At least 667 records · Page 37

Point matching: A new electronic method for homogenizing the phase characteristics of giant magnetoimpedance sensors

Recently, our research group at PUC-Rio discovered that magnetic transducers based on the impedance phase characteristics of GMI sensors have the potential to multiply by one hundred the sensitivity values when compared to magnitude-based GMI transducers. Those GMI sensors can be employed in the measurement of ultra-weak magnetic fields, which intensities are even lower than the environmental magnetic noise. A traditional solution for cancelling the electromagnetic noise and interference makes use of gradiometric configurations, but the performance is strongly tied to the homogeneity of the sensing elements. This paper presents a new method that uses electronic circuits to modify the equivalent impedance of the GMI samples, aiming at homogenizing their phase characteristics and, consequently, improving the performance of gradiometric configurations based on GMI samples. It is also shown a performance comparison between this new method and another homogenization method previously developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supersymmetric symplectic quantum mechanics

Symplectic Quantum Mechanics SQM considers a non-commutative algebra of functions on a phase space Γ and an associated Hilbert space H{sub Γ} to construct a unitary representation for the Galilei group. From this unitary representation the Schrödinger equation is rewritten in phase space variables and the Wigner function can be derived without the use of the Liouville–von Neumann equation. In this article we extend the methods of supersymmetric quantum mechanics SUSYQM to SQM. With the purpose of applications in quantum systems, the factorization method of the quantum mechanical formalism is then set within supersymmetric SQM. A hierarchy of simpler hamiltonians is generated leading to new computation tools for solving the eigenvalue problem in SQM. We illustrate the results by computing the states and spectra of the problem of a charged particle in a homogeneous magnetic field as well as the corresponding Wigner function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase transitions in a few-electron quantum dot in a magnetic field: Wigner phases and broken-symmetry spin-singlet states

We develop a variational many-body approach within a second quantized formulation for a few-electron system in a parabolic two-dimensional quantum dot (QD). By way of application, the nature of the ground state of a two-electron system in a parabolic QD in a broad range of magnetic fields is theoretically investigated. Various phase transitions on the basis of the resulting analytical expressions for energy of the system have been investigated: First, the well-known transition from a maximum density droplet to a Wigner phase in a magnetic field is obtained, provided that the QD is in conditions of weak confinement. Furthermore, in the case of relatively strong QD confinement and weak magnetic fields, a rotationally symmetric spin-singlet state is the ground state of the system. However, in a strong magnetic field and for the same QD confinement, a broken-symmetry spin-singlet state appears to be energetically favored over the symmetric spin-singlet state. A first investigation of such a broken-symmetry spin-singlet phase in a QD in a magnetic field is shown to be an important application of the proposed technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acceleration of diffusive molecular dynamics simulations through mean field approximation and subcycling time integration

Highlights: • Two numerical methods are presented to accelerate DMD simulations. • The methods greatly reduce the computation time without much loss of accuracy. • The accelerated DMD model is capable of simulating long-term mass transport at atomistic length scales. • Demonstrated for the propagation of an atomically sharp phase boundary over 30 seconds. - Abstract: Diffusive Molecular Dynamics (DMD) is a class of recently developed computational models for the simulation of long-term diffusive mass transport at atomistic length scales. Compared to previous atomistic models, e.g., transition state theory based accelerated molecular dynamics, DMD allows the use of larger time-step sizes, but has a higher computational complexity at each time-step due to the need to solve a nonlinear optimization problem at every time-step. This paper presents two numerical methods to accelerate DMD based simulations. First, we show that when a many-body potential function, e.g., embedded atom method (EAM), is employed, the cost of DMD is dominated by the computation of the mean of the potential function and its derivatives, which are high-dimensional random variables. To reduce the cost, we explore both first- and second-order mean field approximations. Specifically, we show that the first-order approximation, which uses a point estimate to calculate the mean, can reduce the cost by two to three orders of magnitude, but may introduce relatively large error in the solution. We show that adding an approximate second-order correction term can significantly reduce the error without much increase in computational cost. Second, we show that DMD can be significantly accelerated through subcycling time integration, as the cost of integrating the empirical diffusion equation is much lower than that of the optimization solver. To assess the DMD model and the numerical approximation methods, we present two groups of numerical experiments that simulate the diffusion of hydrogen in palladium nanoparticles. In particular, we show that the computational framework is capable of capturing the propagation of an atomically sharp phase boundary over a time window of more than 30 seconds. The effects of the proposed numerical methods on solution accuracy and computation time are also assessed quantitatively.

36 MATERIALS SCIENCE↗

Exploring the grand-canonical phase diagram of interacting bosons in optical lattices by trap squeezing

In this article, we theoretically discuss how quantum simulators based on trapped cold bosons in optical lattices can explore the grand-canonical phase diagram of homogeneous lattice boson models, via control of the trapping potential independent of all other experimental parameters (trap squeezing). Based on quantum Monte Carlo, we establish the general scaling relation linking the global chemical potential to the Hamiltonian parameters for the Bose-Hubbard model in a parabolic trap, describing cold bosons in optical lattices; we find that this scaling relation is well captured by a modified Thomas-Fermi scaling behavior - corrected for quantum fluctuations - in the case of sufficiently high density and/or sufficiently weak interactions, and by a mean-field Gutzwiller ansatz over a much larger parameter range. This scaling relation allows us to control experimentally the chemical potential, independent of all other Hamiltonian parameters, via trap squeezing; given that the global chemical potential coincides with the local chemical potential in the trap center, measurements of the central density as a function of the chemical potential give access to the information on the bulk compressibility of the Bose-Hubbard model. Supplemented with time-of-flight measurements of the coherence properties, the measurement of compressibility enables one to discern among the various possible phases realized by bosons in an optical lattice with or without external (periodic or random) potentials - for example, superfluid, Mott insulator, band insulator, and Bose glass. We theoretically demonstrate the trap-squeezing investigation of these phases in the case of bosons in a one-dimensional optical lattice and in a one-dimensional incommensurate superlattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermodynamics and phase structure of the two-flavor Nambu-Jona-Lasinio model beyond large N{sub c}

The optimized perturbation theory (OPT) method is applied to the SU(2) version of the Nambu-Jona-Lasinio (NJL) model both at zero and at finite temperature and/or density. At the first nontrivial order, the OPT exhibits a class of 1/N{sub c} corrections which produce nonperturbative results that go beyond the standard large-N{sub c} or mean-field approximation. The consistency of the OPT method with the Goldstone theorem at this order is established, and appropriate OPT values of the basic NJL (vacuum) parameters are obtained by matching the pion mass and decay constant consistently. Deviations from standard large-N{sub c} relations induced by OPT at this order are derived, for example, for the Gell-Mann-Oakes-Renner relation. Next, the results for the critical quantities and the phase diagram of the model, as well as a number of other thermodynamical quantities of interest, are obtained with OPT and then contrasted with the corresponding results at large N{sub c}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Z 2 topological order and first-order quantum phase transitions in systems with combinatorial gauge symmetry

We study a generalization of the two-dimensional transverse-field Ising model, combining both ferromagnetic and antiferromagnetic two-body interactions, that hosts exact global and local Z 2 gauge symmetries. Using exact diagonalization and stochastic series expansion quantum Monte Carlo methods, we confirm the existence of the topological phase in line with previous theoretical predictions. Our simulation results show that the transition between the confined topological phase and the deconfined paramagnetic phase is of first order, in contrast to the conventional Z 2 lattice gauge model in which the transition maps onto that of the standard Ising model and is continuous. We further generalize the model by replacing the transverse field on the gauge spins with a ferromagnetic X X interaction while keeping the local gauge symmetry intact. We find that the Z 2 topological phase remains stable, while the paramagnetic phase is replaced by a ferromagnetic phase. The topological-ferromagnetic quantum phase transition is also of first order. For both models, we discuss the low-energy spinon and vison excitations of the topological phase and their avoided level crossings associated with the first-order quantum phase transitions.

2-dimensional systems↗

On the S-matrix of Ising field theory in two dimensions

We explore the analytic structure of the non-perturbative S-matrix in arguably the simplest family of massive non-integrable quantum field theories: the Ising field theory (IFT) in two dimensions, which may be viewed as the Ising CFT deformed by its two relevant operators, or equivalently, the scaling limit of the Ising model in a magnetic field. Our strategy is that of collider physics: we employ Hamiltonian truncation method (TFFSA) to extract the scattering phase of the lightest particles in the elastic regime, and combine it with S-matrix bootstrap methods based on unitarity and analyticity assumptions to determine the analytic continuation of the 2 → 2 S-matrix element to the complex s-plane. Focusing primarily on the “high temperature” regime in which the IFT interpolates between that of a weakly coupled massive fermion and the E 8 affine Toda theory, we will numerically determine 3-particle amplitudes, follow the evolution of poles and certain resonances of the S-matrix, and exclude the possibility of unknown wide resonances up to reasonably high energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computer synthesis of high resolution electron micrographs

Specimen damage, spherical aberration, low contrast and noisy sensors combine to prevent direct atomic viewing in a conventional electron microscope. The paper describes two methods for obtaining ultra-high resolution in biological specimens under the electron microscope. The first method assumes the physical limits of the electron objective lens and uses a series of dark field images of biological crystals to obtain direct information on the phases of the Fourier diffraction maxima; this information is used in an appropriate computer to synthesize a large aperture lens for a 1-A resolution. The second method assumes there is sufficient amplitude scatter from images recorded in focus which can be utilized with a sensitive densitometer and computer contrast stretching to yield fine structure image details. Cancer virus characterization is discussed as an illustrative example. Numerous photographs supplement the text.

Nathan, R.↗

Heavy hadrons in quark-gluon plasma

We use the nonperturbative quark-antiquark potential derived within the Field Correlator Method and the screened Coulomb potential to calculate binding energies and melting temperatures of heavy mesons and baryons in the deconfined phase of quark-gluon plasma.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of infrared two-color multicycle field synthesis for intense-isolated-attosecond-pulse generation

We present the optimization of the two-color synthesis method for generating an intense isolated attosecond pulse (IAP) in the multicycle regime. By mixing an infrared assistant pulse with a Ti:sapphire main pulse, we show that an IAP can be produced using a multicycle two-color pulse with a duration longer than 30 fs. We also discuss the influence of the carrier-envelope phase (CEP) and the relative intensity on the generation of IAPs. By optimizing the wavelength of the assistant field, IAP generation becomes insensitive to the CEP slip. Therefore, the optimized two-color method enables us to relax the requirements of pulse duration and easily produce the IAP with a conventional multicycle laser pulse. In addition, it enables us to markedly suppress the ionization of the harmonic medium. This is a major advantage for efficiently generating intense IAPs from a neutral medium by applying the appropriate phase-matching and energy-scaling techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Specific features of magnetic phase diagram of an MnSi helimagnet

Magnetization curves of MnSi single crystals have been measured in a range of temperatures T = 5.5-35 K and magnetic field strengths H {<=} 11 kOe for H Parallel-To [1 1 1], [0 0 1], and [1 1 0]. Special attention has been paid to the temperature interval near T{sub N} = 28.8 K, where MnSi exhibits a transition to the state with a long-period helical magnetic structure. Some new features in the magnetic behavior of MnSi have been found. In particular, in an intermediate temperature region above the transition (28.8 K = T{sub N} {<=} T < 31.5 K), the dM(H)/dH curves exhibit anomalies that are not characteristic of the typical paramagnetic state. It is established that the line of the characteristic field H*(T) of this anomaly is a natural extrapolation of the temperature dependence of the field of the transition from a conical phase to an induced ferromagnetic phase observed at T < T{sub N}. It is concluded that the properties of MnSi in the indicated intermediate region are related to and governed by those of the conical phase (rather than of the A phase). Based on these data, magnetic phase diagrams of MnSi for H Parallel-To [1 1 1], [0 0 1], and [1 1 0] are plotted and compared to diagrams obtained earlier by other methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Jet-Surface Interaction Test: Flow Measurements Results

Modern aircraft design often puts the engine exhaust in close proximity to the airframe surfaces. Aircraft noise prediction tools must continue to develop in order to meet the challenges these aircraft present. The Jet-Surface Interaction Tests have been conducted to provide a comprehensive quality set of experimental data suitable for development and validation of these exhaust noise prediction methods. Flow measurements have been acquired using streamwise and cross-stream particle image velocimetry (PIV) and fluctuating surface pressure data acquired using flush mounted pressure transducers near the surface trailing edge. These data combined with previously reported far-field and phased array noise measurements represent the first step toward the experimental data base. These flow data are particularly applicable to development of noise prediction methods which rely on computational fluid dynamics to uncover the flow physics. A representative sample of the large flow data set acquired is presented here to show how a surface near a jet affects the turbulent kinetic energy in the plume, the spatial relationship between the jet plume and surface needed to generate surface trailing-edge noise, and differences between heated and unheated jet flows with respect to surfaces.

Flow↗

Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac

Purpose: Linac-magnetic resonance (MR) systems have been proposed in order to achieve real-time image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to achieve better quality images while reducing hot and cold spots in treatment planning. An investigation of linac's performance in the longitudinal fringe magnetic fields of the MR imager is given. Methods: The open MR imager fringe magnetic field was modeled using the analytic solution of the magnetic field generated from current carrying loops. The derived solution was matched to the magnetic fringe field isolines provided for a 0.5 T open MR imager through Monte Carlo optimization. The optimized field solution was then added to the previously validated 6 MV linac simulation to quantify linac's performance in the fringe magnetic field of a 0.5 T MR imager. To further the investigation, linac's performance in large fringe fields expected from other imagers was investigated through the addition of homogeneous longitudinal fields. Results: The Monte Carlo optimization of the analytic current loop solution provided good agreement with the magnetic fringe field isolines supplied by the manufacturer. The range of magnetic fields the linac is expected to experience when coupled to the 0.5 T MR imager was determined to be from 0.0022 to 0.011 T (as calculated at the electron gun cathode). The effect of the longitudinal magnetic field on the electron beam was observed to be only in the electron gun. The longitudinal field changed the electron gun optics, affecting beam characteristics, such as a slight increase in the injection current and beam diameter, and an increasingly nonlaminar transverse phase space. Although the target phase space showed little change in its energy spectrum from the altered injection phase space, a reduction in the target current and spatial distribution peak intensity was observed. Despite these changes, the target phase space had little effect on the depth dose curves or dose profiles calculated for a 40x40 cm{sup 2} field at 1.5 cm depth. At longitudinal fields larger than 0.012 T, a drastic reduction in the injection current from the electron gun was observed due to a large fraction of electrons striking the anode. This further reduced the target current, which reached a minimum of 28{+-}2 mA at 0.06 T. A slow increase in the injection and target currents was observed at fields larger than 0.06 T due to greater beam collimation in the anode beam tube. Conclusions: In an effort to achieve higher quality images and a reduction in hot and cold spots in the treatment plan, a parallel configuration linac-MR system is presented. The longitudinal magnetic fields of the MR imager caused large beam losses within the electron gun. These losses may be eliminated through a redesign of the electron gun optics incorporating a longitudinal magnetic field, or through magnetic shielding, which has already been proven successful for the transverse configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Focus: Phase-resolved nonlinear terahertz spectroscopy—From charge dynamics in solids to molecular excitations in liquids

Intense terahertz (THz) electric field transients with amplitudes up to several megavolts/centimeter and novel multidimensional techniques are the key ingredients of nonlinear THz spectroscopy, a new area of basic research. Both nonlinear light-matter interactions including the non-perturbative regime and THz driven charge transport give new insight into the character and dynamics of low-energy excitations of condensed matter and into quantum kinetic phenomena. This article provides an overview of recent progress in this field, combining an account of technological developments with selected prototype results for liquids and solids. The potential of nonlinear THz methods for future studies of low-frequency excitations of condensed-phase molecular systems is discussed as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-358: Monte Carlo Dose Calculation of Small Field Electron Beams

Purpose: Dynamic radiotherapy involving electron beams such as Dynamic Electron Arc Radiotherapy (DEAR) requires accurate dose modelling of small field sizes, similar to the requirement of IMRT field on the small photon field. The current commercial electron Monte Carlo algorithms such as eMC v11 in Eclipse were developed for standard field sizes and do not support the planning of dynamic therapy yet. The purpose of this study is to develop a method to accurately model small field electron beam dosimetry using Monte Carlo simulations. Methods: Comparison between eMC, phantom measurements (diode), and Monte Carlo (MC) simulations (BEAMnrc/DOSYZnrc) were performed for a Varian TrueBeam linac. MC simulations utilized Varian TrueBeam phase space files which had been validated in another study. Static single small field was assessed by comparing dose distributions in water for a 16 MeV beam for circular (2 cm diameter) and rectangular (1×10 cm{sup 2}) cut-out. MC was performed with a resolution of 2.5×2.5×2 mm{sup 2} and statistical uncertainty < 4%. The dose distribution was averaged over adjacent bins to improve precision. Depth dose and orthogonal profiles were evaluated. Results: Small field PDDs differ from those with standard cones. For both circular and rectangular cutouts, the difference in range R8 0-R1 0 is less than 2 mm and in dose within 2%. For the orthogonal profiles, field size and penumbra differences were within 1 mm at depth of maximum dose. The eMC displayed a distinctive “step” in the out-field dose profile in disagreement with both measurement and MC results and needs further investigation. Conclusion: MC was able to characterize the small field dosimetry with good agreement with the measurement data, and thus offers the opportunity for treatment planning of dynamic radiotherapy. Analyses for all other electron energies and cut-out sizes are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

Quantum correlations and dynamics from classical random fields valued in complex Hilbert spaces

One of the crucial differences between mathematical models of classical and quantum mechanics (QM) is the use of the tensor product of the state spaces of subsystems as the state space of the corresponding composite system. (To describe an ensemble of classical composite systems, one uses random variables taking values in the Cartesian product of the state spaces of subsystems.) We show that, nevertheless, it is possible to establish a natural correspondence between the classical and the quantum probabilistic descriptions of composite systems. Quantum averages for composite systems (including entangled) can be represented as averages with respect to classical random fields. It is essentially what Albert Einstein dreamed of. QM is represented as classical statistical mechanics with infinite-dimensional phase space. While the mathematical construction is completely rigorous, its physical interpretation is a complicated problem. We present the basic physical interpretation of prequantum classical statistical field theory in Sec. II. However, this is only the first step toward real physical theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗