beam during acquisition of a 4D-STEM dataset improves strain, orientation, and phase mapping accuracy by averaging over continuous angles of illumination. Precession experiments usually rely on integrated systems, where automatic alignments lead to fast, high-quality results. The dependence of these experiments on specific hardware and software is evident even when switching to nonintegrated detectors on a precession tool, as experimental set-up becomes challenging and time-consuming. Here, we introduce multi-angle precession electron diffraction (MAPED): a method to perform electron diffraction by collecting sequential 4D-STEM scans at different incident beam tilts. The multiple diffraction datasets are averaged together postacquisition, resulting in a single dataset that minimizes the impact of the curvature and orientation of the Ewald sphere relative to the crystal under study. Our results demonstrate that even four additional tilts improved measurement of material properties, namely strain and orientation, as compared to single-tilt 4D-STEM experiments. We show the versatility and flexibility of our MAPED approach with data collected on a number of microscopes with different hardware configurations and a variety of detectors.

4D-STEM↗

Multilayer on-chip stacked Fresnel zone plates: Hard x-ray fabrication and soft x-ray simulations

Fresnel zone plates are widely used as x-ray nanofocusing optics. To achieve high spatial resolution combined with good focusing efficiency, high aspect ratio nanolithography is required, and one way to achieve that is through multiple e-beam lithography writing steps to achieve on-chip stacking. A two-step writing process producing 50 nm finest zone width at a zone thickness of 1.14 µm for possible hard x-ray applications is shown here. The authors also consider in simulations the case of soft x-ray focusing where the zone thickness might exceed the depth of focus. In this case, the authors compare on-chip stacking with, and without, adjustment of zone positions and show that the offset zones lead to improved focusing efficiency. The simulations were carried out using a multislice propagation method employing Hankel transforms.

Li, Kenan↗

SU-E-T-395: Multi-GPU-Based VMAT Treatment Plan Optimization Using a Column-Generation Approach

Purpose: GPU has been employed to speed up VMAT optimizations from hours to minutes. However, its limited memory capacity makes it difficult to handle cases with a huge dose-deposition-coefficient (DDC) matrix, e.g. those with a large target size, multiple arcs, small beam angle intervals and/or small beamlet size. We propose multi-GPU-based VMAT optimization to solve this memory issue to make GPU-based VMAT more practical for clinical use. Methods: Our column-generation-based method generates apertures sequentially by iteratively searching for an optimal feasible aperture (referred as pricing problem, PP) and optimizing aperture intensities (referred as master problem, MP). The PP requires access to the large DDC matrix, which is implemented on a multi-GPU system. Each GPU stores a DDC sub-matrix corresponding to one fraction of beam angles and is only responsible for calculation related to those angles. Broadcast and parallel reduction schemes are adopted for inter-GPU data transfer. MP is a relatively small-scale problem and is implemented on one GPU. One headand- neck cancer case was used for test. Three different strategies for VMAT optimization on single GPU were also implemented for comparison: (S1) truncating DDC matrix to ignore its small value entries for optimization; (S2) transferring DDC matrix part by part to GPU during optimizations whenever needed; (S3) moving DDC matrix related calculation onto CPU. Results: Our multi-GPU-based implementation reaches a good plan within 1 minute. Although S1 was 10 seconds faster than our method, the obtained plan quality is worse. Both S2 and S3 handle the full DDC matrix and hence yield the same plan as in our method. However, the computation time is longer, namely 4 minutes and 30 minutes, respectively. Conclusion: Our multi-GPU-based VMAT optimization can effectively solve the limited memory issue with good plan quality and high efficiency, making GPUbased ultra-fast VMAT planning practical for real clinical use.

60 APPLIED LIFE SCIENCES↗

SU-F-T-305: Clinical Effects of Dosimetric Leaf Gap (DLG) Values Between Matched Varian Truebeam (TB) Linacs

Purpose: The dosimetric leaf gap (DLG) is an important parameter to be measured for dynamic beam delivery of modern linacs, like the Varian Truebeam (TB). The clinical effects of DLG-values on IMRT and/or VMAT commissioning of two “matched” TB linacs will be presented.Methods and Materials: The DLG values on two TB linacs were measured for all energy modalities (filtered and FFF-modes) as part of the dynamic delivery mode commissioning (IMRT and/or VMAT. After the standard beam data was modeled in eclipse treatment planning system (TPS) and validated, IMRT validation was performed based on TG1191 benchmark, IROC Head-Neck (H&N) phantom and sample of clinical cases, all measured on both linacs. Although there was a single-set of data entered in the TPS, a noticeable difference was observed for the DLG-values between the linacs. The TG119, IROC phantom and selected patient plans were furnished with DLG-values of TB1 for both linacs and the delivery was performed on both TB linacs for comparison. Results: The DLG values of TB1 was first used for both linacs to perform the testing comparisons. The QA comparison of TG119 plans revealed a great dependence of the results to the DLG-values used for the linac for all energy modalities studied, especially when moving from 3%/3mm to 2%/2mm γ-analysis. Conclusion: The DLG-values have a definite influence on the dynamic dose, delivery that increases with the plan complexity. We recommend that the measured DLG-values are assigned to each of the “matched” linacs, even if a single set of beam data describes multiple linacs. The user should perform a detail test of the dynamic delivery of each linac based on end-to-end benchmark suites like TG119 and IROC phantoms.1Ezzel G., et al., “IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.” Med. Phys. 36:5359–5373 (2009). partly supported by CAMC Cancer Center and Alliance Oncology.

60 APPLIED LIFE SCIENCES↗