Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Performance Audit Report: Automated Meteorological Monitoring Stations, Lawrence Livermore National Laboratory

The Waste and Air Quality Offices Group at the Lawrence Livermore National Laboratory operates two main meteorological monitoring sites near Livermore, California. The primary met tower (Site 200) is located in the northwest corner of the lab and consists of a fifty-two (52) meter tower with vertical wind speed sensors, horizontal wind speed and direction sensors and air temperature sensors at fifty-two (52) meters, twenty-three (23) meters and ten (10) meters. In addition, there is a temperature and humidity probe at ten (10) meters. At two (2) meters there are upward and downward facing solar and infrared radiation sensors, an air temperature sensor, barometric pressure sensor and a temperature and relative humidity probe. At ground level there is a tipping bucket rain gauge located to the southwest of the tower. The datalogger, communication peripherals and the barometric pressure sensor are housed in a small building near the tower. The Site 300 met site is located approximately 10 miles east of Livermore within the boundary of the LLNL blast test site. This site also consists of a 52-meter tower which is configured the same as the 52-meter tower at Site 200. There is also a building at this site that houses the datalogger, communication peripherals and the barometric pressure sensor. At both Site 200 and Site 300, data are collected by Ethernet with telephone modem collection as a backup. The data collection interval for both sites is fifteen (15) minutes via workstations running Loggernet software located at the main lab facility. The audits of the Lawrence Livermore National Laboratory’s two automated meteorological stations located near Livermore, California were performed on October 24 & 25, 2023. These audits were performed under the guidelines of the Quality Assurance Handbook for Air Pollution Measurement Systems, Volume IV, Version 2 and the On-Site Meteorological Program Guidance for Regulatory Modeling Applications, U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Observations on Cost Modeling and Performance Measurement of Long Term Archives

This paper describes a prototype suite of Excel-based tools that could be used for estimating lifecycle costs for newly planned or modified long-term archival facilities. These tools may also prove valuable for monitoring the long-term performance of such facilities once operational. Cost estimation is by analogy, using statistical curve-fitting techniques across a database of comparable data activities. The database currently includes 29 operational data centers ranging from small (2 FTEs) to large (66 FTEs), and is readily expandable to include additional activities specifically involving data preservation and added value. Each comparable data center is described in terms of its staffing, throughput workload, archival and distribution requirements, levels of user service, overall complexity, degree of automation, and other data, comprising 94 distinct descriptors in all. The descriptors were developed by normalizing heterogeneous data from the various centers and mapping them into an Excel framework consistent with the OAIS reference model. A user-friendly tool is provided for generating input to and updating the comparables database. This tool can also be used to benchmark the performance (in terms of cost versus throughput) of an operational data center, and to update the staffing, cost and workload data on a periodic basis. The comparables database could thus provide a history of staffing and throughput over time, as a means of performance monitoring and providing feedback for continuous improvement. Ancillary tools are also provided for performing "what-if' cost exercises for planning purposes, and for graphical display of data and results. We provide a high-level description of the tools; present our experiences and observations on gathering the information and maintaining the database; and discuss how this tool set might be applied to long term archives.

Fontaine, Kathy↗

An Integrated Hydrological Model for Long-Term Monitoring in Tims Branch Watershed, SC - 19435

The Tims Branch watershed in Savannah River Site (SRS), South Carolina is a small-scale watershed that has been impacted by contaminated runoff and discharge wastewater from nuclear research facilities located within the watershed over the past century. Innovative remediation technologies, such as tin injection and pump and treat, have been implemented to remove heavy metals and volatile organic compounds (VOCs) from the watershed. Today, the Tims Branch watershed serves as a test-bed for monitoring the performance of remediation activities. This study describes the development of the two-dimensional integrated surface water/groundwater model for Tims Branch watershed to assess the impact of cleanup activities on hydrological processes in this watershed. This model will serve as a tool to simulate the effect of climatic events on overland flow distribution and further on will be used to assess contaminant transport. This paper illustrates the application of the developed model for simulation of overland flow depth and velocity in Tims Branch watershed and streamflow in A-014 outfall tributary. The watershed includes the second order Tims Branch stream, several outfalls, and a network of tributaries. Simulation of non-calibrated overland flow was conducted for the years 2016 using available stream flow data within the watershed. Recent flow data from a newly deployed stage gauge was also used to assess the model results. The results show the model ability to simulate overland flow and stream flow and can be used as a tool to represent the hydrological conditions in the Tims Branch watershed. The results of this model simulation will be further used to develop contaminant transport model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Forced Diffusion Chamber Monitoring of Soil CO2 Fluxes from 2019 to Present at NGEE Arctic Teller Site, Mile Marker 27, Alaska

Soil CO2 efflux was monitored at the NGEE Arctic Teller Site, Mile Marker 27, in Alaska. Monitoring was performed beginning in June 2019 using EOSense forced diffusion soil CO2 flux sensors at up to six sites characterized by varying vegetation cover, topographic position, and soil temperature and moisture. Dataset includes measurements of soil CO2 flux and chamber temperature. Time interval between measurements ranges from 5 minutes to 3 hours. Included are EOSense chamber locations as *.kml and *.png files, six *.csv files with measurements, and two *.csv reporting format files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Investigation of Gearbox Vibration Transmission Paths on Gear Condition Indicator Performance

Helicopter health monitoring systems use vibration signatures generated from damaged components to identify transmission faults. For damaged gears, these signatures relate to changes in dynamics due to the meshing of the damaged tooth. These signatures, referred to as condition indicators (CI), can perform differently when measured on different systems, such as a component test rig, or a full-scale transmission test stand, or an aircraft. These differences can result from dissimilarities in systems design and environment under dynamic operating conditions. The static structure can also filter the response between the vibration source and the accelerometer, when the accelerometer is installed on the housing. To assess the utility of static vibration transfer paths for predicting gear CI performance, measurements were taken on the NASA Glenn Spiral Bevel Gear Fatigue Test Rig. The vibration measurements were taken to determine the effect of torque, accelerometer location and gearbox design on accelerometer response. Measurements were taken at the housing and compared while impacting the gear set near mesh. These impacts were made at gear mesh to simulate gear meshing dynamics. Data measured on a helicopter gearbox installed in a static fixture were also compared to the test rig. The behavior of the structure under static conditions was also compared to CI values calculated under dynamic conditions. Results indicate that static vibration transfer path measurements can provide some insight into spiral bevel gear CI performance by identifying structural characteristics unique to each system that can affect specific CI response.

Dempsey, Paula J.↗

In situ embedment of type K sheathed thermocouples with directed energy deposition

Advanced nuclear reactor systems require new technologies for heat transfer and system monitoring. Additive manufacturing (AM) offers the design flexibility to allow in-situ sensor embedment through smart manufacturing for real-time monitoring, and performance of these systems. Here, this study focuses on experiments investigating the feasibility of in-situ sensor embedment using directed energy deposition (DED). Type K thermocouples are embedded into 316L stainless steel (SS) samples using two different configurations (e.g., exposed and embedded tips) and two designs (e.g., flush to substrate) within an AM base. Embedded sensor samples are analyzed via in-situ measurements and high-temperature performance validation tests at 350ºC and 900ºC. Temperature performance results at both temperature tests show good agreement with manufacturer specifications proving that these sensors could still capture accurate temperature readings after in-situ embedment during DED processing. An additional optimization experiment was conducted on the exposed tip configuration using a surrogate thermocouple to improve tolerances and the embedment process. Results improved tolerances, lower porosity, smaller gaps between the sensor and base, and better junction contact for the sensor. Although further optimization of this embedment strategy is necessary to improve the structural stability and tolerances within the component, this research strategy provides a proof-of-feasibility for DED embedment with commercial sheathed thermocouples. This research provides early impact on embedment of sensor for multiple materials and complex geometric components..

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Frequency and imaging features of abdominal immune-related adverse events in metastatic lung cancer patients treated with PD-1 inhibitor

Purpose: To investigate the frequency and imaging features of radiographically evident abdominal immune-related adverse events (irAEs) in patients with metastatic non-small-cell lung cancer (NSCLC) treated with PD-1 inhibitors. Methods: This retrospective study included 137 patients with metastatic NSCLC treated with PD-1 inhibitor nivolumab monotherapy (75 women; median age: 65 years), who had a baseline CT and at least one follow-up abdomen CT during therapy. Baseline and all follow-up abdominal CTs performed for monitoring of nivolumab therapy were reviewed to identify the organ-specific abdominal irAEs including colitis/enteritis, hepatitis, biliary toxicity, pancreatitis, nephritis, sarcoid-like reaction, and pancreatic and adrenal atrophy. Their frequency and imaging features were described. Results: Eighteen (13%) patients had radiologically identified abdominal irAEs (median 2.1 months after starting nivolumab; interquartile range 1.17–5.83 months); 16 patients developed enteritis/colitis (12 pancolitis, two segmental colitis, one enterocolitis, one enteritis), two hepatitis, one adrenalitis. One patient with hepatitis also developed colitis/enteritis. Radiographic abdominal irAE occurred after nivolumab therapy was discontinued in six patients before any subsequent therapy was started. IrAEs prompted nivolumab interruption and treatment with steroids in four patients (three colitis/enteritis, one hepatitis). Most common CT features of colitis/enteritis included mesenteric hyperemia (n = 15), bowel wall thickening (n = 13), mucosal hyperenhancement (n = 10), and fluid-filled colon (n = 9). Conclusion: Abdominal irAEs were detected on CT in 13% of NSCLC patients treated with nivolumab, and colitis, in the pancolitis form, was the most common irAE. Given the expanding role of immunotherapy, radiologists should be aware of the frequency and imaging manifestations of abdominal irAEs and the impact on patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of heat treatment and build orientation on the evolution of $ϵ$ and $α'$ martensite and strength during compressive loading of additively manufactured 304L stainless steel

In this paper, the effect of heat-treatment and build orientation on martensitic phase transformation in additively manufactured (AM) 304L stainless steel is studied and compared with conventionally produced wrought material. The relationships between observed martensitic transformations and material microstructures and their effects on mechanical strength are established through experimental observations. In situ high-energy X-ray powder diffraction measurements were performed to monitor the evolution of $ϵ$ and $α'$ martensite during compressive loading of stainless steel. Electron backscatter diffraction (EBSD) was used to provide insight on initial grain morphology, crystallographic misorientation within grains, and crystallographic texture. Heat treatment alters the microstructure of AM samples creating different initial conditions. This difference in starting microstructure resulted in variability in martensitic transformation during compressive deformation. The rate of martensitic transformation decreased for AM samples treated with temperatures up to 1100°C, after which the AM microstructures recrystallized, resulting in increased rate of martensitic transformation for those samples treated at higher temperatures. It was also observed that aligning the axis of compression with the AM build direction resulted in a lower rate of strain-induced martensite formation as opposed to aligning the compression axis perpendicular to it. More favorable distribution of crystal orientations in the latter loading orientation promoted martensitic transformation. These and additional experimental observations from EBSD in terms of kernel average misorientation, mean grain orientation spread, and mean crystallite size reveal strong microstructural effects on strength of additively manufactured metallic materials.

304L stainless steel↗

Pore structure development during hydration of tricalcium silicate by X-ray nano-imaging in three dimensions

We report that tricalcium silicate (C 3 S) is the most important component among the four main clinker phases of Portland cement. Pure C 3 S is widely used as a simplified model system of cement in various researches. However, the spatial structure development of cement, even pure C 3 S during hydration at the nano-scale has been rarely directly reported. In this work, X-ray nano-computed tomography (X-ray Nano-CT), a non-destructive X-ray analytical method, was used to study the hydration of a pure C 3 S sample with a water/C 3 S mass ratio of 0.5. The three-dimensional (3D) structure of the hydrating C 3 S specimen was investigated to see the internal pore structure evolution within the hardened C 3 S paste. Investigation of the 3D structural development of the C 3 S specimen at different hydration times was performed to monitor the changes of pore shapes and sizes/volumes. Lastly, it is found that volumes of the sealed pores generally grow larger, and the open pores become smaller while the volume and the external morphology of the whole hardened C 3 S paste remains almost the same during hydration.

36 MATERIALS SCIENCE↗

End-to-end online performance data capture and analysis for scientific workflows

With the increased prevalence of employing workflows for scientific computing and a push towards exascale computing, it has become paramount that we are able to analyze characteristics of scientific applications to better understand their impact on the underlying infrastructure and vice-versa. Such analysis can help drive the design, development, and optimization of these next generation systems and solutions. Here, we present the architecture, integrated with existing well-established and newly developed tools, to collect online performance statistics of workflow executions from various, heterogeneous sources and publish them in a distributed database (Elasticsearch). Using this architecture, we are able to correlate online workflow performance data, with data from the underlying infrastructure, and present them in a useful and intuitive way via an online dashboard. We have validated our approach by executing two classes of real-world workflows, both under normal and anomalous conditions. The first is an I/O-intensive genome analysis workflow; the second, a CPU- and memory-intensive material science workflow. Based on the data collected in Elasticsearch, we are able to demonstrate that we can correctly identify anomalies that we injected. The resulting end-to-end data collection of workflow performance data is an important resource of training data for automated machine learning analysis.

97 MATHEMATICS AND COMPUTING↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Projected network performance for next generation aerosol monitoring systems

Aerosol monitoring for radioactivity is a mature and proven technology. However, by improving key specifications of aerosol monitoring equipment, more samples per day can be collected and analyzed with the same minimum detectable concentrations as current systems. This work models hypothetical releases of 140 Ba and 131 I over a range of magnitudes corresponding to the inventory produced from the fission of about 100 g to 1 kiloton TNT-equivalent of 235 U. The releases occur over an entire year to incorporate the natural variability in atmospheric transport. Sampling equipment located at the 79 locations for radionuclide stations identified in the Comprehensive Nuclear-Test-Ban Treaty (CTBT) for the International Monitoring System are used to determine the detections of the individual releases. Alternative collection schemes in next generation equipment that collect 2, 3, or 4 samples per day, rather than the current 1 sample per day, would result in detections in many more samples at more stations with detections for a given release level. The authors posit that next generation equipment will result in increased network resilience to outages and improved source-location capability for lower yield source releases. The application of dual-detector and coincidence measurements to these systems would significantly boost sensitivity for some isotopes and would further enhance the monitoring capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗

The effect of low-temperature aging on the microstructure and deformation of uranium- 6 wt% niobium: An in-situ neutron diffraction study

The mechanical properties of uranium-niobium alloys evolve with aging at relatively low temperatures due to subtle microstructural changes. In-situ neutron diffraction measurements during aging of a monoclinic U-6Nb alloy at temperatures to 573 K were performed to monitor these changes. Further, in-situ neutron diffraction studies during deformation of U-6Nb in the as-quenched state and after aging for two and eight hours at 473 K were completed to assess the influence of microstructural evolution on mechanical properties. With heating, large anisotropic changes in lattice parameter were observed followed by relaxation with time at the aging temperature. The lattice parameters return to nearly their initial values with cooling. Finally, the active plastic deformation mechanisms including, in order of occurrence, shape-memory de-twinning, mechanical twinning, and slip-mediated deformation do not change with prior aging. However, the resistance to motion of the as-quenched martensitic twin boundaries increases following aging, resulting in the observed increase in initial yield strength.

36 MATERIALS SCIENCE↗

Design of a six-DOF motion tracking system based on a Stewart platform and ball-and-socket joints

This paper presents a six degree-of-freedom (DOF) real-time motion tracking system of measuring the position and the orientation for industrial robots in three-dimensional (3D) space. The proposed system is based on a typical Stewart platform design and utilizes six low-cost displacement sensors to monitor the motion of the Stewart platform. The advantage of the proposed system is its simple calibration and easy accessibility; the magnetic ball-and-socket joints used for rotational joints. With special measurement tools, the center of rotation of all twelve joints can be measured in 3D space at a glance. Following more than fifty measurements, the average root mean square (RMS) position accuracy error of the proposed device is less than 0.186 mm and the average of angular accuracy error is less than 0.160 °, making it suitable for monitoring the performance of industrial robot. As a result, a commercial robot is also tested by the proposed system to verify its usefulness.

42 ENGINEERING↗

Anomalies and Local Structure of Liquid Water from Boiling to the Supercooled Regime as Predicted by the Many-Body MB-pol Model

For the past 50 years, researchers have sought molecular models that can accurately reproduce water’s microscopic structure and thermophysical properties across broad ranges of its complex phase diagram. Herein, molecular dynamics simulations with the many-body MB-pol model are performed to monitor the thermodynamic response functions and local structure of liquid water from the boiling point down to deeply supercooled temperatures at ambient pressure. The isothermal compressibility and isobaric heat capacity show maxima near 223 K, in excellent agreement with recent experiments, and the liquid density exhibits a minimum at ~208 K. A local tetrahedral arrangement, where each water molecule accepts and donates two hydrogen bonds, is found to be the most probable hydrogen-bonding topology at all temperatures. Further, this work suggests that MB-pol may provide predictive capability for studies of liquid water’s physical properties across broad ranges of thermodynamic states, including the so-called water’s “no man’s land” which is difficult to probe experimentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Destructive Inspection Approach Using Ultrasound to Identify the Material State for Amorphous and Semi-Crystalline Materials

At present, there are many methods to identify the temperature and phase of a material using invasive techniques. However, most current methods require physical contact or implicit methods utilizing light reflectance of the specimen. In this paper, we present a nondestructive inspection method using ultrasonic wave technology that circumvents these disadvantages to identify phase change regions and infer the temperature state of a material. In the present study an experiment is performed to monitor the time of flight within a wax as it undergoes melting and the subsequent cooling. Results presented in this work show a clear relationship between a material’s speed of sound and its temperature. The phase change transition of the material is clear from the time of flight results, and in the case of the investigated material, this change in the material state occurs over a range of temperatures. The range of temperatures over which the wax material melts is readily identified by speed of sound represented as a function of material temperature. The melt temperature, obtained acoustically, is validated using Differential Scanning Calorimetry (DSC), which uses shifts in heat flow rates to identify phase transition temperature ranges. Lastly, the investigated ultrasonic NDE method has direct applications in many industries, including oil and gas, food and beverage, and polymer composites, in addition to many implications for future capabilities of nondestructive inspection of multi-phase materials.

36 MATERIALS SCIENCE↗