Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Pulse mode readout techniques for use with non-gridded industrial ionization chambers

Highly sensitive readout technique for precision long-term radiation measurements has been developed and tested in the Radiation Control Department at Jefferson Lab. The new electronics design is used to retrieve ionization data in a pulse mode. The dedicated data acquisition system works with M=Audio Audiophile 192 High-Definition 24-bit/192 kHz audio cards, taking data in continuous waveform recording mode. The on-line data processing algorithms extract signals of the ionization events from the data flow and measure the ionization value for each event. Two different ion chambers are evaluated. The first is a Reuter-Stokes Argon-filled (at 25 atm) High Pressure Ionization Chamber (HPIC), commonly used as a detector part in many GE Reuter-Stokes instruments of the RSS series. The second is a VacuTec Model 70181, 5 atm Xenon-filled ionization chamber. Results for both chambers indicate that the techniques allow using industrial ICs for high sensitivity and precision long-term radiation measurements, while at the same time providing information about spectral characteristics of the radiation fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of metal ion complexation on the radiolytic longevity of butyramide extractants under direct dissolution conditions

The direct dissolution of volox-treated used nuclear fuel (UNF) into an organic solution—comprised of diluent and specialized extractants—poses a promising alternative to the traditional liquid-liquid solvent extraction approach to reprocessing UNF. However, moving to direct dissolution removes the presence of a concentrated nitric acid aqueous phase, which has been shown to significantly influence the radiolytic longevity of extractants in liquid-liquid solvent extraction flowsheets. With this in mind, and given the limited knowledge of radiation effects under direct dissolution conditions, we present a time-resolved and dose accumulation study on the impact of direct dissolution conditions on the radiolytic longevity of two candidate butyramide extractants—N,N-di-(2-ethylhexyl) butyramide (DEHBA) and N,N-di-(2-ethylhexyl)isobutyramide (DEHiBA)—in pre-equilibrated n-dodecane solvent in the presence and absence of process relevant metal ions, uranium and rhenium. Rhenium, and by extension technetium, extraction had little impact (=10%) on the overall radiolytic stability of these ligands, despite observed increases in chemical kinetic reactivity (>2×) of the corresponding complexes with the n-dodecane radical cation. Uranium-loading on the other hand, significantly improved the lifetime of both ligands (>30%) under gamma irradiation, with a greater stabilization observed for DEHBA over DEHiBA. This draft manuscript has been prepared in fulfillment of NTRD-MRWFD-2024 M3FT-24IN030101115.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spectral encoding method for measuring the relative arrival time between x-ray/optical pulses

The advent of few femtosecond x-ray light sources brings promise of x-ray/optical pump-probe experiments that can measure chemical and structural changes in the 10–100 fs time regime. Widely distributed timing systems used at x-ray Free-Electron Laser facilities are typically limited to above 50 fs fwhm jitter in active x-ray/optical synchronization. The approach of single-shot timing measurements is used to sort results in the event processing stage. This has seen wide use to accommodate the insufficient precision of active stabilization schemes. In this article, we review the current technique for “measure-and-sort” at the Linac Coherent Light Source at the SLAC National Accelerator Laboratory. The relative arrival time between an x-ray pulse and an optical pulse is measured near the experimental interaction region as a spectrally encoded cross-correlation signal. The cross-correlation provides a time-stamp for filter-and-sort algorithms used for real-time sorting. Sub-10 fs rms resolution is common in this technique, placing timing precision at the same scale as the duration of the shortest achievable x-ray pulses.

43 PARTICLE ACCELERATORS↗

Effect of charge trapping on effective carrier lifetime in compound semiconductors: High resistivity CdZnTe

The dominant problem limiting the energy resolution of compound semiconductor based radiation detectors is the trapping of charge carriers. The charge trapping affects energy resolution through the carrier lifetime more than through the mobility. Conventionally, the effective carrier lifetime is determined using a 2-step process based on measurement of the mobility-lifetime product (μτ) and determining drift mobility using time-of-flight measurements. This approach requires fabrication of contacts on the sample. A new RF-based pulse rise-time method, which replaces this 2-step process with a single non-contact direct measurement, is discussed. The application of the RF method is illustrated with high-resistivity detector-grade CdZnTe crystals. The carrier lifetime in the measured CdZnTe, depending on the quality of the crystals, was between about 5 μs and 8 μs. These values are in good agreement with the results obtained using conventional 2-step approach. While the effective carrier lifetime determined from the initial portion of the photoresponse transient combines both recombination and trapping in a manner similar to the conventional 2-step approach, both the conventional and the non-contact RF methods offer only indirect evaluation of the effect of charge trapping in the semiconductors used in radiation detectors. Since degradation of detector resolution is associated not with trapping but essentially with detrapping of carriers, and, in particular, detrapping of holes in n-type semiconductors, it is concluded that evaluation of recombination and detrapping during photoresponse decay is better suited for evaluation of compound semiconductors used in radiation detectors. Furthermore, based on previously reported data, it is concluded that photoresponse decay in high resistivity CdZnTe at room temperature is dominated by detrapping of carriers from the states associated with one type of point defect and by recombination of carriers at one type of extended defects. The recombination at the extended defects produces long, logarithmic decay limiting substantially performance of CdZnTe detectors. This decay is associated with the “electrostatic trapping” of excess holes by the Schottky-type depletion space-charge regions formed around the defects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photo-fusion reactions in a new compact device for ELI

In the last few years significant progress on technological, experimental and numerical studies on fusion process in high density and high temperature plasmas produced by a high intensity laser pulse interaction with clusters in a high external applied magnetic field, enable us to propose a compact photo-fusion magnetic device for high neutron production. For the purpose of the project a pulsed magnetic field driver with values up to 110 Tesla has been developed which allows increasing the trapping time of the high density plasma in the device and improving the neutron yield. Numerical simulations show that the proposed device is capable of producing up to 10{sup 9}-10{sup 10} neutrons per laser shot with an external magnetic field of 150 Tesla. The proposed device can be used for experiments and numerical code validation concerning different conventional and (or) exotic fusion fuels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilization of the CW magnetrons as coherent RF sources for superconducting RF accelerators

CW magnetrons designed and optimized for industrial heaters, driven by an injection-locking signal, were suggested to power Superconducting RF (SRF) cavities. However, the CW magnetrons, which are regenerative generators, are intended to operate in self-excitation mode, so, for reliable starting they use a large regenerative gain, causing a large regenerative instability in operation. Thus, power supply ripple, even shot noise, etc., lead to multiple sidebands forming a quasi-continuous noise spectrum at the carrier frequency. Therefore, in the traditionally used mode of operation and control, such magnetrons are inapplicable for powering high Q-factor SRF cavities. A new approach to operation and control of CW magnetrons considering non-stationary processes during start-up and operation makes it possible to find a mode of almost coherent RF generation of tubes with a significant reduction in regenerative instability and noise and increased efficiency. In our work is presented substantiation for the newly developed mode with an analysis of the new approach based on experimental results. •In this article, for the first time, non-stationary, regenerative processes are considered during the start-up and operation of CW magnetrons for powering high-Q superconducting RF cavities.•An analytical study, confirmed by experiments, showed that the traditionally used modes of starting and operating CW magnetrons are not suitable for powering high-Q superconducting RF cavities.•In fact, to make CW magnetrons suitable for such cavities, the physics of starting and operating CW magnetrons must be changed. This has been demonstrated in our work.•In developing the Stimulated Coherent Generation Mode [NIM A 980 (2020) 164366], we have shown the suitability of this mode for starting and operating CW magnetrons for high-Q superconducting RF cavities.•Analytical analysis, verified experimentally, substantiates in our article the suitability of the “Mode of stimulated coherent generation” of CW magnetrons for powering high-Q superconducting cavities in pulsed and continuous modes.

43 PARTICLE ACCELERATORS↗

Novel use of a hand-held laser induced breakdown spectroscopy instrument to monitor hydride corrosion in uranium

With a compact hand-held laser-induced breakdown spectroscopy (LIBS) instrument, studies were performed on specimens of uranium charged with controlled hydrogen concentrations for a qualitative evaluation of hydride corrosion. Four samples of depleted uranium with two different starting microstructures (cast and rolled) were used for this study. The hydrogen charged samples (rolled 1.8 wppm H and cast 14 wppm H by weight) are representative of the pre-corrosion states with hydrides distributed throughout the bulk. In-depth LIBS measurements were carried out, after the thick surface corrosion layer was removed, by applying 100 laser pulses from sample surface into the bulk on five different sample locations. Three additional areas on each sample were investigated by laser ablation using a 12-point grid approach. The atomic emission signals of elemental uranium, carbon, hydrogen, and oxygen were identified and analyzed. All four samples showed similar uranium and carbon concentrations, as expected. Hydrogen content was consistent with each sample's specification, such that the hydrogen charged samples exhibited higher hydrogen concentration than their references. Both specimens charged with hydrogen showed elevated oxygen content as well, due to rapid oxidation of uranium and uranium hydrides. The oxidation process was facilitated by the laser ablation and plasma plume's high temperature effects on the sample combined with the glovebox environment. The uranium surface damage produced by laser ablation was quantitatively evaluated by optical microscopy.

36 MATERIALS SCIENCE↗

Impact of Actinide Complexation on Ligand Radiolysis

Although the actinides boast many unique physical and chemical properties, their inherent susceptibility to radioactive decay are what make them truly interesting elements to study. The absorption of ionizing radiation from actinide decay leads to the formation of a variety of transient and steady-state radicals, ions, and molecular radiolysis products that can lead to significant changes in the surrounding environment, and ultimately dictate steady-state actinide redox distributions and the longevity of molecules designed for actinide complexation. Radiolysis of the latter leads to complexant destruction and the concomitant formation of degradation products that can complicate actinide studies and processes. However, the radiation chemistry of most actinide complexants have been studied in the absence of the actinides they were designed to complex, which can lead to inaccurate conclusions on longevity and degradation product distributions, as metal ion complexation has been historically shown to influence a ligand’s radiolytic behavior. Consequently, bridging this knowledge gap is important for actinide science. Here, I will discuss the impact of actinide complexation on the steady-state and time-resolved radiation-induced reactivity of a variety of complexants, including, tributyl phosphate (TBP) and N,N,N',N'-tetraoctyl diglycolamide (TODGA) .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heteronuclear single quantum coherence (HSQC) NMR spectra of lignin isolated from switchgrass residues after fermentation with milling

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from a herbaceous energy crop (Panicum virgatum L.). The lowland variant “Timber” switchgrass from Ernst seeds was used. The switchgrass was knife milled and passed through a 2 mm sieve prior to consolidated bioprocessing (CBP) process. Switchgrass was suspended in Milli-Q water and autoclaved for 90 min on liquid cycles. The residues after autoclaving were then subjected to CBP using coculture of Clostridium thermocellum (C. thermocellum DSM 1313 (LL1004)) and Thermoanaerobacterium thermosaccarolyticum ( T. thermosaccharolyticum HG-8 ATCC 31960 (LL1244)). Once-fermented and twice-fermented (FF) switchgrass were subjected to ball and disc milling in bioreactors at 55 °C and 60, 48 grams/L solids loadings for primary and secondary fermentation respectively. When fermentations were completed, the residual solids were rinsed with milli-Q water. Lignin was isolated from the pretreated residues after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 600 rpm for 2 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and characterized using 13C–1H HSQC in a Bruker Avance III HD 500-MHz NMR spectrometer. A standard Bruker pulse sequence (hsqcetgpsisp.2) was used on a Prodigy platform cryoprobe. The spectra were acquired with the following acquisition conditions: 230 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 2048 data points, a 90° pulse, with a C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin 3.6 software.

Lignin, HSQC, Switchgrass, CBP , Ball mill, Disc m↗

Evaluating the Effects of Hydride Embrittlement and Pulse Width on Zircaloy Cladding Transient Performance

Pellet Cladding Mechanical Interaction is the primary failure mode for high burnup Zircaloy claddings in Light Water Reactor Reactivity Initiated Accidents. This failure mode is not seen in fresh and lower burnup fuels and is the result of environmental degradation of the cladding material and the unique loading condition on the cladding as a result of the sudden contact forces with the pellet. This paper describes work that is underway at the Idaho National Laboratory to better understand this failure mode by pre-hydriding fresh Zircaloy cladding. The pre-hydrided cladding is being mechanically characterized and will ultimately be used as part of an in-pile testing campaign at the TREAT reactor that will simulate the unique transient loading and heating conditions present in a Reactivity Initiated Accident. A description of the pre-hydriding and mechanical testing processes being followed, and initial results are presented followed by a description of the planned transient testing

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Possible origins of a time-resolved frequency shift in Raman plasma amplifiers

Raman amplification is a resonant process in which the energy of a long pump pulse is transferred to a short seed pulse by a plasma wave. There has been a significant effort to identify a window in parameter space within which the interaction is expected to be highly efficient and not degraded by competing instabilities or excessive damping. However, experimental results have thus far failed to approach the theoretical limits. Recent amplified signal spectra display a characteristic blue shift, which evolves within the seed pulse duration and suggests that the mechanism responsible for this shift is also limiting amplification in these experiments. We present the evidence and explore different hypotheses for the origins of the shift-namely localization in density minima along the axis of laser propagation induced by an ion acoustic wave that could arise from the Langmuir decay instability, filamentation which could also modulate the plasma density but in the plane transverse to laser propagation, particle trapping, and additional ionization induced by the amplified seed field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotically Assisted Sonic Therapy (RAST) for Noninvasive Hepatic Ablation in a Porcine Model: Mitigation of Body Wall Damage with a Modified Pulse Sequence

Purpose: Robotically assisted sonic therapy (RAST) is a nonthermal, noninvasive ablation method based on histotripsy. Prior animal studies have demonstrated the ability to create hepatic ablation zones at the focal point of an ultrasound therapy transducer; however, these treatments resulted in thermal damage to the body wall within the path of ultrasound energy delivery. The purpose of this study was to evaluate the efficacy and safety of a pulse sequence intended to mitigate prefocal body wall injury. Materials and Methods: Healthy swine (n = 6) underwent hepatic RAST (VortxRx software version 1.0.1.3, HistoSonics, Ann Arbor MI) in the right hepatic lobe. A 3.0 cm spherical ablation zone was prescribed for each. Following treatment, animals underwent MRI which was utilized for ablation zone measurement, evaluation of prefocal injury, and assessment of complications. Each animal was euthanized, underwent necropsy, and the tissue was processed for histopathologic analysis of the ablation zone and any other sites concerning for injury. Results: No prefocal injury was identified by MRI or necropsy in the body wall or tissues overlying the liver. Ablation zones demonstrated uniform cell destruction, were nearly spherical (sphericity index = 0.988), and corresponded closely to the prescribed size (3.0 × 3.1 × 3.4 cm, p = 0.70, 0.36, and 0.01, respectively). Ablation zones were associated with portal vein (n = 3, one occlusive) and hepatic vein thrombosis (n = 4, one occlusive); however, bile ducts remained patent within ablation zones (n = 2). Conclusions: Hepatic RAST performed with a modified ultrasound pulse sequence in a porcine model can mitigate prefocal body wall injuries while maintaining treatment efficacy. Further study of hepatic RAST appears warranted, particularly in tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrochemistry of PUREX: R is for Reduction and Ion Transfer

The PUREX (Plutonium, Uranium, Reduction, EXtraction) process is the foundation of all industrial activities that involve the recycling of plutonium and uranium from used nuclear fuel. With over 70 years of research, engineering, and operations, it can be argued that little opportunity is left for further discovery and new fundamental understandings regarding PUREX, in general, and tri-n-butyl phosphate (TBP), in particular. Through use of an advanced electroanalytical approach, molecular-level insights regarding the back-extraction of Pu(IV) by reductive separation is reported. Studies of model PUREX systems, with lanthanide ions extracted into 20 % TBP in n-dodecane, are used to demonstrate the approach. These studies reveal knowledge pertinent to mass transfer aspects of the biphasic reductive stripping reaction central to the separation of U and Pu in PUREX. Two lanthanide ions—Ce(IV) and Yb(III)—were extracted from their concentrated solutions in aqueous 3 M HNO 3 to expressly provide electrically conducting third phases to facilitate electrochemical data acquisition. To simplify the diabolically-complicated reductive separation aspects of PUREX, the controlled polarization of electrode surfaces was used to reduce Ce(IV) and Yb(III) in place of chemical reductants. Electroanalyses of the biphasic systems with Ce(IV) and Yb(III) using three-phase electrode differential pulse voltammetry demonstrate the effects of mass transfer across water-oil interfaces on the electrode potentials for the reduction to Ce(III) and Yb(II). These reductions trigger nitrate transfer out of the oil phase for Ce and proton transfer into the organic phase for Yb. This is in correlation with the transfer of the charge-neutral ion pairs Ce·3NO 3 and Yb·2NO 3 out of the oil phases. Here, the differences in ion transfer steps reflect significant variations in the equilibrium speciation of multinuclear Ce(IV) and mononuclear Yb(III) solvates of TBP in the oil phases and the loading of the organic phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stand-Alone Dynamic System Simulation of a Fissile Solution System

Dynamic system simulations (DSS) of fissile solution systems (FSS) have been performed at Los Alamos National Laboratory (LANL) for several years. DSS have been designed and executed using the DESIRE (Direct Executing Simulation in Real Time) system, a platform ideal for expert system modelers, as it allows for direct mathematical specification of a model, and facilities for performing experiments and analyses with the model. Models built in DESIRE have been compared to historical data from several historic aqueous homogeneous reactors (AHR) showing close agreement between experimental data and model estimates. Historical systems modeled include: SUPO (Super Power), an AHR that operated at Los Alamos National Laboratory from 1951 to 1974; SILENE, which was operated by CEA at Valduc, France until 2011; KEWB (Kinetics Experiment Water Boiler) A-2 and B-5 cores, operated by North American Atomics during the 1960’s and 1970’s. SUPO is considered a benchmark for steady-state operations, SILENE for pulse, and KEWB as confirmatory for both modes. However, there are some simulation tasks that are not well-suited to DESIRE model implementation. These tasks include engineering design and analysis and providing a hardware simulator backend. It has been determined that executable simulation models would better suit these purposes, hence a process for converting DESIRE simulation models to executable simulation models was designed and implemented, and several models have been converted. DESIRE simulation models are converted to C++ executable models by an automated process. The conversion process is quick, accurate and repeatable, giving confidence that converted models will perform as well as the original DESIRE models. Extensive testing on the SUPO and accelerator driven subcritical system models has shown that the executable models perform almost identically to the DESIRE models. All major trends and events are simulated with excellent agreement and the steady-state results typically agree within a small fraction of a percent (always better than 0.1% and generally better than 0.01% agreement).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Real-Time Wavelength Discrimination for Improved Neutron Discrimination in CLYC

We investigated the effects of optical filters on the pulse shape discrimination properties of Cs 2 LiYCl 6 :Ce (CLYC) scintillator crystals. By viewing the scintillation light through various optical filters, we attempted to better distinguish between neutron and gamma ray events in the crystal. We applied commercial interference and colored glass filters in addition to fabricating quantum dot (QD) filters by suspending QDs in plastic films and glass. QD filters ultimately failed because of instability of the QDs with respect to oxidation when exposed to ambient air, and the tendency of the QDs to aggregate in the plastic. Of the commercial filters, the best results were obtained with a bandpass interference filter covering the spectral region containing core-valence luminescence (CVL) light. However, the PSD response of filtered CLYC light was always poorer than the response exhibited by unfiltered light because filters always reduced the amount of light available for signal processing.

36 MATERIALS SCIENCE↗

SENSITIVITY STUDIES OF HEATER ROD DESIGN FOR TRANSIENT CRITICAL HEAT FLUX EXPERIMENTS IN TREAT

An important area of reactor safety is the cladding-to-coolant heat transfer under fast transient conditions. These conditions can occur during events such as a reactivity-initiated accident (RIA). In this paper we present the work performed under a laboratory directed research and development (LDRD) project, headed by Idaho National Laboratory (INL). The goal was to develop a test matrix to inform on the design of a borated steel heater rod that will induce critical heat flux (CHF) within an experimental capsule filled with water, using the TREAT facility, when submitted to a power pulse. The energy deposition in the rod and occurrence of CHF were identified as the most important key Figures of Merit (FoMs) used in the design process. Energy deposition was varied by using different pulse characteristics and various boron concentrations in the rod. A power coupling factor (PCF) was determined for each boron concentration. A sensitivity study determined the lowest limiting PCF needed to induce CHF in water with different degrees of subcooling while keeping pressure constant. Boron concentrations between 0.1-1.54 wt.% were considered. Additionally, the value of CHF is also known to increase during a rapid transient. A CHF multiplier sensitivity study focused on an example case concluded that CHF is no longer exceeded when the value is between 2.6- and 2.9-times higher. Lastly, a self-shielding study was performed to determine whether a borated tube could be used in place of a solid borated rod. The study determined that the inner 1mm of the rod can essentially be excluded or instrumented without heat generation penalties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PTT System Performance Evaluation in 3-D Imaging of AM Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for non-destructive evaluation (NDE) either during or post manufacturing. Known material flaws in AM include low density regions consisting of nonsintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This study investigates the capability of PTT in imaging several AM structures fabricated from Inconel 718 (IN718) feedstock. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of IN718 nozzle plate and a particle filter plate. The results demonstrate the capability of PTT in 3- D imaging of complex geometry AM structures. Further, increased resolution imaging is achieved compared to prior results using older FLIR SC4000 IR camera. In addition, preliminary studies were conducted on developing image processing algorithms for automated detection of flaws. Initial demonstrations are shown for segmentation of PTT images of flat bottom hole (FBH) specimens. Imaging of FBH specimens was described in a prior report. Intermediate results demonstrated in this report will be developed further in detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reproducible, rugged, and inexpensive photocathode x-ray diode

The photoemissive cathode type of x-ray diode (XRD) is popular for measuring time and spectrally resolved output of pulsed power experiments. Vitreous carbon XRDs currently used on the Sandia National Laboratories Z-machine were designed in the early 1980s and use materials and processes no longer available. Additionally cathodes used in the high x-ray flux and dirty vacuum environment of a machine such as Z suffer from response changes requiring recalibration. In searching for a suitable replacement cathode, we discovered very high purity vitreous-carbon planchets are commercially available for use as biological substrates in scanning electron microscope (SEM) work. After simplifying the photocathode mounting to use commercially available components, we constructed a set of 20 XRDs using SEM planchets that were then calibrated at the National Synchrotron Light Source at Brookhaven National Laboratory. We present comparisons of the reproducibility and absolute calibrations between the current vitreous-carbon XRDs and our new design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗