Search NASA⌕ Search

SEARCH · Search NASA

Results for “power grid simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Coupled numerical simulation of the external and engine inlet flows for the F-18 at large incidence

This paper presents a numerical simulation of the external and engine inlet flows for the F-18 aircraft at typical high-angle-of-attack flight conditions. Two engine inlet mass flow rates, corresponding to flight idle and maximum power, were computed. This was accomplished using a structured, overset grid technique to couple the external and internal grid systems. Reynolds-averaged Navier-Stokes solutions were obtained using an implicit, finite-differencing scheme. Results show a strong coupling of the external and engine inlet flows, especially at the maximum power setting. Increasing the mass flow rate through the inlet caused the primary vortex breakdown location to move downstream. This trend is also observed in flight tests performed on the F-18. A reversed flow region upstream of the inlet duct is visible in the faired-inlet and flight-idle computations. This flow reversal is not present in the maximum power setting computation. These large-scale changes in flow structure highlight the importance of simulating inlet conditions in high-angle-of-attack aircraft computations.

Murman, Scott M.↗

Multi-decade high-resolution regional hindcasts for wave energy resource characterization in U.S. coastal waters

Long-term, high-resolution, regional wave hindcast datasets were generated using unstructured-grid Simulating WAves Nearshore (SWAN) models for the U.S. coastal waters to support nearshore wave energy development in the U.S. including those bordering U.S. territorial islands. The model domains resolved the entire U.S. exclusive economic zones, with a spatial resolution of approximately 200 m nearshore. The regional SWAN models were driven by the global WAVEWATCH III® model outputs and run for a 42-year period from 1979 to 2020. Extensive model validations were performed using buoy observations and altimeter data. Regional resource characterization was performed based on hindcast data points at 2 km from shore and along the 100 m isobath. Aggregations of wave resource parameters were produced, and spatial and seasonal variations were analyzed for all the regions. Wave resource metrics recommended by international standards, including a 3-hour time series of six resource parameters, hourly frequency- and directionally resolved wave spectra at selected “virtual buoy” locations, and average-annual values of omni-directional wave power, significant wave height, and energy period are publicly disseminated through an Amazon Web Service and a Marine Energy Atlas web application tool to facilitate wave energy research and a wide range of coastal ocean applications.

16 TIDAL AND WAVE POWER↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A systematic solution to quantify economic values of vehicle grid integration

We report Vehicle-Grid-Integration (VGI) supplies one of the potential benefit extensions for electric vehicles (EVs) to make use of their parking time, which enables the EVs to provide grid services while still meeting consumer driving needs. However, the costs, benefits and risks of VGI still remain unclear, which limits the development of the VGI to promote the interaction between the EV and grid. In this study, we propose an integrated framework to quantify and utilize the aggregate flexibility of the EVs to supply the grid services in electricity markets. The integrated solution includes five sub-modules that cover end-to-end functionalities from individual EV energy consumption estimation to final monetary values calculation of providing grid services. Both wholesale market and local level charging management are formulated in the optimization module. A predictive control algorithm is proposed to allocate power to individual vehicles in real time, considering uncertainties from dispatch signal and travel behavior. Simulation results from 10,000 EVs indicate that the proposed optimization methods can significantly reduce the system cost in both wholesale market and retail market. Local tariff optimization reduces the electricity cost by 24.4% compared to uncontrolled charging. Wholesale market optimization results show that $\$$691 and $\$$255 revenues can be captured by each EV in ERCOT and CAISO markets per year, although with a conservative assumption on battery throughput cost at 0.16$\$$/kWh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

pnnl/oedisi_dopf

OpenEDI - System Integration (OEDI-SI) - PNNL Distributed Optimal Power Flow (DOPF)

Slay, Tylor↗

eGridGPT: Trustworthy AI in the Control Room

This report outlines the synergy between human decision making and generative artificial intelligence (GenAI), where GenAI supports power system operators by analyzing procedures, suggesting actions, simulating scenarios with physics-based digital twins, and recommending optimal decisions. This report is the first research effort to apply large language models (LLMs), a type of GenAI, in the power grid control room. The authors describe the Electric Grid Generative Pretrained Transformer (eGridGPT), an LLM that virtually assists system operators. Developed with cybersecurity and regulatory requirements in mind, eGridGPT represents an opportunity to responsibly evolve control room technologies to meet the needs of a rapidly changing grid. As an innovative concept, eGridGPT seeks to spearhead productive discussions about the advanced technologies in the control room of the future amid the transition to clean energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamics of Numerics & Spurious Behaviors in CFD Computations

The global nonlinear behavior of finite discretizations for constant time steps and fixed or adaptive grid spacings is studied using tools from dynamical systems theory. Detailed analysis of commonly used temporal and spatial discretizations for simple model problems is presented. The role of dynamics in the understanding of long time behavior of numerical integration and the nonlinear stability, convergence, and reliability of using time-marching approaches for obtaining steady-state numerical solutions in computational fluid dynamics (CFD) is explored. The study is complemented with examples of spurious behavior observed in steady and unsteady CFD computations. The CFD examples were chosen to illustrate non-apparent spurious behavior that was difficult to detect without extensive grid and temporal refinement studies and some knowledge from dynamical systems theory. Studies revealed the various possible dangers of misinterpreting numerical simulation of realistic complex flows that are constrained by available computing power. In large scale computations where the physics of the problem under study is not well understood and numerical simulations are the only viable means of solution, extreme care must be taken in both computation and interpretation of the numerical data. The goal of this paper is to explore the important role that dynamical systems theory can play in the understanding of the global nonlinear behavior of numerical algorithms and to aid the identification of the sources of numerical uncertainties in CFD.

Yee, Helen C.↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of Etching in Chlorine Discharges Using an Integrated Feature Evolution-Plasma Model

To better utilize its vast collection of heterogeneous resources that are geographically distributed across the United States, NASA is constructing a computational grid called the Information Power Grid (IPG). This paper describes various tools and techniques that we are developing to measure and improve the performance of a broad class of NASA applications when run on the IPG. In particular, we are investigating the areas of grid benchmarking, grid monitoring, user-level application scheduling, and decentralized system-level scheduling.

Hwang, Helen H.↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation: Preprint

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyber attacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyber attack scenarios on matrix completion. Realistic cyber attack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Utility Asset Vulnerability Assessment (GUAVA) Software Tool

Increasing demand and changes in generation portfolios is pushing power grid to operate towards the limit. However, due to lack of analytical tools for understanding various scales of impact on grid, it is becoming more vulnerable to wide scale power outages and blackouts. A vulnerable grid operating at its limit can be easily disrupted by asset failures caused by devastating hurricanes which has been known to damage transmission and distribution lines along its track. In this direction, researchers have focused on determining these assets by conducting Monte Carlo simulations of hurricanes with uncertainties and collected a large set of simulation data. To determine the infrastructure updates necessary for mitigating wide scale impact of hurricanes on the grid, we propose a software tool named “Grid Utility Asset Vulnerability Analysis” (GUAVA) framework. GUAVA presents a novel data-driven probabilistic analytical approach to (1) post-process hurricane failure scenarios, (2) identify/rank assets that are most vulnerable and critical to failing and are associated with highest impact/risk, and (3) to inform system upgrade decisions & prioritization. Based on the observed results and employed data-driven methodology, it is expected GUAVA can be adapted to provide power system planners with a recommendation engine for making informed decisions to improve resilience of grid.

Mahapatra, Kaveri↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

Numerical simulation of a relativistic magnetron using a fluid electron model

An approach to numerically modeling relativistic magnetrons, in which the electrons are represented with a relativistic fluid, is described. A principal effect in the operation of a magnetron is space-charge-limited (SCL) emission of electrons from the cathode. We have developed an approximate SCL emission boundary condition for the fluid electron model. This boundary condition prescribes the flux of electrons as a function of the normal component of the electric field on the boundary. Here we show the results of a benchmarking activity that applies the fluid SCL boundary condition to the one-dimensional Child–Langmuir diode problem and a canonical two-dimensional diode problem. Simulation results for a two-dimensional A6 magnetron are then presented. Computed bunching of the electron cloud occurs and coincides with significant microwave power generation. Numerical convergence of the solution is considered. Sharp gradients in the solution quantities at the diocotron resonance, spanning an interval of three to four grid cells in the most well-resolved case, are present and likely affect convergence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗